Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Helium”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

A helium gas probe for use in cryosurgery.

The design and testing of a prototype cryosurgical probe utilizing helium gas precooled with liquid nitrogen are described. An 8-mm-diameter probe produced an ice ball with a diameter of 28 mm after 10 min freezing using a helium gas flow rate of 42 liter/min. This indicated a surface heat transfer coefficient of 0.34 W/cm2 degrees K and temperature of -138 degrees C at the probe tip. Improved performance figures can be achieved using higher gas pressures and flow rates. A helium gas flow system schematic for use with this new type of cryoprobe is also presented. It is claimed that this system will overcome the problems of developing both multiple-tipped probes and small-diameter needle probes for use in cryoanalgesia.

Cryosurgery↗

Effects of intraamniotic helium, carbon dioxide, and water on fetal lambs.

The hysteroscopic approach to the correction of congenital anomalies in utero may be helped by the temporary introduction of clear, electrically neutral fluids (liquids or gases) into the amniotic cavity. Accordingly, the authors determined the effects of three candidate fluids (helium, carbon dioxide, and water) on the oxygenation, acid-base balance, electrolyte concentrations, and hemodynamic function of nine sheep fetuses at 120 days' gestation (full term 145 days). Each fetus was exposed, in random order, to each of the three fluids, at an intraamniotic pressure of 15 mm Hg. The authors found that helium produced no changes in any of the measurements and was well tolerated by the fetus and the mother. Carbon dioxide decreased fetal arterial pH, and increased both arterial PCO2 and PO2. Although the decrease in pH was explained entirely by the increase in PCO2, the increase in arterial PO2 may have resulted from vasodilatation of the placental circulation or vasoconstriction of the fetal circulation with a redistribution of blood flow to the placenta. Water caused mild fetal hyponatremia and hypochloremia, without significant changes in acid-base balance or oxygenation. The results suggest that both helium and water may represent viable alternatives for amniotic fluid replacement during hysteroscopic surgery.

Acid-Base Equilibrium↗

The effect of the anoxic radiosensitizing agent TAN on induction of revertants by gamma-rays and helium ions in Salmonella tester strains.

The modification effect of the anoxic radiosensitizer TAN on the mutagenesis in various Salmonella tester strains after gamma-ray and helium ion irradiation was studied. The oxygen enhancement ratios (OER) for all 3 strains on the lethal assay after gamma-irradiation are approximately equal to 2. The induction of reversions in TA98 and TA100 does not modify under anoxia. The value of OER on the mutagenic assay in TA102 equals 1.6. The OER after helium ion irradiation on the lethal and mutagenic assays was less than after gamma-irradiation. The mutagenesis in 3 strains after irradiation under anoxia is enhanced by TAN. The value of the TAN modification effect after gamma-irradiation increases from 2.1 +/- 0.2 for TA102 to 5.2 +/- 0.4 for TA100. However, the TAN influence on mutagenesis in TA100 after helium ion irradiation decreases to 3.1 +/- 0.3. We conclude that peculiarities of mutagenesis in various tester strains under anoxia with TAN can be explained by considering the nature of premutational DNA damages.

Anaerobiosis↗

Helium pressure potentiates the N-methyl-D-aspartate- and D,L-homocysteate-induced decreases of field potentials in the rat hippocampal slice preparation.

We examined the influence of helium pressure on the depression induced by various excitatory amino acids in CA1 hippocampal field potentials. The effects of quisqualate, L-glutamate, L-aspartate and kainate were not significantly affected by helium pressure, while those of N-methyl-D-aspartate and D,L-homocysteate were enhanced. These findings suggest that helium pressure specifically increased the sensitivity of the N-methyl-D-aspartate receptor type in the hippocampus. Other hypotheses are discussed.

Action Potentials↗

Substrate properties affect the mass loss rate in collodion at liquid helium temperature.

