Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VIBRATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

[Method of detecting excitability of skin receptors in the diagnosis of vibration disease].

The follow-up studies of patients with vibration disease caused by local vibration proved diagnostic value of minor skin response of dorsal hand surface and anterior surface of arm or forearm, if subjected to irritation with mixture of chloroform and ethanol. Depressed skin receptors during the disease are diagnosed through longer latent period of burning sensation in two of three points irritated on skin of the upper limb. The diagnostic method based on chemical stimulation of skin receptors is highly sensitive (86.9%) and specific (94.4%), especially for early stages of the disease, promoting detection of subclinical peripheral neuropathy caused by vibration. Due to its simplicity and availability the method could replace algesimetry in mass screening among workers exposed to vibration.

Chloroform↗

[Hand and arm vibration syndrome caused by mechanical screw driver].

Authors performed angiological, neurological and radiological examination of 17 persons working with power screw-drivers. Vibration measurement of the tools was made too. 10 patients had symptoms and signs corresponding to the hand-arm vibration syndrome. The vibration of some tools exceeded the maximal allowable acceleration level according to ISO 5349. On the ground of the results authors conclude that some power screw-drivers can cause hand-arm vibration syndrome. The importance of choosing of the right tools and the significance of the periodical examinations are underlined in the prevention of the damages.

Adult↗

Analysis on decay rate of vibration following impact to human dry skull with and without mouthguards.

The modal analysis on vibration in the human dry skull with and without mouthguards was performed in order to clarify which elasticity modulus of the material and what form of the mouthguard are best. Nine different mouthguards were prepared for this study from three materials with different elasticity moduli amd three different forms: Soft MOLTENO (registered) mouthguards of long, middle, and short forms. Regular MOLENTO (registered) mouthguards of long, middle and short forms, and Hard MOLENTO(registered) mouthguards of long, middle and short forms. Thirty-five measurement points were established on the skull. The main measurement system was composed of a 512-D Vibration Generator, LV-1300 Laser-Doppler Vibrometer, CF-6400 FFT Analyzer, PC-9821Xn personal computer, and Vibrant PC modal analysis software. The decay rate was calculated to evaluate effectiveness of the absorption of vibration of the skull with and without mouthguards when stress was put on the skull. The results showed that he skull fitted with the long and middle mouthguards made of regular MOLTENO (registered) had a higher decay rate than the skull w the mouthguard, and that the material properties of the mouthguards influenced the absorption of the skull vibration more intensively that did the forms of the mouthguards.

Adult↗

[Conditioned trace reactions of hypothalamic neurons following exposure to vibration].

Trace reactions were studied in 112 hypothalamic units in rabbits during motor defensive conditioning to time after vibration action of two intensities. A later formation of conditioned trace reactions was observed as compared to the control. Vibration of lesser intensity improved the course of trace processes and slightly increased the number of neurones responding to the conditioned stimulus (45% as against 43% in the control); after a stronger vibration action, conditioned reactions to time were recorded only in 29% of the hypothalamic cells eith a simultaneous diminution of the trace response. It has been assumed that the observed transformations result from changes of the significance of the reinforcing factor in the formation of a motor defensive conditioned reflex after the action of vibration.

Animals↗

[Clinical picture of vibration syndrome and diagnostic principles].

The author discussed health effects of occupational exposure to local vibration, taking into account classification of a clinical manifestation of vibration syndrome and its symptoms. The principles of subjective and objective evaluations of workers occupationally exposed to mechanical vibrations were laid down as well as conditions for correct diagnosis of vibration syndrome.

Humans↗

Integrated stand for vibration and ergonomic investigations of hand-held impact tools.

