Multichannel flow-injection-analysis biosensor system for on-line monitoring of glucose, lactate, glutamine, glutamate and ammonia in animal cell culture.

The application of a chemiluminometric method for the on-line monitoring of a hybridoma cell culture is described. Enzyme sensors for glucose, lactate, glutamine, glutamate and ammonia, based on oxidase-catalysed reactions, were developed and connected to a flow-injection-analysis (f.i.a.) biosensor. H2O2 produced by the oxidase-catalysed enzyme reaction was detected by luminol chemiluminescence with a fibre-optic H2O2 biosensor. The system has been used to monitor animal cell cultures. A continuous hybridoma cell cultivation for the production of monoclonal antibodies is presented as an example. It was possible to monitor the bioprocess over a period of 15 days. A complete analysis of all five components could be performed within 42 min. The enzyme sensors were stable during the whole cultivation time without significant loss of activity. The computer-controlled biosensor f.i.a. works with good reliability. The precision for all five components ranged between 2.2 and 4.5%. It was possible to determine glutamine in one step using an anti-interference enzyme reactor. Endogenous glutamate was completely removed up to a level of 0.5 mM.

Ammonia↗

Determination of urinary albumin using high-performance immunoaffinity chromatography and flow injection analysis.

The detection of low levels of albumin in urine can be an important aid in the early diagnosis of kidney disease. In this study, an automated system for urine analysis was developed that could simultaneously measure both albumin and creatinine, an indicator of urine output and volume. Albumin was determined by use of a column that contained immobilized anti-albumin antibodies. An on-line flow injection analysis system was used to measure creatinine as this solute eluted nonretained from the antibody column. The total analysis time of the system was 5 min per injection. Limits of detection for albumin and creatinine in a 20 microL sample (at S/N = 2) were 3 and 5 mg/L, respectively. The response for these compounds covered the range of clinical interest. Within-run precision for both analytes was +/- 1-2% at normal urine concentrations. The results of this method showed good agreement with those obtained by reference techniques. This approach can be adapted for the detection of other urine components by changing the type of antibody column used in the system.

Albuminuria↗

Automation of pharmaceutical dissolution testing by flow injection analysis.

The different types of instruments used for monitoring pharmaceutical dissolution testing are presented. Their features and the need for automation are critically discussed. The advantages of flow injection analysis in this respect are illustrated by a variety of examples clearly showing its adaptability to the different problems posed by other automatic and non-automatic alternatives.

Autoanalysis↗

Optimal design of an enzymatic reactor for flow injection analysis.

A simulation procedure for the optimization of enzymatic reactors used in sandwich flow injection systems is evaluated. The system is modeled as a plug-flow reactor with axial dispersion. To calibrate it, dispersion coefficients can be evaluated using residence time distribution techniques; meanwhile, enzymatic kinetics must be determined for the system considered, according to the values of the substrate conversion attained. The model has been linked to an optimization routine based on the Powell algorithm. The proposed approach has been evaluated in a system performing simultaneous determinations of glucose and glycerol, considered the common carbon sources in a fermentation process.

Biotechnology↗

Flow injection analysis of serum urea using urease covalently immobilized on 2-fluoro-1-methylpyridinium salt-activated fractogel and fluorescence detection.

Serum samples were analyzed for their urea content using fluorescence flow injection analysis incorporating an immobilized urease bioreactor and a gas permeable separator. The urease was immobilized under mild and facile conditions to a hydrophilic 2-fluoro-1-methylpyridinium-activated support. The ammonia released as a result of urease-catalyzed urea hydrolysis diffused through a gas permeable membrane into a constant stream of o-phthaldehyde solution to form a highly fluorescent product with lambda ex at 340 nm and lambda em at 455 nm. Up to 25 serum samples can be analyzed per hour. The within-day coefficient of variation (CV) was 1.12% and the day-to-day CV was 1.25% for serum containing 10.50 mg urea nitrogen dl-1. The bioreactor shows excellent storage (at 4 degrees C) and operational stabilities (at 37 degrees C).

