Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Joint Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Septic arthritis caused by Chryseobacterium meningosepticum in an elbow joint prosthesis.

Chryseobacterium meningosepticum is a Gram-negative bacillus historically associated with meningitis and sepsis in premature neonates. Clinicians should suspect this organism when Gram-negative bacilli are seen on Gram-stain and culture, particularly in immunocompromised patients, and in cases of disrupted host tissue integrity. We report the first case of septic arthritis due to this organism.

Arthritis, Infectious↗

[Use of intraosseous implants in joint prosthesis of the hip].

The authors examine actual problems in total hip endoprostheses fixation and dwell upon solutions used up to date. The authors propose a new technique of prosthethic socket fixation based on endosseous implantology. This method should increase long term stability utilizing at the same time the immediate stability offered by methyl-methacrylate cement.

Animals↗

[A newly developed cementless elbow joint prosthesis].

Authors describe briefly the history of the development of elbow arthroplasty. They report on their experiences with the silicone, cementless, unconstrained elbow prosthesis developed by them and implanted in 23 cases during 3 years. The prosthesis is described, the operative indication and the problems of the operative technique are reviewed. On the basis of their results and the low number of complications this method of operation is suggested first of all for the successful treatment of elbows with rheumatoid arthritis.

Arthritis, Rheumatoid↗

Teicoplanin-containing cement spacers for treatment of experimental Staphylococcus aureus joint prosthesis infection.

Using a rabbit model of methicillin-resistant Staphylococcus aureus knee-prosthesis infection, we studied the efficacy of teicoplanin cement alone or in combination with systemic intramuscular (i.m.) injections of teicoplanin. Seven days after infection, surgical debridement and removal of the infected prostheses were performed, and five rabbits were randomly assigned to one of five different treatment groups: untreated controls, prosthesis replacement by drug-free cement spacer, prosthesis replacement by teicoplanin-loaded cement spacer (1.2 g of teicoplanin/40 g of cement), i.m. injections of teicoplanin (20 mg/kg of body weight, twice a day for 7 days), or systemic antibiotic treatment combined with teicoplanin-loaded spacers. The most effective regimen combined systemic teicoplanin and antibiotic spacers.

Animals↗

Combination of quinupristin-dalfopristin (Synercid) and rifampin is highly synergistic in experimental Staphylococcus aureus joint prosthesis infection.

We compared the efficacies of quinupristin-dalfopristin (Q-D; 30 mg/kg of body weight every 8 h) and vancomycin (60 mg/kg twice daily), alone or in combination with rifampin (10 mg/kg twice daily), in a rabbit model of methicillin-resistant Staphylococcus aureus knee prosthesis infection. In contrast to vancomycin, Q-D significantly reduced the mean log(10) CFU per gram of bone versus that for the controls. The combination of rifampin with either Q-D or vancomycin was significantly more effective than monotherapy.

Animals↗

[Complications following cementing of joint prosthesis].

The authors studied changes in the level of lactate dehydrogenase during insertion of hip prostheseis fixed with methyl methacrylate cement. Thirty patients were studied here. In 23 of them, the L.D.H. isoenzymes were estimated. The variations in these enzymes appear 3 hours after the second fixation with cement: rise in L.D.H., isoenzyme 5, (of skeletal muscle origin) of isoenzymes 3 and 4, (of pulmonary origin). This is a sign of pulmonary involvement even in the absence of clinical signs.

Adult↗

Efficacy of sparfloxacin and autoradiographic diffusion pattern of [14C]Sparfloxacin in experimental Staphylococcus aureus joint prosthesis infection.

Using a new rabbit model of methicillin-susceptible Staphylococcus aureus knee prosthesis infection, we compared the efficacies of sparfloxacin (50 mg/kg of body weight subcutaneously, twice a day) and pefloxacin (50 mg/kg subcutaneously, twice a day). A partial knee replacement was performed with a silicone implant fitted into the intramedullary canal of the tibia, and 5 x 10(7) CFU of methicillin-susceptible S. aureus was injected into the knee. The 7-day treatment regimen was started 15 days later. The MICs and MBCs of sparfloxacin and pefloxacin were, respectively, 0.06 and 0.25 microgram/ml (MIC) and 0.25 and 1 microgram/ml (MBC). The peak levels of sparfloxacin and pefloxacin in serum were 3.6 and 21 micrograms/ml, respectively. Three weeks after the end of treatment, animals were sacrificed and tibias were removed, pulverized, and quantitatively cultured. In contrast to pefloxacin (3.61 +/- 1.64 log10 CFU/g of bone), sparfloxacin significantly reduced the bacterial density (2.12 +/- 1.1 log10 CFU/g of bone) (P = 0.01) in comparison with the level in controls (4.59 +/- 1.21 log10 CFU/g of bone), without selection of resistant variants. Sparfloxacin was significantly more effective than pefloxacin (P = 0.025). The autoradiographic pattern of [14C]sparfloxacin diffusion was studied in noninfected animals with prostheses and in infected animals 15 days after inoculation. Sixty minutes after completion of infusion of 250 microCi of [14C]sparfloxacin, in infected animals the highest levels of radioactivity were detected around the prosthesis, in femoral cartilage, and in articular ligaments. Radioactivity was slightly less intense in bone marrow and muscles and was very weak in compact bone. The distribution of sparfloxacin in uninfected rabbits was similar. Thus, sparfloxacin may represent a valid alternative therapy in these infections provided that it is carefully monitored for potential side effects.

