Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Assessing the aquatic hazard of commercial hydrocarbon resins.

Hydrocarbon resins are used to modify polymer products to achieve desired functional properties for a diverse range of products. These complex hydrocarbon-based mixtures are typically poorly soluble in water. However, resins may leach lower-molecular-weight monomers or impurities upon contact with water, thus posing a potential hazard to the aquatic environment. The bioavailability and toxicity of leachable constituents of four solid and three liquid resins were evaluated by analyzing water-accommodated fractions prepared with each resin, using biomimetic solid phase microextraction (SPME) techniques. Liquid resins exhibited concentrations of bioavailable constituents that were sufficiently elevated to cause acute toxicity to the aquatic organism Daphnia magna. All solid resins exhibited lower bioavailable concentrations of leachable constituents that were unlikely to pose an aquatic toxicity concern. Since observed toxicity of both resin types was generally consistent with bioavailable concentrations determined using SPME fiber measurements, it is concluded that this approach provides a convenient in vitro screening tool that can help reduce the use of animal testing in environmental hazard assessment of complex hydrocarbon-based substances.

Animal Testing Alternatives↗

Selective determination of polychlorinated biphenyls in waste oils using liquid-liquid partition followed by headspace solid-phase microextraction and gas chromatography with atomic emission detection.

A procedure for the determination of the total content of polychlorinated biphenyls (PCBs) in industrial oil samples using gas chromatography coupled to atomic emission detection (GC-AED) is presented. Analytes were extracted from the samples using dimethylsulfoxide (DMSO), this extract was diluted with water, and PCBs were concentrated on a PDMS-DVB solid-phase microextraction (SPME) fibre using the headspace (HS) mode. Fibres were thermally desorbed for 3 min in the splitless injection port of the GC-AED system. Influence of liquid-liquid extraction conditions on the performance of the analytical procedure is presented and the need of a sample oxidation step, previous to the extraction of the PCBs with DMSO, discussed. Working under optimal conditions, quantification limits from 0.5 to 1 microg/g (total PCBs content) were obtained for several Aroclor mixtures in transformer oil samples. The repeatability of the whole sample preparation procedure (liquid-liquid partition followed by headspace SPME and GC-AED determination) ranged from 4 to 7%.

Chromatography, Gas↗

Solid-phase microextraction for herbicide determination in environmental samples.

Liquid-liquid extraction or solid-phase extraction followed by gas chromatography (GC) or high-performance liquid chromatography are traditional herbicide residue determination methods for environmental samples. Solid-phase microextraction (SPME) is a solventless, fast, and sensitive alternative herbicide residue extraction method that can be applied to numerous environmental matrices. The objective of this paper was to review SPME literature regarding extraction theory, extraction modes, fiber types, and method optimization in conjunction with present and future SPME applications for herbicide determination in environmental samples.

Chromatography, Gas↗

Comparison of solid-phase microextraction and stir bar sorptive extraction for determining six organophosphorus insecticides in honey by liquid chromatography-mass spectrometry.

Two approaches based on sorptive extraction, solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE), in combination with liquid chromatography (LC)-atmospheric pressure chemical ionization mass spectrometry (MS) have been assayed for analyzing chlorpyriphos methyl, diazinon, fonofos, phenthoate, phosalone, and pirimiphos ethyl in honey. In both, SPME and SBSE, enrichment was performed using a poly(dimethylsiloxane) coating. Significant parameters affecting sorption process such as sample volume, sorption and desorption times, ionic strength, elution solvent, and dilution (water/honey) proportion were optimized and discussed. Performance of both methods has been compared through the determination of linearity, extraction efficiencies, and limits of quantification. Relative standard deviations for the studied compounds were from 3 to 10% by SPME and from 5 to 9% by SBSE. Both methods were linear in a range of at least two orders of magnitude, and the limits of quantification reached ranging from 0.04 to 0.4 mg kg(-1) by SBSE, and from 0.8 to 2 mg kg(-1) by SPME. The two procedures were applied for analyzing 15 commercial honeys of different botanical origin. SPME and SBSE in combination with LC-MS enabled a rapid and simple determination of organophosphorus pesticides in honey. SBSE showed higher concentration capability (large quantities of sample can be handled) and greater accuracy (between 5 and 20 times) and sensitivity (between 10 and 50 times) than SPME: thus, under equal conditions, SBSE is the recommended technique for pesticide analysis in honey.