Ammonia↗

Determination of hexavalent chromium in industrial hygiene samples using ultrasonic extraction and flow injection analysis.

A simple, fast, and sensitive method was developed for the determination of hexavalent chromium (CrVI) in workplace samples. Ultrasonic extraction in alkaline solutions with 0.05 M (NH4)2SO4-0.05 M NH3 provided good extraction efficiency of CrVI from the sample and allowed the retention of CrVI on an ion-exchange resin (95%). The CrVI in the sample solution was then separated as an anion from trivalent chromium [CrIII] and other cations by elution from the anion-exchange resin with 0.5 M (NH4)2SO4 in 0.1 M NH3 (pH 8) buffer solution. The eluate was then acidified with hydrochloric acid and complexed with 1,5-diphenylcarbazide reagent prior to flow injection analysis. By analyzing samples with and without oxidation of CrIII to CrVI using CeIV, the method can measure CrVI and total Cr. For optimizing the separation and determination procedure, preliminary trials conducted with two certified reference materials (CRMs 013-050 and NIST 1633a) and three spiked samples (ammonia buffer solution, cellulose ester filters and acid washed sand) indicated that the recovery of CrVI was quantitative (> 90%) with this method. The limit of detection for FIA-UV/VIS determination of the Cr-diphenylcarbazone complex was in the sub-nanogram range (0.11 ng). The technique was also applied successfully to a workplace coal fly ash sample that was collected from a power plant and paint chips that were collected from a heating gas pipe and a university building. The principal advantages of this method are its simplicity, sensitivity, speed and potential portability for field analysis.

Air Pollutants↗

Automated determination of levodopa and carbidopa in plasma by high-performance liquid chromatography-electrochemical detection using an on-line flow injection analysis sample pretreatment unit.

An automated analytical procedure is described for the parallel determination of L-3,4-dihydroxyphenylalanine (levodopa, L-dopa, LD) and the analogous hydrazine compound carbidopa (CD) in dog plasma by ion-pair high-performance liquid chromatography with electrochemical detection (HPLC-ED). After deproteinization of the plasma samples with perchloric acid the catecholamines were extracted from the supernatant by adsorption on a small column filled with alumina. The extraction and redissolution were automatically performed in a flow injection analysis unit (FIA) coupled to the HPLC system. The performance of the whole system was tested on dog plasma samples including specimens taken after oral administration of the anti-Parkinsonism drug Duellin, which is a combination tablet of levodopa and carbidopa.

Animals↗

Determination of inorganic anions by flow injection analysis and high-performance liquid chromatography combined with photolytic-electrochemical detection.

Post-column, on-line photolytic derivatization in liquid chromatography with electrochemical detection for some inorganic anions is described. Flow injection analysis and ion-pair reversed-phase chromatography followed by photolysis and electrochemical detection were used for the determinations of anions. Several operation conditions, such as mobile phase, lamp used for the photolysis, flow-rate, and applied potential, have been optimized for the determinations. Analytical figures of merit were determined. Method validation was carried out by the analysis of single blind, spiked samples. Inherent from the advantages of electrochemical detection in liquid chromatography, the method is of high sensitivity and selectivity for anion analysis.

Anions↗

Prerequisites for the on-line control of microbial processes by flow injection analysis.

Problems associated with the use of biosensors in process control, e.g. difficulties of sterilization and sensor fouling, are shortly displayed, and possibilities to overcome them are outlined. The advantages of flow injection analysis (FIA) are demonstrated and examples for efficient sampling systems connected with this method are reviewed. Special emphasis is given to problem-orientated sample pretreatments, preventing fast inactivation of immobilized enzymes in the analysis system. Examples of problem-orientated sample pretreatment units are given. A proposal for a computer-controlled self-calibrating FIA system is given.

