Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Quantitative analysis of acetates in cigarette tobacco using solid-phase microextraction and gas chromatography-mass spectrometry.

A method incorporating solid-phase microextraction (SPME) and gas chromatography-mass spectrometry for the headspace analysis of selected volatile organic compounds present in cigarette tobacco is developed and evaluated. Quantitative information on methyl, ethyl, n-propyl, isopropyl, isopropenyl, vinyl, and butyl acetates present in 29 different flavor variants (full, light, and ultra-light) of the top ten selling brands in the United States is presented. The concentrations of the various acetate analytes range from the low nanaogram to microgram levels per cigarette. Clear differences are observed in the concentrations of various acetates when comparing the levels in brands from different manufacturers. The SPME technique provides a method that allows high sample throughput, requires little sample preparation, and yields useful analytical information. High precision is obtained on multiple measurements of cigarettes from an individual pack, but lower precision levels are observed in general when comparing results obtained on the analysis of cigarettes from different packs of the same brand. The higher pack-to-pack variations may be due in part to product aging with a proportionate amount of evaporative loss of the relatively volatile acetates.

Acetates↗

Determination of phenylalanine in human serum by isotope dilution liquid chromatography/tandem mass spectrometry.

Isotope dilution liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) has been developed as a candidate reference method to determine the level of phenylalanine in human serum. The advantages of this method include a simple sample preparation without derivatization, selective detection of analytes, and the use of an isotopic analogue as an internal standard. Phenylalanine and its isotopic analogue, phenylalanine-ring-(13)C(6), were monitored at the transitions m/z 166.2/120.2 and 172.2/126.2 in the multiple-reaction monitoring (MRM) mode, respectively. The expanded uncertainty of the measurement result of phenylalanine in the serum was approximately 1.2% within a 95% confidence level. A standard reference material, with a certified value of phenylalanine, was analyzed in order to verify this method. The result obtained by the ID-LC/MS/MS method differed somewhat from the certified value, but agreed well with the gravimetric value. The measurement result of phenylalanine in serum by ID-LC/MS/MS was compared with the results from the commercial HPLC method, which was carried out in clinics. The results from the commercial HPLC method showed inconsistent results with each other. The busted results from the commercial HPLC method suggest that it should be possible to trace the results of the commercial fields to well-characterized reference materials or methods.

Carbon Isotopes↗

[Application of microwave dissolution and inductively coupled plasma-MS spectrometry for determination of ultra-trace level of lanthanides in human rib].

A new method for the determination of ultra-trace level of lanthanides such as La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm Yb and Lu in human rib is explored. Closed-vessel microwave digestion with concentrated HNO3 is used for the sample preparation and the digested analyte is directly analyzed by ICP-MS. The method is sensitive and accurate and, is efficient for the determination of the fourteen lanthanides listed above. Detection limit for various elements ranges from 0.0007 microgram/L to 0.005 microgram/L. Calibration plots exhibit good linearity with high linear correlation coefficient r > or = 0.997. Recoveries of spiked samples ranges from 93.7% to 115.4%. Precision is < 3% RSD. Rhodium is used as the internal standard to compensate the signal suppression caused by the sample matrix. Isobaric overlap of polyatomic ions caused by matrix oxide/hydroxide of barium is corrected by interference correction factor. Two standard reference materials, namely "Human Hair GBW07601" and "Wheat Flour GBW08503" are used for quality control of the analyzed samples.

Adult↗

Determination of ochratoxin A in foods: state-of-the-art and analytical challenges.

Ochratoxin A (OTA) can occur in a large variety of commodities (cereals, beans, groundnuts, spices, dried fruits, coffee, beer, wine) and, because of a carry-over effect, in milk, pig blood, liver, and kidney, and poultry meat from animals fed with contaminated feed. Because of the persistence of OTA in the food chain, exposure to the compound is a potential human health hazard. This has prompted adoption of regulatory limits in several countries which, in turn, implies the development of suitable validated and official analytical methods and rapid screening tests for cost-effective food control on a large scale. Liquid chromatography with fluorescence detection (LC-FLD), coupled with immunoaffinity column (IAC) clean-up, is the most widely employed analytical technique. LC coupled with electrospray-ionization mass spectrometry (MS) has detection limits comparable with those of LC-FLD and the selectivity of IAC can be achieved by tandem (MS-MS) or sequential (MS(n)) detection. Synthetic counterparts to natural antibodies in the form of molecularly imprinted polymers seem a promising alternative to IAC for sample preparation. New analytical approaches to rapid, low-cost screening methods, for example those based on biosensors and dip-stick-like kits, are a direction in which innovation can be expected. Analytical methods for evaluation of the occurrence of OTA in foods, human exposure, and risk assessment are critically reviewed.

