Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Survival of Listeria spp. on raw whole chickens cooked in microwave ovens.

The prevalence of microwave ovens in North American homes has increased dramatically within the last decade. Although microwave ovens are primarily used for reheating of foods, they are now more commonly being applied to the cooking of raw foods. Although cooking of raw foods, according to manufacturers' instructions targets an organoleptically acceptable end product, the process does not address the microbiological safety of the cooked food. Seventeen microwave ovens from various commercial suppliers were used to cook naturally contaminated whole raw broilers (< or = 1.8 kg) and roasters (> 1.8 kg) according to manufacturers' instructions. Temperature probes (six per chicken) were used to measure the temperature of chickens immediately after cooking and during the holding period. Of 81 Listeria-positive raw broilers and 93 raw roasters, 1 (1.2%) and 9 (9.7%), respectively, yielded viable Listeria spp. after microwave cooking. Of these, two were undercooked (visual inspection), one was over the maximum weight stipulated by the oven manufacturer and another one was over the maximum weight and undercooked. A significantly greater proportion of contaminated cooked birds was observed with roasters than with broilers, where for one of these contaminated roasters, the temperature at all six measured sites was > or = 87 degrees C. Most of the postcook Listeria-positive birds were associated with 2 of the 17 microwave ovens. Factors such as wattage, cavity size, and the presence or absence of a turntable seemingly did not play a significant role in the survival of Listeria spp. in microwave-cooked chicken. However, the general inability of microwave ovens to uniformly heat chicken carcasses was noted. In order to promote greater safety of microwave-cooked foods, general recommendations for consumers are provided.

Animals↗

Prospective randomized comparison of high energy transurethral microwave thermotherapy versus alpha-blocker treatment of patients with benign prostatic hyperplasia.

PURPOSE: We compare directly the efficacy and safety of targeted high energy transurethral microwave thermotherapy with alpha-blocker treatment for benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: In this randomized prospective study 52 patients with symptomatic BPH received terazosin and 51 underwent high energy transurethral microwave therapy with topical anesthesia. Patient evaluation included determination of International Prostate Symptom Score (I-PSS), peak flow rate and quality of life score before transurethral microwave therapy or terazosin and periodically up to 6 months thereafter. RESULTS: At 2-week followup the terazosin group transiently exhibited significantly greater improvement than the transurethral microwave therapy group in mean values of all 3 primary efficacy parameters of I-PSS, peak flow rate and quality of life score. At 12 weeks and 6 months this pattern was reversed, and the transurethral microwave therapy group achieved significantly greater improvement than the terazosin group in mean I-PSS, peak flow rate and quality of life score. By 6 months 78.4, 64.7 and 84.3% of the transurethral microwave therapy group demonstrated a 50% or greater improvement in I-PSS, peak flow rate and quality of life score, respectively, compared with 32.7, 9.6 and 40.4% of the terazosin group, respectively. Nine patients in the terazosin group and 1 in the transurethral microwave therapy group withdrew from study because of side effects or lack of treatment efficacy. CONCLUSIONS: Terazosin afforded more rapid improvement in symptoms, voiding function and quality of life in BPH patients. High energy transurethral microwave therapy offered markedly superior clinical outcomes at 12 weeks to 6 months.

Adrenergic alpha-Antagonists↗

Percutaneous microwave coagulation therapy for patients with primary and metastatic hepatic tumors during interruption of hepatic blood flow.

BACKGROUND: Although percutaneous microwave coagulation is relatively noninvasive therapy for patients with hepatic tumors, coagulation of tumors is sometimes incomplete and local recurrence occurs. The authors hypothesized that the cause of incomplete coagulation was a cooling effect in surrounding hepatic blood flow. To prove this hypothesis and to improve the efficacy of this therapy, they interrupted hepatic blood flow during the treatment and measured the amount of tumor tissue coagulated by microwave. METHODS: The authors first performed an animal experiment on pigs. After laparotomy, the liver of an anesthetized pig was coagulated by microwave with or without interruption of hepatic blood flow; the interruption was achieved by squeezing hepatic blood vessels. Next, the authors applied the microwave coagulation percutaneously to 25 human patients with primary or metastatic carcinoma in the liver with or without intraoperative temporary interruption of hepatic blood flow; the interruption was achieved by inflating balloon catheters inserted in the hepatic blood vessels through femoral vessels. RESULTS: The greatest dimension of area of normal liver tissue coagulated by microwave with blood flow interruption was significantly (P < 0.001) larger (18.8 +/- 1.0 mm, n = 4) than without it (9.8 +/- 1.7 mm, n = 4) in the experiment with pigs. In human hepatic tumors, the greatest dimension of the area coagulated by microwave with blood flow interruption was also significantly (P < 0.001) larger (41.1 +/- 9.3 mm, n = 14) than without it (26.9 +/- 8.5 mm, n = 11). The local recurrence rate of the tumor during a period of 6 months after the treatment was lower (P < 0.05) with blood flow interruption (7%) than without it (45%). CONCLUSIONS: Intraoperative interruption of hepatic blood flow increases the areas of primary and metastatic hepatic tumors coagulated by microwave. It is expected to increase the efficacy of percutaneous microwave coagulation therapy for patients with hepatic tumors.

