Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CATHODE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Ultrastructural localization of the circulating cathodic antigen in the digestive tract of various life-cycle stages of Schistosoma mansoni.

In the present study the ultrastructural localization of the schistosome-derived circulating cathodic antigen (CCA) within the digestive tract of various life-cycle stages of the blood fluke Schistosoma mansoni has been determined. Use was made of CCA-specific monoclonal antibodies in a two-step gold-labeling procedure. The following results were obtained: In cercariae gold label was found in the cytoplasm and in the luminal surface coat of the gut epithelium. The oesophagus of this life-cycle stage of the parasite showed minimal CCA reactivity, as gold label was limited to the luminal surface coat, locating proximally to the gut. In 3 1/2-week-old worms and in adult male and female worms CCA was demonstrable in the Golgi apparatus, in cytoplasmic vesicles and in the luminal surface coat; in the caudal quarter of the gut of adult worms CCA was also present in lysosome-like bodies. The oesophagus of these worm preparations did not show any CCA reactivity. In miracidia CCA was not present.

Animals↗

Immunofluorescent localization of Schistosoma mansoni circulating cathodic antigen in tissues of infected mice using monoclonal antibody.

In the present study the kinetics of the uptake and deposition of the major circulating cathodic antigen (CCA) of Schistosoma mansoni in liver, spleen, and kidney of S. mansoni infected Swiss mice was investigated in relation to the duration of infection and infection dose (50, 100, 200 cercariae). The presence of antigen was studied with a direct immunofluorescence reaction on frozen sections of the mouse organs, using a fluorescein isothiocyanate (FITC)-labelled mouse IgM monoclonal antibody recognizing a repeating epitope of CCA. CCA was demonstrable from 2 weeks post infection (p.i.) onwards in Kupffer cells in the liver, from 3-4 weeks p.i. onwards in macrophages in the marginal zones in the spleen and from 8 weeks p.i. onwards in kidney glomeruli. The immunofluorescence reactions on CCA in kidney glomeruli, however, remained relatively weak.

Animals↗

Detection of antibodies against circulating cathodic antigen of Schistosoma mansoni using the enzyme-linked immunosorbent assay.

The applicability of a Schistosoma mansoni polysaccharide antigen, circulating cathodic antigen (CCA), for the detection of antibodies in S. mansoni infection was tested in the enzyme-linked immunosorbent assay (ELISA). Antibodies against this secretory antigen were detected in hamster infections after three weeks, while in infected humans anti-CCA antibodies could be demonstrated eight weeks after infection. Antibodies could be demonstrated both in recent and chronic infections in man, but more false-negative results were observed in chronic infections. The antibody response was composed of both IgM and IgG antibodies.

Adult↗

Serum levels of circulating anodic antigen and circulating cathodic antigen detected in mice infected with Schistosoma japonicum or S. mansoni.

Serum concentrations of circulating anodic antigen (CAA) and circulating cathodic antigen (CCA) were studied in mice infected with either Schistosoma japonicum or S. mansoni cercariae. Sera from uninfected mice were negative for both antigens. CAA was detectable in the S. japonicum-infected mice as early as at 2 weeks post-infection (p.i.), and levels were higher in these animals than in the S. mansoni-infected group during the full study period. At the moment of perfusion, 10 weeks p.i., a median of 9 and 29 worms, respectively, were recovered from the S. japonicum- and S. mansoni-infected mice, and the median CAA levels were 326 and 27 ng/ml, respectively. In contrast, CCA levels were much lower in the S. japonicum-infected group (27 ng/ml) as compared with the S. mansoni-infected mice (282 ng/ml). These results suggest an important difference between S. japonicum and S. mansoni infections in CAA and CCA production and/or clearance and indicate a significant role for CAA in the diagnosis of human schistosomiasis japonicum.

Animals↗

10 kHz microsecond pulsed X-ray generator utilising a hot-cathode triode with variable durations for biomedical radiography.

A 10 kHz pulsed X-ray generator utilising a hot-cathode triode in conjunction with a new type of grid control device for controlling X-ray duration is described. The energy-storage condenser was charged up to 70 kV by a power supply, and the electric charges in the condenser were discharged to the X-ray tube repetitively by the grid control device. The maximum values of the grid voltage (negative value), the tube voltage, and the tube current were -1.5 kV, 70 kV, and 0.4 A, respectively. The duration of the flash X-ray pulse was primarily determined by the time constant of the grid control device and the cut-off voltage of thermoelectrons. The X-ray duration was controlled within a region of less than 1 ms; the X-ray intensity with a pulse width of 0.27 ms, a charged voltage of 70 kV, and a peak tube current of 0.4 A was 0.92 microC kg-1 at 0.5 m per pulse. The maximum repetition rate was about 10 kHz, and the size of the focal spot was about 3.5 x 3.5 mm.

