Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Rotation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

[Reconstruction of massive rotator cuff rupture using a deltoid muscle flap].

In extensive rotator cuff tears with rupture of the supra- and infraspinatus muscles, we have obtained good and very good results persisting for 3 years or longer only in 40% of cases treated by resection and debridement, and in 25% of our cases the head of the humerus was found to be no longer centrally located in the joint socket on X-ray examination 10 years after treatment. It was therefore proposed that an active muscle flap taken from the anterior part of the deltoid muscle (part III according to Fick) should be used to span the trophic defect in the rotator cuff, being sutured into healthy tissue following freshening up. This seems logical, since the transferred muscle flap remains innervated and vascularized and also works synergistically with the rest of the rotator cuff. The flap interposed in this way between the greater tubercle of the humerus and the acromion functions in the same way as a double-bellied muscle and prevents displacement of the head of the humerus. In this way an active rotator cuff is produced, which also takes over the function of stabilizing the humeral head. After follow-up of at least 1 year (average 19 months), the result is aesthetically satisfactory in all 50 shoulders treated in this way; 47 are free of pain or painful only some of the time; in 32 active elevation of over 120 degrees is possible; 21 have symmetrical force ratios in elevation and 15 for outward rotation in 90 degrees abduction. All reconstructed shoulders were characterized by fatigability in elevation.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Correlation between MRI and operative findings of the rotator cuff tear.

Rotator cuff disease is one of the most common causes of shoulder pain. Various methods have been used to evaluate this problem. In this study, we determine the accuracy of magnetic resonance imaging (MRI) of the shoulder in diagnosing the rotator cuff tear based on operative findings. Ten patients with a painful shoulder requiring operation received an MRI of the shoulder before surgery. A GE 1.5 Tesla MR scanner with a five-inch planar surface coil was applied and the diagnosis was confirmed by an experienced radiologist in the field of musculoskeletal MRI. All patients underwent surgery within two weeks of MRI examination. Nine of the 10 patients were shown to have rotator cuff tear by MRI. Among the nine MRI positive patients, eight were proven to have such lesions on operation (two massive tears, four moderate complete tears, and two bursal side tears). One false-positive result was found to be an adhesive capsulitis and supraspinatus tendinitis at operation. The remaining case, diagnosed as tendinitis by MRI, turned out to be a small incomplete tear on operation. Therefore, the sensitivity of MRI for rotator cuff tear in this study was 0.89. The overall accuracy was 80%. We concluded that MRI has a high accuracy in detecting the rotator cuff tear. False-positive and false-negative diagnoses were attributed to a severe tendinitis and an incomplete tear, respectively.

Adult↗

Isokinetic evaluation of rotational strength in normal shoulders and shoulders with impingement syndrome.

The purpose of this study was to determine whether imbalance of the internal and external rotator musculature of the shoulder were etiological factors implicated in impingement syndrome. Shoulder torque measurements were obtained from 15 asymptomatic volunteers and 30 patients with chronic impingement syndrome, 15 of whom were evaluated after arthroscopic anterior acromioplasty. Isokinetic strength was assessed using the Biodex system in a modified position (in the plane of the scapula and in 45 degrees abduction) with test speeds of 60 degrees and 180 degrees per second. Internal and external rotator strength values and ratios were calculated for both peak torque and average power. Shoulder rotational strength values and the internal rotator/external rotator ratio were significantly higher in the dominant and nondominant control group shoulders than in the involved and uninvolved impingement shoulders for operated on and nonoperated on patients. These data demonstrate that primary change in the normal internal rotator/external rotator ratio of the shoulder is an etiological factor implicated in impingement syndrome not modified by anterior acromioplasty.

Acromion↗

[Results of a series of deltoid flaps for the treatment of massive rotator cuff tears with an average follow-up of 3.5 years].