Aged↗

Combination therapy with transcatheter arterial chemoembolization and percutaneous microwave coagulation therapy for hepatocellular carcinoma.

BACKGROUND: A small number of microwave electrode insertions and microwave irradiations were used to obtain complete tumor necrosis in hepatocellular carcinomas (HCC) measuring > 2.0 cm but </= 3.0 cm in greatest dimension. The efficacy of combining transcatheter arterial chemoembolization (TACE) with subsequent percutaneous microwave coagulation therapy (PMCT) was assessed in this study. METHODS: Eighteen patients with cirrhosis and HCCs measuring > 2.0 cm but </= 3.0 cm in greatest dimension underwent TACE followed within 1-2 days by ultrasonographically guided PMCT. RESULTS: On dynamic computed tomography, 17 of the 18 patients showed complete necrosis of their tumor lesions and the treated tumor margins (>/= 5 mm). Necroses of tumors and noncancerous margins surrounding the tumors were obtained using 4 microwave irradiations (1 session) in 14 patients, 5 microwave irradiations (2 sessions) in 2 patients, and 6 microwave irradiations (2 sessions) in 1 patient. The follow-up period was short (12-31 mos), and all patients remained alive. No local recurrences in the treated areas were detected. No fatal complications were observed. Pleural effusion was observed in 1 patient only. CONCLUSIONS: This combined therapy of PMCT applied within 1-2 days of TACE effectively treated HCCs measuring > 2.0 cm but </= 3.0 cm in greatest dimension. A small number of microwave electrode insertions and microwave irradiations were used.

Aged↗

[Sonographically guided percutaneous "air-cooled" microwave coagulation in live pig liver: an experimental study].

BACKGROUND & OBJECTIVE: Sonographically guided percutaneous microwave coagulation therapy has been widely used as an effective minimal invasive therapy for small liver cancer. However, high temperature of the shaft of the electrode blocks the advance of microwave coagulation in the treatment of liver cancer. The present study was conducted to investigate the prospect of the newly developed microwave coagulation equipment with "air-cooled" electrode in the treatment of liver cancer. METHODS: Six Pigs underwent hepatic coagulation at 60 W for 10 minutes, 60 W for 20 minutes, 80 W for 10 minutes, and 80 W for 20 minutes under US-guided percutaneous microwave coagulation using the "air-cooled" microwave coagulation equipment-ECO-100 Advanced Type. RESULTS: The experiment showed that the lesion size of microwave coagulation in single irradiation could be significantly enlarged when increasing the power output and exposure duration without the worry of high temperature of the shaft of the electrode. Microwave coagulation using the "air-cooled" electrode produced a necrosis volume of 4.0 cmx4.3 cm at 80 W for 10 minutes, 4.7 cmx5.2 cm at 80 W for 20 minutes. The "air-cooled" microwave coagulation did not leave a trail in the coagulation area. CONCLUSION: The technique of "air-cooled" electrode can decrease the temperature of the shaft of the electrode. The effectiveness could be improved through increasing the power output and exposure duration

Animals↗

[Studies on the microwave leakage of the interphone].

OBJECTIVE: To assay and study the microwave leakage of 4 types of interphones. METHODS: The radiation intensities of four types of 199 interphones were determined by the microwave leakage measure instrument of model ML-91 made in China. RESULTS: The average intensities of microwave leakage at a distance of 5 cm from aerial part and other parts of interphones during launching [(1 316.0 +/- 144.3), (971.0 +/- 131.6) microW/cm(2) respectively] were significantly higher than during waiting [(14.4 +/- 5.3), (13.2 +/- 4.9) microW/cm(2) respectively] (P < 0.01). The average intensities of microwave leakage at a distance of 50 cm from different parts were (357.3 +/- 27.8) microW/cm(2). The daily average intensity of microwave leakage to which the head, chest and abdomen exposed was (945.5 +/- 447.1) microW.h/cm(2) in total, that exceeded the hygienic standard of microwave in China (400 microW.h/cm(2)), during the normal communication by interphones. CONCLUSION: The microwave leakage was higher during launching than during waiting, and was the highest at the aerial part of the interphones. The microwave radiation of most interphones was higher than the current national standard. It may lead to potential effects on the owner of interphone, so protection against it should be made.

