Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Image Enhancement”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Abnormalities of the contrast re-circulation phase in cerebral tumors demonstrated using dynamic susceptibility contrast-enhanced imaging: a possible marker of vascular tortuosity.

Dynamic susceptibility contrast-enhanced magnetic resonance (MR) imaging in tumors is restricted by relaxivity effects, which may obscure any abnormality of first-pass kinetics in the re-circulation phase. The purposes of this study were a) to document the magnitude of relaxivity effects with a variety of commonly used MR susceptibility imaging techniques; and b) to determine whether the re-circulation phase of the first-pass curve in tumors differs from that in normal tissue. We have confirmed that residual relaxivity effects can be eliminated from dynamic susceptibility contrast-enhanced data by several techniques. Application of these methods to enhancing vascular tumors allows detection of abnormalities in the re-circulation phase, which would otherwise be obscured. These abnormalities are independent of relative cerebral blood volume (rCBV) and presumably represent deviations from the predicted gamma variat flow pattern seen in normal tissues. We believe that the parameter rR described here provides an indicator of the chaotic nature of neovascular angiogenesis, which may be of benefit in diagnosis and management.

Brain↗

Motion-corrected free-breathing delayed enhancement imaging of myocardial infarction.

Following administration of Gd-DTPA, infarcted myocardium exhibits delayed enhancement and can be imaged using an inversion-recovery sequence. A conventional segmented acquisition requires a number of breath-holds to image the heart. Single-shot phase-sensitive inversion-recovery (PSIR) true-FISP may be combined with parallel imaging using SENSE to achieve high spatial resolution. SNR may be improved by averaging multiple motion-corrected images acquired during free breathing. PSIR techniques have demonstrated a number of benefits including consistent contrast and appearance over a relatively wide range of inversion recovery times (TI), improved contrast-to-noise ratio, and consistent size of the enhanced region. Comparison between images acquired using segmented breath-held turbo-FLASH and averaged, motion-corrected, free-breathing true-FISP show excellent agreement of measured CNR and infarct size. In this study, motion correction was implemented using image registration postprocessing rather than navigator correction of individual frames. Navigator techniques may be incorporated as well.

Algorithms↗

[Digital radiographic image enhancement in bone diagnosis--initial clinical results].

34 patients with skeletal alterations mostly in the periphery were investigated by digital image intensifier radiography (DIIR). A high resolution image-intensifier system (1024 x 1024 matrix, 40 cm, 28 cm, 14 cm image intensifier, maximal spatial resolution: 3.6 lp/mm) was available. The image quality was diagnostic sufficient in 76% using DIIR. A good or very good image quality of fine-structures was obtained only in 41%. The quality deficits in comparison to conventional radiograms were particularly obvious in investigation of the phalangeals. Logarithmic amplification and software upgrading lead after these first clinical investigations to a better image quality.

Adult↗

Biologic significance of false-positive magnetic resonance imaging enhancement in the setting of ductal carcinoma in situ.

BACKGROUND: Imaging patterns of benign proliferative processes often complicate the assessment of ductal carcinoma in situ (DCIS) by magnetic resonance imaging (MRI). We investigated the pathologic and biologic characteristics of false positive enhancement by breast MRI. METHODS: DCIS (n = 45), benign (n = 5), and false-positive (MRI enhancement and nonmalignant pathology) (n = 10) cases were characterized by immunohistochemistry and MRI features. RESULTS: For DCIS cases, images that overestimated pathologic size had heterogeneous enhancement on MR, were estrogen receptor positive, and were low grade by pathology. False-positives had higher rates of proliferation, angiogenesis, and inflammation compared with benign tissue but lower values than DCIS. Benign proliferative processes accounted for all false-positive and size overestimated cases. CONCLUSIONS: Lesions that enhance on MRI have higher proliferation, angiogenesis, and inflammation compared with nonproliferative breast tissue. Benign proliferative processes often enhance on MRI and are difficult to differentiate from low-grade, ER+ DCIS lesions. False-positive MRI enhancement may reflect a spectrum of change within high-risk tissue.

Antigens, CD↗

Myocardial delayed enhancement imaging using inversion recovery single-shot steady-state free precession: initial experience.