Bacteria↗

Oxidase enzyme immobilisation through electropolymerised films to assemble biosensors for batch and flow injection analysis.

Glucose oxidase, lactate oxidase, L-aminoacid oxidase and alcohol oxidase were immobilised on new films based on 2,6-dihydroxynaphthalene (2,6-DHN) copolymerised with 2-(4-aminophenyl)-ethylamine (AP-EA) onto the Pt electrodes. The electropolymerisation was performed by cyclic voltammetry. Different scan rates and scan potential ranges were investigated and selected according to the monomers used. These sensors were tested for hydrogen peroxide, ascorbic acid and acetaminophen by cyclic voltammetry and amperometry. The amperometric studies were carried out in batch as well as in a flow injection analysis (FIA) system. Analytical parameters such as reproducibility, interference rejection, response time, buffer, storage and operational time of the sensors have been studied. These films were also characterised by X-ray photoelectron spectroscopy (XPS). Different strategies for enzyme immobilisation were performed and discussed: enzyme entrapment in the film during the electropolymerisation and covalent attachment of the enzyme to the film via a carbodiimide (1-ethtl-3-(3-dimethylaminopropyl)carbodiimide, EDC) or glutaraldehyde. Different parameters were considered in order to optimise the immobilisation procedures. Results provide a guide to design high sensitive, stable and interference-free biosensors. In addition, studies were performed using these probes in an original FIA based on solenoidal valves. Sensor stability, life time and dynamic range were also optimised in these conditions.

Biosensing Techniques↗

Polyvinyl chloride-based membranes for flow injection analysis of quinine in beverages.

Potentiometric response characteristics were evaluated for quinine selective sensors based on a lipophilic ion-exchanger potassium tetrakis[3,5-bis(trifluoromethylphenyl)]borate (PTFB) immobilized together with plasticizing solvents in polyvinyl chloride membranes. The use of dioctyl phthalate (DOP), 2-nitrophenyl phenyl ether (NPPE), and bis(2-ethylhexyl)adipate (BEHA) plasticizers produced good quality quinine sensors that were sensitive and fast responding, and exhibited near Nernstian responses when used as batch-sensors. These membranes were further tested in a wall-jet flow-through potentiometric flow injection analysis (FIA) detector. Quinine sensors containing BEHA were the most suitable membrane, with no noticeable differences in sensitivity even after 5 h of continuous exposure to solutions. Interference by foreign species such as alkali, alkaline earth metal ions, sugars, and sodium benzoate was minimal in either the batch-mode (log selectivity coefficients <-2.60) or as FIA detector. When the FIA method was used, recoveries averaged 99.70% from mineral water samples spiked with 16.22 and 162.20 ppm quinine. Results for determination of quinine in other drinks such as carbonated (64.88 and 71.37 ppm) and bitter lemon drinks (55.15 ppm) agreed with those of the manufacturer's claimed values of <68, <81, and 51 ppm, respectively. With a sample throughput of 50 samples/h under optimized flow conditions, the method can be routinely used to monitor quinine in such samples.

Beverages↗

Flow injection analysis using continuous channel electrophoresis.

Continuous zone electrophoretic separations in narrow channels coupled to small-bore capillaries have been demonstrated and characterized previously. Presented here is the use of this new technique to monitor dynamic chemical changes occurring in a flow injection analysis system. The fundamental aspects of the data that this type of separation generates are discussed in a comparison of static and dynamic analyses. An analysis of a dynamic separation is also provided to thoroughly outline the steps necessary to deconvolute the data. Three types of dynamic analyses, which simulate realistic analytical situations, are then examined in detail. The first of these involves the addition of a mixture of four dansylated amino acids to the flow injection system to provide several different sample duration periods. The second is the staggered addition of short-duration plugs of analyte to the system. The third is the continuous addition of one analyte at different concentrations. Quantitative information generated by these experiments includes the simultaneous determination of the time of analyte contact and its duration of contact with the sampling capillary, identification of analytes based on electrophoretic mobilities, and concentration changes with time. For the addition of a 1.52 mM solution of N epsilon-dansyl-L-lysine, the sample duration and time of analyte contact with the capillary was determined with an error of < 4%. Concentration changes in the FIA system of dansyl-L-arginine over the range of 0.38-3.04 mM are also demonstrated with transitional edges on the time scale of 3-4 s. Qualitatively, the appearance of analyte bands can reveal impurities and fronting or tailing effects as seen in conventional capillary electrophoretic separations. The results demonstrate the ability of the technique to successfully probe dynamic environments.

