Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bioartificial Organs”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Current concepts in tissue engineering technique for repair of cartilage defect.

Hunter's observation in 1743 that cartilage "once destroyed, is not repaired," has not essentially changed for 250 years. At present, there is no well-established procedure for the repair of cartilage defect with articular cartilage, which has the same biochemical and biomechanical properties as the surrounding normal intact cartilage. In 1994, transplantation of human autologous chondrocytes in suspension, as reported by Brittberg et al., provided a potential procedure for articular cartilage repair. We have improved their procedure and developed a new technique which creates new cartilage-like tissue by cultivating autologous chondrocytes embedded in Atelocollagen gel for 3 weeks before transplantation. These improvements maintained the chondrocyte phenotype, evenly distributed chondrocytes throughout the osteochondral defects, and decreased the risk of leakage of grafted chondrocytes into the defects. Good clinical results suggest that this technique should be a promising procedure for repairing articular cartilage defect.

Adolescent↗

Evaluation of water and electrolyte transport of tubular epithelial cells under osmotic and hydraulic pressure for development of bioartificial tubules.

Our aim was to develop bioartificial tubules using tubular epithelial cells and artificial membranes and evaluate the function of water and electrolyte transport by various tubular epithelial cells. The cells were cultivated onto extracellular matrix (ProNectin F) coating polycarbonate membrane. Water transport from the apical to the basolateral site of cells was examined using a modified Ussing chamber module. Water transport under colloidal osmotic pressure on the apical site and hydraulic pressure on the basolateral site were higher in JTC-12, LLC-PK1 cells than in MDCK cells. Water transport under osmotic plus hydraulic pressure was highest in LLC-PK1 cells. We made bioartificial tubules using LLC-PK1 cells and polysulfone hollow fiber cartridges. Water and Na ion transport function was high, and BUN and creatinine passage was recognized in these bioartificial tubules. BUN and creatinine concentrations of reabsorption fluid in these bioartificial tubules were significantly lower than those concentrations of control media and of noncell attached polysulfone hollow fiber cartridges. Though LLC-PK1 cells were more preferable cells for the use of bioartificial tubules in terms of water and electrolyte transport, the passage of BUN and creatinine was not appropriate for clinical use. To select more preferable cells for bioartificial tubules which transport water and electrolytes and do not induce passage of uremic toxins is necessary.

Animals↗

Experimental evaluation of the V-point heparin-bonding system applied to a dense-membrane artificial lung during 24-hour extracorporeal circulation in beagles.

Heparin was covalently bonded to a hollow-fiber dense-membrane artificial lung and circuit using a silane coupling agent and polyethyleneimine as a spacer. This study investigated whether the novel artificial lung could sustain prolonged extracorporeal lung assist (ECLA) by venoarterial bypass in beagles using minimal anticoagulants. We maintained ECLA for 24 h in 3 groups of minimal systemic heparinization, heparinization with the new anticoagulant nafamostat mesilate, and without any systemic anticoagulant. The results were assessed from the functional performance of the artificial lung and by macroscopic and microscopic examination after the experiments. Artificial lung function, hemodynamics, hemogram, and platelet aggregation activity were well maintained in all groups. There was no plasma leakage from the artificial lung. Although several clots were observed in stagnant areas of the artificial lungs and circuits, there was no clot formation inside the artificial lung in any group. This highly biocompatible, heparin-bonded dense-membrane artificial lung performed well and safely during prolonged ECLA with blood clotting times less than 120 s.

Animals↗

Tissue engineering of small diameter vascular grafts.

Tissue engineering, using either polymer or biological based scaffolds, represents the newest approach to overcoming limitations of small diameter prosthetic vascular grafts. Their disadvantages include thromboembolism and thrombosis, anticoagulant related haemorrhage, compliance mismatch, neointimal hyperplasia, as well as aneurysm formation. This current review represents an overview about previous and contemporary studies in the field of artificial vascular conduits development regarding arterial and venous autografts, allografts, xenografts, alloplastic prostheses, and tissue engineering.