A previous measurement showed that mass loss from collodion supported by thin carbon films was linear with electron exposure at liquid helium temperature. No other organic solid had shown a linear loss of mass at any temperature. When measurements of collodion were done using titanium supports, the loss of mass proceeded exponentially with exposure at liquid helium temperature. This result suggested that the differing electrical conductivities of these substrates might be the cause of the different mass loss effects. Carbon films, which are typically used at ambient temperatures, have much lower electrical conductivity at very low temperature than titanium films. This suggested that specimen preparation materials and techniques used routinely for room temperature studies may need to be modified when microscopy is done using superconducting objective lenses. For both substrates, the rate of mass loss is slowest at liquid helium temperature.

Carbon↗

Effects of helium-oxygen mixtures on endotracheal tubes: an in vitro study.

QUESTION: To determine flow pattern and critical Reynolds numbers in endotracheal tubes submitted to different helium-oxygen mixtures under laboratory conditions. MATERIALS AND METHODS: Flow-pressure relationships were performed for seven endotracheal tubes (rectilinear position, entry length applied) with distal end open to atmosphere (predicted internal diameters: 6-9 mm). Nine helium-oxygen mixtures were tested, with FIHe varying from zero to 0.78 (increment: 10%). Nine flows were tested, with rates varying from 0.25 to 1.60 l s(-1) (increment: 0.15 l s(-1)). Gas flow resistance was calculated, and for each endotracheal tube, a Moody diagram was realised. Flow regime and critical Reynolds numbers were then determined (fully established laminar, nonestablished laminar, smooth turbulent, or rough). RESULTS: Even low concentration of helium in inspiratory mixture reduces endotracheal tubes resistance. Effect is maximal for high flows, small tube and high FIHe. Critical Reynolds numbers are inversely correlated to tube diameter. ANSWER: Under laboratory conditions, flow pattern in endotracheal tubes varies from fully established laminar to rough. Knowledge of the critical Reynolds numbers allows correct application of fluid mechanic formula when studying tube or gaseous mixture effects on respiratory mechanisms.

Adult↗

A comparison of liquid nitrogen and liquid helium as cryogens for electron cryotomography.

The principal resolution limitation in electron cryomicroscopy of frozen-hydrated biological samples is radiation damage. It has long been hoped that cooling such samples to just a few kelvins with liquid helium would slow this damage and allow statistically better-defined images to be recorded. A new "G2 Polara" microscope from FEI Company was used to image various biological samples cooled by either liquid nitrogen or liquid helium to approximately 82 or approximately 12 K, respectively, and the results were compared with particular interest in the doses (10-200 e-/A2) and resolutions (3-8 nm) typical for electron cryotomography. Simple dose series revealed a gradual loss of contrast at approximately 12K through the first several tens of e-/A2, after which small bubbles appeared. Single particle reconstructions from each image in a dose series showed no difference in the preservation of medium-resolution (3-5 nm) structural detail at the two temperatures. Tomographic reconstructions produced with total doses between 10 and 350 e-/A2 showed better results at approximately 82 K than approximately 12 K for every dose tested. Thus disappointingly, cooling with liquid helium is actually disadvantageous for cryotomography.

Cryoelectron Microscopy↗

GABAergic modulation in the substantia nigra of the striatal dopamine release and of the locomotor activity in rats exposed to helium pressure.

Helium-oxygen pressure induces in rodents an increase of both locomotor and motor activity (LMA) and of the striatal dopamine release, which could result from a decrease of GABA transmission in the substantia nigra. The effects of the GABA(A) receptor agonist muscimol and of the GABA(B) receptor agonist baclofen on the striatal dopamine release were measured using differential pulse voltammetry. Behavioural studies were performed in freely moving rats using actimetry. Whatever the drug used under helium pressure, bilateral administration in the substantia nigra pars reticulata (SNr) or in the substantia nigra pars compacta (SNc) counteracted the evoked dopamine release. However, only the baclofen reduced the LMA, while the muscimol administration in the SNr, but not in the SNc, increased it. These results indicate that different subtypes of GABA receptors would be involved in the control of the DA release and in the occurrence of LMA under helium pressure.

