Directional dependence of osteoblastic calcium response to mechanical stimuli.

In adaptive bone remodeling, mechanical signals such as stress/strain caused by loading/deformation are believed to play important roles as regulators of the process in which osteoclastic resorption and osteoblastic formation are coordinated under a local mechanical environment. The mechanism by which cells sense and transduce mechanical signals to the intracellular biochemical signaling cascade is still unclear, however to address this issue, the present study investigated the characteristic response of a single osteoblastic cell, MC3T3-E1, to a well-defined mechanical stimulus and the involvement of the cytoskeletal actin fiber structure in the mechanotransduction pathway. First, by mechanically perturbing to a single cell using a microneedle, a change in the intracellular calcium ion concentration [Ca(2+)](i) was observed as a primal signaling response to a mechanical stimulus, and the threshold value of the perturbation as the mechanical stimulus was evaluated quantitatively. Second, to study directional dependence of the response to the mechanical stimulus, the effect of actin fiber orientation on the threshold value of the calcium response was investigated at various magnitudes and directions of the stimulus. It was found that the osteoblastic response to the perturbation exhibited a directional dependence. That is, the sensitivity of osteoblastic cells to a mechanical stimulus depends on the angle of the applied deformation with respect to the cytoskeletal actin fiber orientation. This finding is phenomenological evidence that cytoskeletal actin fiber structures are involved in the mechanotransduction mechanism, which may be related to cell polarization behaviors such as cellular alignment caused by mechanical stimulation.

Actin Cytoskeleton↗

Assessing micromechanical properties of cells with atomic force microscopy: importance of the contact point.

Mechanical properties are obtainable from atomic force microscopy (AFM) indentation force-depth curves, which are calculated from relationships between tip deflection and cantilever position, i.e. deflection curves. Indentation depth is the difference between tip deflections on a rigid and a soft material for the same amount of cantilever advancement, after contact is made. Since the contact point cannot be unequivocally identified from experimental data, there is some uncertainty in estimating material properties. Using simulations, this study examines some important issues related to the influence of contact point identification on estimated material properties. Simulations for linear materials using a typical stiffness for an AFM cantilever demonstrate that certain portions of the post-contact region of deflection curves for soft and very stiff materials can be approximated by quadratic and linear functions, respectively. Based on these findings, we first develop and verify an objective, automatic method to identify the contact point for materials with linear properties. We then assess the effect of misidentifying the contact point, with and without noise. If the contact point is missed by <50 nm, material properties for small indentations are erroneous but the error decreases asymptotically beyond 200 nm of indentation and the correct estimate of material stiffness is obtained. If the contact point is missed by >100 nm, however, the true material properties cannot be estimated accurately. Noise adds to uncertainty in material properties at small indentations but the combined effect of missing the contact point and noise is dominated by the former. Even though the algorithm was developed for linear materials, it is also suitable for certain nonlinear materials making it more generally applicable.

Algorithms↗

Controlling cell responses to cyclic mechanical stretching.

In most cell culture studies, cells are grown on smooth culture surfaces. Using microfabrication technology, we have developed microgrooved silicone surfaces to grow cells and subject them to repetitive mechanical stretching. When human patellar tendon fibroblasts were plated on these microgrooved surfaces, the cells had an elongated shape and underwent cyclic uniaxial stretching parallel to their long axes, all of which closely mimic conditions of tendon fibroblasts in vivo. Also, when fibroblasts were grown on microgrooves oriented at 45 and 90 degrees with respect to stretching direction, they did not change alignment or shape under cyclic mechanical stretching. Furthermore, compared to nonstretched cells, 8% cyclic stretching of tendon fibroblasts oriented at 0 (i.e., parallel to stretching direction), 45, and 90 degrees was found to increase alpha-SMA protein expression level by 46, 31, and 14%, respectively. In addition, 8% cyclic stretching tendon fibroblasts for 4 and 8 h oriented parallel to stretching direction increased alpha-SMA protein expression level by 25 and 57%, respectively. Thus, the results of this study showed that alpha-SMA protein expression levels of tendon fibroblasts depend on cell orientation with respect to stretching direction and stretching duration. We suggest that microgrooved silicone substrates can be used to study biological responses of tendon or ligament fibroblasts to repetitive mechanical stretching conditions in a more controlled manner.

Cell Culture Techniques↗

Large deformation finite element analysis of micropipette aspiration to determine the mechanical properties of the chondrocyte.

Chondrocytes, the cells in articular cartilage, exhibit solid-like viscoelastic behavior in response to mechanical stress. In modeling the creep response of these cells during micropipette aspiration, previous studies have attributed the viscoelastic behavior of chondrocytes to either intrinsic viscoelasticity of the cytoplasm or to biphasic effects arising from fluid-solid interactions within the cell. However, the mechanisms responsible for the viscoelastic behavior of chondrocytes are not fully understood and may involve one or both of these phenomena. In this study, the micropipette aspiration experiment was modeled using a large strain finite element simulation that incorporated contact boundary conditions. The cell was modeled using finite strain incompressible and compressible elastic models, a two-mode compressible viscoelastic model, or a biphasic elastic or viscoelastic model. Comparison of the model to the experimentally measured response of chondrocytes to a step increase in aspiration pressure showed that a two-mode compressible viscoelastic formulation accurately captured the creep response of chondrocytes during micropipette aspiration. Similarly, a biphasic two-mode viscoelastic analysis could predict all aspects of the cell's creep response to a step aspiration. In contrast, a biphasic elastic formulation was not capable of predicting the complete creep response, suggesting that the creep response of the chondrocytes under micropipette aspiration is predominantly due to intrinsic viscoelastic phenomena and is not due to the biphasic behavior.