PURPOSE OF THE STUDY: We report a series of 14 patients with a massive rotator cuff tear operated on with a deltoid flap according to Augereau's technique. The aim of this study was to evaluate the benefits of this technique using Constant's scoring system. The follow up is 40 months. MATERIAL AND METHOD: 14 patients, mean age 59 years, with a total rotator cuff tear type III according to Gerber's classification were included. There was 13 total ruptures of the supra and infra spinatus tendon and one infraspinatus and subscapularis lesion. All the patients had shoulder pain, and the preoperative, Constant's score was 24.1/100. The diagnosis of the rotator cuff rupture was confirmed by X-rays, arthrography and ultra-sonography. 8 patients had a Magnetic Resonance Imaging (MRI) evaluation. The surgical procedure was the technique described by Augereau, and three patients had a resection of the distal clavicle. One patient had a small piece of dacron to reinforce the suture of a very thin deltoid flap. All the patients had a immobilization in abduction and the rehabilitation programm began immediately. RESULTS: Results on pain were good: +11.4 points according to Constant's score, but improvement strength (+0.7 point) or motion (+1 point) was not significative. Postoperative Constant's score was 46.9, ponderated score increased from 29.5 per cent to 57.5 per cent. Ten patients were very satisfied, 2 were satisfied and two were disappointed. One of them neaded shoulder arthrodesis; the other needed a new surgery to remove the piece of dacron, and was allayed with NSAI drugs. External rotation was slightly increased: +2 point. DISCUSSION: These results are similar to others series on pain relief, but the results are poor on strength restauration and on shoulder motion. This technique is a heavy surgical procedure and results are not better than arthroscopic sub acromial decompression for massive rotator cuff tear.

Aged↗

Sonographic signs of complete rotator cuff tears.

BACKGROUND: To evaluate the usefulness of high resolution ultrasound (HRUS) in the examination of complete rotator cuff tear (RCT). METHODS: A prospective study of 157 patients with sonographic examination of shoulder was performed. All of them complained of chronic shoulder pain and were referred by clinician for suspicion of RCT. Their age ranged from 30 to 76 years. The ultrasonic scanners we used were Acuson 128 XP 10 with 7MHz linear transducer, or Diasonics VST master series using 10MHz linear transducer. Examination positions included external rotation of shoulder for scanning biceps tendon and subscapularis tendon, and internal rotation for supraspinatus tendon and lateral scan of infraspinatus tendon and teres minor tendon. Sonographic criteria of complete RCT included 1. complete absence of rotator cuff (RC); 2. focal thinning of RC; 3. focal hypoechoic cleft of RC; 4. focal depression of RC; and 5. heterogeneous hypoechoic RC with subdeltoid bursa fluid. Arthrography was performed after sonography examination on the same day. RESULTS: Among 49 complete RCTs diagnosed by sonography, 46 were proved to be complete RCT by arthrography; only 3 were false positive. In 108 patients with normal rotator cuff diagnosed by sonography, 104 had compatible results with arthrography; only 4 patients turned out to be complete RCT. The sensitivity, specificity, positive predictive values, negative predictive values and accuracy were 92%, 97.2%, 93.9%, 96.3% and 95.5%, respectively. CONCLUSIONS: HRUS can directly demonstrate the morphological changes of RC. It has a high sensitivity and specificity in the diagnosis of complete RCT, and can be used as a firstline screening modality for complete RCT in patients with chronic shoulder pain.

Adolescent↗

Arthroscintigraphy in suspected rotator cuff rupture.

