At least 199 records · Page 11Linked to original sources

Sustained transgene expression in intervertebral disc cells in vivo mediated by microbubble-enhanced ultrasound gene therapy.

STUDY DESIGN: In vivo studies using a rat model were performed to determine the feasibility of microbubble-enhanced ultrasound gene transfer technique to the intervertebral disc. OBJECTIVES: 1) To establish this microbubble-enhanced ultrasound gene therapy technique for intervertebral disc cells in vivo without using viral vectors and 2) to estimate the duration of transgene expression in vivo. SUMMARY OF BACKGROUND DATA: Intervertebral disc degeneration and associated spinal disorders remain a formidable problem. Although gene therapy approaches have been reported as having promising therapeutic potential to regenerate the disc, concerns over safety issues using recombinant viral vectors limits its application. Successful gene transfer using ultrasound has been reported in muscle and cardiovascular systems in vivo. MATERIALS AND METHODS: Two different reporter plasmid DNA encoding green fluorescent protein (GFP) and firefly luciferase were used. Plasmid DNA was mixed with ultrasonography contrast agent (microbubbles) and injected into coccygeal intervertebral discs of Sprague-Dawley rats. The therapeutic ultrasound was irradiated on the surface of injected discs. Rats were killed 1, 3, 6, 12, and 24 weeks after gene transduction. Harvested nucleus pulposus tissues were used for evaluation of transgene expression. The intact discs were used as a control. RESULTS: Seven days after gene transfection, considerable numbers of GFP-positive cells were observed in nucleus pulposus from the GFP-transfected group. Luciferase assay revealed that the ultrasound group demonstrated approximately an 11-fold increase in luciferase activity over the plasmid DNA-only group. Furthermore, transgene expression mediated by this method was observed, at least up to 24 weeks. CONCLUSIONS: Our study indicated that ultrasound transfection method with microbubbles significantly enhanced transfection efficiency of plasmid DNA into the nucleus pulposus cells in vivo. Furthermore, the sustained transgene expression in vivo was possible up to 24 weeks. The long-term gene expression mediated by simple and safe procedure has important clinical applications, including the treatment of chronic types of disease such as degenerative disc diseases.

Animals↗

Increase in capillary perfusion following low-intensity ultrasound and microbubbles during postischemic reperfusion.

OBJECTIVES: We postulated that the increase in shear stress caused by microbubbles in the presence of low-intensity ultrasound increases vasodilation in ischemia/reperfusion. DESIGN: Prospective, randomized, and blinded experimental study. SETTING: Research laboratory. SUBJECTS: Forty hamsters were subjected to ischemia/reperfusion and observed by intravital microscopy. INTERVENTIONS: Ultrasound (2.5 MHz, 1.3 mechanical index, 2.0 peak pressure) was applied to the hamster cheek pouch in ischemia/reperfusion with and without microbubbles (Levovist or Sono Vue) at baseline (15 mins) and at the beginning (15 mins) of reperfusion after ischemia (30 mins). MEASUREMENTS AND MAIN RESULTS: Arterial diameter (A2-A3, 38.5 +/- 5.3 microm; A4,15.0 +/- 7.0 microm), red blood cell velocity, wall shear stress, permeability, perfused capillary length, and adherent leukocytes in venules were evaluated. Lipid peroxides were also determined in the systemic blood. Ultrasound and microbubbles in reperfusion significantly increased the diameter (A2-A3 Sono Vue, 33%; Levovist, 53% vs. ischemia/reperfusion, p < .05; A4, Sono Vue, 93%; Levovist, 104% vs. ischemia/reperfusion, p < .05), red blood cell velocity, flow, and shear stress in both A4 and A2-A3 arterioles. Shear stress was significantly higher with Levovist (A2-A3, 105%; A4, 185%) and Sono Vue (A2, 108%; A4, 140% vs. ischemia/reperfusion, p < .05) than ultrasound alone in arterioles. With ischemia/reperfusion, perfused capillary length was reduced significantly, whereas it increased with Levovist and Sono Vue (43%, 41% vs. ischemia/reperfusion p < .05). Lipid peroxides increased early during reperfusion and remained at increased levels throughout reperfusion. Lipid peroxides were unchanged after ultrasound alone or ultrasound with Sono Vue or Levovist during ischemia/reperfusion. With ultrasound there was a significant increase in vascular permeability vs. ischemia/reperfusion. Treatment with Sono Vue (-36%) and Levovist (-57%) decreased permeability vs. ischemia/reperfusion in reperfusion (p < .001). Ischemia/reperfusion had significantly increased leukocyte adhesion. Ultrasound alone (-39%) or with Sono Vue (-64%) and Levovist (-57%) caused smaller increases in leukocyte adhesion than ischemia/reperfusion (p < .05). CONCLUSIONS: Ultrasound and microbubbles equilibrate microvascular shear stress, thus avoiding the failure of capillary perfusion in postischemic reperfusion.