Chromatography, Liquid↗

Methods for sampling and analysis of tropospheric ethanol in gaseous and aqueous phases.

In this paper, we report on techniques for sampling and measuring ethanol in both the gas and aqueous phases of the lower troposphere. In the gas phase, the best sampling conditions were ensured by adsorption on Hayesep Q with a Chromosorb W AW coated with LiCl dryer (method 1) or by cryogenic trapping (method 2). An intercomparison campaign showed good agreement between both methods under various conditions. Method 1 (adsorption on Hayesep Q with dryer) is easier to set up and to carry away from the laboratory. Method 2 (cryogenic trapping) requires longer sampling time (up to 60 min while method 1 requires only 10-15 min). Method 1 is adapted to high concentrations of ethanol (>20 ppb) and low relative humidity (<30%). Method 2 gives more accurate results than method 1 for low ethanol concentrations (1-20 ppb). Comparing these results to previous studies, it is clear that sampling with appropriate solid adsorbents or with stainless steel canisters (with appropriate humidified air and short storage time) is adapted to urban or industrial environments where ethanol concentrations are high. Cryogenic sampling must be preferred for remote places where ethanol concentrations are low. Three techniques were tested for sampling ethanol in the liquid phase, namely solid phase microextraction, purge and trap injection, and direct injection. Among those, the latter was chosen for field measurements of ethanol in rain samples at an urban location. These first ever results at an urban location show concentrations ranging from <1 to 5 microM in rains, which agree with the expected range of concentrations. However, the purge and trap method showed detection limits that were 50 times lower and should be preferred for liquid phase ethanol measurements in rural and remote locations. Combining cryogenic trapping for the gas phase (method 2) and direct injection for the liquid phase is convenient and well adapted for a multiphase study of ethanol in the atmosphere, where simultaneous measurements in both phases are needed.

Adsorption↗

Application of single drop microextraction for analysis of chemical warfare agents and related compounds in water by gas chromatography/mass spectrometry.

Retrospective detection and identification of chemical warfare agents (CWAs) is important from the verification point of view of the Chemical Weapons Convention. In the present work, a novel method for determination of CWAs and their markers in water has been described. It is based on a single drop micro extraction (SDME) of analytes and gas chromatography/mass spectrometric identification. Extraction conditions, such as solvent selection, agitation, extraction time, and salt content, were found to have significant influence on SDME. The conditions optimized for extraction of CWAs were 1 microL CH2Cl2/CCl4 (3:1 v/v), 30-min extraction time, 300-rpm stirring rate, and with or without NaCl addition. Under optimized conditions, comparison of SDME, solid-phase microextraction, and liquid-liquid extraction was also made. The limit of detection by SDME ranged from 75 to 10 microg L(-1) at a signal-to-noise ratio of 10:1.

Analytic Sample Preparation Methods↗

Analysis of free fatty acids in whey products by solid-phase microextraction.

To evaluate the impact of Cheddar cheese starter cultures on the level of free fatty acids in liquid whey, a solid-phase microextraction (SPME) technique was utilized. The determination of response factors relative to an internal standard and the verification of linearity over a wide concentration range allowed for the quantitation of free fatty acids in experimentally produced liquid whey and in a wide range of dry whey ingredients. Results indicated that whey produced with a Lactococcus lactis subsp. lactis starter culture contained the highest level of total free fatty acids with significantly higher levels of lauric, myristic, and palmitic acids. Significant declines in oleic, linoleic, and palmitic acid occurred during storage. Commercial whey ingredients demonstrated a linear increase in free fatty acids with increasing percent protein, except for whey protein isolate, which had the lowest concentration. The use of SPME for the rapid analysis of free fatty acids in whey products should allow for further research to determine the importance of these compounds on the quality and stability of whey products.

Cheese↗

On-line combination of aqueous-sample preparation and capillary gas chromatography.

Methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography (GC) comprise heartcut-orientated reversed-phase liquid chromatography-GC and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user-friendly, and many applications have been reported.

Chromatography, Gas↗

On-line combination of aqueous-sample preparation and capillary gas chromatography.

An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported.

Chromatography, Gas↗

Comparison of extraction techniques for gas chromatographic determination of volatile carbonyl compounds in alcohols.