AIM: In order to evaluate the diagnostic efficiency of arthroscintigraphy in suspected rotator cuff ruptures this new imaging procedure was performed 20 times in 17 patients with clinical signs of a rotator cuff lesion. The scintigraphic results were compared with sonography (n = 20), contrast arthrography (n = 20) and arthroscopy (n = 10) of the shoulder joint. METHODS: After performing a standard bone scintigraphy with intravenous application of 300 MBq 99m-Tc-methylene diphosphonate (MDP) for landmarking of the shoulder region arthroscintigraphy was performed after an intraarticular injection of 99m-Tc microcolloid (ALBU-RES 400 MicroCi/5 ml). The application was performed either in direct combination with contrast arthrography (n = 10) or ultrasound conducted mixed with a local anesthetic (n = 10). Findings at arthroscopical surgery (n = 10) were used as the gold standard. RESULTS: In case of complete rotator cuff rupture (n = 5), arthroscintigraphy and radiographic arthrography were identical in 5/5. In one patient with advanced degenerative alterations of the shoulder joint radiographic arthrography incorrectly showed a complete rupture which was not seen by arthroscintigraphy and endoscopy. In 3 patients with incomplete rupture, 2/3 results were consistent. A difference was seen in one patient with a rotator cuff, that has been already revised in the past and that suffered of capsulitis and calcification. CONCLUSION: Arthroscintigraphy is a sensitive technique for detection of rotator cuff ruptures. Because of the lower viscosity of the active compound, small ruptures can be easily detected, offering additional value over radiographic arthrography and ultrasound, especially for evaluation of incomplete cuff ruptures.

Adult↗

Assignment of the absolute configuration of [n]-ladderanes by TD-DFT optical rotation calculations.

In this study, we report theoretical specific rotation values for a series of cis-/trans-alkylated-[5]-ladderanes and cis-/trans-methylated-[n]-ladderanes. Using time-dependent density functional response theory optical rotation calculations, we can assign (+) and (-) optical rotation signs to trans-(S)-alkyl-[5]-ladderane and trans-(R)-alkyl-[5]-ladderane configurations, respectively. In order to qualitatively validate our absolute configuration predictions, we computed optical rotation values at three different levels of theory--B3LYP, RI-BP86, and Hartree-Fock--using the aug-cc-pVDZ basis set. We observe a novel rung-parity-controlled oscillatory optical rotatory phenomenon in our computations, which, to the best of our knowledge, has never been reported or observed before. Furthermore, this preliminary analysis of optical rotation properties in this class of compounds should facilitate the correct absolute stereochemical assignment of natural and synthetic ladderanes, such as the trans-isomer of pentacyclic C(20)-fatty acid methyl ester (pentacycloanammoxic methyl ester), without the need for derivatization, in particular for cases where NMR or X-ray crystal structures are not readily available.

Mathematics↗

Geometry of the projection of the visual field onto the superior colliculus of the wallaby (Macropus eugenii). II. Stability of the projection after prolonged rearing with rotational squint.

At about the time of eye opening, one eye of seven tammar wallaby pouch young was surgically rotated about the optic axis by approximately 90 degrees. In adulthood the projection of the visual field through the rotated eye onto the contralateral superior colliculus was mapped electrophysiologically. Although apparently distorted, the projection could be coherently re-rotated mathematically to a reasonable copy of the normal projection from the opposite eye of the same animal, including details such as regional variations of the magnification factor. The same was true of three adult animals in which the eye rotation was done after anaesthesia immediately before the electrophysiological mapping. In animals in which the visual field seen through one eye, the other being normal, was rotated for the entire period of visual experience, there was no sign of compensation or rearrangement of the topographic map. Retinocollicular synaptic connections appear unmoved by such discordant visual experience.

Animals↗

Computer-based periaxial rotation measurement for aligning fractured femur fragments from CT: a feasibility study.

A new computer-based method for measuring periaxial rotation of healthy and fractured femurs from preoperative CT during closed femoral fracture reduction surgery is described. The method provides a comparative quantitative measure to align the distal and proximal femur fragments based on periaxial rotation. The periaxial rotation is defined in terms of patient-specific bone features. An algorithm for automatically extracting these features from the CT based on this definition has been developed. The algorithm extracts the condyle landmarks and neck axis of the healthy bone, determines its periaxial rotation, and extrapolates this data, assuming mirror symmetry between the healthy and fractured bones, to measure periaxial rotation between the fractured fragments. Unlike existing techniques, the method requires minimal user intervention. In a feasibility study, the method was applied to five dry femurs and one patient data set, and simulated a reduction based on the periaxial measurements with satisfactory results. The experiments showed the measured angle on the fractured femur to be within 1-4.5 degrees of that of the healthy bone.