Animals↗

A novel technique to measure splanchnic transit time using microbubble ultrasound.

OBJECTIVE: The objective of this study was to measure splanchnic transit time by intravenous injection of a microbubble. MATERIALS AND METHODS: Ten volunteers were examined before and after eating. After Doppler indices of splanchnic circulation were obtained, the superior mesenteric artery (SMA) and vein (SMV) were simultaneously interrogated using power Doppler ultrasound after intravenous injection of a microbubble. Contrast arrival in the SMA and subsequently the SMV was recorded and splanchnic transit time calculated from differences in the time-intensity curves. RESULTS: Splanchnic transit time decreased significantly after eating (mean 11 vs. 6.9 seconds; P = 0.007), reflecting splanchnic hemodynamics. Between-subject variability attributable to repeated measurements was least for the SMA resistive index (17%) but 56% for the new index, suggesting poor reproducibility. CONCLUSION: Splanchnic transit time may be measured by microbubble injection but is subject to considerable measurement error. Newer microbubbles and imaging methods may allow more reproducible measurements.

Adult↗

High frequency nonlinear B-scan imaging of microbubble contrast agents.

It previously was shown that it is possible to produce nonlinear scattering from microbubble contrast agents using transmit frequencies in the 14-32 MHz range, suggesting the possibility of performing high-frequency, nonlinear microbubble imaging. In this study, we describe the development of nonlinear microbubble B-scan imaging instrumentation capable of operating at transmit center frequencies between 10 and 50 MHz. The system underwent validation experiments using transmit frequencies of 20 and 30 MHz. Agent characterization experiments demonstrate the presence of nonlinear scattering for the conditions used in this study. Using wall-less vessel phantoms, nonlinear B-scan imaging is performed using energy in one of the subharmonic, ultraharmonic, and second harmonic frequency regions for transmit frequencies of 20 and 30 MHz. Both subharmonic and ultraharmonic imaging modes achieved suppression of tissue signals to below the noise floor while achieving contrast to noise ratios of up to 26 and 17 dB, respectively. The performance of second harmonic imaging was compromised by nonlinear propagation and offered no significant contrast improvement over fundamental mode imaging. In vivo experiments using the subharmonic of a 20 MHz transmit pulse show the successful detection of microvessels in the rabbit ear and in the mouse heart. The results of this study demonstrate the feasibility of nonlinear microbubble imaging at high frequencies.

Animals↗

Microbubble-induced detachment of coadhering oral bacteria from salivary pellicles.