Two extraction procedures, i.e. conventional liquid-liquid extraction (LLE) and liquid solid-phase microextraction (SPME) for extraction of the oximes formed after derivatization of carbonyl compounds with o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) in alcoholic solutions have been compared. The limit of detection for LLE followed by GC-ECD determination of C1-C6 was in the range of 0.23-3.3 microg/L, whereas for liquid SPME 0.005-0.33 microg/L. Both methods elaborated can be applied to the determination of carbonyl compounds present in spirits and alcoholic beverages.

Alcoholic Beverages↗

Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum.

A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.

Benzodiazepines↗

Study of erythromycin A decomposition products in aqueous solution by solid-phase microextraction/liquid chromatography/tandem mass spectrometry.

The decomposition of erythromycin A (EA) in aqueous solution was examined in the pH range 2-13 by means of combined solid-phase microextraction (SPME) and liquid chromatography/electrospray ionization tandem mass spectrometry. Degradation of EA, especially at lower pH values (pH < or = 3), was very rapid and yielded a wide variety of decomposition products. Identification of these degradation products was achieved by means of tandem mass spectrometry in the product ion and precursor ion scan modes. Anhydroerythromycin A was shown to be the major reaction product in both acidic and basic solutions. Among the different SPME fibers investigated for extraction from aqueous solutions, polydimethylsiloxane/divinylbenzene exhibited the best performance for EA and its degradation products.

Chromatography, Thin Layer↗

Determination of organic micropollutants in rain water for laboratory screening of air quality in urban environment.

Rain water may collect organic air pollutants, such as polycyclic aromatic hydrocarbons (PAHs), phthalate ester (PEs), pesticides, and polychrorinated biphenyls (PCBs), that could be present in air in consequence of different factors. The determination of these compounds in rain water samples consequently may be interesting for a first screening of air quality in urban and/or industrial areas. For this purpose, 3 areas of the city of Rieti (central Italy) were selected for rain water sampling: a) the city center, densely populated and with high road traffic; b) a suburban residential area; c) the industrial area, about 3 km out of the city center and along the state road. Wet-only precipitation collectors were used for sampling; solid-phase microextraction or liquid-liquid microextraction techniques followed by GC/MS determinations were applied for sample analysis. PCBs and pesticides were never found in the samples collected. On the contrary, some polycyclic aromatic hydrocarbons and phthalates were always found. Significant and seasonal differences in PAH levels were observed in the 3 different sampling areas, with higher values always found in the city center and during the winter period; on the contrary, PEs levels remained unchanged.

Air Pollutants↗

Analysis of anatoxin-a in biological samples using liquid chromatography with fluorescence detection after solid phase extraction and solid phase microextraction.

Anatoxin-a is a naturally occurring, potent neurotoxin produced by some species of cyanobacteria in freshwaters. This toxin, which is a potential health hazard, especially to animals, has been determined in different biological matrices such as several cyanobacterial cultures and water samples and carps and mussels tissue using a sensitive High Performance Liquid Chromatography with Fluorescence detection method. Sonication was the technique selected for the extraction of intracellular anatoxin-a and solid phase extraction using weak cation exchange was used for the concentration and purification of the samples. 4-Fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) was used to convert anatoxin into a highly fluorescent derivative. Recovery experiments were performed for each type of matrix used in this work, and adequate values were obtained (71-87%). Limits of detection for anatoxin-a were estimated to be in the ng/L and ng/g level for water and cyanobacterial samples, respectively. The results obtained were also compared with those obtained after using solid phase microextraction, as an alternative for the extraction and purification of the samples. Advantages and disadvantages regarding to the efficiency for impurities removal, simplicity and rapidity and the potential for concentration enhancement of using both methodologies have been also discussed.

Chromatography, High Pressure Liquid↗

Sensitive method for the determination of roxarsone using solid-phase microextraction with multi-detector gas chromatography.

