Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ICSH”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Laboratory evaluation of the Sysmex SE-9500 automated haematology analyser.

The Sysmex SE-9c500 is a new, fully automated haematology analyser, providing a complete blood count (CBC), including a five-part differential count (DC), with flagging of morphological abnormalities. The SE-9500 was evaluated according to guidelines published by the International Committee for Standardisation in Haematology (ICSH). The results demonstrated minimal carryover (< 0.01%) and excellent linearity for WBC, RBC, HGB and platelet (PLT) (r > 0.995). Samples were stable with regard to CBC parameters after storage for up to 48 h at room temperature (RT) and 4 degrees C. Imprecision was generally acceptable for all CBC parameters (CV < 5%). Correlation between the SE-9500 and reference methods was excellent (r > 0.97) for all the major CBC parameters (WBC, RBC, HGB, PLT). There was minimal interference for WBC, RBC, HGB and PLT at high concentrations of bilirubin (BIL=224 micromol/l) or triglyceride (TG=7.78 mmol/l). SE-9500 reference values for CBC parameters are presented. Our results indicate that the SE-9500 is an excellent tool for routine haematological examination.

Adult↗

Reference intervals and age-related changes for platelet count, mean platelet volume and plateletcrit in healthy pre-weaning piglets in Italy.

Platelet count (PLT) mean platelet volume (MPV) and plateletcrit (PCT) were determined for 117 Landrace x Large White piglets aged 3-21 days; counts were performed with an automated blood cell counter (ABX Pentra 120). Reference values were estimated following the guidelines of the International Federation of Clinical Chemistry (IFCC) and the International Committee for Standardization in Haematology (ICSH). The calculated central 95% reference limits for PLT was 49.9-516.2 x 10(9)/1, for MPV 6.71-9.91 fl and for PCT 0.009-0.395%. When observations are divided into three age groups (about 1 week each) there is an increase in mean PLT count and PCT in 2-week piglets, and a decrease in MPV from the first to the third week of life. These reference values provide guidelines for interpreting for experimental and clinical observations, as well as for monitoring of the health status of similar aged piglets determined using automated impedance-light focusing methodology.

Age Factors↗

Report on the Fifth International Society of Blood Transfusion Platelet Serology Workshop.

The Fifth International Society of Blood Transfusion (ISBT) Platelet Serology Workshop took place in 1990. A total of 21 laboratories participated in the wet workshop. Results were discussed at a meeting of the International Committee on Standardization in Haematology (ICSH) Expert Panel on Platelet Serology at the Joint Congress of the ISBT and the American Association of Blood Banks in Los Angeles in November 1990. Each of the participants analyzed 37 serum samples for platelet-reactive alloantibodies and isoantibodies. In addition, two drug-dependent (quinine) platelet-specific antibodies had to be identified among a subset of seven sera. For the first time in a platelet serology workshop, five platelet suspensions had to be typed for the alloantigens of the HPA-1, -3, -4, and -5 systems.

Antibodies↗

[Endocrinological and histomorphological studies of testicular atrophy in myotonic dystrophy (author's transl)].

Testicular atrophy in myotonic dystrophy is caused by a primary and progressive atrophy of the seminiferous tubules. Endocrinological studies with synthetic LH(ICSH)-RH in two patients demonstrated the complete absence of FSH feed back mechanism. Glycogen content was markedly diminished or completely absent, as demonstrated histochemically, both in the morphologically intact and in damaged tubules. The endocrinological and morphological results both demonstrate that insufficiency of the Sertoli cells is the primary damage in the pathogenesis of testicular atrophy in myotonic dystrophy.

Adrenocorticotropic Hormone↗

Characteristics of the external quality assessment (EQA) scheme for haematology in Spain.