PURPOSE: To evaluate the feasibility of using an inversion recovery single-shot steady-state free precession (SS_SSFP) sequence for myocardial delayed enhancement (MDE) imaging, and to compare SS_SSFP with the conventional inversion recovery segmented fast gradient echo (IR_FGRE) technique. MATERIALS AND METHODS: Ten subjects (four volunteers and six patients with suspected or known coronary disease) were included in this study. All subjects were scanned with both IR_FGRE and SS_SSFP sequences 15-25 minutes after gadopentetate dimeglumine injection. Overall image quality, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) between the two techniques were compared. RESULTS: Compared to IR_FGRE, SS_SSFP exhibited adequate image quality (average scores = 3.8 for IR_FGRE and 3.9 for SS_SSFP) with much shorter acquisition time (14.4 seconds for IR_FGRE and 1.3 seconds for SS_SSFP). SS_SSFP images showed higher SNRs (P < 0.05) and less motion artifact from breathing. Enhanced myocardium was detected by both techniques in three patients, but the image sharpness is compromised in SS_SSFP images. CONCLUSION: SS_SSFP provides adequate image quality compared to IR_FGRE, while requiring a much shorter acquisition time. It is feasible to use SS_SSFP as an alternative method for MDE imaging, especially in patients who have difficulty with holding their breath.

Aged↗

[Evaluation of AMI-25 enhanced MR imaging and enhanced helical CT for liver tumors].

To evaluate the diagnostic capability of superparamagnetic iron oxide enhanced MRI and enhanced helical CT, 17 patients with histologically or clinically diagnosed hepatocellular carcinoma or metastatic liver tumor and a total of 208 nodules were studied. The pulse sequences used were SE 500/20 (T1WI), SE 2000/20 (PDWI) and SE 2000/70 (T2WI). Contrast medium was administrated intravenously for more than 30 minutes at a dose of 10 mumoles Fe/kg. Enhanced MR images were obtained 30-90 minutes after the injection of contrast medium. With helical CT, 133 nodules were detected. With unenhanced MRI, 62 were detected on T1WI, 60 on PDWI and 77 on T2WI. On the other hand, with enhanced MRI, 165 were detected on T1WI, 190 on PDWI and 186 on T2WI. Enhanced MRI revealed the most nodules among these images (P < 0.05), and was especially effective in detecting small nodules less than 10 mm in diameter (P < 0.05). In conclusion, it was considered that superparamagnetic iron oxide enhanced MRI was useful for the detection of hepatic nodules and that the most adequate pulse sequence was PDWI.

Aged↗

[Development of an automated patient-recognition method for digital chest radiographs using edge-enhanced images].

It is important that all images in a picture archiving and communication system (PACS) environment should be stored in the correct location, e.g., in the proper patient's folder. However, if patient information, such as identification number or patient name, has been entered incorrectly, the image may be stored in the wrong place. We are developing an automated patient recognition method for chest radiographs based on a template-matching technique to prevent such filing errors. To further improve the performance of our method, we investigated the usefulness of a new automated patient-recognition method based on a template-matching technique by using edge-enhanced and smoothed images. We found that the relationship between the correlation values obtained with and without the edge-enhancement technique tended to provide different criteria for identifying correct or incorrect patients. When we combined the two methods to distinguish the images by a rule-based method, 67.1% of wrongly identified patients in our database could be identified as wrongly identified, without any false warnings for correctly identified patients. We consider that this automated method for patient recognition based on edge-enhanced images would be useful in preventing "wrong" images from being stored in a PACS environment.

Databases, Factual↗

A practical method of image enhancement by interactive digital filtering.

A generalized form of the Wiener digital filter is described in which the user interactively varies two filter parameters to produce any desired number of filtered versions of a given image with differing blends of sharpening and smoothing qualities. Filtering is performed sufficiently rapidly, even without use of an array processor, to make application of the filter truly interactive. Use of the filter is illustrated with typical nuclear medicine images.

Bone and Bones↗

Craniospinal magnetic resonance imaging enhanced with Gd-DTPA in von Hippel-Lindau disease.

The case presented illustrates the utility of enhancement with gadolinium diethylenetriaminepenta-acetic acid in magnetic resonance imaging (MRI) of the brain and the spinal cord in a patient with von Hippel-Lindau disease. The patient had numerous lesions in the brain stem and the cervical and the thoracic spinal cord, most of which were not demonstrated or were only poorly demonstrated with noncontrast MRI. Contrast-enhanced MRI should be performed in two sessions with a separate dose of contrast agent for each. Regular follow-up examinations should be conducted in the same manner.

Adult↗

Interactive image enhancement and analysis of prometaphase chromosomes and their band patterns.

An interactive computer system for measuring banding patterns on prometaphase and prophase chromosomes is described. Cells are digitized, and the images are enhanced by digital filtering. A chromosome's medial axis is determined either automatically by a skeletonization procedure or interactively by an operator. A straightened image of a bent chromosome is made by straightening the axis without distorting its length. Landmark bands on the straightened image can be labeled interactively by the operator. Sets of labeled homologous chromosomes can be normalized to have the same apparent interlandmark spacing and can be displayed side by side for visual comparison.

Animals↗

Image enhancement. Developing a program for perioperative nurses.

An image campaign focuses on the strengths of nurses to promote nursing, and in doing so, helps nurses rediscover the values and commitment that are at the heart of the profession. Nursing's image will change when nurses themselves change.

Attitude of Health Personnel↗