The presence and maturity of the salivary pellicle influences microbial adhesion and its tenacity in the oral cavity, posing a challenge to different plaque-control systems. Some plaque-control systems rely on surface-tension forces arising from passing microbubbles sprayed over the pellicle. Passage of such bubbles is accompanied by a high fluid flow, but systematic studies are lacking on the contribution of fluid flow vs. microbubbles towards plaque removal. Therefore, the aim of this study was to determine the detachment efficacy of laminar fluid flow (wall shear rates 11,000-16,000 s(-1)), with and without microbubbles, towards the detachment of Actinomyces naeslundii T14V-J1 and Streptococcus oralis J22, and their coadhering aggregates, from salivary pellicles formed over 2 h or 16 h from reconstituted human whole saliva. Microbubbles in a fluid flow were more efficient at inducing single bacterial detachment, resulting in almost complete (97%) removal for S. oralis J22 and a 15-fold increase in A. naeslundii T14V-J1 removal as compared to the detachment caused by fluid flow alone. A. naeslundii was more difficult to remove and apparently formed the strongest bonds with high-molecular-weight proteins in 16-h pellicles. The detachment of coaggregates after 2 min left a substantial amount of adhered bacterial mass, including more than 60% of singly attached A. naeslundii on the pellicle surface, providing nucleation sites for the de novo adhesion of coadhering streptococci.

Actinomyces↗

Effect of coupled oscillations on microbubble behavior.

Ultrasound contrast agents are encapsulated microbubbles whose nonlinear acoustic scattering signatures have been the foundation of their use in diagnostic imaging. The coupled oscillations of microbubbles along their lines of center are investigated theoretically using radial equations in the monopole approximation and an energy balance, which is obtained for the system. Coupled microbubble pairs of different initial radii are investigated numerically relative to the normal modes for the linearized system. For microbubble pairs of different size bubbles driven below the mode of the smaller bubble and above the mode of the larger bubble, it is shown that oscillations of the smaller agent are affected substantially more by the coupling than those of the larger one. For separation distances of 10 and 500 microns, a difference of approximately 10 dB occurs in the second harmonic output of a 1.0-micron radius agent coupled with a 2.2-micron radius agent forced at 2.0 MHz and 0.3 MPa. The subharmonic spectral peak is shown to decrease approximately 19 dB for the coupling of 1.5- and 2.2-micron radius agents at 10- and 500-micron distances under the same acoustic forcing conditions. These coupling effects on the radiated pressure and its spectral power are highlighted for contrast agent imaging applications.

Humans↗

The powerful microbubble: from bench to bedside, from intravascular indicator to therapeutic delivery system, and beyond.

This review discusses the development, current applications, and therapeutic potential of ultrasound contrast agents. Microbubbles containing gases act as true, intravascular indicators, permitting a noninvasive, quantitative analysis of the spatial and temporal heterogeneity of blood flow and volumes within the microvasculature. These shelled microbubbles are near-perfect reflectors of acoustic ultrasound energy and, when injected intravenously into the bloodstream, reflect ultrasound waves within the capillaries without disrupting the local environment. Accordingly, microbubble ultrasound contrast agents are clinically useful in enhancing ultrasound images and improving the accuracy of diagnoses. More recently, ultrasound contrast agents have been used to directly visualize the vasa vasorum and neovascularization of atherosclerotic carotid artery plaques, thus suggesting a new paradigm for diagnosis and treatment of atherosclerosis. Future applications of these microscopic agents include the deliver of site-specific therapy to targeted organs in the body. Medical therapies may use these microbubbles as carriers for newer therapeutic options.

Animals↗

Stable microbubble test on tracheal aspirate for the diagnosis of respiratory distress syndrome.

BACKGROUND: Exogenous surfactant should be used as early as possible in the presence of respiratory distress syndrome (RDS), but diagnosis may only become clear late in the course of the disease. The stable microbubble test (SMT) in the tracheal aspirates could help in the decision to give early surfactant to preterm babies with respiratory distress. OBJECTIVES: The objective of this study was to evaluate the accuracy of the SMT on tracheal aspirate for the diagnosis of RDS in newborns requiring mechanical ventilation. METHODS: The test was performed on specimens obtained from 74 infants requiring mechanical ventilation, through routine suctioning. RESULTS: Patients with RDS and meconium aspiration syndrome (MAS) had a significantly lower stable microbubble count than non-RDS and non-MAS patients. Preterm infants without RDS had a significantly higher microbubble count than preterm babies with RDS and a similar count to that of term babies. Considering a cutoff point of 120 microbubbles/mm(2) for the diagnosis of RDS, the sensitivity of the microbubble test was 96.3% (95% CI: 79.1-99.8) and the specificity 97.6% (95% CI: 85.9-99.9). CONCLUSIONS: The SMT on tracheal aspirates is accurate for RDS diagnosis and may be useful to support the decision to give surfactant to newborns on mechanical ventilation.

