Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cathode Ray Tube”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Invariance of odor strength with sniff vigor: an olfactory analogue to size constancy.

Previous evidence has shown that detection threshold in humans and olfactory neural discharge rate in animal preparations both depend on flow rate of odorous vapor. But no data have been reported that show the effects of flow rate in humans on perceived odor strength at suprathreshold intensities. Subjects learned to inspire at two flow rates, one twice as great as the other, by adjusting (on a cathode ray tube) the transduced trace of a sniff-produced pressure change to match either of two target contours. They then made magnitude estimations of odor strength, while producing either weak or strong sniffs, for odorants presented over a wide range of concentrations via a specially designed sniff-bottle system. The odorant, diluted in diethyl phthalate, was n-butanol in two experiments and n-amyl acetate in two others. Subject-controlled flow rate had no effect on odor strength for either odorant. There was an apparent contradiction between these data and those on neural discharge rate that may, however, be resolved by adopting an odor constancy model: When sniff intensity varies during the olfactory exploration of an odor source, information about the rate at which odorant molecules are established at the receptor site is combined with information about sniff vigor so that the resulting percept is of invariant odor strength.

Acetates↗

Auditory and temporal factors in the modality effect.

Subjects in five experiments read nine-digit memory lists from a cathode ray tube for immediate recall. Reading aloud always produced a localized and reliable advantage for the last item, compared to reading silently. Two experiments on whispered and mouthed lists, with or without simultaneous broadband noise, falsified expectations derived from the theory of precategorical acoustic storage. Three additional experiments showed no enhancement of recency in the silent conditions when the digits were drawn or spelled gradually on the screen, a result that is inconsistent with the changing-state hypothesis. The classic auditory-visual modality effect is large and reliable, but still poorly understood.

Humans↗

Changes in visual function with normal ageing, cataract and intraocular lenses.

We have been able to separate the neural and optical components of vision with contrast sensitivity tests employing laser interferometry and direct viewing of a cathode ray tube display. In normal ageing, neural function declined markedly while optical function remained essentially unchanged. On the other hand, even the mildest degree of cataract was shown to degrade optical function to the extent that it exceeded the age-related neural deterioration. The satisfactory optical performance of the monofocal implant lens has been confirmed, though the diffractive bifocal implant lens was shown to have optical limitations. A major cause of these was shown, by simulation experiments, to be the dilution of the contrast of the in-focus image by the superimposed defocused image, particularly under conditions of reduced retinal sensitivity as would be present in the elderly.

Adolescent↗

Visual field interpretation with a personal computer based neural network.

The Computer Assisted Touch Screen (CATS) and Computer Assisted Moving Eye Campimeter (CAMEC) are personal computer (PC)-based video-campimeters which employ multiple and single static stimuli on a cathode ray tube respectively. Clinical studies show that CATS and CAMEC provide comparable results to more expensive conventional visual field test devices. A neural network has been designed to classify visual field data from PC-based video-campimeters to facilitate diagnostic interpretation of visual field test results by non-experts. A three-layer back propagation network was designed, with 110 units in the input layer (each unit corresponding to a test point on the visual field test grid), a hidden layer of 40 processing units, and an output layer of 27 units (each one corresponding to a particular type of visual field pattern). The network was trained by a training set of 540 simulated visual field test result patterns, including normal, glaucomatous and neuro-ophthalmic defects, for up to 20,000 cycles. The classification accuracy of the network was initially measured with a previously unseen test set of 135 simulated fields and further tested with a genuine test result set of 100 neurological and 200 glaucomatous fields. A classification accuracy of 91-97% with simulated field results and 65-100% with genuine field results were achieved. This suggests that neural networks incorporated into PC-based video-campimeters may enable correct interpretation of results in non-specialist clinics or in the community.

Diagnosis, Computer-Assisted↗

Chromatic-contrast threshold impairment in diabetes.