Algorithms↗

Sonography of the rotator cuff in painful shoulders performed without knowledge of clinical information: results from 58 sonographic examinations with surgical correlation.

PURPOSE: To assess the value of sonography as an isolated diagnostic test for the detection and quantification of rotator cuff tears. METHODS: Preoperative sonographic examination was performed on 58 shoulders. Key biases on sonographic interpretation such as history-taking, physical examination, or concurrent imaging examinations were excluded by way of blinding. Tears of the rotator cuff were the positive findings of interest. Assessment of tear size and localization was done sonographically, and the results were compared with operative findings. RESULTS: All 24 full-thickness tears observed at surgery had been diagnosed correctly via sonography. In 19 of 20 cases with an intact rotator cuff, preoperative sonography was negative. Thirteen of 14 partial-thickness tears were not detected via sonography; 1 was misinterpreted as a full-thickness tear. Location of the tears relative to the rotator cuff tendons was described correctly in 21 of 25 cases. For tear size measurement, the 95% range of agreement was less than +/-1 cm. CONCLUSIONS: Blinded sonographic examination is effective in the detection and quantification of full-thickness tears of the rotator cuff but lacks sensitivity in the detection of partial-thickness tears.

Adolescent↗

Thoracic spine centers of rotation in the sagittal plane.

The purpose of this study was to determine in vitro the centers of rotation of thoracic functional spinal units in the sagittal plane. The center of rotation is a convenient concept and part of a precise method of documenting the kinematics of a joint moving in a plane. Fresh cadaver functional spinal units from the thoracic region were utilized. Six load types were used that produced motions only in the sagittal plane, namely anterior and posterior shear forces, flexion and extension moments, and compression and distraction forces. The resulting motion with three degrees of freedom was measured with dial gauges. Statistical methods were used to analyze data from the viewpoint of vertebral level, load magnitude, and load type. Only the load type was found to be significantly related to the location of the centers of rotation. Although there was significant variability in the centers of rotation, there were definite locations related to each load type. The average center of rotation was 15-45 mm directly below the geometric center of the moving vertebra. The results of the present study may be helpful in the clinical interpretation of spinal kinematic studies.

Adult↗

3,4-Methylenedioxymethamphetamine counteracts akinesia enantioselectively in rat rotational behavior and catalepsy.

We have shown recently that 3,4-methylenedioxymethamphetamine (MDMA) has symptomatic antiparkinsonian activity in rodent models of Parkinson's disease. In search of its mechanism of action, we further investigated the enantiomers of MDMA in the rotational behavioral model and catalepsy test. Catalepsy testing was done in drug-naive unlesioned animals. The parkinsonian symptoms rigor and akinesia (i.e., catalepsy) were induced by intraperitoneal administration of haloperidol 0.5 mg/kg and measured repeatedly as descent latency from a horizontal bar and a vertical grid. MDMA and both its enantiomers were effective in counteracting haloperidol-induced catalepsy, but if given as racemic, the effects were more pronounced than with the enantiomers. For testing of rotational behavior, male Sprague Dawley rats were lesioned unilaterally with 6-hydroxydopamine (6-OHDA) at the medial forebrain bundle. Administration of S-MDMA (5 mg/kg) produced ipsilateral rotations. R-MDMA was far less effective in inducing ipsilateral rotations in 6-OHDA unilaterally lesioned rats, but when S-MDMA was given additionally rotations immediately increased. Regarding their overall antiparkinsonian effects, the S-enantiomer of MDMA was more effective than its R-congener. R-MDMA was able to increase the actions of S-MDMA.

Adrenergic Uptake Inhibitors↗

Rotation of the vermis as a cause of enlarged cisterna magna on prenatal imaging.

