Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Trace Elements”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

[The influence of the feeding type on the concentration of trace elements in the hair of infants].

The aim of this study was to assess hair magnesium, iron, copper, and zinc levels in breast-fed and formula-fed infants. Our findings showed that concentration of the assayed macro- and trace elements, except copper, were higher in breast-fed children and declined with age, faster in formula-fed children. The frequent occurrence of magnesium deficiency indicates that pregnant women should receive magnesium supplementation.

Copper↗

Milestones in biological trace element research.

Over 100 years ago, macro-scale analytical techniques were used to discover the roles of special compounds (especially of metallic elements) in living organisms, and investigations were focussed on selected proteins and pigments suspected of containing percentage quantities of metals. In contrast, present-day analytical techniques are capable of detecting extremely small quantities and have become routine ultra-trace measurement tools to probe elemental interactions at cellular levels. The scientific achievements connecting these two boundaries are punctuated with an array of analytical developments; some highlighting the phenomenal advances in the measurement technology and others reflecting the exceptional bioanalytical perception and the multi-disciplinary outlook of trace element investigators. An account of the events that contributed to the overall progress in biological trace element research is the essence of this communication.

Adult↗

Role of antioxidants in the protection against oxidative stress in cattle--trace elements and enzymatic mechanisms (Part 3).

The most important enzymatic mechanisms which protect an organism against oxidative stress are superoxide dismutase (SOD), peroxidase (Px), e.g. glutathione peroxidase (GSH-Px) and ascorbate peroxidase, catalase and glutathione reductase. Their activity depends on many trace elements. Enzymatic mechanisms, functioning under physiological conditions, prevent the spread of free radical reactions. New and reoccurring metabolic and infectious diseases of cattle emerge when there is a disproportion in the balance between reactive oxygen species and antioxidative enzymatic barrier.

Animal Feed↗

Trace elements in parenteral micronutrition.

OBJECTIVE: To update some essential trace metals required in total parenteral nutrition. CONCLUSION: Essential trace metals, chromium, copper, manganese, molybdenum, selenium, and zinc are added to parenteral fluids to prevent the development of deficiency syndromes. When possible, these metals should be monitored, even in patients on short-term total parenteral nutrition (TPN) to avoid deficiency or toxicity. Many of the nutrients or additives used in parenteral solutions may be contaminated with metals, such as aluminum or chromium. Such trace-metal monitoring becomes more critical in infants, and those on long-term TPN.

Adult↗

Temporal and spatial studies of autocatalyst-derived platinum, rhodium, and palladium and selected vehicle-derived trace elements in the environment.

The distribution of platinum, rhodium, and palladium (platinum-group elements; PGEs) adjacent to two major U.K. roads shows a rapid decrease (more than 1 order of magnitude) away from the road and reflects patterns shown by other traffic-derived trace elements such as Pb and Zn. However, ratios of Pt:Rh remain relatively constant from 0 to 10 m distance, suggesting that at least some of the PGEs are transported away from the source. A temporal study over a 12-month period, of road dust and surface samples, reveals elevated concentrations above background levels, with maximum values of Pt >500 ng g(-1), Rh 70 ng g(-1), and Pd 70 ng g(-1). Concentrations vary considerably throughout the year and show some tentative correlation with rainfall. Element speciation, an essential control on mobility and hence distribution, was investigated, and the results of solubility experiments show that up to 30% of the Pd present dissolves in acid solutions. This indicates that at least some of the Pd is present in a soluble form and is therefore potentially highly mobile.

Air Pollution↗

Trace elements and chlorinated hydrocarbons in eggs of Pelecanus crispus, a world endangered bird species nesting at Lake Mikri Prespa, North-western Greece.