Gestational Age↗

Ultrasound-microbubble-mediated NF-kappaB decoy transfection attenuates neointimal formation after arterial injury in mice.

OBJECTIVE: Decoy transfection is a significant methodology for suppressing gene activation. The decoy can be synthesized easily; however, the major obstacle is the difficulty involved in effective in vivo delivery. METHODS AND RESULTS: We used a fluorescein-labeled decoy to investigate the ultrasound-microbubble-mediated in vivo delivery in normal and injured mouse arteries. We showed that this approach could deliver the decoy into target tissues. In addition, we performed in vivo NF-kappaB decoy transfection into murine injured arteries using the ultrasound-microbubble method. Murine femoral arteries were injured using flexible wires to establish arterial injury. Pathologically, neointima/media areas in the NF-kappaB decoy transfection using ultrasound-microbubble group showed less than those in the control groups. Immunohistochemistry revealed that enhanced expression of inflammatory factors was observed in nontreated injured arteries, while the NF-kappaB decoy suppressed the expression. CONCLUSION: We revealed that ultrasound-microbubble delivery of the decoy is effective for transfection into target organs. We also indicated that NF-kappaB decoy transfection using this method has potential for the suppression of neointimal formation. Ultrasound-mediated transfection of the decoy can be beneficial for the clinical treatment of restenosis after coronary intervention and other cardiovascular diseases.

Animals↗

Targeted delivery of bone marrow mononuclear cells by ultrasound destruction of microbubbles induces both angiogenesis and arteriogenesis response.

OBJECTIVE: Ultrasound (US)-mediated destruction of contrast microbubbles causes capillary rupturing that stimulates arteriogenesis, whereas intramuscular implantation (im) of bone marrow mononuclear cells (BM-MNCs) induces angiogenesis. We therefore studied whether US-targeted microbubble destruction combined with transplantation of BM-MNCs can enhance blood flow restoration by stimulating both angiogenesis and arteriogenesis. METHODS AND RESULTS: US-mediated destruction of phospholipid-coated microbubbles was applied onto ischemic hindlimb muscle and subsequently BM-MNCs were transfused. A significant enhancement in blood flow recovery after Bubble+US+BM-MNC infusion (34% increase, P<0.05) was observed compared with Bubble+US (25%). The ratio of capillary/muscle fiber increased by Bubble+US+BM-MNC-i.v (260%, P<0.01) than that in the Bubble+US group (172%), into which BM-MNCs were incorporated (angiogenesis). Smooth muscle alpha-actin-positive arterioles were also increased, and angiography showed augmented collateral vessel formation (arteriogenesis). Platelet-derived proinflammatory factors activated by Bubble+US induces the expression of adhesion molecules (P-selectin and ICAM-1), leading to the attachment of transplanted BM-MNCs on the endothelium. Flow assay confirmed that the platelet-derived factors cause the adhesion of BM-MNCs onto endothelium under laminar flow. CONCLUSIONS: This study demonstrates that the targeted delivery of BM-MNCs by US destruction of microbubbles enhances regional angiogenesis and arteriogenesis response, in which the release of platelet-derived proinflammatory factors activated by Bubble+US play a key role in the attachment of transplanted BM-MNCs onto the endothelial layer.

Angiography↗

Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery.