Cell Phone↗

The effect of 2450-MHz microwave radiation during microtubular polymerization in vitro.

Exposure to 2450-MHz (cw) microwave radiation causes inhibition of cell division in intact cells and varied in vivo biological effects in both avian and mammalian species. Because these reported effects may result from alterations in the dynamics of microtubule formation, we studied the effects of simultaneous microwave exposure (2450 MHz, cw) during each of the three critical stages of the intracellar polymerization cycle. In addition, using circular dichroism spectroscopy, we studied the effect of microwave irradiation on the secondary structure of purified tubulin polypeptides. These studies were accomplished using specially constructed exposure systems that permit the continuous recording of turbidometric or circular dichroism measurements during simultaneous exposure to microwaves. The baseline turbidity of microtubular protein did not change under the influence of microwave radiation (20 or 200 mW/g SAR) and irradiation had no effect on the light-scattering properties of the depolymerized protein. EGTA-induced polymerization and cold-induced depolymerization patterns were also similar for both control and microwave-irradiated samples. The circular dichroism spectrum of purified tubulin also did not appear to be influenced by microwave irradiation, indicating a lack of effect on the protein secondary structure. The data suggest that the cellular effects of microwaves are not due to changes in microtubular proteins or their rate of polymerization.

Animals↗

Evidence for genetic control of microwave-induced augmentation of complement receptor-bearing B lymphocytes.

The genetic control of 2450 MHz microwave-induced increase in complement receptor-bearing B lymphocytes (CRL) was studied using congenic, backcross, and recombinant inbred (RI) strains of mice. Mice were exposed to 2450 MHz microwaves (0.6 W; 10-14 W/kg) in an environmentally controlled waveguide and were assayed for CRL on days 3 or 6 post-exposure. Genetic studies of responder X nonresponder F1 mice and backcross analysis of nonresponder X (responder X nonresponder) F1 mice indicated that microwave susceptibility was controlled by a single, dominant Mendelian gene. Crosses between two nonresponder strains failed to restore the responder state. The dichotomy in microwave susceptibility between two strains congenic at the H-2--T1a region on chromosome 17 (AKR-responder and B.6-H-2k-nonresponder) indicated the noninvolvement of the Crl-1 gene and that the essential gene was located outside the H-2 region. This was confirmed by the responsiveness of the C3H-H-2o strain, which possesses a nonresponder H-2 haplotype and responder background genes. The strain distribution of microwave responsiveness in the BXH RI lines demonstrated that the microwave-induced increase in CRL was controlled by a single regulatory gene located on chromosome 5. We also analyzed the microwave responsiveness of two congenic strains of mice that possess different C3H/HeJ segments of chromosome 5 inserted into a C57BL/6J background. The JGBF/LeTy strain exhibited an increase in CRL indicating it possessed the segment of C3H/HeJ chromosome 5 that controls microwave responsiveness. The C57BL/6JTy-le strain remained nonresponsive. This places the essential regulatory gene to the right of the PgM-1 locus and to the left of the rd locus on chromosome 5.

Animals↗

Differential response of the permeability of the rat liver canalicular membrane to sucrose and mannitol following in vivo acute single and multiple exposures to microwave radiation (2.45 GHz) and radiant-energy thermal stress.