Animals↗

HPLC with simultaneous UV and reductive electrochemical detection at the hanging mercury drop electrode: a highly sensitive and selective tool for the determination of benzodiazepines in forensic samples.

A versatile, sensitive, and selective high-performance liquid chromatographic (HPLC) procedure for the determination of common benzodiazepines and some of their most frequently occurring metabolites in forensic samples was developed and optimized with respect to effective and rapid sample preparation and high selectivity of the analytical assay. The optimized method includes liquid-liquid extraction of the drugs with chloroform followed by isocratic reversed-phase chromatography on a LiChrospher-100 RP-8ec column (150 x 4.6-mm i.d.) with a mobile phase consisting of 0.03 mol/L acetate buffer (pH 4.6)/acetonitrile (55:45, v/v). The use of dual-mode detection made up of UV-detection (250 nm) in series with reductive electrochemical detection (-1.4 V vs. Ag/AgCl) at the hanging mercury drop electrode permits the detection and quantitation of benzodiazepines even in degraded samples with higher selectivities than usually reached with conventional HPLC techniques. Depending on the actual benzodiazepine species, detection limits are in the range of 2.0 to 14.1 ng/mL. Mean recovery values of the drugs from blood range from 82 to 92%; within-day and day-to-day repeatabilities typically lie between 3 and 9%. Several case work examples demonstrate the high selectivity and remarkably low matrix sensitivity of the described assay.

Anti-Anxiety Agents↗

Determination of Delta9-tetrahydrocannabinol from rabbit plasma by gas chromatography-mass spectrometry using two ionization techniques.

The purpose of the study was to develop a gas chromatography-mass spectrometric (GC-MS) method for the identification and quantitation of Delta(9)-tetrahydrocannabinol (THC) in rabbit plasma. Two ionization techniques were utilized for GC-MS: electron impact ionization (EI) after i.v. administration and negative chemical ionization (NCI) after sublingual administration. THC was isolated from plasma by solid phase extraction and derivatized by either trimethylsilylation (EI) or trifuoroacetylation (NCI), with deuterated THC as an internal standard. The validity of analytical method was confirmed by investigating selectivity, limit of quantitation, linearity, accuracy, precision, recovery and stability of the analyte. The method proved to be selective, linear, accurate and precise over a range of 10-430 and 0.3-530 ng/ml of THC in plasma for EI and NCI, respectively. The extraction recovery was >81% for each concentration level studied, and the analyte was shown to be stable during storage and sample preparation. The method was applied successfully in analysing THC from rabbit plasma.

Absorption↗

Hair as a biological indicator of drug use, drug abuse or chronic exposure to environmental toxicants.

In recent years hair has become a fundamental biological specimen, alternative to the usual samples blood and urine, for drug testing in the fields of forensic toxicology, clinical toxicology and clinical chemistry. Moreover, hair-testing is now extensively used in workplace testing, as well as, on legal cases, historical research etc. This article reviews methodological and practical issues related to the application of hair as a biological indicator of drug use/abuse or of chronic exposure to environmental toxicants. Hair structure and the mechanisms of drug incorporation into it are commented. The usual preparation and extraction methods as well as the analytical techniques of hair samples are presented and commented on. The outcomes of hair analysis have been reviewed for the following categories: drugs of abuse (opiates, cocaine and related, amphetamines, cannabinoids), benzodiazepines, prescribed drugs, pesticides and organic pollutants, doping agents and other drugs or substances. Finally, the specific purpose of the hair testing is discussed along with the interpretation of hair analysis results regarding the limitations of the applied procedures.

Doping in Sports↗

Sample preparation and determination of gabapentin in venous and capillary blood using liquid chromatography-tandem mass spectrometry.

An analytical method for the determination of gabapentin in serum obtained from venous blood samples has been developed using high-performance liquid chromatography (HPLC)-tandem mass spectrometry. In addition, a comparative study between capillary plasma samples and venous serum samples was carried out. This demonstrates the potential for the use of the described analytical system using very small amounts of blood. As internal standard (S)-(+)-alpha-amino-cyclohexane-propionic acid hydrate was used. Gabapentin and the internal standard are structural isomers, but have different m/z values for the fragments after collision induced dissolution. Gabapentin has 172-->154 and 172-->136 transitions and amino-cyclohexane-propionic acid hydrate has a 172-->126 transition which can be detected in tandem MS. Analysis of gabapentin was carried out on a C8 HPLC column using an isocratic mobile phase consisting of ammonium acetate (pH 3.0; 5mM)-methanol (96:4, v/v). The analytical method was validated for venous serum samples. Limit of detection was 1.6ng/ml and lower limit of quantification was 7.5ng/ml. R.S.D. values and bias values were within the range of acceptance for all concentration levels. The method developed for venous serum samples is being used in a gabapentin monitoring study using population pharmacokinetic modeling.