Animals↗

Performance tests and quality control of cathode ray tube displays.

Spatial resolution, noise, characteristic curve, and absolute luminance are the essential parameters that describe physical image quality of a display. This paper presents simple procedures for assessing the performance of a cathode ray tube (CRT) in terms of these parameters as well as easy set up techniques. The procedures can be used in the environment where the CRT is used. The procedures are based on a digital representation of the Society of Motion Pictures and Television Engineers pattern plus a few simple other digital patterns. Additionally, measurement techniques are discussed for estimating brightness uniformity, veiling glare, and distortion. Apart from the absolute luminance, all performance features can be assessed with an uncalibrated photodetector and the eyes of a human observer. The measurement techniques especially enable the user to perform comparisons of different display systems.

Data Display↗

Active matrix liquid crystal displays for clinical imaging: comparison with cathode ray tube displays.

Fifteen large-area, flat-panel displays used for clinical image review were evaluated for image quality and compared with 30 comparably sized cathode ray tube (CRT) monitors. Measurements were of image display patterns by Video Electronic Standards Association (VESA) and a commercial product. Field measurements were made of: maximum and minimum luminance, ambient lighting, characteristic curve (gamma), point shape and size, high-contrast resolution, uniformity, and distortion. Assessments were made of pixel defects, latent image patterns, ghosting artifacts, and viewing angle luminance. Also, a questionnaire was generated for users of the flat-panel and CRT units. Seventeen respondents indicated no preference for either flat panel or CRT. Results show these flat panels to have higher luminance (mean, 177.7 cd/m2); larger number of just noticeable differences (JNDs; n = 555), higher gamma, comparable uniformity, and warm-up time. CRTs had less angle viewing dependence and far fewer artifacts (ghosting and latent images). Our questionnaire showed active matrix liquid crystal displays (AMLCD) to be fully acceptable for clinical image viewing. Furthermore, the statistical results show that further testing for new AMLCDs of this type is unwarranted.

Computer Terminals↗

Diagnostic usefulness of chest computed radiography--film versus cathode-ray tube images.

Seventy-one plain chest images obtained by computed radiography (CR) with an imaging plate were interpreted on film and two kinds of cathode-ray tube (CRT) monitors installed separately at two facilities (1,024 x 1,536 pixels, 8 bits, and 1,024 x 1,280 pixels, 10 bits) by 20 radiologists and four chest internists. The clinical categories of these 71 cases included pulmonary nodules and interstitial abnormalities. Image reading sessions were held over a total of 4 days, ie, 2 days and then another 2 days, 3 weeks later. Twenty-four observers formed four groups with six members each. Two groups read either films or CRT images at one of the two facilities. In the second experiment, 26 of 71 images were compressed at 10:1, 19 of 71 were compressed at 20:1, and 26 were not compressed. Analyses of the areas under the receiver-operating characteristic curves showed no significant differences in detection of pulmonary abnormalities between film and CRT. In detecting interstitial pulmonary abnormalities, film was more sensitive than CRT monitor. There were no significant differences in observers' performances between the two different kinds of CRT workstation. Subjective evaluation of image quality showed that images irreversibly compressed to the ratios of 10:1 and 20:1 were inferior to original images. Although further considerations are needed with regard to spatial resolution requirements, image processing, and image compression, the utilization of CR CRT image as a substitute for CR film image will be possible.

Data Display↗

Calibration of medium-resolution monochrome cathode ray tube displays for the purpose of board examinations.

This report discusses calibration and set-up procedures for medium-resolution monochrome cathode ray tubes (CRTs) taken in preparation of the oral portion of the board examination of the American Board of Radiology (ABR). The board examinations took place in more than 100 rooms of a hotel. There was one display-station (a computer and the associated CRT display) in each of the hotel rooms used for the examinations. The examinations covered the radiologic specialties cardiopulmonary, musculoskeletal, gastrointestinal, vascular, pediatric, and genitourinary. The software used for set-up and calibration was the VeriLUM 4.0 package from Image Smiths in Germantown, MD. The set-up included setting minimum luminance and maximum luminance, as well as positioning of the CRT in each examination room with respect to reflections of roomlights. The calibration for the grey scale rendition was done meeting the Digital Imaging and communication in Medicine (DICOM) 14 Standard Display Function. We describe these procedures, and present the calibration data in. tables and graphs, listing initial values of minimum luminance, maximum luminance, and grey scale rendition (DICOM 14 standard display function). Changes of these parameters over the duration of the examination were observed and recorded on 11 monitors in a particular room. These changes strongly suggest that all calibrated CRTs be monitored over the duration of the examination. In addition, other CRT performance data affecting image quality such as spatial resolution should be included in set-up and image quality-control procedures.