Ensuring reliable results of the tests which are performed in large haematology laboratories is essential because of the problems resulting from the use of complex automated instruments and the ever increasing workload. The Spanish Haematology EQA Scheme started in 1984 with 56 laboratories, a number which rose to 332 in 1989. The general scheme follows the guidelines established by the International Committee for Standardization in Haematology (ICSH) with participants from Public Health (57.9%) and Private (42.1%) laboratories. Surveys are performed monthly and on each occasion the following samples are prepared and sent by the Organizing Center (Haematology Laboratory Department, Hospital Clinic i Provincial of the University of Barcelona): whole blood for full blood counts (FBC), platelet suspensions (or equine total blood) and lyophilized plasma for prothrombin time (PT), partial thromboplastin time (PTT) and fibrinogen (F). After preparation, control materials are sent to participant laboratories where the requested tests are performed and the results reported back to the Organizing Center for statistical analysis. For result evaluation, laboratories are divided into four to eight groups depending on the methodologies used. Individuals results are assessed against a consensus value (mean) deviation index (DI) from the mean, coefficient of variation (CV) and Youden diagram for all results and groups of each parameter. Between 58.3 and 74.5% of laboratories responded. For WBC, the CV improved from 17 to 7%, for platelets from 34.4 to 24.3%. For coagulation tests CV was 18.1% for PT, 16% for PTT, and 26% for fibrinogen.(ABSTRACT TRUNCATED AT 250 WORDS)

Clinical Protocols↗

Erythrocyte pyruvate kinase deficiency: 11 new cases.

Eleven new cases of red cell pyruvate kinase (PK) deficiency with congenital haemolytic disease from 10 unrelated Italian families were characterized using the methods recommended by the International Committee for Standardization in Haematology (ICSH). All patients were double heterozygotes for the PK gene. The 10 variants were designated PK 'Lecce,' 'Parma,' 'Verona,' 'Milano,' 'Soresina,' 'Macerata,' 'Sassari,' 'Genova,' 'Mantova' and 'Brescia.' PK 'Sassari' was associated with glucose-6-phosphate dehydrogenase deficiency in two siblings. All mutants displayed multiple biochemical abnormalities except for PK 'Lecce' that only showed decreased red cell PK activity. No relation was found between the severity of anaemia and either the residual PK activity or specific biochemical enzyme abnormalities. Increased serum ferritin levels were detected in most of the patients, suggesting the need for systematically monitoring iron status in this disease.

Adolescent↗

A pyruvate kinase variant with an increased affinity for phosphoenolpyruvate in an individual with congenital non-spherocytic haemolytic anaemia.

A red-cell pyruvate kinase (PK) variant from an individual with congenital non-spherocytic haemolytic anaemia was characterized according to the procedure recommended by the International Committee for Standardization in Haematology (ICSH 1979). Activity of the mutant enzyme in haemolysates was one fifth of that found in normal control subjects. The electrophoretic mobility and thermostability of the mutant enzyme were lower than those of the normal enzyme and its apparent affinity for phosphoenolpyruvate was higher.

Adenosine Triphosphate↗

An evaluation of the Cell-Dyn 1000.

The Cell-Dyn 1000 is a new eight parameter fully automatic cell counter. This was evaluated following the ICSH guidelines. Scientific evaluation was generally satisfactory, largely conforming to the manufacturer's specifications. A number of potential microbiological safety hazards were noted; many could be overcome by minor modifications. Throughput and start-up/close-down times were acceptable. However, the reliability of the tested machine was felt to be less than satisfactory although this may be corrected by further minor machine modifications.

Blood Cell Count↗

Comparison of microcolumn chromatography and laser densitometry of isoelectric focusing strip for the quantitation of Hb A2 and Hb S.

Anion exchange microcolumn chromatography is the ICSH (1978) recommended procedure for the quantitation of Hb A2 and Hb S. The use of isoelectric focusing (IEF) followed by laser densitometry of the separated haemoglobin bands is evaluated as a quick and reliable method for quantitation for Hb A2 and Hb S. A paired comparison of 35 specimens, 25 normal and 10 with beta thalassaemia trait, were quantitated for Hb A2. The two groups were well separated by both procedures and Hb A2 levels were similar (r = +0.93, P less than 0.001). In addition, paired analyses of 30 specimens, 20 sickle cell trait and 10 with sickle cell trait combined with alpha thalassaemia, were quantitated for Hb S. The two groups were also well separated by both procedures and Hb S levels were similar (r = +0.94, P less than 0.001). In conclusion, IEF followed by laser densitometry appears to be a reliable, quick procedure for the screening of populations at risk from beta thalassaemia and populations at risk from sickle cell trait, with or without alpha thalassaemia interaction.