Animals↗

Seeding of human vascular cells onto small diameter polyurethane vascular grafts.

INTRODUCTION: Thrombogenicity of small diameter vascular prostheses might be reduced by complete coverage of the luminal surface with vascular cells. We investigated cell seeding on polyurethane vascular prostheses (PUVP). METHODS: 45 PUVP were divided into three groups of n = 15 each: Group A (diameter 20 mm, gamma-sterilized), Group B (diameter 4 mm, gamma-sterilized), and Group C (diameter 4 mm, ethylene oxid [Eto]-sterilized). Human smooth muscle cells (SMC), fibroblasts (FB), and endothelial cells (EC) were isolated from saphenous vein segments and expanded in culture. PUVPs were pre-seeded with a mixed culture of FBs and SMCs (mean 7.7 +/- 2.3 x 10(6) cells) followed by EC seeding (mean 4.4 +/- 0.9 x 10(6) cells). Seven days after cell seeding, PUVPs were perfused under a pulsatile flow. Flow definitions were as follows: adaption phase: low flow, resulting pressure: 60/30 mm Hg; high flow: resulting pressure: 160/50 mm Hg, lasting for 4 hours in all groups. Three subgroups were defined out of each group, differing in the perfusion strategy: high flow immediately, adaption phase of 15 minutes followed by high flow, and adaption phase of 30 minutes followed by high flow. Specimens were taken after each seeding procedure, prior to and after perfusion, and then examined using a scanning electron microscope (SEM) and immunohistochemical staining procedures. RESULTS: Pre-seeding with the mixed culture revealed a better initial adhesion in Groups A and B compared to group C (76% vs. 41%). In Groups A and B, EC seeding (adhesion 72%) resulted in a confluent EC layer. Immunohistochemical stainings were positive for collagen IV, laminin, CD31, and factor VIII, but negative for eNOS. In Group C, only isolated cells were found after each seeding procedure, which rounded up and vanished during the next days. When perfused with high-flow immediately, Group A and B prostheses revealed small defects (< 10% of the surface) of all cell layers. After perfusion with an adaption phase of 15 minutes only few defects were found within the EC layer with an intact basement membrane. An adaption phase of 30 minutes resulted in a confluent cell layer without significant cell defects. After perfusion, the endothelial cells also stained positive for eNOS. CONCLUSION: Seeding of a mixed culture consisting of FBs and SMC resulted in an excellent EC adhesion and resistance to shear stress. Cell attachment was better on gamma-sterilized PUVPs compared to Eto-sterilization. The cells obviously maintained their ability to adapt to shear stress.

Adaptation, Physiological↗

Bioartificial nerve graft for bridging extended nerve defects in rat sciatic nerve based on resorbable guiding filaments.

A long defect (15 mm) in rat sciatic nerve was repaired with a bioartificial nerve graft composed of a silicone tube and seven synthetic filaments of five types (polyamide, catgut, polydioxanone, and two types of polyglactin, normal and quickly-absorbed) inserted longitudinally into the tube. In all cases in which filaments were used a regenerating bridge was obtained in the tube after three months in contrast to empty silicone tubes, in which no structure was observed. There was a 6%-46% recovery of isometric muscle contractility of the anterior tibial and gastrocnemius muscles with positive pinch reflex test in most cases. Myelinated axons were seen in the regenerating tissue between the filaments but not directly in contact with them, and there were varying numbers of macrophages close to the filaments. Silicone tubes with filaments, regardless of type of filament, induced nerve tissue to regenerate and resulted in functional recovery through a 15 mm nerve gap not achieved with empty tubes. Nerve promoting factors may be applied to the filaments and the model is a valuable tool for further development of artificial nerve grafts.

Animals↗

Generation of a bioartificial fibromuscular tissue with autoregenerative capacities for surgical reconstruction.