Calibration↗

Copper-mercury film electrode for cathodic stripping voltammetric determination of Se(IV).

The copper-mercury film electrode has been suggested for the determination of Se(IV) in a wide range of concentration from 1x10(-9) to 1x10(-6) mol L(-1)by square-wave cathodic stripping voltammetry. Insufficient reproducibility and sensitivity of the mercury film electrode have been overcome by using copper(II) ions during the plating procedure. Copper(II) has been found to be reduced and form a reproducible copper-mercury film on a glassy carbon electrode surface. The plating potential and time, the concentration of copper(II) and the concentration of the supporting electrolyte have been optimised. Microscopy has been used for a study of the morphology of the copper-mercury film. It has been found that it is the same as for the mercury one. The preconcentration step consists in electrodeposition of copper selenide on the copper-mercury film. The relative standard deviation is 4.3% for 1x10(-6) mol L(-1) of Se(IV). The limit of detection is 8x10(-10) mol L(-1) for 5 min of accumulation.

Journal Article↗

Cathodic adsorptive stripping square-wave voltammetric determination of nifedipine drug in bulk, pharmaceutical formulation and human serum.

Nifedipine is a calcium-channel antagonist drug used in the management of angina pectoris and hypertension through inhibition of calcium influx. A fully validated sensitive cathodic adsorptive stripping square-wave voltammetry procedure was optimized for the determination of the drug at trace levels. The procedure was based on the reduction of the nitrophenyl group after the interfacial accumulation of the drug onto a hanging mercury drop electrode in Britton-Robinson buffer of pH 11.0. The optimal conditions of the procedure were found to be: accumulation potential=-0.9 V vs. Ag/AgCl/KCl(s)), accumulation time=30 s, scan increment=10 mV, pulse amplitude=50 mV and frequency=120 Hz. Under these conditions, a well-defined peak was obtained; its peak current showed a linear dependence on drug concentration in the range of 2x10(-9)-2x10(-7) mol L(-1) bulk nifedipine. The mean recoveries based on eight replicate measurements for 1x10(-8) and 5x10(-8) mol L(-1) bulk nifedipine solutions were 98.46+/-0.86% and 98.23+/-0.92%, respectively. A detection limit of 3.42x10(-10) mol L(-1) bulk nifedipine was achieved. The procedure was successfully applied for assay of the drug in tablets and spiked human serum with mean recoveries of 101.95+/-1.42% and 98.70+/-0.63%, respectively. The limit of detection of the drug in spiked human serum was found to be 3.90x10(-10) mol L(-1).

Calcium Channel Blockers↗

Square-wave adsorptive cathodic stripping voltammetric determination of anti-inflammatory indomethacin drug in tablets and human serum at a mercury electrode.

Indomethacin is a non-steroidal anti-inflammatory drug possessing anti-pyretic and analgesic properties. A fully validated square-wave adsorptive cathodic stripping voltammetric procedure is described for determination of indomethacin. The procedure was based on the reduction of the C=O double bond of the drug molecule in Britton-Robinson buffer (pH 4) after its preconcentration onto the mercury electrode surface. The optimized conditions of the procedure were: frequency 120 Hz, scan increment 10 mV, pulse amplitude 50 mV, preconcentration potential -0.9 V (vs. Ag/AgCl/KCl(s)) and preconcentration time 90 s. The proposed procedure was successfully applied for determination of the drug in tablets and human serum with good recoveries. The limits of detection in bulk form and human serum were 6.7 x 10(-10) mol L(-1) and 8.1 x 10(-10) mol L(-1), respectively.

Adsorption↗

An optimization procedure for determination of metallothionein by square wave cathodic stripping voltammetry: application to marine worms.

Electrochemical determination of metallothionein (MT) is widely used for environmental studies. This article describes the development and optimization of the procedure for the quantification of metallothionein by square wave cathodic stripping voltammetry. The determination is based on the complexation of cisplatin and MT and the subsequent reduction of the complexes at the electrode. In order to achieve the highest possible sensitivity and resolution of the peak, an optimization of the experimental parameters has been carried out using experimental design methodology (response surface). Seven chemical and physical parameters, namely, pH, cisplatin concentration, buffer concentration, deposition potential, square wave frequency, amplitude of pulse, and step potential, have been optimized to give 9.0, 5.9 microM, 0.65 M, -0.2 mV, 229 Hz, 46 mV, and 2 mV, respectively. Method characterization has been performed, leading to a detection limit of 0.1 microg L(-1). Quantification of MT in polychaetes and comparison with the modified Brdicka procedure were also carried out.

Animals↗

Total protein determinations by particle beam/hollow cathode optical emission spectroscopy (PB/HC-OES) system III: investigation of carrier salts for enhanced particle transport.