Chromatography, DEAE-Cellulose↗

The effect of red cell shape on the measurement of red cell volume. A proposed method for the comparative assessment of this effect among various haematology analysers.

Shape changes of abnormally deformed red cells in aperture impedance haematology analysers are known to affect MCV, MCHC and haematocrit estimation. However, different counters vary in the manifestation of this effect. We performed a comparative study among five analysers. Three of them are based on impedance without hydrodynamic focusing (Coulter STKR, Cell-Dyn3000 Abbott and K-1000 Sysmex). The other two use hydrodynamic focusing, either with impedance (NE-8000 Sysmex) or two angle laser scatter (H*1 Bayer). A novel method of analysis was applied. Two hundred and three specimens with abnormal red cells and 50 normal specimens (according to ICSH criteria) were assayed. In all samples the PCV was estimated by the reference method without correction for trapped plasma. A true MCHC value was estimated from the mean haemoglobin value and the PCV. The shape effect was assessed by three linear regressions: 1) haematocrit deviations from PCV (corrected for any calibration bias) versus true MCHC; 2) analyser MCHC vs. true MCHC; 3) MCV vs. MCH. The regressions for the analysers with hydrodynamic focusing indicated no significant shape effect. Aperture impedance analysers without focusing varied in their behaviour. The Coulter STKR and the Cell-Dyn3000 both showed strong correlation of haematocrit deviations with true MCHC, poor MCHC correlations and linear MCV-MCH regressions. The K-1000 showed minor indications of such an effect. We conclude that comparative studies are needed to quantitate red cell shape effect errors among various impedance analysers.

Bias↗

Red-cell enzyme activities and properties of mutant pyruvate kinase after 1-year storage in a -80 degrees C freezer.

Red cells from 5 healthy adults and an unstable mutant pyruvate kinase (PK), PK Maebashi, were stored for 12 months in a -80 degrees C freezer. With an exception of triosephosphate isomerase and phosphoglycerate kinase activities, normal red-cell enzyme activities remained essentially unchanged. Mutant PK was characterized by the methods recommended by the International Committee for Standardization in Haematology (ICSH). Normal control and PK Maebashi remained essentially unchanged in their characteristics after storage in a -80 degrees C freezer for 12 months. These results indicate that the red cells stored over a long term in a -80 degrees C freezer can be used for the study of unstable mutant PK.

Blood Preservation↗

Review of the problems involved in using enzymes in blood group serology--provision of freeze-dried ICSH/ISBT protease enzyme and anti-D reference standards. International Council for Standardization in Haematology. International Society of Blood Transfusion.

Proteolytic enzyme preparations and techniques used routinely in blood group serology for the detection of atypical patient antibodies prior to transfusion vary widely and are often poorly standardised. Recent advances have been made in the use of biochemical methods to standardise and stabilise the potency of the enzyme preparations used. A joint working party of the International Council for Standardization in Haematology (ICSH) and the International Society of Blood Transfusion (ISBT) has investigated possibilities for the provision of standards for the protease preparations and techniques. The specification for these standards was that the performance of enzyme reference preparation in the reference technique should be of equivalent sensitivity to the ICSH/ISBT LISS spin indirect antiglobulin test using a titration series of a reference weak anti-D, and be free from false-positive reactions. The working party circulated materials for evaluation in inter-laboratory trials, followed by a laboratory workshop meeting to achieve agreement on the specification for reference materials and methods. Reference freeze-dried papain at 0.6 azoalbumin units and weak anti-D preparations (91/562) have been prepared and validated to meet these specifications. The performance of a test enzyme preparation in the technique for which it is recommended for use should be at least equal to that of the reference papain preparation, by the reference two-stage technique in terms of sensitivity, using a titration series of the reference anti-D, and freedom from false-positive reactions, using six fresh inert sera. The reference papain and weak anti-D can also be used to calibrate the level of proteolytic activity required in other procedures in blood group serology, such as new technology methods for antibody detection, and automated and microplate cell grouping procedures. These preparations and an agreed method for their use are now available from listed centres as ICSH/ISBT and Food and Drug Administration reference materials.