Neurological complications remain an important cause of morbidity and mortality of patients following cardiopulmonary bypass (CPB). Microemboli, as well as cerebral hypoperfusion, are the main postulated mechanisms. This study demonstrates that the insertion of a dynamic bubble trap (DBT) into the curcuit reduces microbubbles in the arterial line and microembolic signals (MES) in the middle cerebral arteries (MCAs). We investigated 12 patients during coronary artery bypass grafting (CABG). The DBT was inserted between the arterial filter and the arterial cannula. For detection of microemboli before and after the DBT, a special ultrasound Doppler device was used. MES were detected by transcranial Doppler monitoring in both MCAs of the patients. Microbubbles and MES were counted during bypass. These data were compared to 12 patients who were operated in a previous period without the use of a DBT. There were no significant differences in both groups with respect to gender, age, crossclamp and bypass time and number of anastomoses. In the group without a DBT in the circuit, a mean of 6311 microbubbles per operation could be observed distal to the arterial filter, corresponding to 282 MES. After inclusion of a DBT, we could register, in the second group, 8496 microemboli proximal and 2915 distal of the DBT, corresponding to 89 MES per operation. The reduction rate of microbubbles in the tubing was 65.7%, corresponding to a reduction in MES of about 86.2%. We conclude that the insertion of a DBT in the arterial line of CPB circuit protects the cerebrovascular system from microembolic events, as demonstrated by lower MES counts.

Aged↗

Characterization of tumor imaging with microbubble-based ultrasound contrast agent, sonazoid, in rabbit liver.

In order to investigate improvement of hepatic tumor detectability by Sonazoid with phase inversion imaging, the contrast effects on the liver of metastatic carcinoma-model rabbits were evaluated by videodensitometry and visual assessment. Correlation between the contrast enhancement of Sonazoid and histopathology was examined using the same animals. Electron microscopy was performed on hepatic tissue from another healthy rabbits to identify the distribution of Sonazoid microbubbles. As a result, all tumors were smaller than 12 mm in diameter, and after intravenous injection of Sonazoid, they were surrounded with a ring of enhanced signal during the early phase (up to 30 s), followed by a clear contrast defect during the delayed phase (after 10 min). Histopathologic observation revealed that the ring-enhancement was caused by neovasculature in the tumor, and the contrast defects corresponded to living and dead parts of tumors, which lack Kupffer cells. Videodensitometric differences between tumor and healthy tissue markedly increased at delayed phase, and visual detectability of tumors was improved when Sonazoid was used. Ultrastructural analysis showed microbubble-like structures in Kupffer cells, which indicated that Sonazoid microbubbles were taken up with these cells. In conclusion, Sonazoid, used with phase inversion imaging, greatly increases the detectability of small hepatic tumors by highlighting neovascularity at early phase and providing clear contrast defects due to absence of Kupffer cells, which take up Sonazoid microbubbles, at delayed phase.

Animals↗

Comparison of visual and quantitative analysis for characterization of insonated liver tumors after microbubble contrast injection.

OBJECTIVE: The objective of our study was to compare diagnostic performance of visual and quantitative analysis for the characterization of liver tumors insonated at low transmit power after microbubble contrast agent injection. SUBJECTS AND METHODS: This series comprised 166 liver tumors (1-5 cm in diameter) in 166 patients (99 men, 67 women; mean age +/- SD, 58 +/- 11 years) scanned at low transmit power (mechanical index: 0.1-0.14) after sulfur hexafluoride-filled microbubble injection. Digital cine clips recorded at the arterial phase (10-40 sec after contrast injection) and late phase (100-300 sec) were analyzed to characterize liver tumors as benign or malignant. Visual analysis was performed by three independent blinded reviewers who evaluated enhancement patterns at the arterial phase and subjective tumor conspicuity at the late phase. Quantitative analysis of videotape intensity (VI: gray-scale levels, 0-255) was performed to calculate objective tumor conspicuity at the late phase: (VI(tumor) - VI(liver)) / VI(liver). RESULTS: Characteristic enhancement patterns were observed in malignant tumors (peripheral rimlike) and benign tumors (peripheral nodular or central and spoke-wheel-shaped). Malignant (n = 95) versus benign (n = 71) tumors differed for subjective (median value: -1 vs 1, respectively) and objective conspicuity at the late phase (-0.6 vs 0.15, respectively; p = 0.001, Mann-Whitney U test) due to persistent microbubble uptake in benign tumors. Diagnostic performance of visual (odds ratio: reviewer 1 = 4.28, reviewer 2 = 10.18, reviewer 3 = 9.56) and quantitative (odds ratio: 89.33) analyses differed significantly in the characterization of liver tumors (p = 0.01, chi-square test). CONCLUSION: Quantitative analysis revealed higher diagnostic performance than visual analysis to characterize liver tumors insonated at low transmit power after microbubble contrast agent injection.