This paper presents an integrated test stand for hand-held impact tools (rnu) enabling complex vibration and ergonomic investigations according to the standards ISO 8662, EN 28662 and EU directives. The stand testing range has been established basing on the system investigations (1) concerning all the factors harmful to the operator's health existing on the work stands equipped with rnu. The parameters of rnu supply which should be monitored and recorded during investigations have been also established. Course of investigations is controlled by a computer provided with the original SYS-DEA program (7). The integrated stand is equipped with a Quality Assurance System of investigations making impossible measurement and recording of erroneous signals. Simultaneous acquisition, measurement and recording of fourteen signals are done during the course of investigations. This paper contains a short description of stand design and the results of comparative investigations conducted with use of new generation of pneumatic hammers as a source adapted for man-operator requirements (5). Comparative investigations showed that the mechanical part of the stand simulates dynamic conditions of a man-operator and rnu investigations without presence of operators are possible. Moreover, the stand makes possible very good repeatability of tool fastening and supplying. Vibration spectrum correlation coefficient for particular fastening in the stand is in the range: 0.967-0.994 and is decidedly higher than the operator's pushing force. Vibration investigations revealed design drawbacks of the impact energy absorber made according to the standards SO 8662 and EN 28662 that should be eliminated. Results of the rnu investigations attained in the integrated stand make possible a complex evaluation of tested tools not only in the range of vibration and noise but also in the range of the most important ergonomic parameters connected with for example operator's physical overload and issue of certificates by certifying units.

Equipment Design↗

Raynaud's phenomenon in different groups of workers using hand-held vibrating tools.

The dose-effect relationship showed in the Annex A of the ISO standard 5349-1986 can be used for preventing vibration-induced white fingers (VWF) because it allows to calculate the latent period for the lowest risk of VWF. The aim of this study was to assess the risk of VWF in three different occupational groups of workers whose members operated the same vibrating power tools and the same industrial processes throughout the workday. Each occupational group was employed in two foundries and they were considered to be very stable with a low turnover rate. The mean frequency-weighted acceleration magnitudes measured from pneumatic rammers (25.3 +/- 3.3 ms-2) where three times higher than from chipping hammers (8.4 +/- 3.8 ms-2) and six times higher than from grinders (3.8 +/- 1.1 ms-2). Medical examinations were carried out in 102 men consisting of 22 chippers, 42 rammers and 38 grinders. The results of this study showed that the relationship between lifetime exposure to hand-arm vibration and the vascular disorders can be predicted quite well using the Annex A of ISO standard only in one occupational group, that is, in chippers. Thirty-six percent of chippers reported blanching symptoms, but only five percent of the rammers and three percent of the grinders had these vascular disturbances. Our results may be explained by the fact that vibration received by an operator depends on the manner in which the tool is used. In a foundry three following work processes are performed: preparing forms in ramming mix, cleaning and grinding of castings during which different forces are used by operators. It seems very likely that the energy absorbtion in the hands and arms of chippers must be stronger than in other studied groups.

Adult↗

Application of a new technology to the design of effective anti-vibration gloves.

Gloves that attenuate vibration above approximately 25 Hz and that exceed the characteristics of standard viscoelastic gloves have been developed using an air bladder system in the palm and fingers of a glove. Testing was performed on a variety of viscoelastic gloves currently marketed to obtain the ratio of energy leaving the handle of a vibrating device and the energy entering the hand. Several simple rectangular air bladders of varying thickness were developed and tested for their vibration attenuating characteristics. A four degree-of-freedom, lumped-parameter model of the vibration response of the human and air bladder was developed using measured hand and bladder parameters. This model, along with subjective criteria, was used to design and fabricate two prototype air bladder gloves. These gloves were tested and found to exceed adopted standard requirements and the characteristics of standard viscoelastic gloves. The prototypes in this study will be further developed, adapted and marketed for practical applications.

Air↗

[Hygienic evaluation of the effects of vibration and arsenic in miners engaged in extraction of arsenic-containing ore].