INTRODUCTION: Anecdotal clinical reports denote first tissue engineering applications entering medical practice. Currently it is still unknown, if these new types of implants will tolerate the specific needs in cancer patients undergoing postoperative chemo- and radiotherapy. METHODS: We implemented a radiotherapy protocol (cumulative dosis 40 Gy) on generated human bioartificial fibromuscular tissues in vitro. We monitored tissue vitality during radiotherapy and tissue recovery (8 weeks follow up period) applying histological methods. RESULTS: The biopsy procedure and seeding techniques yielded a viable 3 dimensional bioartificial human tissue. Radiation resulted in immediate devitalization without destroying tissue integrity. The bioartificial tissue recovered entirely in vitro within 6 weeks. CONCLUSION: Bioartificial human implants appear applicable for surgical reconstruction in oncologic patients potentially facing postoperative radiotherapy.

Animals↗

Transcellular water transport and stability of expression in aquaporin 1-transfected LLC-PK1 cells in the development of a portable bioartificial renal tubule device.

We investigated a portable bioartificial renal tubule device (BRTD) consisting of renal tubule cells and hollow fibers, to improve the quality of life of patients. It is necessary for a BRTD system to be compact. A compact portable BRTB requires transfection of an appropriate water channel or electrical pump genes in tubular epithelial cells, which should be based on physiological similarities to human kidney function. LLC-PK(1) cells, into which rat kidney aquaporin 1 (AQP1) cDNA was stably transfected, were evaluated for water transport ability. The expression and localization of water AQP1 were examined by Western blotting, RT-PCR, and immunofluorescence. To measure transcellular water permeation, a simple method was applied, using phenol red as a cell-impermeant marker of concentration. In contrast to wild-type LLC-PK(1) cells, rat AQP1-transfected cells had high transcellular osmotic water permeability. The expression of rat AQP1 mRNA (ratio of AQP1 to beta-actin mRNA) and protein bands (a 28-kDa band and a broad, 35- to 45-kDa band) was confirmed to be stably maintained until a population doubling level of 24. In AQP1-transfected LLCPK(1) cells, the protein was localized mainly to the basolateral side, but also the apical side, of the plasma membrane. Wild-type LLC-PK(1) cells were not stained at the plasma membrane. It is possible that enough AQP1-transfected tubule epithelial cells were supplied for a bioartificial renal tubule device.

Animals↗

Characterization of murine autologous salivary gland graft cells: a model for use with an artificial salivary gland.

The purpose of this study was to examine the growth and key functional abilities of primary cultures of salivary epithelial cells toward developing an artificial salivary gland. Cultures of epithelial cells originating from submandibular glands of BALB/c mice were established. Parenchymal cells were isolated by a Percoll gradient technique and thereafter seeded on irradiated NIH 3T3 fibroblasts serving as a feeder layer. The isolated cells were termed autologous salivary gland epithelial (ASGE) cells and could be cultivated for at least five passages (time limit of experiments). ASGE cells presented the typical organizational behavior of epithelial cells and electron microscopy, as well as immunostaining for cytokeratins, confirmed their epithelial origin. Furthermore, measurements of transepithelial resistance and water permeability indicated the ability of the ASGE cells to form a functional epithelial barrier. This study suggests that primary salivary epithelial cells can be obtained that exhibit critical characteristics needed for use with an artificial secretory device.

Animals↗

Perfusion bioreactor for small diameter tissue-engineered arteries.

A scaleable perfusion bioreactor has been developed for tissue engineering of small diameter arterial constructs. This modular bioreactor allows for dynamic sequential seeding of smooth muscle and endothelial cells, biomechanical stimulation of cells during culture, and monitoring of tissue growth and maturation. Bovine aortic smooth muscle and endothelial cells were seeded onto porous tubular poly(glycolic acid) nonwoven scaffolds and cultured in the bioreactor under pulsatile flow conditions for up to 25 days. Cell proliferation was more than 3-fold after 4 days, smooth muscle cells expressed differentiated phenotype after 16 days, and collagen and elastin were distributed throughout the construct after 25 days of culture. In bioreactor experiments in which the construct lumen was seeded with endothelial cells by perfusion after 13 days of smooth muscle cell culture, endothelial cell seeding efficiency was 100%, and a confluent monolayer was observed in the lumen within 48 h. These data demonstrate that this perfusion bioreactor supports sequential seeding of constructs with smooth muscle and endothelial cells. Dynamic culture under pulsatile flow leads to cellular expression of differentiated function and extracellular matrix deposition toward the development of tissue-engineered arterial constructs.