Air Pressure↗

Helium-oxygen mixture in respiratory distress syndrome: a double-blind study.

In a randomized, controlled trial, the lungs of infants with respiratory distress syndrome were ventilated with either a helium-oxygen mixture or a nitrogen-oxygen mixture. In the helium-oxygen group, infants required a lower inspired oxygen concentration and a shorter duration of ventilation. There were also fewer deaths and fewer cases of bronchopulmonary dysplasia in the helium-oxygen group.

Airway Resistance↗

15 years experience with helium ion radiotherapy for uveal melanoma.

PURPOSE: To review the long-term experience of helium ion therapy as a therapeutic alternative to enucleation for uveal melanoma, particularly with respect to survival, local control, and morbidity. METHODS AND MATERIALS: 347 patients with uveal melanoma were treated with helium ion RT from 1978-1992. A nonrandomized dose-searching study was undertaken, with doses progressively reduced from 80 GyE in five fractions to 48 GyE in four fractions, given in 3-15 days, mean of 7 days. RESULTS: Local control was achieved in 96% of patients, with no difference in the rate of local control being seen at 80, 70, 60, or 50 GyE in five fractions. At the lowest dose level of 48 GyE in four fractions, the local control rate fell to 87%. Fifteen of 347 patients (4%) had local regrowth in the eye requiring enucleation (12 patients), laser (1 patient) or reirradiation (2 patients). The time of appearance of local regrowth ranged from 4 months to 5 years posttreatment, with 85% occurring within 3 years. Of the 347 patients, 208 are alive as of May 1, 1997. The median follow up of all patients is 8.5 years, range 1-17 years. Kaplan-Maier (K-M) survival is 80% at 5 years, 76% at 10 years, and 72% at 15 years posttreatment. Patients with tumors not involving the ciliary body have a 15-year K-M survival of 80%. The results for patients whose tumors involved the ciliary body are poor, with a 15-year K-M survival of 43%. Seventy-five percent of patients with tumors at least 3.0 mm from the fovea and optic nerve, and initial ultrasound height less than 6.0 mm, retained vision of 20/200 or better posttreatment. Patients with tumors larger than 6 mm in thickness, or with tumors lying close to the optic nerve or fovea, have a reduced chance of retaining useful vision. The enucleation rate is 19%, 3% for local failure and 16% because of complications of the helium RT, particularly neovascular glaucoma, which occurred in 35% of patients. CONCLUSIONS: Local control and retention of the eye are excellent. Complications of therapy reduce vision and eye preservation. Twenty-four percent of patients manifested distant metastases 6 to 146 months posttreatment, mean of 43 months, median of 36 months. Late-appearing distant metastases do not appear to be caused by persistent tumor in the eye. The risk of metastases is high for patients with tumors greater than 7 mm in initial ultrasound height (37%), anterior tumors involving the ciliary body (47%), and in those with local failure (53%). Patients with tumors not involving the ciliary body and initial dimensions less than 10 mm had only an 8% chance of death from melanoma. A search for effective adjuvant therapy is needed for patients at high risk of metastases (large tumors, ciliary body involved, local regrowth in eye).

Ciliary Body↗

Helium flux from a sedimentary basin.

The tritium-3He ages of groundwaters collected from the Saijo Basin in Japan were measured. The ages vary between 11.7 and 16.3 years. The 4He flux of >3 x 10(4) atoms/cm2 s is calculated by the 4He concentrations and ages. In addition the helium flux of 8.3 x 10(5) atoms/cm2 s is calculated at the Higashi-Niigata gas field in Japan. The above two estimates are consistent with the continental helium flux reported in the literature, suggesting that helium flux on the Earth's crust is uniform.