OBJECTIVES: Dandy-Walker complex is a continuum of developmental anomalies of the posterior fossa which includes vermian rotation. However, vermian rotation alone may be benign. The aim of this study was to describe our experience with sagittal-plane prenatal ultrasound in the diagnosis of rotation of the vermis in cases of suspected enlarged cisterna magna on routine antenatal imaging, and to describe the follow-up of these patients. METHODS: Seven women, who were referred to our ultrasound unit for evaluation of an enlarged fetal cisterna magna and suspected agenesis of the vermis on axial-plane imaging, underwent further multiplanar studies of the posterior fossa and measurements of the vermis. RESULTS: The mean maternal age was 27 (range, 20-33) years and the mean gestational age at diagnosis was 19.5 (range, 18-31) weeks. The standard axial plane image showed a 'direct communication' between the cisterna magna and the fourth ventricle. In the mid-sagittal plane, the vermis was clearly delineated, with posterosuperior rotation. Vermis size was within normal limits for gestational age in all cases. Findings were confirmed by prenatal magnetic resonance imaging (MRI) in two cases and postnatal MRI and/or sonography in five. During a mean follow-up of 4.5 (range, 1-7.5) years, all children developed normally, with no neurological complications. CONCLUSION: The finding of an enlarged cisterna magna on standard- (axial-)plane ultrasound should be evaluated further in the sagittal plane to determine whether the cause is rotation of a normal vermis. This may spare patients unnecessary tests, anxiety and, in some cases, pregnancy termination.

Adult↗

Effect of acute L-Dopa pretreatment on apomorphine-induced rotational behavior in a rat model of Parkinson's disease.

Currently, reduction of apomorphine-induced rotational behavior in the 6-hydroxydopamine (6-OHDA) lesioned rat is the most utilized drug-induced paradigm for assessing functional efficacy in a rat model of Parkinson's disease (PD). Any clinically predictive animal model of PD should include a positive response to l-dopa, the standard pharmacotherapy for PD. However, the acute interaction between L-dopa and apomorphine has never been studied to determine if L-dopa pretreatment could reduce apomorphine-induced rotational behavior in a 6-OHDA lesioned rat. The present study was designed to explore whether, indeed, pretreatment with subrotational doses of L-dopa could inhibit apomorphine-induced rotations. The data indicate that L-dopa significantly reduced apomorphine-induced rotational behavior only at one dose (5.0 mg/kg) for 12 min. Based on these and other data, it is concluded that although the apomorphine-induced rotational paradigm may continue to be utilized as one additional indicator of efficacy in the 6-OHDA rat model of PD, it is not in itself a completely valid functional assay.

Animals↗

Spontaneous paroxysmal circling behavior in the ci2 rat mutant: epilepsy with rotational seizures or hyperkinetic movement disorder?

Circling, turning, rotating, spinning, wheeling, and cursive hyperkinesia are all synonymous terms used to describe the active movement of an animal in a circular direction. Circling behavior can be evoked by unilateral electrical and chemical stimulation or lesions of various brain sites, but can also occur after systemic drug administration or spontaneously in normal animals or mutant rodents. In humans, stereotypic body rotation can occur as a distinctive entity of generalized and focal epilepsy, and may be due to involvement of the striatum. We have previously described a Lewis rat mutant (ci2) with a behavioral phenotype characterized by lateralized circling, hyperactivity, opisthotonus, and ataxia. In these rats, circling occurs in phases or bursts either spontaneously or in response to stress. Neurochemical data indicate that the circling behavior of the ci2 mutants is related to an abnormal asymmetry in dopaminergic activity in the striatum. Because of the similarities to rotational epilepsy, we used video and electroencephalographic recordings to study whether the rotational behavior of the ci2 mutant rat is a result of a partial or generalized epilepsy. Epileptic WAG/Rij rats were used for comparison. Video monitoring of ci2 rats in the absence of any stress or disturbance showed that circling occurs in paroxysmal bursts during active wakefulness, but not during passive wakefulness or sleep. Circling was not preceded or followed by any convulsive motor seizures and was not associated with epileptiform abnormalities in the electroencephalogram, whereas WAG/Rij rats exhibited myoclonic seizures and epileptic spike-wave discharges during passive wakefulness and sleep. As a result of the association of circling with active wakefulness, ci2 rats exhibited many more rotations during the dark (active) phase compared with the light (rest) period. Increase in active wakefulness during the light phase by transfer of the rats to a new environment induced or intensified circling behavior. Most ci2 rats showed a consistent lateral preference during circling, but some rats changed their preference from one session to another. The data indicate that spontaneous paroxysmal circling behavior in the ci2 rat is not a consequence of epilepsy but reflects a hyperkinetic movement disorder with abnormal lateralization of brain function.