Hygienic evaluation covered work conditions on 4 gold mines including 3 ones for gold and arsenic and one "arsenic-free". The mines demonstrated similar occupational factors, but differed in arsenic content of the ore extracted and therefore in arsenic concentrations in air of the workplaces. Miners engaged into extraction of the arsenic-containing ore, especially those exposed to vibration and arsenic concentrations over the MAC, manifest extensive arsenic accumulation in the hair and excretion with the urine, higher morbidity with transitory disablement, more prevalent vibration disease and mortality with malignancies. Vibration disease in those subject has more severe course, serious vegetative and sensory polyneuropathy, that is believed to result from co-action of vibration and arsenic.

Air Pollutants, Occupational↗

Clinical studies of the vibration syndrome using a cold stress test measuring finger temperature.

Since nine years multicentre, transversal and longitudinal clinical studies on hand-arm, vibration-exposed patients are being performed in cooperation with French occupational medicine centers and social security institutions. These studies are based upon current clinical assessment and standardized, temperature-measuring cooling tests. Data acquisition uses a portable, 10-channel, micro-processor-based temperature recorder and miniature thermal sensors. Temperature is monitored at the ten finger tips continuously, before, during and after a cold stress performed in strictly controlled conditions. Data from examinations performed at outlying sites are transferred through the telephonic network to a central processing unit. Data analysis uses a specific, expert-type software procedure based upon previous clinical studies on (i) 238 "normal" subjects, and (ii) 3,046 patients with vascular disturbances of the upper extremities of various etiologies. This procedure includes a staging process which assigns each finger a class representing the degree of severity of the abnormalities of response to cold ("dysthermia") related to vascular disorders. All data processing is fully automatic and results in a printed examination report. To date, over 1,623 vibration-exposed forestry, building and mechanical workers were examined. Sixty-three per cent of patients had received high dose of vibration (daily use of chain saws, air hammers, ballast tampers over many years). Typical white finger attacks or only neurological symptoms were found in 36% and 23% of patients respectively. The rate of sever dysthermia was much higher in patients with white finger attacks (83%) than in patients without (32%). In 90% of the vibration-exposed patients, the severity of dysthermia has differed greatly from one finger to another and between hands, while in non-exposed patients with primary Raynaud syndrome the dysthermia are generally similar for all fingers but the thumbs. Of 208 forestry workers who were asymptomatic but had dysthermia on a first examination, 31% have developed vascular or neural symptoms within subsequent follow-up. Of 223 symptomatic patients with more or less severe dysthermia at a first examination performed in winter, 17% had the same abnormalities in summer and microvascular lesions at capillaroscopy, while the other 83% had reversible dysthermia and only functional capillaroscopic abnormalities. These studies suggest that temperature-measuring cooling tests performed under well-defined, standard conditions provide significant data for grading the severity and assessing the reversibility of Raynaud phenomena, and for detecting subclinical vasomotor disorders in asymptomatic patients.

Adolescent↗

Digital nerve conduction velocity for evaluation of peripheral nerve impairments in vibration syndrome.

In order to evaluate peripheral nerve impairments in vibration syndrome, sensory nerve conduction velocity (SCV) in the digital segment of the median nerve was measured by applying electrical stimulation to the wrist and recording from two pairs of electrodes attached to the middle finger. Fractionated SCVs were also measured in the palm-to-finger, wrist-to-palm, and elbow-to-wrist segments of the median nerve. Subjects were 65 patients with vibration syndrome and 48 healthy controls of similar age. SCVs in the digital nerve segment were significantly slower in the patients than in the controls. Significant slowing was also found in the wrist-to-palm segment. SCVs in the palm-to-finger and elbow-to-wrist segments did not differ between the two groups. Slowed SCVs were most frequently encountered in the digital segment (38% of the patients). The slowing in the wrist-to-palm segment was found in 20% of the patients. Present findings indicate that the digital segment is most frequently affected in vibration-induced neuropathy, and measurement of SCVs in the digital segment would serve to evaluate the peripheral neuropathy in vibration syndrome.