Acetates↗

Simultaneous determination of artificial sweeteners, preservatives, caffeine, theobromine and theophylline in food and pharmaceutical preparations by ion chromatography.

A novel ion chromatographic method was proposed for the simultaneous determination of artificial sweeteners (sodium saccharin, aspartame, acesulfame-K), preservatives (benzoic acid, sorbic acid), caffeine, theobromine and theophylline. The separation was performed on an anion-exchange analytical column operated at 40 degrees C within 45 min by an isocratic elution with 5 mM aqueous NaH2PO4 (pH 8.20) solution containing 4% (v/v) acetonitrile as eluent, and the determination by wavelength-switching ultraviolet absorbance detection. The detection limits (signal-to-noise ratio 3:1) for all analytes were below the sub-microg/ml level. Under the experimental conditions, several organic acids, including citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various food and pharmaceutical preparations, and the average recoveries for real samples ranged from 85 to 104%. The levels of all analytes determined by this method were in good agreement with those obtained by the high-performance liquid chromatographic procedure. The results also indicated that ion chromatography would be possibly a beneficial alternative to conventional high-performance liquid chromatography for the separation and determination of these compounds.

Caffeine↗

Development and validation of a sensitive quantification method for hematoporphyrin monomethyl ether in plasma using high-performance liquid chromatography with fluorescence detection.

A rapid, sensitive, precise and specific method for determination of hematoporphyrin monomethyl ether (HMME), a novel photodynamic therapy (PDT) drug, was developed and validated using high-performance liquid chromatography (HPLC) with fluorescence detection. HMME was isolated from the plasma by a single-step liquid-liquid extraction with ethyl acetate. The analyte and internal standard fluorescein were baseline separated on a Diamonsil C(18) analytical column (4.6 x 150 mm, 5 microm) and analyzed using a fluorescence detector with the excitation and emission wavelengths set at 395 and 613 nm, respectively. The method was linear in the concentration range 0.025-5 microg/mL with a lower limit of quantitation (LLOQ) of 10 ng/mL. The inter- and intra-day accuracies and precisions were all within 10% and the mean recoveries of HMME and fluorescein were 95 +/- 3.7 and 90 +/- 2.3%, respectively. The analyte was stable during all sample storage, preparation and analysis periods. This method was successfully applied to a pharmacokinetic study after a single-dose intravenous administration of HMME (5 mg/kg) to beagle dogs. This method was reproducible and sensitive enough for the pharmacokinetic study of HMME. Based on the results of the pharmacokinetic study, we suggest that a rather long light-avoiding time is essential for patients under HMME therapy.

Animals↗

Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.

Selective, accurate, and reproducible liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of mevalonic acid, an intermediate in the biosynthesis of cholesterol and therefore a useful biomarker in the development of cholesterol lowering drugs, in human plasma and urine. A hepta-deuterated analog of mevalonic acid was used as the internal standard. For both methods, calibration standards were prepared in water, instead of human plasma and urine, due to unacceptably high levels of endogenous mevalonic acid. The lower quality control (QC) samples were prepared in water while the higher QC samples were prepared in the biological matrices. For the isolation/purification of mevalonic acid from the plasma and urine matrices, the samples were first acidified to convert the acid analyte into its lactone form. For the plasma samples, the lactone analyte was retained on and then eluted off a polymeric solid-phase extraction (SPE) sorbent. For the urine method, the sample containing the lactone analyte was passed through a C-18 SPE column, which did not retain the analyte, with the subsequent analyte retention on and then elution off a polymeric SPE sorbent. Chromatographic separation was achieved isocratically on a polar-endcapped C-18 analytical column with a water/methanol mobile phase containing 0.5 mM formic acid. Detection was by negative-ion electrospray tandem mass spectrometry. The standard curve range was 0.500-20.0 ng/mL for the plasma method and 25.0-1,000 ng/mL for the urine method. Excellent accuracy and precision were obtained for both methods at all concentration levels tested. It was interesting to note that for certain batches of urine, when a larger sample volume was used for analysis, a high degree of matrix effect was observed which resulted not only in the attenuation of the absolute response, but also in a change of analyte/internal standard response ratio. This demonstrated that, under certain conditions, the use of a stable isotope analog internal standard does not, contrary to conventional thinking, guarantee the constancy of the analyte/internal response ratio, which is a prerequisite for a rugged bioanalytical method. On the other hand, under conditions where the sample matrix does not have such a deleterious effect, we have found that a stable isotope analog could serve as a surrogate (substitute) analyte. Thus, we have shown that using calibration standards prepared by spiking plasma with tri-deuterated or tetra-deuterated mevalonic acid, instead of mevalonic acid itself (the analyte), plasma QC samples that contain mevalonic acid can be successfully analyzed for the accurate and precise quantitation of mevalonic acid. The use of a surrogate analyte provides the opportunity to gauge the daily performance of the method for the low concentration levels prepared in the biological matrix, which otherwise is not achievable because of the endogenous concentrations of the analyte in the biological matrices.