Both acute and chronic exposures to microwave radiation altered the function of the rat canalicular membrane. A single acute exposure to microwave radiation [80 mW/cm2, 2.45 GHz, continuous wave, 30 min exposure (SAR approximately equal to 72 W/kg)] or a matched radiant-energy thermal load, both designed to raise core body temperature approximately 3 degrees C, decreased the permeability of the canalicular membrane of male Sprague-Dawley rats to sucrose. The change in canalicular membrane permeability was demonstrated by a significant increase in the percentage of [3H]sucrose recovered in bile following its administration by a segmented retrograde intrabiliary injection. Similar acute exposures to microwave and radiant-energy thermal sources produced no significant alterations in canalicular membrane permeability to [14C]mannitol. In both acute exposure protocols, a rapidly reversible increase in bile flow rate was observed. Four exposures (30 min/day x 4 days) to either microwave radiation (80 mW/cm2) or a matched radiant-energy thermal load resulted in a significant depression in bile flow rate at normothermic temperatures. Animals receiving multiple exposures to microwave radiation had significant decreases in canalicular membrane permeability to both [3H]sucrose and [14C]mannitol, while similar exposure to radiant-energy thermal load alone altered canalicular membrane permeability to [3H]sucrose. An examination of the hepatic clearance of sucrose and mannitol following acute microwave exposure demonstrated no significant differences. Thus acute single exposure to microwave and radiant-energy thermal loads produced similar alterations in canalicular membrane permeability. Conversely, multiple exposures produced nonreversible changes in bile flow rate and canalicular membrane permeability, with microwave exposure producing greater alterations in the function of the canalicular membrane than an equivalent radiant-energy thermal load.

Animals↗

Selection of biological indicator for validating microwave heating sterilization.

For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

Bacteria↗

Temperature-programmed microwave-assisted synthesis of SBA-15 ordered mesoporous silica.

The currently available microwave technology permits the development and implementation of a temperature-programmed microwave-assisted synthesis (TPMS) of ordered mesoporous silicas (OMSs). Unlike in previously reported syntheses of OMSs, in which only the final hydrothermal treatment was carried out under microwave irradiation, this work takes advantage of the existing capabilities of modern microwave systems to program the temperature and time for the entire synthesis of these materials. To demonstrate the flexibility of the proposed microwave-assisted synthesis, besides programming two consecutive steps involving initial stirring of the gel at a lower temperature and static hydrothermal treatment at a higher temperature, we explored the possibility of temperature programming of the latter step. A major advantage of microwave technology is the feasibility of temperature and time programming, which has been demonstrated by the synthesis of one of the most popular OMSs, SBA-15, over an unprecedented range of temperatures from 40 to 200 degrees C. Since the synthesis of OMSs has not yet been explored and reported at temperatures exceeding 150 degrees C, this work is focused on the SBA-15 samples prepared at higher temperatures (such as 160, 180, and even 200 degrees C). These SBA-15 samples show better thermal stability than those synthesized at commonly used temperatures either under conventional or microwave conditions. Moreover, a partial decomposition of the template during high-temperature microwave-assisted syntheses does not compromise the formation of well-ordered SBA-15 materials. This study shows that the simplicity and capability of temperature and time programming in TPMS allows one not only to tune the adsorption and structural properties of OMSs but also to easily screen a wide range of conditions in order to optimize and scale-up their preparation as well as to significantly reduce the time of synthesis from days to hours.

Journal Article↗

Influence of microwave radiation on the growth of gold nanoparticles and microporous zincophosphates in a reverse micellar system.

The water core of reverse micelles has been extensively used as the site for synthesis of a variety of materials. However, water-in-oil reverse micelles have a limited range of temperatures over which they are stable as a single phase. Directing heat to the water cores, the usual site of synthesis without heating the bulk provides added opportunities for synthesis. Microwave radiation is a method for superheating the water cores. In this study, we use an H2O-sodium bis(2-ethylhexyl) sulfosuccinate (AOT)-heptane reverse micelle system for the synthesis of Au particles by hydrazine reduction of HAuCl4 in the presence and absence of microwave radiation. The duration of the microwave radiation was limited to a 2-min duration at a power of 300 W, thereby ensuring that the reverse micelle phase is maintained during the synthesis. At all hydrazine concentrations studied (0.5-2 M), the presence of microwave radiation led to an increase in the particle size of Au. The second system examined was the growth of microporous zincophosphate-X (ZnPO-X, an analogue of the faujasite structure) synthesized from H2O-dioctyldimethylammonium chloride (DODMAC)-heptane reverse micelle system. Microwave radiation was applied for 1 min at 150 W at various stages of the nucleation and growth process, and did not disrupt the reverse micelle system. Product analysis after 48 h of reaction showed that the 1-min microwave pulse, if applied during the nucleation stage (the first 4 h), promoted the formation of NaZnPO4.H2O over ZnPO-X. The effect of the microwave pulse at the growth stage was to promote the formation of ZnPO-X. Absorption of the microwave radiation by the water core and surrounding polar surfactant molecules leads to a rapid rise in local temperature (predicted to be approximately 150 degrees C/min for the AOT system), increasing the rates of intramicellar reactions.