We describe the development, optimization, and application of a novel method for the unequivocal identification and quantification of roxarsone (3-nitro-4-hydroxyphenylarsonic acid, 3-NHPAA) at low microg L(-1) levels. The method is based on capillary gas-liquid chromatography with parallel quadrupole ion-trap mass spectrometric (QIT-MS) and pulsed flame photometric detection (PFPD). The sensitive method couples the arsenic specificity of PFPD with the high selectivity of molecular MS for the determination of roxarsone, dimethylarsenic acid (DMAA), and monomethylarsonic acid (MMAA) in complex matrices. Analytes were derivatized based on the approach we previously reported [B. Szostek, J.H. Aldstadt, J. Chromatogr. A 807 (1998) 253 and D.R. Killelea, J.H. Aldstadt, J. Chromatogr. A 918 (2001) 169] for the reaction of organoarsenicals with 1,3-propanedithiol (PDT). The cyclic dithiaarsenolines formed were extracted from the sample matrix in the liquid phase by solid-phase microextraction (SPME). The optimized SPME conditions employed a 65 microm polydimethlysiloxane-divinylbenzene (PDMS-DVB) fiber, extraction temperature of 70 degrees C and fiber equilibration time of 15.0 min. The mass spectrum of the dithiaarsenoline of roxarsone showed a base peak that corresponded to the predicted structure at m/z 319 and the tell-tale peak of an arsenic compound derivatized with PDT at m/z 181. Further peaks at m/z 149 and 228 were observed and found to be unique to roxarsone, formed by an interesting internal rearrangement of the ONOH functionality. A linear calibration model was prepared for roxarsone over an environmentally relevant range (0.0-100 microg L(-1)) and a detection limit of 2.69 microg L(-1) (3sigma) was observed. The method was applied to several fortified environmental surface water samples (50 microg L(-1)) where the average recovery for roxarsone was 103+/-10.9%.

Calibration↗

Rapid analysis of tetracycline antibiotics by combined solid phase microextraction/high performance liquid chromatography/mass spectrometry.

The technique of solid phase microextraction (SPME) combined on-line with high performance liquid chromatography/mass spectrometry (HPLC/MS) has been applied to the analysis of seven tetracycline analogues. Rapid baseline separation was achieved in under 5 min using a short 3 microm RP-18e cartridge column. Optimisation of the SPME procedure is described including choice of extracting fibre and modification of the sample by heating or salting out of the analytes. Detection limits of 4-40 ng/mL were obtained for the various analogues from extracted aqueous samples and absolute amounts of analyte extracted by the method determined using external calibration. To demonstrate the applicability of the technique for real samples the extraction of tetracycline from milk is described.

Animals↗

Determination of distribution constants between a liquid polymeric coating and water by a solid-phase microextraction technique with a flow-through standard water system

This paper describes an optimized experimental system for determining water/polymer coating distribution constants and discusses the mechanism of extraction of high molecular weight compounds by poly(dimethylsiloxane) (PDMS). The proposed flow-through standard water generator eliminates errors associated with both losses of analytes to the system surfaces and limited sample volume. In addition, the errors caused by partial precipitation or poor dissolution of highly hydrophobic analytes during spiking of water when producing calibration standards are also eliminated. The target analytes are a range of polycyclic aromatic hydrocarbons (PAHs). The results demonstrate that absorption partitioning is the predominant mechanism of extraction of analytes into PDMS-coated fibers for all PAHs investigated regardless of molecular weight. There is a strong correlation between determined PDMS/water distribution constants (K(fw)) and literature K(ow) values for all PAHs.

Journal Article↗

Gas chromatography-mass spectrometry-based analytical strategies for fatty acid analysis in biological samples.

Fatty acids play critical roles in biological systems. Imbalances in fatty acids are related to a variety of diseases, which makes the measurement of fatty acids in biological samples important. Many analytical strategies have been developed to investigate fatty acids in various biological samples. Due to the structural diversity of fatty acids, many factors need to be considered when developing analytical methods including extraction methods, derivatization methods, column selections, and internal standard selections. This review focused on gas chromatography-mass spectrometry (GC-MS)-based methods. We reviewed several commonly used fatty acid extraction approaches, including liquid-liquid extraction and solid-phase microextraction. Moreover, both acid and base derivatization methods and other specially designed methods were comprehensively reviewed, and their strengths and limitations were discussed. Having good separation efficiency is essential to building an accurate and reliable GC-MS platform for fatty acid analysis. We reviewed the separation performance of different columns and discussed the application of multidimensional GC for improving separations. The selection of internal standards was also discussed. In the final section, we introduced several biomedical studies that measured fatty acid levels in different sample matrices and provided hints on the relationships between fatty acid imbalances and diseases.

Fatty Acids↗