Case-Control Studies↗

Response to psychological stressors in hand-arm vibration syndrome patients.

We investigated urinary catecholamines' response to acute psychological stress test in hand-arm vibration syndrome patients. Thirteen patients with vibration-induced white finger (VWF) in higher frequency of attack, 7 patients with VWF in lower frequency, 6 patients without VWF and 17 healthy subjects were examined. All subjects were male and their average age (SD) was 59.2 (6.4), 56.3 (2.9), 58.2 (4.7) and 56.8 (4.9), respectively. After an initial rest for 1 hour, acute psychological stress test with stressors--mirror drawing, watching horror video and arithmetic under intermittent noise was performed for 1 hour. Subjective complaints to the stress test were greater in patients with hand-arm vibration syndrome than in the healthy controls. The patient group with VWF in higher frequency indicated significant increases of urinary catecholamines (p < 0.05); average values (SD) at rest period and at stress test were 2.42 (1.17) and 3.71 (1.82) micrograms/h for norepinephrine, and 1.47 (0.73) and 2.66 (1.79) micrograms/h for epinephrine, respectively. Increasing tendency of urinary catecholamines was observed in other three groups, however, they were not statistically significant. The sympathoadrenal medullary response to psychological stressors increased especially in hand-arm vibration syndrome patients with VWF in higher frequency.

Biomarkers↗

Preliminary observations on interventricular septum vibrations: an echocardiographic sign in aortic valvular stenosis.

In previous experimental and clinical studies on aortic valvular stenosis it has been suggested that in addition to the degree of stenosis, other factors, such as the pathoanatomy of the valve and turbulence-induced vibrations, might be of importance. Using echocardiography, vibrations of the interventricular septum were demonstrated in six consecutive patients with congenital aortic stenosis. In comparable normal subjects no such vibrations could be seen. The clinical significance of ventricular wall vibrations has not yet been established.

Adolescent↗

[Hand-arm vibration syndrome in caisson miners].

Authors examined 43 caisson-miners with symptoms of the upper extremities because of suspicion of hand-arm vibration syndrome. Also vibration measurements were performed on the pneumatic hammer used by the workers. The acceleration of the vibration exceeded 2.5-3.5 times the maximum allowable level according to the ISO 5349. Symptoms and signs of hand-arm vibration syndrome were found in 39 cases (90.7%). The vascular, peripheral neurological and locomotor system of the upper extremities were affected in similar frequency: 54.8; 51.6 and 51.2%, respectively. The most common angiological alteration was the Raynaud's phenomenon. Neurologically predominated the tunnel syndromes. Among the osteoarticular lesions the degenerative phenomena were the most frequent. In most cases more than one pathological alteration occurred. Fatigue fracture of the spinous process of vertebra D. I. appeared in one single case, degenerative changes of cervical spine in 34 patients (79.1%). The very common occurrence of the locomotor alterations and tunnel syndromes respectively can be explained probably also by the high physical stress required by this profession. The detailed examination of the locomotor system is very important by the periodical screening of the caisson-miners.

Adult↗

Aberrations in postural control, vibration sensation and some vestibular findings in healthy 64-92-year-old subjects.

To assess changes in postural control among healthy elderly and to correlate with suspected age-related events, 33 women and 16 men were studied. Postural control was evaluated by vibration-induced body sway, measured on a force platform, and vibration sensation was tested with a tuning fork. Occurrence of spontaneous gaze and head-shake-induced nystagmus was observed with infrared charged couple device (CCD) cameras and the subjects' medical history was reviewed. Vibration perception was the major determinant for the magnitude of body sway. Although these senior citizens considered themselves healthy, they had a variety of ailments in their medical history, diminished vibration sensation and a high prevalence of vestibular asymmetry. Age per se was not a determinant factor in any of the findings. The study suggests that interest should also be directed to the status of sensation in the legs and vestibular asymmetry when assessing balance function in the elderly. Furthermore, the term "age concomitant" may be more appropriate than "age dependent" when describing decrements of functions such as postural control in elderly subjects.