A prospective study was carried out to investigate acquired colour-vision deficits in diabetics using an automated, computer-controlled, cathode-ray-tube based test of chromatic contrast. Chromatic-contrast thresholds estimates were measured along both a red/ green (constant S-cone) confusion axis and a tritan (constant M/L-cone) confusion axis for 305 eyes of 305 diabetics. The diabetic data were partitioned into groups based on a clinical categorisation of retinopathy. The diabetic data were compared with both age-matched and 'lens-equated' control data obtained from a bank of 347 normal subjects. Further analysis of differences between diabetic-status groups was performed. Associations between chromatic contrast threshold estimates and age, duration of disease, and severity of both macular oedema and ischaemia were investigated. The diabetic group was found to have significantly reduced chromatic-contrast threshold estimates when compared with normal controls, even in the absence of retinopathy. This reduction in chromatic contrast was predominantly tritanopic in nature. Interestingly, no reduction in red/green chromatic-contrast threshold estimate was found in diabetics without retinopathy. The tritan deficit seen in diabetics without retinopathy was strongly correlated with duration of disease, but when adjustments were made to account for the effects of duration-dependent lens yellowing, the tritan deficit was no longer apparent. A correlation between both the severity of macular oedema and severity of ischaemia with chromatic-contrast loss was established. Acquired reductions in both red/green and tritan chromatic-contrast threshold estimates seen in diabetics are strongly correlated with the severity of retinopathy. The results provide evidence that the specific tritan deficits seen in diabetics can be explained by the effects of lens yellowing rather than by selective damage of the blue cone system as has been hypothesised by other groups. The results provide support for the potential use of automated CRT-based tests of colour vision in diabetic retinopathy screening protocols.

Adolescent↗

Effect of video display on the grading of diabetic retinopathy.

PURPOSE: Digital images are increasingly being used in ophthalmology. These may be viewed either on thin-film transistor (TFT) or on cathode-ray tube (CRT) displays. However, there is little data showing which is superior. In this study, we compared the performance of CRT and TFT displays for grading of both compressed and uncompressed images of diabetic retinopathy. METHODS: A total of 49 35 mm transparencies of diabetic retinopathy were scanned and compressed. The images comprised 17 with no retinopathy, eight with background, five with preproliferative, and 19 with proliferative retinopathy. Four levels of compression were used: 0, 70, 80, and 90%. A total of 196 randomised images were presented to two masked graders using both TFT and CRT displays under uniform lighting conditions, 2 months apart. The grade of retinopathy was assessed. Statistical analysis of grading accuracy was performed using receiver operator characteristic curves of sensitivity and specificity and the Stuart-Maxwell test for paired, nonparametric data. RESULTS: Both displays showed high sensitivity and specificity for the detection of any retinopathy. For the specific grade of retinopathy, the CRT performed slightly better with a sensitivity of 0.80 for uncompressed images, compared with 0.75 using the TFT. Compression reduced these sensitivities to 0.73 on the CRT and 0.63 on the TFT. Grading of uncompressed images magnified to four times their original size was more accurate on the TFT. CONCLUSIONS: Grading on both displays met sensitivity and specificity criteria proposed by Diabetes UK (formerly British Diabetic Association) for screening of diabetic retinopathy. The CRT generally performed slightly better than the TFT in relation to the detection of the specific grade of retinopathy.

Computer Peripherals↗

Scanning resolution and the detection of approximal caries.