Adult↗

On the usefulness of the mechanical index displayed on clinical ultrasound scanners for predicting contrast microbubble destruction.

OBJECTIVE: The purpose of this study was to evaluate the mechanical index (MI) displayed on clinical ultrasound scanners as a predictor of exposure conditions related to the destruction of sonographic microbubble contrast agents. METHODS: Sonazoid (GE Healthcare, Oslo, Norway) and Optison (GE Healthcare, Princeton, NJ) microbubbles were injected into a tissue-mimicking flow phantom. Gray scale imaging was performed with 4 different scanners and 3 different transducers (3.5 MHz curved linear, 2.5 MHz convex, and 7.5 MHz linear array), and the MI displayed by the scanner was varied from 0.2 to 1.5 by changing the system output power. All other scanning parameters were kept constant. Downstream changes in echogenicity were monitored with a PowerVision 7000 scanner (Toshiba America Medical Systems, Tustin, CA) as an indirect measure of bubble destruction. Video intensity changes within the flow tube were determined as a function of MI for the different scanner/transducer combinations, and the best linear fit was determined. RESULTS: At a displayed MI of 0.7, different scanner/transducer combinations exhibited a range in video intensity from +16% to -3% of baseline for Sonazoid and from +8% to -71% for Optison. At an MI of 0.3, reductions in video intensity of up to 32% were produced. These results indicate a wide range in bubble destruction at identical MI values. Likewise, regression analysis found no linear fits for all scanner/transducer combinations (r2 < 0.046). CONCLUSIONS: The MI displayed on clinical ultrasound scanners does not predict the degree of microbubble destruction and should not be used by itself to define exposure conditions for destruction of microbubble contrast agents.

Acoustics↗

Microbubbles as novel pressure-sensitive MR contrast agents.

Magnetic resonance imaging contrast agents that are sensitive to pressure would be useful for evaluating cardiovascular function. One such potential contrast agent consists of gas-filled liposome microbubbles. The magnetic susceptibility of the microbubbles locally perturb the static magnetic field, which influences the transverse-relaxation properties of the surrounding medium. Changes in the pressure alter the bubble dimensions, which affects the magnetic field perturbations and, hence, the transverse-relaxation. The effect of these microbubbles on the T2 relaxation times of a water-based medium was measured for liposomes filled with different gases-nitrogen, argon, air, oxygen, xenon, neon, perfluoropentane, perfluorobutane, and sulfur hexafluoride. The air-filled, perfluoropentane-filled and the oxygen-filled liposomes demonstrated the largest effect on transverse-relaxation. The influence of pressure on both gradient-echo and spin-echo signal intensities for air-filled microbubbles was also evaluated. Pressure-induced changes in signal intensity were consistently observed for both the spin-echo and gradient-echo pulses sequences.

Contrast Media↗

Hepatic clearance of Sonazoid perfluorobutane microbubbles by Kupffer cells does not reduce the ability of liver to phagocytose or degrade albumin microspheres.