Aged↗

Comparison of the subjective intensity of sinusoidal, multifrequency, and random whole-body vibration.

An intensity matching technique was used in two experiments to test the independent component method for evaluating complex vibration environments, recommended by current vibration standards; In the first experiment, seated subjects adjusted the intensity of a 25 Hz sinusoid to match the subjective intensity of 11, 17, 40, and 63 Hz simusoids, presented either singly or in combinations of two, three, or four frequencies. In the second experiment, 25 Hz was again used to match the subjective intensity of third octave bands of random vibration with center frequencies of 16, 20, 25, 31;5, and 40 Hz, presented either singly or in combinations of two, three, or four bands. The results showed that the acceleration of the matching response increased significantly as the number of sinusoids or third-octave bands in the stimulus increased; These findings indicate that the independent component evaluation method will underestimate the severity of complex vibration environments, and suggest that their perceived intensities may be more accurately reflected by the weighting technique included in the standards as an alternative evaluation method.

Acceleration↗

Surface integrity of composite inlays following ultrasonic vibration.

PURPOSE: To assess the effect of ultrasonic vibration on the surface integrity of a resin composite inlay. MATERIALS AND METHODS: Ultrasonic vibration in the form of a scaling tip oriented either parallel or perpendicular to the surface was applied to 2 mm thick, 10 mm wide composite discs and the experiment was repeated with the probe oriented perpendicular using composite or rubber shields. The indentations produced were measured using a form Talysurf profilometer. The surfaces of the discs were also observed using scanning electron microscopy. Five discs were used for each experiment. RESULTS: Both parallel and perpendicular orientations produced an indentation with a scattering of composite debris. A significant increase in the depth of indentation occurred if the vibrations of the ultrasonic scaler were oriented parallel to the composite surface (Two sample t- test, P < 0.01). The presence of a composite shield significantly reduced (Mann-Whitney, P < 0.05) the depth of indentation but produced roughening of the surface with impaction of material from the shield onto the surface. The rubber shield, however, polished the surface significantly smoother than the control specimens (Mann-Whitney, P < 0.05). Microscope slide separation was used to measure the thickness of composite luting agent following vibration with an ultrasonic scaling tip with and without a protective sleeve. There was a significantly thinner film of luting agent when an unsleeved scaler was used (ANOVA, P < 0.001). Although an unguarded tip oriented perpendicular to the surface appears to result in the best energy transfer for a thin layer of composite luting agent, it does, however, create minimal surface damage.

Analysis of Variance↗

[The results of a morphological study of the gastric and duodenal mucosae in patients with vibration-induced disease].

AIM: Morphological study of gastric and duodenal mucosa in patients with vibration disease. MATERIALS AND METHODS: 64 patients with vibration disease stage I and II were examined endoscopically, histologically, bacterioscopically and morphometrically irrespective of the presence or absence of gastrointestinal complaints. RESULTS: Erosive gastroduodenitis, non-erosive gastroduodenitis and gastritis, polyps in the stomach and gastric ulcer were diagnosed in 19(29.7%), 40(62.5%), 2(3.2%) and 1(1.6%) patients, respectively. Small intestinal metaplasia occurred in 22% of patients. Helicobacter pylori occurred most frequently in the antral part of the stomach (90.24%). Advanced dissemination often combined with metaplasia of the small bowel. Morphometrically, there were slight differences from relevant values in patients with chronic gastroduodenitis who were not exposed to occupational hazards. Vibration disease patients exhibited impairment of duodenal vessels (large endothelial nuclei, thick arteriolar walls) 2 times more frequently than controls. CONCLUSION: In vibration disease, gastric and duodenal mucosa, as a rule, shows signs of chronic gastroduodenitis.

Adult↗

Refine your search to explore more results.