Geologic Sediments↗

Measurement of helium isotopes in soil gas as an indicator of tritium groundwater contamination.

The focus of this study was to define the shape and extent of tritium groundwater contamination emanating from a legacy burial ground and to identify vadose zone sources of tritium using helium isotopes (3He and 4He) in soil gas. Helium isotopes were measured in soil-gas samples collected from 70 sampling points around the perimeter and downgradient of a burial ground that contains buried radioactive solid waste. The soil-gas samples were analyzed for helium isotopes using rare gas mass spectrometry. 3He/4He ratios, reported as normalized to the air ratio (RA), were used to locate the tritium groundwater plume emanating from the burial ground. The 3He (excess) suggested that the general location of the tritium source is within the burial ground. This study clearly demonstrated the efficacy of the 3He method for application to similar sites elsewhere within the DOE weapons complex.

Environment↗

Mechanical ventilation during pregnancy using a helium-oxygen mixture in a patient with respiratory failure due to status asthmaticus.

The authors present a 15-year-old with a second trimester intrauterine pregnancy who developed respiratory failure as the result of status asthmaticus and the development of the adult respiratory distress syndrome. Mechanical ventilation was provided with a combination of oxygen and helium to facilitate gas exchange and limit peak inflating pressures. The physiologic basis for helium's potential beneficial effects on gas exchange are reviewed. Previous reports concerning the use of helium during mechanical ventilation as well as the techniques of delivery are discussed.

Adolescent↗

Radon, helium and uranium survey in some thermal springs located in NW Himalayas, India: mobilization by tectonic features or by geochemical barriers?

Radon, helium and uranium measurements have been carried out in hot water springs in the Parbati and Beas valleys of Himachal Himalaya. Most of these hot springs are known as famous pilgrimage centers. The activity of dissolved radon in the liquid phase is found to vary widely, by an order of magnitude, between 10 and 750 Bq L(-1), whereas, the dissolved helium content in these thermal springs varies between 10 and 100 ppm. The uranium contents are low and vary from <0.01 to 5 microg L(-1). The measured values of radon, helium and uranium are possibly controlled by structural geology, namely the presence of pervious fault systems, and by the lithology of the leached host rocks. Redox-potential geochemical barriers cause the mobilization of uranile ions in solution (UO2+); the most plausible hypothesis is when the conditions are oxidising, confirming the importance of physico-chemical conditions up to the supergenic environment, to control the fluid geochemistry of the U-He-222Rn system. Some evidence is available from both geothermometric considerations and geochemical data which will be reported elsewhere, whereas the present study is focused on U decay series-noble gas geochemistry. The first analysis of collected 3He/4He data is consistent with a crustal signature at the studied thermal springs.

Data Collection↗

(HCl)2 and (HF)2 in small helium clusters: quantum solvation of hydrogen-bonded dimers.