Chromatography, Liquid↗

Determination of deramciclane and N-desmethylderamciclane in human plasma by liquid chromatography-tandem mass spectrometry using off-line robotic sample pretreatment.

A rapid and highly sensitive LC-MS-MS method using deuterium-labelled internal standards was developed and evaluated for the simultaneous determination of deramciclane and its pharmacologically active metabolite (N-desmethylderamciclane). The sample preparation based on liquid-liquid extraction was carried out with an off-line robotic system. Evaluation of this analytical method shows that samples can be assayed with acceptable accuracy and precision in the 0.1 to 50 ng/ml concentration range for both compounds. The method was applied for the quantitative determination of deramciclane and its metabolite in human plasma samples during a food interaction pharmacokinetic study.

Calibration↗

Preparative purification of peptides by reversed-phase chromatography. Sample displacement mode versus gradient elution mode.

In this study, we describe a novel method of preparative liquid chromatography, applicable to analytical columns and instrumentation, where the reversed-phase column is operated in sample displacement mode (SDM). This technique takes advantage of the different relative hydrophobicities of components of a sample mixture, so that when a column is optimally loaded with an aqueous solution of the sample mixture, there is competition among the sample components for the adsorption sites on the hydrophobic stationary phase. The more hydrophobic components compete more successfully for these sites than more hydrophilic components, which are displaced and immediately eluted from the column. Thus, the major separation takes place in water. Subsequent treatment with an aqueous organic eluent is only required to wash retained components off the column and takes no part in the major separation process. A two-column (precolumn and main column, in series) SDM strategy was applied to the preparative purification of a peptide product from neighbouring hydrophilic and hydrophobic impurities. Hydrophobic impurities were isolated on a shorter precolumn trap while hydrophilic impurities were displaced from the main column in the aqueous mobile phase (0.05% aq. trifluoroacetic acid), leaving the main column filled with homogeneous product. Gradient elution was then used to remove the peptide product from the main column. The researcher can regulate the size of the precolumn trap depending on the amount of hydrophobic impurities in a particular sample, or the size of the main column depending on the amount of product desired. The simplicity and flexibility of the SDM approach to preparative-scale purification enabled rapid separation of a single peptide component from a complex multicomponent mixture and should prove to be valuable for researchers in the peptide/protein field.

Chemical Phenomena↗

Direct integration of pervaporation as a sample preparation method for a dedicated "electronic nose".

The present study investigates the possibility of monitoring the bioproduction of a complex aroma profile with an analytical electronic aroma-sensing technique, the so-called "electronic nose", combined with a pervaporative sample enrichment method necessary to overcome the ethanol interference on the sensors' response. It presents in detail the development of a direct integrated pervaporation-electronic nose unit for a simple and fast analysis, which are key criteria for this technique to be broadly implemented. The system developed was investigated using model solutions simulating the muscatel wine must fermentation. It proved to be able to evaluate different relevant aroma compounds in solutions of varying degree of complexity, and also in the presence of ethanol, which is a major interference on the sensors' response to the aromas. The transient sensors' response was investigated in detail, revealing information for sample discrimination and reducing the analysis time. The system developed allowed a simple, fast, and selective analysis, therefore permitting a high sample throughput over time, with the possibility of fully automation.

Electrons↗

Direct determination of selenium and other trace elements in serum samples by ICP-MS.