OBJECTIVE: To determine a proper scanning resolution for digitizing bitewing radiographs in the detection of approximal caries. METHODS: Fifty-two premolars and 48 molars were mounted in blocks and imaged on conventional film (Ektaspeed Plus, Eastman-Kodak, Rochester, NY USA) simulating a bitewing projection. The 15 bitewing radiographs were then scanned with a flatbed scanner at three resolutions 150, 300 and 600 d.p.i. The digitized images were displayed in random order on a high-resolution cathode ray tube monitor. Ten observers assessed the caries status of 200 approximal surfaces. They scored lesion presence on a 5-point confidence scale and depth on a 3-point scale. The observer's scores were compared with the results from a histological examination. Data were analysed using analysis of variance, by calculating signed observer error, absolute observer error and observer confidence. RESULTS: Lesion depth had a significant effect on confidence of lesion recognition. The main effect of resolution and the interaction between resolution and lesion depth were significant. Pair-wise comparison showed a significant difference between resolutions in case of sound surfaces and surfaces with dentinal lesions for absolute error. The confidence increased as the resolution increased but no significant difference was found between 300 and 600 d.p.i. The best score for depth estimation was obtained at the 300 d.p.i. scanning resolution. CONCLUSIONS: When bitewing radiographs are scanned with a flatbed scanner, a resolution of 300 d.p.i. seems the best choice. At this resolution the digital file size is manageable without significant loss of the information necessary for caries diagnosis.

Absorptiometry, Photon↗

A visual method for analysing bucco-lingual position of artificial posterior teeth. Part 1: use of the ridge crest.

We have developed a visual analysis method to examine the spatial relationship between the edentulous ridges and the bucco-lingual position of the artificial posterior teeth in complete denture fabrication. In this system, a non-contact type shape measurement system is used. We applied this system to the plaster models and the wax dentures of an edentulous patient. Using the measurement data on the upper and lower plaster models, we reconstructed their shape three-dimensionally and determined the points regarded as the ridge crests and the inter-alveolar crest lines in the frontal sections. To generate the upper and lower ridge crest lines which consisted of the points of the ridge crests, interpolation by B-spline curves was applied. Furthermore, the loft surfaces that we regarded as the consecutive inter-alveolar crest lines, were generated between the upper and lower ridge crest lines. The surface models of the plaster models and artificial teeth were displayed on the cathode-ray tube display unit, and the ridge crest lines and the consecutive inter-alveolar crest lines were superimposed on the surface models. This method could be utilized to visualize and examine the bucco-lingual position of the artificial posterior teeth in reference to the inter-alveolar crest lines.

Computer Graphics↗

Study on photo-pattern sensitivity in patients with electronic screen game-induced seizures (ESGS): effects of spatial resolution, brightness, and pattern movement.

PURPOSE: With the ever-increasing popularity of computers, electronic screen game-induced seizure (ESGS) is beginning to pose a serious social problem. To elucidate the pathophysiology of ESGS, with the ultimate goal of prevention, we have been studying photo-pattern sensitivity in detail with a pattern-stimulation test using a CRT (cathode ray tube) display. This method is referred to as the "CRT-pattern test." METHODS: We studied 17 patients brought to our department for evaluation of ESGS. EEG responses were recorded during exposure to various patterns consisting of three elements: spatial resolution, brightness perception, and pattern-movement recognition displayed on a CRT monitor. Photo-paroxysmal response (PPR) frequencies were compiled for each stimulation. RESULTS: PPR was induced by the CRT-pattern test in nine of the 17 cases. In four cases, PPR induction was obtained only after introducing CRT-pattern tests in addition to standard intermittent photic stimulation (IPS). The rate of PPR induction differed according to the type of pattern, spatial frequency, and pattern-reversal frequency. However, neither the clarity of the edges of a pattern nor changes in the brightness of a pattern element had any effect on the rate of PPR induction. With the exception of a few subjects, the stimulation caused by pattern movement was not effective in eliciting PPR. Six cases in whom spatial resolution was involved showed occipital dominance in PPR provocation, and three in whom brightness perception and pattern movement recognition was involved showed frontal dominance. CONCLUSIONS: The CRT-pattern test is useful for identifying patients with photosensitivity among patients considered to have incidental or nonphotosensitive seizures unresponsive to standard IPS. Patients with ESGS caused by photosensitivity can be divided into two groups: those with occipital dominance for PPR provocation, in whom spatial resolution is involved; and another group with frontal dominance, in whom brightness perception and pattern-movement recognition (or possibly perception of colors) are involved.

Adolescent↗

A new face-mounted display system: pilot trial of clinical application in therapeutic endoscopy.