Animals↗

Towards retrievable vascularized bioartificial pancreas: induction and long-lasting stability of polymeric mesh implant vascularized with the help of acidic and basic fibroblast growth factors and hydrogel coating.

We seek to improve existing methodologies for allogenic grafting of pancreatic islets. The lack of success of encapsulated transplanted islets inside the peritoneal cavity is presently attributed to poor vascularization of the implant. A thick, fibrotic capsule often surrounds the graft, limiting survival. We have tested the hypothesis that neovascularization of the graft material can be induced by the addition of proper angiogenic factors embedded within a polymeric coat. Biocompatible and nonresorbable meshes coated with hydrophilic polymers were implanted in rats and harvested after 1-, 6-, and 12-week intervals. The implant response was assessed by histological observations on the degree of vascularity, fibrosis, and inflammation. Macrostructural geometry of meshes was conducive to tissue ingrowth into the interstitial space between the mesh filaments. Hydrogel coating with incorporated acidic or basic FGF in an electrostatic complex with polyelectrolytes and/or with heparin provided a sustained slow release of the angiogenic growth factor. Anti-factor VIII and anti-collagen type IV antibodies and a GSL I-B4 lectin were used to measure the extent of vascularization. Vigorous and persistent vascularization radiated several hundred microns from the implant. The level of vascularization should provide a sufficient diffusion of nutrients and oxygen to implanted islets. Based on our observations, stable vascularization may require a sustained angiogenic signal to allow for the development of a permanent implant structure.

Animals↗

Composite articular cartilage engineered on a chondrocyte-seeded aliphatic polyurethane sponge.

To circumvent the reconstructive disadvantages inherent in resorbable polyglycolic acid (PGA)/polylactic acid (PLA) used in cartilage engineering, a nonresorbable, and nonreactive polyurethane sponge (Tecoflex sponge, TS) was studied as both a cell delivery device and as an internal support scaffolding. The in vitro viability and proliferation of porcine articular chondrocytes (PACs) in TS, and the in vivo generation of new articular cartilage and long-term resorption, were examined. The initial cell attachment rate was 40%, and cell density increased more than 5-fold after 12 days of culture in vitro. PAC-loaded TS blocks were implanted into nude mice, became opalescent, and resembled native cartilage at weeks 12 and 24 postimplantation. The mass and volume of newly formed cartilage were not significantly different at week 24 from samples harvested at week 6 or week 12. Safranin O-fast green staining revealed that the specimens from cell-loaded TS groups at week 12 and week 24 consisted of mature cartilage. Collagen typing revealed that type II collagen was present in all groups of tissue-engineered cartilage. In conclusion, the implantation of PAC-TS resulted in composite tissue-engineered articular cartilage with TS as an internal support. Long-term observation (24 weeks) of mass and volume showed no evidence of resorption.

Animals↗

Human mesenchymal progenitor cell-based tissue engineering of a single-unit osteochondral construct.

A desirable strategy for articular cartilage repair is to surgically replace the damaged area with an in vitro-engineered osteochondral plug. We report here the development of a novel osteochondral construct using human trabecular bone-derived mesenchymal progenitor cells and a biodegradable poly-D,L-lactic acid scaffold. The cartilage layer was fabricated by press-coating a chondrifying high-density cell pellet onto the scaffold, which was then loaded with cells previously initiated to undergo osteogenesis. The composite was then cultured in a cocktail medium formulated to maintain both chondrogenesis and osteogenesis. Macroscopically, the construct consisted of a cartilage-like layer adherent to, and overlying, a dense bone-like component. RT-PCR, immunohistochemistry, and histology revealed hyaline-like cartilage and bone with an interface resembling the native osteochondral junction. All parameters, including mechanical properties, improved with increased culture time. The single-cell source nature of the construct, which minimizes handling while maximizing biocompatibility, suggests applicability for articular cartilage repair.