Animals↗

Determination of the chemical shielding tensor orientation from two or one of the three conventional rotations of a single crystal.

Chemical shift anisotropy (CSA) is an immensely useful interaction to study the structure, dynamics, and function of a wide variety of chemical and biological molecules. Traditionally the only unambiguous way to determine both the principal values and the orientation of the principal axes of the CSA tensor has been to follow the chemical shift frequency changes as a crystal of known structure is rotated relative to the direction of the external magnetic field. This classic method employs rotations about three mutually orthogonal axes of a single crystal. It is shown here that just two, or one, of the above rotations suffice to determine the CSA tensor orientation by borrowing, the easy to obtain, principal values of CSA from an independent source. Methods for using two rotation patterns or even a single rotation pattern are described and illustrated with known chemical shielding tensors.

Crystallization↗

Vestibular perception of passive whole-body rotation about horizontal and vertical axes in humans: goal-directed vestibulo-ocular reflex and vestibular memory-contingent saccades.

This study was aimed at complementing the existing knowledge about vestibular perception of self-motion in humans. Both goal-directed vestibulo-ocular reflex and vestibular memory-contingent saccade (VMCS) tasks were used, respectively as concurrent and retrospective magnitude estimators for passive whole-body rotation. Rotations were applied about the earth-vertical and earth-horizontal axes to study the effect of the otolith signal in self-rotation evaluation, and both in yaw and pitch to examine the horizontal and vertical semi-circular canals. Two different magnitudes of constant angular acceleration (50 degrees/s2 and 100 degrees/s2) were used. The main findings were (1) strong correlation between both oculomotor responses of both tasks, (2) greater accuracy with rotations about the earth-vertical than the earth: -horizontal axis, (3) greater accuracy for yaw than for pitch rotations, (4) greater accuracy for high acceleration than for low, and (5) no effect of the delay (2 s or 12 s) in the VMCS task. Adequacy of both tasks as subjective magnitude estimators of vestibular perception of self-motion is discussed.

Adult↗

Common processing constraints for visuomotor and visual mental rotations.

Naive human subjects were tested in three different tasks: (1) a visuomotor mental rotation task, in which the subjects were instructed to move a cursor at a given angle from a stimulus direction; (2) a visual mental rotation task, in which the subjects had to decide whether a displayed letter was normal or mirror image regardless of its orientation in the plane of presentation; and (3) a visuomotor memory scanning task, in which a list of two to five stimuli directions were presented sequentially and then one of the stimuli (test stimulus), except the last one, was presented again. Subjects were instructed to move a cursor in the direction of the stimulus that followed the test stimulus in the previous sequence. The processing rate of each subject in each task was estimated using the linear relation between the response time and the angle (mental rotation tasks) or the list length (memory scanning task). We found that the processing rates in the mental rotation tasks were significantly correlated but that neither correlated significantly with the processing rate in the memory scanning task. These results suggest that visuomotor and visual mental rotations share common processing constraints that cannot be ascribed to general mental processing performances.

Cognition↗

Refine your search to explore more results.