We present a rigorous theoretical study of the solvation of (HCl)(2) and (HF)(2) by small ((4)He)(n) clusters, with n=1-14 and 30. Pairwise-additive potential-energy surfaces of He(n)(HX)(2) (X=Cl and F) clusters are constructed from highly accurate four-dimensional (rigid monomer) HX-HX and two-dimensional (rigid monomer) He-HX potentials and a one-dimensional He-He potential. The minimum-energy geometries of these clusters, for n=1-6 in the case of (HCl)(2) and n=1-5 for (HF)(2), correspond to the He atoms in a ring perpendicular to and bisecting the HX-HX axis. The quantum-mechanical ground-state energies and vibrationally averaged structures of He(n)(HCl)(2) (n=1-14 and 30) and He(n)(HF)(2) (n=1-10) clusters are calculated exactly using the diffusion Monte Carlo (DMC) method. In addition, the interchange-tunneling splittings of He(n)(HCl)(2) clusters with n=1-14 are determined using the fixed-node DMC approach, which was employed by us previously to calculate the tunneling splittings for He(n)(HF)(2) clusters, n=1-10 [A. Sarsa et al., Phys. Rev. Lett. 88, 123401 (2002)]. The vibrationally averaged structures of He(n)(HX)(2) clusters with n=1-6 for (HCl)(2) and n=1-5 for (HF)(2) have the helium density localized in an effectively one-dimensional ring, or doughnut, perpendicular to and at the midpoint of the HX-HX axis. The rigidity of the solvent ring varies with n and reaches its maximum for the cluster size at which the ring is filled, n=6 and n=5 for (HCl)(2) and (HF)(2), respectively. Once the equatorial ring is full, the helium density spreads along the HX-HX axis, eventually solvating the entire HX dimer. The interchange-tunneling splitting of He(n)(HCl)(2) clusters hardly varies at all over the cluster size range considered, n=1-14, and is virtually identical to that of the free HCl dimer. This absence of the solvent effect is in sharp contrast with our earlier results for He(n)(HF)(2) clusters, which show a approximately 30% reduction of the tunneling splitting for n=4. A tentative explanation for this difference is proposed. The implications of our results for the interchange-tunneling dynamics of (HCl)(2) in helium nanodroplets are discussed.

Chemistry, Physical↗

Comparative effects of 60Co gamma-rays and neon and helium ions on cycle duration and division probability of EMT 6 cells. A time-lapse cinematography study.

Exponentially growing cultures of EMT 6 cells were irradiated in vitro with neon ions, helium ions or 60Co gamma-rays. Time-lapse cinematography allowed the determination, for individual cells, of cycle duration, success of the mitotic division and the age of the cell at the moment of irradiation. Irradiation induced a significant mitotic delay increasing proportionally with the delivered dose. Using mitotic delay as an endpoint, the r.b.e. for neon ions with respect to 60Co gamma-rays was 3.3 +/- 0.2 while for helium ions it was 1.2 +/- 0.1. Mitotic delay was greatest in those cells that had progressed furthest in their cycle at the time of irradiation. No significant mitotic delay was observed in the post-irradiation generation. Division probability was significantly reduced by irradiation both in the irradiated and in the post-irradiated generation. The reduction in division probability obtained with 3 Gy of neon ions was similar to that obtained after irradiation with 6 Gy of helium ions or 60Co gamma-rays.

Cell Cycle↗

Chromosome aberrations induced in human lymphocytes by 8.7 MeV protons and 23.5 MeV helium-3 ions.

This paper describes the irradiation of thin samples of blood with 8.7 MeV protons and 23.5 MeV helium-3 ions in the track segment mode. Chromosome aberrations in human lymphocytes have been scored. The relationship between dicentric yield and dose in Gy was Y = 0.044 D + 0.058 D2 for protons and Y = 0.394 D for helium ions. These results are compared with data from other laboratories using protons and an attempt is made to reconcile differences. An unexpected observation was that the ratio of the linear coefficients for helium ions and protons was about 9 whereas the ratio of the l.e.t. values was 4.5. This disagrees with current theory which predicts that the linear coefficients should be proportional to l.e.t. Possible sources of error in our experiments are discussed but do not adequately account for the discrepancies.

Chromosome Aberrations↗

Moments of dipole oscillator-strength distribution for the helium sequence.

The moments S(mu) for -6 < or = mu < or = 2 and L(mu) for mu = 0, 1 and 2 are calculated for the helium sequence for atomic numbers Z up to 30 under a screened hydrogenic model. In this model, one describes the atom by single-particle hydrogenic wavefunctions and treats the initial and the final state as characterised by two different effective charge parameters Zi and Zf, respectively. An asymptotic expansion is made of the differential oscillator strength of the screened hydrogenic model. Assuming the value 287.6 for the coefficient of the term epsilon -7/2 for helium atom as given by Salpeter and Zaidi, the parameter Zf is determined for the helium sequence. This approach has resulted in values which are in reasonable agreement with the various moment values of other authors.

Helium↗