BACKGROUND AND STUDY AIMS: Since fiber endoscopes evolved into video endoscopes, there has been no remarkable progression in the optical system for endoscopy. The current optical system provided by fixed cathode-ray tube (CRT) display is a monitor-oriented system. In this study, we evaluate the practical usefulness of the face-mounted display (FMD), which provides us with an operator-oriented optical system. PATIENTS AND METHODS: The FMD device, weighing 110 g, is designed for consumer video home use, consisting of two active matrix liquid crystal color panels with 180,000-pixel resolution. With the picture-in-picture capability, FMD provided us with image-navigated endoscopic procedure. Fourteen patients were enrolled in this study; seven patients for endoscopic mucosal resection, two for insertion of an esophageal metallic stent, three for clipping for the bleeding and two for dilatation of anastomotic strictures. RESULTS: The FMD device allowed us to use an ultra large screen as if there has been a 62-inch screen 2 m ahead. During endoscopy, we could concentrate more on the procedures. There were no complications attributable to the use of the device. CONCLUSION: We are convinced of a new evolution in the optical system for therapeutic endoscopy with the FMD device.

Endoscopes, Gastrointestinal↗

Effects of phosphor persistence on perception and the control of eye movements.

When a rapid eye movement (saccade) is made across material displayed on cathode ray tube monitors with short-persistence phosphors, various perceptual phenomena occur. The phenomena do not occur when the monitor has a long-persistence phosphor. These phenomena were observed for certain spatial arrays, their possible physiological basis noted, and their effect on the control of eye movements examined. When the display consisted simply of two dots, and a saccade was made from one to the other, a transient ghost image was seen just beyond the destination target. When the display consisted of vertical lines, tilting and displacement of the lines occurred. The phenomena were more intrusive for the latter display and there was a significant increase in the number of corrective saccades. These results are interpreted in terms of the effects of fluctuating illumination (and hence phosphor persistence) on saccadic suppression.

Adult↗

No evidence for prolonged latency of saccadic eye movements due to intermittent light of a CRT computer screen.

Despite previous studies it remains unclear, whether saccadic eye movements across computer screens may be adversely affected by the intermittency of light of cathode ray tubes (CRT). We measured the latency of simple saccades to peripheral targets presented on a CRT-screen, operated at refresh rates of 50, 100 and 150 Hz, compared with a special fluorescent lamp display (FLD). Our results suggest that the intermittent light of CRT screens does not prolong the latency of saccades not even relative to a control condition of unmodulated steady light at the FLD. Further, there was no evidence for any individual effect in possibly susceptible subjects, e.g. at high critical flicker frequencies (CFF).

Adult↗

Accommodation, convergence, pupil diameter and eye blinks at a CRT display flickering near fusion limit.

This study investigates possible effects of temporally modulated light stimulation near critical fusion frequency (CFF) when subjects observe a cathode ray tube (CRT) operated at different refresh rates. Various visual functions were measured in a series of tests of 2.5 min duration. In experiment 1, at a repetition rate of 50 Hz mean pupil size was 0.055 mm smaller than at 300 Hz. The precision of convergence and accommodation in binocular vision was not affected. In experiment 2, 300 Hz was compared with the lowest frequency that did not produce visible flicker for each subject. At the lower rate (55 to 90 Hz), mean accommodation in monocular vision was 0.06 D weaker, median eye blink duration was 6% shorter, and mean eye blink interval was 15% longer. Individual differences and possible fatigue effects of intermittent light at visual display units are discussed.

Accommodation, Ocular↗

Analysis of ocular surface area for comfortable VDT workstation layout.

This paper proposes a comfortable visual display terminal (VDT) workstation layout based on an analysis of ocular surface area (OSA). A large OSA induces eye irritation and eye fatigue because the eye surface is highly sensitive to various stimuli. The authors considered that OSA must be one of the useful indices of visual ergonomics and applied it to evaluate VDT workstation layout. Each subject was asked to perform a word processing task using four different VDT workstation layouts. It was found that the main factor affecting OSA was not cathode ray tube (CRT) height itself but the distance between the CRT and keyboard. Thus the following workstation layout is recommended to realize comfortable VDT operation: (1) the desk height should be adjusted to the user's height; and (2) the CRT display should be set closer to the keyboard to provide a smaller OSA.