Arginine↗

Flow injection analysis of lactose using covalently immobilized beta-galactosidase, mutarotase, and glucose oxidase/peroxidase on a 2-fluoro-1-methylpyridinium salt-activated Fractogel support.

Milk samples were analyzed for their lactose content using flow injection analysis and incorporating immobilized beta-galactosidase or beta-galactosidase/mutarotase and glucose oxidase/peroxidase bioreactors. These enzymes were immobilized, under mild conditions, on to a 2-fluoro-1-methylpyridinium salt-activated Fractogel support. The use of a phosphate buffer (0.15 M) was found to facilitate the rapid mutarotation of alpha-D-glucose and hence could obviate the need for the more expensive mutarotase. The chromogenic agents of choice for monitoring the reaction were 3-methyl-2-benzothiazolinone hydrazone and 3-dimethylaminobenzoic acid. Linearity was observed over the concentration range 16-160 micrograms/ml using lactose standards (r = 0.996). Between 30 and 40 milk samples/h can be analyzed. Comparisons are made with existing HPLC and alkaline methylamine methods for a range of milk matrices. The FIA method consistently gives the lowest standard deviations and coefficient of variation for the various milk matrices analyzed.

Animals↗

High-throughput flow-injection analysis of glucose and glutamate in food and biological samples by using enzyme/polyion complex-bilayer membrane-based electrodes as the detectors.

The concentration of glucose was determined by a combination of flow injection analysis (FIA) with amperometric enzyme sensor detection. The enzyme sensor was prepared by immobilizing glucose oxidase on an electrode coated with a polyion complex layer consisting of poly-L-lysine and poly(4-styrenesulfonate). The inner, polyion complex layer was useful for preventing electrochemical interferents (e.g., L-ascorbic acid, uric acid and acetaminophen) from reaching the electrode surface, which was effective for reducing the interferential responses upon the injections of biological and food samples. The sensor-based system could be used for the determination of glucose from 10 microM to 3 mM with the sampling rate of 180 h-1, and was stable for more than 2 months. An FIA system for determining L-glutamic acid (3 microM-0.5 mM) was also prepared by using an enzyme electrode based on a glutamate oxidase/polyion complex-bilayer as the detector.

Biosensing Techniques↗

Drug substance manufacture process control: application of flow injection analysis and HPLC for monitoring an enantiospecific synthesis.

Effective process control can only be achieved through an understanding of the operating issues of the reaction. The development and use of effective and rugged analytical methods is necessary to monitor these parameters. The intent of this paper is to present some key analytical issues encountered in the synthesis of MK-0679, an LTD4 antagonist. In a key step of the compound's synthesis, a prochiral diester intermediate undergoes an enantioselective enzymatic hydrolysis (in the presence of Triton X-100) leading to the (S)-ester acid. Subsequent processing transforms the ester acid into the final product. The residual amount of the detergent in the final product, the rapid determination of the enzymatic activity and the optical purity of the final product emerged as key issues in the control of the reaction. As a solution, two techniques were utilized and are presented: flow injection analysis and HPLC.

Chromatography, High Pressure Liquid↗

Immunoaffinity layering of enzymes. Stabilization and use in flow injection analysis of glucose and hydrogen peroxide.