Animals↗

Application of I(125) brachytherapy combined artificial joint prosthesis in malignant osteo- and soft-tissue sarcoma.

OBJECTIVES: The aim of this study was to evaluate the brachytherapy effectiveness of I(125) seeds combined with artificial prosthesis in malignant sarcoma therapy. METHODS: The combination of I(125) seeds and artificial prosthesis was implanted to replace tumor section for three clinical cases-2 malignant osteosarcoma patients and 1 malignant soft-tissue tumor patient- through the direct operation. RESULTS: Approximately 14-18 months after the operation, the results of our post-operational investigation showed that the tumor tissues of 3 patients had been completely removed. The limb functions recovered well. The brachytherapy of the combination of I(125) seeds and artificial prosthesis in malignant tumor improved the curative effect. No tumor existed, and no infection occurred. CONCLUSIONS: It was demonstrated that this method was safe and easy. No side-effect was observed after the implantation of I(125) seeds. The brachytherapy was proven to be a potential method for patients who were at high risk to recrudesce the malignant osteosarcoma of tumors after the tumor excision.

Adolescent↗

Sinus histiocytosis mimicking metastatic melanoma in lymph nodes of a patient with a large joint prosthesis: case report and review of the literature.

Malignant melanoma metastases to regional lymph nodes may be mimicked by several non-neoplastic processes, including sinus histiocytosis induced by fragments shed from joint prostheses. A patient who had an elective lymph node dissection for malignant melanoma and was found to have "post-prosthesis lymph node histiocytosis" resembling metastatic disease is described. Knowledge of the patient's past history of a total shoulder joint replacement along with the use of polarized light microscopy to identify birefringent particles of prosthetic debris allows for an accurate histologic diagnosis.

Aged↗

[St. George's model of total elbow-joint prosthesis].

The elbow-prosthesis, design St. George, a hinge prosthesis is developed according to the principle of the Low Friction Arthroplasty. Only small resection of the joint is necessary so that in the "second line of defence" a resection-arthroplasty of elbow is possible. The experiences on 44 implanted prosthesis and the results of 37 cases are described. Restriction of motion, pain, instability and ankylosis in case of rheumatiod arthritis and posttraumatic arthrosis were the main indications.

Adult↗

Subjective and objective outcomes in patients reconstructed with a custom-fitted alloplastic temporomandibular joint prosthesis.

PURPOSE: This study looked at prospective subjective and objective preoperative and postoperative outcome data from a set of multiply operated, anatomically mutilated, functionless, chronic temporomandibular joint (TMJ) pain patients who have undergone TMJ reconstruction with a custom-fitted prosthetic system. PATIENTS AND METHODS: Two hundred fifteen patients (363 joints: 296 bilateral, 67 unilateral) who had undergone total TMJ reconstruction with a custom-fitted TMJ prosthesis (Techmedica; now TMJ Concepts, Camarillo, CA) made up the subjects reviewed in this study. The mean follow-up period was 30.7 months. The patients were divided into 3 groups based on the number of prior unsuccessful TMJ arthrotomies they had undergone (group 1 = 0 to 2; group 2 = 3 to 8; and group 3 = 9 or more) RESULTS: Subjective improvement ratio data indicated that postoperatively group 1 had a 61.3% improvement in subjective parameters, group 2 had a 51.0% improvement, and group 3 had only a 27.5% improvement. Objective improvement ratio data showed that postoperatively group 3 had the largest increase in maximum interincisal opening, whereas the other groups had less improvement. CONCLUSION: The data from this study confirm, as previously reported in the literature, that the greater the number of surgical procedures performed on the TMJ, the less the chance of significant subjective improvement.

Adult↗

[Several years' experience with thumb saddle joint prosthesis by the de la Caffinière method].

This type of endoprosthesis was used for four years in chronically painful idiopathic osteoarthritis of the carpometacarpal joint of the thumb. Our results match exactly those published by the originator of the endoprosthesis CAFFINIERE, i.e. 70% excellent results, nearly 30% problem cases. The problem of loosening of the stem or the cup of the prosthesis seems to depend in our cases on the operative technique rather than on the design or other factors. In the rheumatoid patient as well as in polyarthrotic hands we cannot encourage the prosthetic replacement of the carpometacarpal joint of the thumb.

Aged↗