Blood Grouping and Crossmatching↗

Report of the First International Workshop on molecular blood group genotyping.

The use of molecular genetic technology for blood group typing is becoming routine procedure in many reference laboratories worldwide. A First International Workshop was organized on behalf of the International Society of Blood Transfusion (ISBT) and the International Council for Standardization in Haematology (ICSH). Thirty laboratories that provide a molecular diagnostic service participated in the workshop. Six samples were distributed: two represented DNA from transfusion-dependent patients for testing for multiple polymorphisms; two represented fetal DNA prepared from amniotic fluid for RhD, Rhc and K-testing; and two represented plasma from RhD-negative pregnant women for fetal RhD testing. Error rates varied from 0 to 11% for different polymorphisms. A consensus arising from discussion on the workshop results between participants at a feedback meeting and by e-mail has resulted in seven recommendations for molecular blood group genotyping. Further international workshops will take place every 2 years, with a more limited exercise being organized in the intervening years.

Blood Group Antigens↗

Evaluation of a haematological analyser (Sysmex F-800) with equine blood.

A semiautomatic electronic blood cell counter (Sysmex F-800) was evaluated with equine blood, according to the protocol of the International Committee for Standardization in Haematology (ICSH, 1984). The precision and overall reproducibility were acceptable for all the parameters studied except for the platelet count, in which a coefficient of variation of 18.8% and 21.7% was obtained for within and between batch precision and 26.76% for overall reproducibility. Carry-over for the haematocrit value and platelet count was unsatisfactory, thus the use of a blank diluent sample between different analyses was necessary. Linearity of the analyser was acceptable in the range studied. A total of 100 equine blood samples were studied with the Sysmex F-800 and the manual method. The correlations between both Methods were acceptable for all the parameters. In the storage study, the red blood cell count and the haemoglobin concentration were the parameters with longest stability (72 h) at 4 degrees C and 25 degrees C. Platelet count decreased significantly at 3 h post-extraction in those samples stored at 4 degrees C. During the evaluation period, Sysmex F-800 was easy to handle and it is well suited for routine equine blood cell analysis.

Animals↗

Erythrocyte pyruvate kinase deficiency: relations of residual enzyme activity, altered regulation of defective enzymes and concentrations of high-energy phosphates with the severity of clinical manifestation.

The defective enzymes of 54 patients with pyruvate kinase (PK) deficiency were characterized according to the recommendations of the International Committee for Standardization in Haematology (ICSH). The erythrocyte PK activity in whole blood was calculated considering the 16-fold higher activity of the reticulocyte enzyme (AR) compared to the erythrocyte enzyme (AE). The following parameters turned out to give a good correlation to the degree of haemolytic anaemia and can therefore serve as a prognostic tool: All patients with a severe course of the disease had residual erythrocyte PK activities less than 33% of the normal enzymes (percentage activity), and patients with mild haemolytic anaemia exhibited residual activity values below and above this threshold value. Studies of enzyme cooperative showed that positive cooperative or mixed cooperative phosphoenolpyruvate (PEP) binding with a predominant positive cooperative part appeared in all cases with a mild clinical course, and about one-third of the severe ones. Negative cooperativity or mixed cooperativity with predominant negative cooperative part was observed only with severe haemolytic anaemia. Furthermore, the determination of glucose-6-phosphate (G-6-P) turned out to be a good prognostic criterion, i.e. all patients with mild clinical course exhibited G-6-P-concentrations lower than 0.11 mumol/l red blood cells. In the case of patients with severe haemolytic anaemia, about 80% showed values higher than 0.11 mumol/l RBC.