Eggs of the Dalmatian pelican, Pelecanus crispus, collected from 1984 to 1986 at Lake Mikri Prespa, north-western Greece, contained residues of trace elements and PCBs at low concentrations, and of DDE at rather high concentrations. DDE is negatively related to eggshell thickness. Eggshell thickness was reduced by 12-20% in comparison with the pre-1947 (before DDT use) eggshell thickness. However, this decrease did not affect the reproductive success of this species. The main fish species eaten by the Dalmatian pelican at Lake Mikri Prespa were analyzed for pollutants. All the fish contained low concentrations of residues. The contribution of the diet while the birds are on the wintering grounds is unknown. Recommendations for a monitoring programme of pollutants in eggs of the Dalmatian pelican, a world-endangered species, are proposed.

Journal Article↗

Analysis of biogenic carbonates by inductively coupled plasma-mass spectrometry (ICP-MS). Flow injection on-line solid-phase preconcentration for trace element determination in fish otoliths.

The aragonite deposits within the ear bones (otoliths) of teleost fish retain a chemical signal reflecting the life history of fish (similar to rings of trees) and the nature of fish habitats. Otoliths dissolved in acid solutions contain high concentrations of calcium and a variety of proteins. Elimination of matrix salts and organic interferences during preconcentration is essential for accurate determination of trace elements in otolith solutions by inductively coupled plasma-quadrupole mass spectrometry. An iminodiacetate-based chelating resin (Toyopearl AF-Chelate 650 M) has been used for on-line preconcentration and matrix separation for the determination of 31 transition and rare elements. Successful preconcentration of the elements was achieved at pH 5 by on-line buffering, except Mn which required pH 8.8. Sample solutions were loaded on to the column for 1 min at 3.2 mL min(-1), and then eluted directly into the mass spectrometer with 4% v/v nitric acid. This procedure enabled up to 25-fold preconcentration with successful removal of the calcium matrix. The effect of heat-assisted oxidation with concentrated nitric acid was investigated to eliminate the organic matrix. It was found that heating to dryness after dissolution and further mineralization with the acid significantly improved the retention of the transition elements. The method was validated by analysis of a certified reference material produced from saggittal otoliths of emperor snapper ( Lutjanus sebae), and then applied to the determination of trace metal concentrations in juvenile bluefin tuna ( Thunnus thynnus) from the Western Pacific Ocean.

Animals↗

Multisignal evaluation in ICP-MSDetermination of trace elements in Mo-Zr-alloy.

The existence of isobaric and polyatomic ion interferences has been considered to be a significant shortcoming of inductively coupled plasma - mass spectrometry (ICP-MS). In the special case of Mo-Zr-alloys problems caused by polyatomic ions are substantial. The determination of trace elements by using classical univariate linear regression of single signals or any correction equations presented by the instrumental software is impossible. There are various possibilities to overcome spectral interferences, in principle. The application of high-resolution ICP-MS, separation methods or alternative sample introduction systems is limited by the high cost and the apparative expenditure. In this report methods of multisignal calibration, like partial least squares (PLS) regression and canonical correlation analysis (CCA), are used to overcome isobaric or chemical interferences in ICP-MS. It is shown, that PLS and CCA are able to handle or tolerate, respectively, spectral interferences existing in a Mo-Zr-O-H-F system. The results of quantitative analysis provided by PLS and CCA were comparable.

Journal Article↗

Trace element biomonitoring by leaves of Populus nigra L. from Western Anatolia, Turkey.

The West Anatolian Region is one of the most important areas for industrialization, population density and traffic in Turkey. Therefore, the leaves of Populus nigra L. (Salicaceae), which are used as biomonitor to investigate the levels of the trace elements Cd, Pb, Fe, Zn and Cu, were sampled at 30 locations having different pollution levels in the region. The concentrations of elements were determined by atomic absorption spectrometry. The samples were collected at both reference and contaminated locations where iron was found as the priority element. The strong association between a gradient of contamination and concentration in all samples tested indicates that they are reflecting well the environmental changes, and that they appear as appropriate biological indicators of heavy metal contamination.

Environmental Monitoring↗

Refine your search to explore more results.