This study has been performed to examine which cells are responsible for the hepatic clearance of the new ultrasound contrast agent Sonazoid and to study whether uptake of these gas microbubbles disturbs the function of the cells involved. Sonazoid was injected into rats and perfused fixed livers were studied by electron microscopy, which revealed that the Sonazoid microbubbles were exclusively internalised in Kupffer cells, i.e. by the macrophages located in the liver sinusoids, and not by parenchymal, stellate or endothelial cells. This is the first demonstration of intact phagocytosed gas microbubbles within Kupffer cells. Uptake of the Sonazoid perfluorobutane microbubbles by the Kupffer cells following injection of a dose corresponding to 20x the anticipated clinical dose for liver imaging did not result in measurable changes in the uptake and degradation of radioactively labelled albumin microspheres previously shown to be a useful indicator marker for Kupffer cell phagocytosis.

Albumins↗

Myocardial contrast two-dimensional echocardiography: dose-myocardial effect relations of intracoronary microbubbles.

It is controversial whether echocardiographic contrast agents prepared by sonication cause transient myocardial depression beyond that known to occur with contrast agents alone. In nine open chest dogs, contrast injections were made into the left anterior descending coronary artery during two-dimensional echocardiography. One hundred forty-four recordings were analyzed subsequently, by an observer who was unaware of other data, for percent depression of systolic wall thickening, duration of regional wall motion abnormalities, peak contrast enhancement and contrast washout. Two microbubble sizes were obtained by sonicating Renografin-76 (meglumine sodium diatrizoate): mean diameter 12 +/- 3 (SEE) and 20 +/- 6 micron. Four doses (range 0.5 to 3 ml) of each of four agents (12 and 20 micron bubbles in Renografin, nonsonicated Renografin and saline solution) were injected in random order. Significant relations were found between percent depression of systolic wall thickening, duration of regional wall motion abnormalities and contrast washout time versus microbubble size (p less than 0.001) and microbubble dose (p less than 0.01). Little increased contrast effect was found at larger doses or with larger microbubbles compared with the smaller doses and size studied. Injections of nonsonicated Renografin caused less depression of systolic wall thickening (p less than 0.05), faster resolution of wall motion abnormalities (p less than 0.05), less contrast (p less than 0.001) and more rapid contrast washout (p less than 0.001) than did 12 micron bubbles in Renografin. A significant correlation was found between the duration of regional wall motion abnormalities and contrast washout time (r = 0.93, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Visually discernible myocardial echocardiographic contrast after intravenous injection of sonicated dextrose albumin microbubbles containing high molecular weight, less soluble gases.

OBJECTIVES: The central hypothesis of this study was that microbubble survival, and subsequent left ventricular and myocardial ultrasound contrast, could be improved by altering microbubble gas to consist of a higher molecular weight (less diffusible) and less soluble gas. BACKGROUND: Microbubble survival after intravenous injection is shortened because of rapid diffusion of blood-soluble room air gases (nitrogen and oxygen) across the permeable bubble membrane into blood. METHODS: Thirteen open chest dogs received intravenous injections of a constant dose of sonicated dextrose albumin that was incubated with either room air or 100% nitrogen, 100% helium or 100% sulfur hexafluoride. Nitrogen (100%) is less blood soluble than room air, whereas helium and sulfur hexafluoride are the least soluble. Sulfur hexafluoride has the slowest diffusion rate. To further decrease the diffusion rate, each sample was administered during inhalation of room air and again during brief inhalation of the same gas with which it had been incubated. RESULTS: The highest peak videointensity in the left ventricular cavity was produced by the sonicated dextrose albumin incubated with sulfur hexafluoride, the gas having lowest blood solubility and diffusion rate, while sulfur hexafluoride was briefly inhaled during the period of intravenous injection (peak videointensity 139 +/- 10 vs. 54 +/- 11 for room air-exposed sonicated dextrose albumin, p < 0.001). Myocardial contrast was visually evident in > 80% of the intravenous injections of sulfur hexafluoride-exposed sonicated dextrose albumin when the agent was given as an 8-fold concentrated sample during brief inhalation of sulfur hexafluoride. CONCLUSIONS: Visual myocardial echocardiographic contrast is possible after intravenous injection of sonicated dextrose albumin if the microbubbles contain a gas with low blood solubility and diffusivity.

Albumins↗