Journal Article↗

Effect of microwave irradiation on antibody labeling efficiency when applied to ultrathin cryosections through fixed biological material.

To study the effect of microwaves on immunolabeling, ultrathin cryosections or diluted antibodies were irradiated prior to antibody application, and gold labeling was quantified. In addition, affinity purified, polyclonal antibodies and protein A-gold were applied to ultrathin cryosections of aldehyde-fixed material in the presence and absence of microwaves. Amylase, a soluble protein secreted by pancreatic acinar cells, MHC class II, an integral membrane protein, and 3-(2,4-dinitroanilino)-3-amino-N-methyldipropylamine (DAMP), an exogenously added antigen, were localized with monospecific antibodies. Each was chosen for their contrasting subcellular characteristics. Results demonstrated that for some antigens, antibody labeling efficiency was quantitatively improved by microwave irradiation of sections prior to antibody application. Irradiation of diluted antibodies prior to their application also resulted in improved labeling. In contrast, the results obtained using rapid immunolabeling protocols in the presence of microwaves resulted in labeling levels similar to those obtained in the absence of microwaves. We conclude that microwave irradiation can improve the labeling efficiency of some antibodies. However, improvements in labeling density are dependent on the antigen under study and on variable irradiation times, unique to each antibody. This suggests that the routine use of microwaves to reduce incubation times may not be a viable alternative to bench protocols.

Amylases↗

Quantitative changes in potassium, sodium, and calcium in the submaxillary salivary gland and blood serum of rats exposed to 2880-MHz microwave radiation.

Na+, K+, and Ca2+ concentrations in the blood serum and submaxillary salivary gland (SSG) were investigated in adult, male rats exposed to 2880-MHz microwaves modulated with 1.5-mus pulses at a pulse repetition rate of 1000 Hz or in a hyperthermal environment. Rats were exposed, one at a time, for 30 min to microwaves producing a specific absorption rate (SAR) of: 4.2, 6.3, 6.8, 8.4, 10.8, or 12.6 W/kg, or were sham exposed under similar environmental conditions. In a second series, one group of rats was exposed singly for 15, 30, or 60 min to microwaves producing an SAR of 9.5 W/kg and other rats were exposed for similar periods at 40 degrees C; and 10 rats were sham exposed. Flame photometric analysis indicated that the thresholds of microwave radiation required to induce a change in Na+, K+, and Ca2+ concentrations in the salivary glands are 6.8, 6.8, and 6.3 W/kg, respectively. The directions of Na+, K+, and Ca2+ ion shifts in exposed rats' salivary glands are similar, whether affected by microwaves or hyperthermia. Greater changes in Na+ and K+ concentrations in SSG of rats exposed to microwaves for 15 and 30 min were found than in those exposed at 40 degrees C. On the other hand, exposure to hyperthermia at 40 degrees C or to microwaves for 1 h caused Na+ concentration to be increased by 68.7 and 59.5% and K+ concentration to be decreased by 29.6 and 21.7%, respectively.

Animals↗

Effects of acute low-level microwaves on pentobarbital-induced hypothermia depend on exposure orientation.

Two series of experiments were performed to study the effects of acute exposure (45 min) to 2,450-MHz circularly polarized, pulsed microwaves [1 mW/cm2, 2-mus pulses, 500 pps, specific absorption rate (SAR) 0.6 W/kg] on the actions of pentobarbital in the rat. In the first experiment, rats were irradiated with microwaves and then immediately injected with pentobarbital. Microwave exposure did not significantly affect the extent of the pentobarbital-induced fall in colonic temperature. However, the rate of recovery from the hypothermia was significantly slower in the microwave-irradiated rats and they also took a significantly longer time to regain their righting reflex. In a second experiment, rats were first anesthetized with pentobarbital and then exposed to microwaves with their heads either pointing toward the source of microwaves (anterior exposure) or pointing away (posterior exposure). Microwave radiation significantly retarded the pentobarbital-induced fall in colonic temperature regardless of the orientation of exposure. However, the recovery from hypothermia was significantly faster in posterior-exposed animals compared to those of the anterior-exposed and sham-irradiated animals. Furthermore, the posterior-exposed rats took a significantly shorter time to regain their righting reflex than both the anterior-exposed and sham-irradiated animals.

Animals↗

Thermal action of 2.45 GHz microwaves on the cytoplasm of Chinese hamster cells.