Animals↗

Zonal uniformity in mechanical properties of the chondrocyte pericellular matrix: micropipette aspiration of canine chondrons isolated by cartilage homogenization.

The pericellular matrix (PCM) is a region of tissue that surrounds chondrocytes in articular cartilage and together with the enclosed cells is termed the chondron. Previous studies suggest that the mechanical properties of the PCM, relative to those of the chondrocyte and the extracellular matrix (ECM), may significantly influence the stress-strain, physicochemical, and fluid-flow environments of the cell. The aim of this study was to measure the biomechanical properties of the PCM of mechanically isolated chondrons and to test the hypothesis that the Young's modulus of the PCM varies with zone of origin in articular cartilage (surface vs. middle/deep). Chondrons were extracted from articular cartilage of the canine knee using mechanical homogenization, and the elastic properties of the PCM were determined using micropipette aspiration in combination with theoretical models of the chondron as an elastic incompressible half-space, an elastic compressible bilayer, or an elastic compressible shell. The Young's modulus of the PCM was significantly higher than that reported for isolated chondrocytes but over an order of magnitude lower than that of the cartilage ECM. No significant differences were observed in the Young's modulus of the PCM between surface zone (24.0 +/- 8.9 kPa) and middle/deep zone cartilage (23.2 +/- 7.1 kPa). In combination with previous theoretical biomechanical models of the chondron, these findings suggest that the PCM significantly influences the mechanical environment of the chondrocyte in articular cartilage and therefore may play a role in modulating cellular responses to micromechanical factors.

Animals↗

Direct force measurement of the interaction between liposome and the C2A domain of synaptotagmin I using atomic force microscopy.

The binding force between a liposome and the C2A domain of synaptotagmin I was determined by an atomic force microscopy (AFM). Liposomes were immobilized on the surface of the L1 sensor chip and the C2A domains, which recognize phosphatidylserine, were chemically conjugated onto a gold-coated cantilever tip. The average interaction force between the C2A domain and the liposome was 306 (+/-57) pN while the force between untreated cantilever and the liposome was 58 (+/-16) pN. This work helps understand the physicochemical interactions between proteins and lipid vesicles for the design of high affinity protein probes against the apoptotic cell surface.

Binding Sites↗

Two-beam optical traps: refractive index and size measurements of microscale objects.

A counter-propagating optical trap measurement (COTM) system is proposed and analyzed based on the ray-optics model. In this system, refractive index and size of trapped objects can be estimated by using forward scattered light from the two-beam laser trap with resolution Delta n = 0.013 for the refractive index measurements and 3.3% for the size measurements, which is comparable with current bulk techniques, such as refractometry, and flow cytometry. The unique advantage of the COTM system over conventional approaches lies in its capability of marker-free single-particle characterization in whatever transparent buffer required by living cell, eliminating the necessity of changing the fluid composition of the sample in refractometry, and of tagging target with toxic fluorescence dyes in flow cytometry. Noise analysis predicts a potential improvement in the system resolution by more than two orders of magnitude. This non-invasive and sterile tool complements lab-on-a-chips with single cell manipulation and analysis in living friendly ambient.

Biopolymers↗

Micropatterned structures for studying the mechanics of biological polymers.

Studying the mechanics of nanometer-scale biomolecules presents many challenges; these include maintaining light microscopy image quality and avoiding interference with the laser used for mechanical manipulation, that is, optical tweezers. Studying the pushing forces of a polymerizing filament requires barriers that meet these requirements and that can impede and restrain nanoscale structures subject to rapid thermal movements. We present a flexible technique that meets these criteria, allowing complex barrier geometries with undercut sidewall profiles to be produced on #1 cover glass for the purpose of obstructing and constraining polymerizing filaments, particularly microtubules. Using a two-layer lithographic process we are able to separate the construction of the primary features from the construction of a depth and shape-controlled undercut. The process can also be extended to create a large uniform gap between an SU-8 photoresist layer and the glass substrate. This technique can be easily scaled to produce large quantities of shelf-stable, reusable microstructures that are generally applicable to microscale studies of the interaction of cellular structures with defined microscale features.

Biomechanical Phenomena↗

External force-assisted cell positioning inside microfluidic devices.