Absorbable Implants↗

Survival of Apligraf in acute human wounds.

Apligraf consists of bovine collagen dermis seeded with allogeneic male fibroblasts and keratinocytes. It is been shown to promote healing, but the length of persistence and pathological features have not been characterized previously in acute wounds. Forty-eight deep dermal wounds were created and Apligraf, a split-skin graft (SSG), or a dressing was applied. Biopsies of wounds were taken for immunohistochemical analysis and polymerase chain reaction was performed to detect the Y chromosome from Apligraf cells in 14 female wounds. Male allogeneic DNA was detected in wounds for the first 4 weeks. All subsequent time points were negative apart from one biopsy at 6 weeks. The wounds took 4-9 weeks to heal, with the Apligraf exhibiting no features of engraftment. This was in contrast to the rapid healing seen in the SSG control group. Histology revealed a more intense cellular infiltrate, but less vascularization below Apligraf compared with controls. Evidence of an epidermal-mesenchymal interaction was observed. This is the first article to elucidate the survival of Apligraf allogeneic cells in acute wounds in immunocompetent human subjects for up to 6 weeks and demonstrates that in the management of acute surgical wounds, Apligraf has a role only as a temporary biological dressing.

Bioartificial Organs↗

Characterization of the cellular origin of a tissue-engineered human phalanx model by in situ hybridization.

Tissue-engineered models of human phalanges have previously been fabricated from a combination of bovine periosteum, cartilage, tendon, and biodegradable polyglycolic acid and poly-L-lactic acid scaffolds. Resulting constructs implanted in athymic mice for more than 40 weeks developed new bone, cartilage, and tendon and became vascularized, but cell types comprising the constructs were unidentified. The origin of cells in middle phalanx models implanted for 20 weeks in nude mice has been studied by in situ hybridization analyzing species-specific gene expression. Oligonucleotide probes homologous to species-specific gene sequences of bovine type II and X collagen, aggrecan, bone sialoprotein, biglycan, and osteopontin, and mouse decorin were labeled with (35)S and hybridized to respective serial sections of bovine tissue, mouse tissue, and phalanx constructs. In situ hybridization showed positive message and tissue-specific localization for all bovine-specific probes examined within cartilaginous and midshaft portions of constructs and negative message for the mouse-specific decorin probe. These data show that osteoblasts and chondrocytes comprising constructs are derived exclusively from their original bovine sources over 20 weeks of implantation. Defining the cellular origin of the models lends insight into their biological, chemical, and physical nature and their growth and development. Maintenance of their initial genotype is crucial for future application of the models in augmenting impaired human phalanges and related tissues.

Animals↗

Novel pulse duplicating bioreactor system for tissue-engineered vascular construct.

Cell culture in a biomimetic environment is known to improve the mechanical endurance of tissue-engineered cardiovascular components. Our goal was to generate a bioreactor that can reproduce a wide range of pulsatile flows with a completely physiological pressure profile. The morphology and biochemical properties of tissue-engineered products were also studied to test the usefulness of this novel bioreactor. The combination of an outflow valve, compliance chamber, and resistant clamps together with a balloon pumping system was able to successfully reproduce both physiological systolic and diastolic pressures. The compliance chamber was especially effective in transforming the original peaky pressure waveform into a physiological pressure profile. The tissues, cultured under a physiological pressure waveform with pulsatile flow, presented widely distributed cells in close contact with each other. They also showed significantly higher cell numbers, total protein content, and proteoglycan-glycosaminoglycan content than cultured tissues under a peaky pressure wave or under static conditions. This new bioreactor system is suitable for evaluating a favorable environment for tissue-engineered cardiovascular components.

Animals↗