Adult↗

Motor Performance of Stutterers and Nonstutterers on Timing and Force Control Tasks.

Recently it has been suggested that speech and manual timing tasks share a common central process (Franz, Zelaznik, & Smith, 1992): Because stuttering is thought to be related to deficits in motoric processes such as timing, stutterers (n = 15) were compared with a set of age-, education-, and sex-matched nonstutterers on timing and isometric force-production tasks. In the timing tasks, subjects flexed and extended the right index finger at the metacarpophalangeal joint at cycle durations of 600, 500, 400, 300, and 200 ms. In the force-production tasks, subjects generated isometric forces to match target force levels displayed on a cathode-ray tube (CRT) screen. There were five levels of force, ranging from.11 to 7.85 newtons. Overall, there were no differences in timing and force-production performance between stutterers and nonstutterers. These results are similar to those obtained recently by Hulstijn, Summers, van Lieshout, and Peters (1992). We suggest that stuttering is not characterized by a general deficit in rhythmic timing. Instead, the motor deficit associated with stuttering should be viewed as speech specific.

Journal Article↗

Effect of CT digital image compression on detection of coronary artery calcification.

PURPOSE: To test the effect of digital compression of CT images on the detection of small linear or spotted high attenuation lesions such as coronary artery calcification (CAC). MATERIAL AND METHODS: Fifty cases with and 50 without CAC were randomly selected from a population that had undergone spiral CT of the thorax for screening lung cancer. CT image data were compressed using JPEG (Joint Photographic Experts Group) or wavelet algorithms at ratios of 10:1, 20:1 or 40:1. Five radiologists reviewed the uncompressed and compressed images on a cathode-ray-tube. Observer performance was evaluated with receiver operating characteristic analysis. RESULTS: CT images compressed at a ratio as high as 20:1 were acceptable for primary diagnosis of CAC. There was no significant difference in the detection accuracy for CAC between JPEG and wavelet algorithms at the compression ratios up to 20:1. CT images were more vulnerable to image blurring on the wavelet compression at relatively lower ratios, and "blocking" artifacts occurred on the JPEG compression at relatively higher ratios. CONCLUSION: JPEG and wavelet algorithms allow compression of CT images without compromising their diagnostic value at ratios up to 20:1 in detecting small linear or spotted high attenuation lesions such as CAC, and there was no difference between the two algorithms in diagnostic accuracy.

Adult↗

Luminance of the surround and visual fatigue of VDT operators.

Luminance distribution in the visual field is considered as one of causal factors with a significant influence on visual fatigue, especially for intensive and extended Video Display Terminal (VDT) work. The aim of the study was to define visual fatigue of VDT operators for different values of surrounding luminance. Experiments were carried out in laboratory conditions under 3 lighting conditions. Only 1 lighting parameter--the luminance of the wall behind the display (surrounding luminance)--changed. Visual fatigue was measured both by a subjective evaluation of different visual complaints (asthenopic symptoms) and by objective measurements of changes in the following visual functions: accommodation, convergence, habitual horizontal phoria, critical fusional frequency (CFF), and visual acuity. The same experiments were done for CRT (Cathode Ray Tube) and LCD TFT (Liquid Crystal Display with Thin Film Transistor) screens. The results of the study have shown that there was no significant influence of the value of surrounding luminance on the asthenopic symptoms for either type of screen. A general tendency towards bigger visual complaints for LCD TFT than for CRT participants was found. An objective evaluation of visual fatigue demonstrated a tendency towards bigger changes in visual functions with an increase of surrounding luminance for both screens. Statistical analysis of the results has shown that surrounding luminance influences significantly the reduction of the accommodation amplitude (significance level <.05).

Adolescent↗