Particle beam hollow cathode optical emission spectroscopy (PB/HC-OES) is evaluated as a generic tool for total protein determinations by monitoring the carbon atomic emission (C (I) 193.0 nm) resultant from dissociated analyte species. Previous studies demonstrated the capability of the PB/HC-OES system for total protein determinations with limits of detection for bovine serum albumin (BSA) samples being at the single-nanogram level for 200 microl injections. Non-linear behavior across the concentration range in the calibration curve was observed due to the poor transport of small particles (owing to low analyte concentrations) through the PB interface. The potential use of non-volatile salts as carrier agents is investigated in the determination of protein samples by PB/HC-OES. A range of chloride salts (different cations), potassium salts (different anions), and an organic modifier (ammonium acetate) is investigated here for possible use as carriers upon addition as sample injection matrices for protein samples. The analyte response curves of BSA samples with KCl added as the sample injection matrix show higher sensitivity, better linearity (R2) and subsequently lower detection limits in comparison to those obtained with water, HCl, KNO3 or ammonium acetate as carrier matrices.

Animals↗

Optical emission spectroscopy in reactive hollow cathode arc discharge plasmas - Local distribution of active species during the deposition of hard carbon films.

A low pressure arc plasma discharge from a hollow LaB(6)-cathode with up to 100 A discharge current is used to create plasmas of high density. Typical values for the electron density and temperature in PETRA ( Plasma Engineering and Technology Research Assembly) are n(e)=10(12)-10(13) cm(-3) and T(e)=5-20 eV. The ionization ratio is typically 1-10%. Optical emission spectroscopy has been applied to investigate the processes within the plasma which lead to the deposition of thin carbon films. In these experiments hydrogenated carbon films (a-C:H) have been deposited on Si-substrates by introducing hydrocarbon gases (CH(4), C(2)H(2)) into He- and Ar-plasmas. Space resolved optical emission spectroscopy using an in-situ translation mechanism of the optical fibre has been performed to measure the local concentrations of CH-radicals, carbon ions and of the excitation of He-neutrals. In addition the hydrogen liberated by the dissociation of the hydrocarbon molecules has been measured. The dissociation of the hydrocarbon molecules takes place as a localized process in the vicinity of the reactive gas inlet.

Journal Article↗

The use of a secondary cathode to analyse solid non-conducting samples with direct current glow discharge mass spectrometry: potential and restrictions.

A direct current glow discharge mass spectrometer has been used to analyse solid non-conducting samples: glass, polycarbonate, marble, aluminium oxide and Teflon. This is made possible by the use of a so-called secondary cathode. The methodology of this concept is investigated and analytical figures of merit are presented.

Journal Article↗

Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography.

The aim of this study was to evaluate feasibility of reporting brain CT examinations on liquid crystal display (LCD) flat-screen monitors vs state-of-the-art cathode-ray-tube (CRT) monitors. Ninety-five brain CT examinations of 95 patients were displayed on Picture archiving and communications system (PACS) workstations equipped either with a dedicated medical imaging LCD colour monitor or on a high-resolution CRT which is used for routine reporting of CT, MRI and digital radiography images in our institution. Fifty cases were negative and 45 cases were positive for early brain infarction (EBI), the latter being defined by a combination of one or more signs: dense artery; hypodensity of brain parenchyma; and local brain swelling verified by control scans. Ten radiologists had to rate presence or absence of EBI on a five-point scale. Ratings were evaluated by CORROC2 ROC software and areas under the ROC curve (A(z)) were computed. Significance of differences between the two viewing conditions were evaluated with Wilcoxon test. Mean A(z) of the ten observers was 0.7901 with LCD vs 0.7695 with CRT which did not show statistical significance (p=0.2030). In the setting investigated, reporting of CT studies from high-performance LCD monitors seems feasible without significant detriment to diagnostic performance.

Acute Disease↗

Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

The purpose of the study was to compare the detection performance of a cathode ray tube (CRT) monitor versus a liquid crystal display (LCD) monitor for simulated subtle pulmonary lesions. Ten templates containing simulated lung lesions were superimposed on an anthropomorphic chest phantom. Posteroanterior radiographs were obtained using flat panel technology and were displayed on a CRT and an LCD monitor. Image processing and reading conditions were equivalent for both softcopy displays. Five observers assessed lesion detectability using receiver-operating characteristic (ROC) methodology. A multivariate test (Pillai trace) was used to test the significance of differences (P<0.05). The multivariate test revealed significantly different detection rates for the lesion types, but no significant difference between the two display modes. Detection performance for both monitors was higher for nodules and micro-nodules and lower for lines and patchy opacities. Analysis of lesion subgroups according to their location in lucent/obscured lung areas was also not statistically significant. Under ideal reading conditions, CRT and LCD displays perform equivalently for the detection of simulated subtle pulmonary lesions.

Data Display↗