2,3-Diphosphoglycerate↗

Evaluation of a hematology analyzer with canine and feline blood.

A semiautomatic electronic blood cell counter (Sysmex F-800:Toa Medical Electronics Europa Gmbh, Hamburg, Germany) was evaluated using canine and feline blood, following the International Committee for Standardization in Hematology protocol (ICSH, 1984). Precision and overall reproducibility were acceptable for all the parameters studied except for the feline platelet count, in which overlapping of erythrocyte and platelet populations prohibited determination of an accurate platelet count. Since carry-over from canine hematocrit values and platelet counts and from feline hematocrit values was unsatisfactory, the use of a blank diluent sample between different analyses was necessary. Linearity of the analyzer was acceptable in the studied range. Thirty canine and feline blood samples were analyzed using the Sysmex F-800 and a manual method. Correlations between both methods were acceptable for all the parameters, except for feline platelet count and erythrocyte indices for both species. In the storage study, red blood cell count and hemoglobin concentration were the parameters with the longest stability (72 hours at 4 degrees C and 25 degrees C) in both species. A statistically significant increase in MCV was obtained at 12 hours post-extraction in canine samples stored at 25 degrees C and at 24 hours in refrigerated samples. Feline leucocyte counts showed a downward trend at 12 hours post-extraction at both temperatures. Canine platelet count decreased significantly at 6 hours post-extraction in samples stored at 4 degrees C. During the evaluation period, Sysmex F-800 was user friendly and appeared well suited for routine canine and feline blood cell analysis.

Journal Article↗

[Neonatal screening of hemoglobinopathies and glucose-6-phosphate dehydrogenase in Catalonia. Pilot study in anonymous not related population].

BACKGROUND AND OBJECTIVE: This was a preliminary study on the prevalence of the HbS gene, associated with sickle cell disease, other hemoglobinopathies and G6PD deficiency of immigrant and non-immigrant population of Catalonia. PATIENTS AND METHOD: A total of 3,189 blood samples from the Catalan Neonatal Screening Program for Metabolic Diseases (CNSPMD) including 1,620 from immigrant population were screened for haemoglobinopathies and G6PD deficiency. For screening of hemoglobinopathies the high performance liquid chromatography (HPLC) method was used and for the screening of G6PD deficiency, we used the fluorescent spot test as described by ICSH. RESULTS: 1. Hemoglobinopathies: in 47 samples from immigrant population 2 cases of sickle cell anemia (phenotypes FS and FSC) were detected as well as 45 cases of heterozygote carriers of different pathological hemoglobins (HbS, HbC, HbD and HbE). 2. G6PD deficiency: in 29 samples, 3 cases of G6PD deficiency belonging to local (non-immigrant) population of G6PD were detected. CONCLUSIONS: The incidence of sickle cell disease in the risk population of Catalonia is 1 case out of 810 samples. This value is significantly higher than that reported for any of the metabolic diseases included in the CNSPMD. Despite it is a preliminary study, the results obtained give further support to the convenience of incorporating a neonatal screening of hemoglobinopathies, at least in the risk population, to the official programs of newborn screening. Due to its feasibility and low cost, a similar criterion might be adopted for the neonatal screening of G6PD deficiency.

Emigration and Immigration↗

Biochemical characterization of four new erythrocyte pyruvate kinase variants.

Pyruvate kinase (PK) from four patients with moderate to severe congenital non-spherocytic haemolytic anaemia was characterized by methods recommended by the ICSH. The possibility that two of the patients are true homozygotes cannot be ruled out, while the other two apparently represent double heterozygotes. All but one had levels of PK activity between 44 and 65% of normal. The variant enzymes were designed 'PK Pontos', 'PK Macedonia', 'PK Athens' and 'PK Larisa'. Multiple physicochemical as well as kinetic aberrations were detected in the above variants. Their altered kinetic behaviour is discussed in terms of the concerted transition model for allosteric enzymes and their abnormal properties are compared with other known variants, while it is also attempted to correlate them with possible mechanisms resulting in chronic haemolytic anaemia.

Adolescent↗