Selenium belongs to a group of trace elements of special interest in biological samples for clinical diagnosis. Selenium has antioxidizing functions and is essential for providing the organism with triiodothyronine produced from thyroxine. Among several analytical techniques used to determine the Se concentration in serum, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) has been used in the past because of its high sensitivity. Interference problems originating from different ions on the major Se isotopes have been described to be a limiting factor for the direct determination of Se in these matrices. Standard addition calibration or isotope dilution is often required to overcome carbon-enhanced ionisation effects in biological sample matrices. In most cases, the typical serum sample volume which is available for the analysis is limited to 0.5 ml or less, making multiple sample preparation for standard addition calibration impractical. Isotope dilution requires enriched isotopes and substantial sample preparation. Furthermore, the approximate Se concentration in every sample has to be known to adjust the appropriate amount of spike to each sample. Matrix matching with methanol has been described to overcome ionisation effects but we found limiting factors of this application when other trace elements are also determined within one sample run. This paper describes an effective sample preparation method which allows the direct determination of Se in serum without limiting the analytical capabilities for the additional determination of Al, Cu, Ni, Co, Cd, Mn and Zn in a single sample run by ICP-MS. Optimization procedures are presented and results of the analysis of reference samples are discussed, with a comparison of more than 150 serum data with those obtained by the GF-AAS method.

Animals↗

Proposal of an analytical method for the study of the oxidation products of membrane lipids.

A method of lipid sample preparation for GLC and GC-MS analysis is presented which would seem particularly suitable for studying the chemical composition of the oxidation products of membrane lipids. The method requires small amounts of lipid, is quite rapid and avoids the formation of oxidation artifacts during the different analytical steps. Due to the small quantities of lipid material used it is possible that the method is not rigorously quantitative. Transmethylation of lipids is carried out with methanolic NaBH4 in the presence of NaOH. The reaction is complete in 20 min both on neutral and on polar lipids. In the course of the transmethylation the hydroperoxidic groups are reduced to the corresponding hydroxy groups and can be located through the GC-MS spectra of the corresponding TMS derivatives. The epoxidic rings that may be present are not hydrolyzed. They are located by opening the ring with BF3/MeOH and by GC-MS analysis of the corresponding methoxy-hydroxy derivatives.

Chromatography, Gas↗

Simultaneous determination of tanshinone IIA and its three hydroxylated metabolites by liquid chromatography/tandem mass spectrometry.

A rapid and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of tanshinone IIA and its three hydroxylated metabolites, tanshinone IIB, hydroxytanshinone IIA and przewaquinone A, in a rat liver microsome was developed and fully validated. A single step of liquid-liquid extraction with ethyl acetate was utilized in this method. Chromatographic separation of the sample matrix from the analytes and the internal standard diazepam was performed using a Shim-pack VP-ODS analytical column. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source and operated in selected reaction monitoring (SRM) mode. The method was linear in the concentration range of 1-500 ng/mL for all analytes. The intra- and inter-day precisions (RSD %) were within 15% and deviations of the assay accuracies were within 15.0% for all analytes. The analytes proved to be stable during sample storage, preparation and analyses. This validated method was successfully applied to the enzyme kinetic study of tanshinone IIA in liver microsome. The elimination of tanshinone IIA and formation of tanshinone IIB and hydroxytanshinone IIA in the liver microsome all exhibited a sigmoidal kinetics profile. The formation of przewaquinone A shows a typical hyperbolic profile. In addition, this method has now been applied in the analysis of other bio-samples including plasma, urine, bile and feces.

Abietanes↗

Atomic emission detection for gas chromatographic analysis of nitrogen-containing herbicides in water.

A gas chromatography-atomic emission detection (GC-AED) system was used to analyze nitrogen-containing herbicides. Two methods of sample preparation were used to demonstrate the system's applicability. Method 1 was U.S. Environmental Protection Agency (EPA) Method 507. Method 2 was a modification of EPA Method 507 using larger sample volumes and smaller extract volumes to yield compound detection levels 30 times lower than detection levels from method 1. Analysis of replicate reagent water spikes with method 1 gave analyte recoveries ranging from 82 to 107%, with standard deviations of recovery of not more than 6.7%. Method 2 gave recoveries ranging from 50 to 112%, with a standard deviation of recovery of not more than 33%. A loss in recovery and precision with method 2 compared with method 1 was attributed to loss of more volatile analytes during extract concentration. Selectivity was demonstrated with solvent spiked with fuel oil and atrazine. Response factors generated with the GC-AED system showed compound-independent elemental linearity for analytes. Relative standard deviations of not more than 5.34% were obtained for 3 elements tested: nitrogen, sulphur, and chlorine. An elemental calibration mixture was prepared to validate traditional methods of quantitation. Samples were analyzed for nitrogen-containing herbicides, which were quantitated with both an analyte calibration and an elemental calibration, and results were compared.

Calibration↗