A general procedure for the high yield immobilization of enzymes with the help of specific anti-enzyme antibodies is described. Polyclonal antibodies were raised against Aspergillus niger glucose oxidase and horseradish peroxidase in rabbits and the gamma globulin (IgG) fraction from the immune sera isolated by ammonium sulphate fractionation followed by ion-exchange chromatography. Immobilization of glucose oxidase and horseradish peroxidase was achieved by initially binding the enzymes to a Sepharose matrix coupled with IgG isolated from anti-(glucose oxidase) and anti-(horseradish peroxidase) sera, respectively. This was followed by alternate incubation with the IgG and the enzyme to assemble layers of enzyme and antibody on the support. The immunoaffinity-layered preparations obtained thus were highly active and, after six binding cycles, the amount of enzyme immobilized could be raised about 25 times over that bound initially. It was also possible to assemble layers of glucose oxidase using unfractionated antiserum in place of the IgG. The bioaffinity-layered preparations of glucose oxidase and horseradish peroxidase exhibited good enzyme activities and improved resistance to heat-induced inactivation. The sensitivity of a flow injection analysis system for measuring glucose and hydrogen peroxide could be remarkably improved using immunoaffinity-layered glucose oxidase and horseradish peroxidase. For the detection of glucose, a Clark-type oxygen electrode, constructed as a small flow-through cell integrated with a cartridge bearing immunoaffinity-layered glucose oxidase was employed. The hydrogen peroxide concentration was analysed spectrophotometrically using a flow-through cell and the layered horseradish peroxidase packed into a cartridge. The immunoaffinity-layered enzymes could be conveniently solubilized at acid pH and fresh enzyme loaded onto the support. Immunoaffinity-layered glucose oxidase was successfully used for the on-line monitoring of the glucose concentration during the cultivation of Streptomyces cerevisiae.

Animals↗

Monitoring of chemical and enzymatic hydrolysis of water-soluble proteins using flow-injection analysis with fluorescence detection and an aqueous eluant containing 2-p-toluidinylnaphthalene-6-sulfonate as the fluorescent probe.

The exposed hydrophobicity of proteins, which is due to the hydrophobic regions located on their surfaces, enhances the fluorescence intensity of the probe 2-p-toluidinylnaphthalene-6-sulfonate (2,6-TNS) by the formation of a complex. During the hydrolysis of a protein, the average exposed hydrophobicity of the substrate continuously changes with incubation time, and these changes are immediately reflected by a corresponding change in the fluorescence intensity of the 2,6-TNS/substrate complex. Therefore, 2,6-TNS seems to be a good probe to monitor the course of the depolymerization processes of proteins. In this work, bovine serum albumin and alpha-casein have been hydrolyzed both chemically and enzymatically, and the course of the reactions is monitored by using flow-injection analysis (FIA) with fluorescence detection and a buffered aqueous eluant containing 2,6-TNS as the fluorescent probe. Results indicate that the time evolution of the fluorescence intensity of the 2,6-TNS/substrate complex can be correlated with the initial concentration of the parent protein, in mass per unit volume, the hydrolytic activity added, and the time evolution of the mean chain length of the substrate. In addition, because the time elapsed between injection of the sample into the FIA system and measurement of the corresponding fluorescence intensity is only a few seconds, this methodology could be a useful tool for on-line monitoring of processes for the production of protein hydrolysates.

Biosensing Techniques↗

A simple flow injection analysis for studies of drug-protein binding interactions in serum.

Studies of drug-protein binding constants (ka) and of the degree of binding (%B) in biological fluids have been carried out by means of flow injection analysis (FIA). The association constants found for clinically relevant concentrations agree with the literature data. The degree of binding found for discoumarol, phenytoin and sulfisoxazole is also in agreement with the literature whereas that of warfarin is slightly lower.

Blood Proteins↗