In order to demonstrate possible specific effects of microwaves at the cellular level V-79 Chinese hamster cells were exposed to 2.45-GHz radiation at power levels of 20-200 mW/cm2 and at specific absorption rates of 10-100 mW/g. Intracellular cytoplasmic changes were observed by fluorescence polarization using a method based on the intracellular enzymatic hydrolysis of nonfluorescent fluorescein diacetate (FDA). At levels of absorbed energy below 90 J/g, modifications of microviscosity and mitochondrial state were absent, but a slight stimulation of enzymatic hydrolysis of FDA was observed which may be explained by microwave-induced alterations of cellular membranes possibly due to differences in heating pattern of microwaves compared to water-bath heating. At levels of absorbed energy above 90 J/g, the decrease of enzymatic hydrolysis of FDA, increase in degree of polarization, and increase of permeation of the fluorescent marker correlated well with the decrease in cell viability as measured by the exclusion of trypan blue. At equal absorbed energy, microwaves were found to exert effects comparable to classical heating except that permeation was slightly more affected by microwave than by classical heating. This suggests that membrane alteration produced by microwaves might differ from those induced by classical heating or that microwaves may have heated the membrane to higher temperatures than did classical heating.

Animals↗

Operant control of convective cooling and microwave irradiation by the squirrel monkey.

Adult male squirrel monkeys (Saimiri sciureus) were individually chair-restrained in an air-conditioned Styrofoam box in the far field of a horn antenna. Each monkey first received extensive training to regulate the temperature of the air circulating through the box by selecting between 10 and 50 degrees C air source temperatures. Then, to investigate the ability of the animals to utilize microwaves as a source of thermalizing energy, 2450-MHz continuous wave microwaves accompanied by thermoneutral (30 degrees C) air were substituted for the 50 degrees C air. Irradiation at each of three power densities was made available, ie, at 20, 25, and 30 mW/cm2 [SAR = 0.15 (W/kg)/(mW/cm2)]. The percentage of time that the monkeys selected microwave irradiation paired with thermoneutral air averaged 90% at 20 and at 25 mW/cm2. The mean percentage declined reliably (p less than 0.001) to 81% at 30 mW/cm2, confirming the monkey's ability to utilize microwave irradiation as a source of thermal energy during the course of behavioral thermoregulation. All animals readily made the warm-air to microwave-field transition, regulating rectal temperature with precision by sequentially selecting 10 degrees C air, then microwave irradiation accompanied by 30 degrees C air. Although the selection of cooler air resulted in a slight reduction of skin temperatures, normal rectal temperature was maintained. The results indicate that the squirrel monkey can utilize a microwave source in conjunction with convective cooling to regulate body temperature behaviorally.

Air Conditioning↗

Thermoregulatory responses of the immature rat following repeated postnatal exposures to 2,450-MHz microwaves.

This study was designed to determine the changes that occur in the thermoregulatory ability of the immature rat repeatedly exposed to low-level microwave radiation. Beginning at 6-7 days of age, previously untreated rats were exposed to 2,450-MHz continuous-wave microwaves at a power density of 5 mW/cm2 for 10 days (4 h/day). Microwave and sham (control) exposures were conducted at ambient temperatures (Ta) which represent different levels of cold stress for the immature rat (ie, "exposure" Ta = 20 and 30 degrees C). Physiological tests were conducted at 5-6 and 16-17 days of age, in the absence of microwaves, to determine pre- and postexposure responses, respectively. Measurements of metabolic rate, colonic temperature, and tail skin temperature were made at "test" Ta = 25.0, 30.0, 32.5, and 35.0 degrees C. Mean growth rates were lower for rats exposed to Ta = 20 degrees C than for those exposed to Ta = 30 degrees C, but microwave exposure exerted no effect at either exposure Ta. Metabolic rates and body temperatures of all exposure groups were similar to values for untreated animals at test Ta of 32.5 degrees C and 35.0 degrees C. Colonic temperatures of rats repeatedly exposed to sham or microwave conditions at exposure Ta = 20 degrees C or to sham conditions at exposure Ta = 30 degrees C were approximately 1 degrees C below the level for untreated animals at test Ta of 25.0 degrees C and 30.0 degrees C. However, when the exposure Ta was warmer, rats exhibited a higher colonic temperature at these cold test Ta, indicating that the effectiveness of low-level microwave treatment to alter thermoregulatory responses depends on the magnitude of the cold stress.

Age Factors↗