This paper describes straightforward approaches to positioning cells within microfluidic devices that can be implemented without special equipment or fabrication steps. External forces can effectively transport and position cells in preferred locations inside microfluidic channels. Except for centrifugal force-based positioning that can be used with any microfluidic channels, hydrodynamic and gravitational force-based positioning yield reproducible and biocompatible results when implemented with a microfluidic "module" that contains a barrier with embedded microgrooves. Primary rat cortical neurons, metastatic human breast cancer cells MDA-MB-231, NIH 3T3 mouse fibroblasts, and human umbilical vein endothelial cells (HUVECs) were compatible with the positioning processes. After positioning, cells attached, proliferated and migrated like control cells that were cultured on tissue culture dishes or glass coverslips. No apparent morphological differences were observed in positioned cells compared with control cells. Finally, to demonstrate a practical application of the methods, cells were placed in a single row along a wall inside a microfluidic chemotaxis chamber (MCC), and were exposed to stable concentration gradient of chemoattractant. Cell positioning allows that all cells get exposed to the same level of chemoattractant at the start of the experiment helping standardize cellular response.

Animals↗

Transport of living cells with magnetically assembled nanowires.

We present a technique of transporting and positioning living cells internalized by nickel (Ni) nanowires guided by magnetic field. Nanoscale magnetic nanowires are internalized by the Rat Neuroblastoma (ATCC number CRL-2754) and the cells are transported and positioned by magnetic fields from the magnetic material-coated electrodes. This technique may enable the interfacing between neurons and electronic devices to empower investigations pertaining to non-invasive neuron probing as well as nanofabricated neural pharmacological technologies.

Animals↗

Recognition and capture of breast cancer cells using an antibody-based platform in a microelectromechanical systems device.

Cancer is one of the most common diseases afflicting humans. The use of biomarkers specific for tumor cells has facilitated their identification. However, technology has not kept pace with the field of molecular biomarkers, leaving their potential unrealized. Here, we demonstrate the efficacy of recognizing and capturing cancer cells using an antibody-based, on-chip, microfluidic device. A cancer cell capture biochip consisting of microchannels of size 2.0 cm long and 500 microm wide and deep, was etched onto Polydimethylsiloxane. Epithelial membrane antigen (EMA) and Epithelial growth factor receptor (EGFR) were coated on the inner surface of the microchannels. The overall chip measured 2.0 cm x 1.5 cm x 0.5 cm. Normal and tumor breast cells in a phosphate buffered saline (PBS) suspension were flowed through the biochip channels at a rate of 15 microL/min. Breast cancer cells were preferentially captured and identified while most of normal cells passed through. The capture rates for tumor and normal cells were found to be >30% and <5%, respectively. This preliminary cancer cell capture biochip design supports our initial effort of moving a BioMEMS device, from the bench top to the clinic.

Animals↗

Modeling, design and validation of a novel microfluidic sensor for in-vitro isotonic measurement of microvessel contraction/dilation.

The paper presents an innovative fluidic microdevice for in-vitro isotonic measurements of microvessel contraction/dilation. The proposed microdevice is based on the well-known fluid dynamic principle which correlates a geometrical change of a solid body immersed in a constant flow, with the differential pressure change induced in the flow itself. Indeed, a biochemically-induced change of microvessel diameter lead to a change of its hydraulic resistance which can be in-vitro measured by a differential pressure sensor. The novel microfluidic sensor has been modeled, designed and fabricated in order to properly implement this working principle. The fluidic scheme of the sensor consists of two pressure-sensorized chambers which are connected by a calibrated channel where the microvessel is placed. Experimental tests have been performed by using three microvessel passive simulators with different inner diameter (300, 600 and 800 microm), in order to validate the expected sensor functioning characterized by two sensitivities: the pressure drop S (PL) and the overall S 2-3 ones. Their measured values (S (PL,m)=2.132 mV/V/Pa, S (2-3,m)=0.787 mV/V/(mm3/s)/mm) confirm the validity of the proposed working principle and permit to be confident in a future application of the sensor in a clinical context.

Blood Flow Velocity↗

A microfluidic platform for 3-dimensional cell culture and cell-based assays.

This paper reports a novel microfluidic platform introducing peptide hydrogel to make biocompatible microenvironment as well as realizing in situ cell-based assays. Collagen composite, OPLA and Puramatrix scaffolds are compared to select good environment for human hepatocellular carcinoma cells (HepG2) by albumin measurement. The selected biocompatible self-assembling peptide hydrogel, Puramatrix, is hydrodynamically focused in the middle of main channel of a microfluidic device, and at the same time the cells are 3-dimensionally immobilized and encapsulated without any additional surface treatment. HepG2 cells have been 3-dimensionally cultured in a poly(dimethylsiloxane) (PDMS) microfluidic device for 4 days. The cells cultured in micro peptide scaffold are compared with those cultured by conventional petri dish in morphology and the rate of albumin secretion. By injection of different reagents into either side of the peptide scaffold, the microfluidic device also forms a linear concentration gradient profile across the peptide scaffold due to molecular diffusion. Based on this characteristic, toxicity tests are performed by Triton X-100. As the higher toxicant concentration gradient forms, the wider dead zone of cells in the peptide scaffold represents. This microfluidic platform facilitates in vivo-like 3-dimensional microenvironment, and have a potential for the applications of reliable cell-based screening and assays including cytotoxicity test, real-time cell viability monitoring, and continuous dose-response assay.

Animals↗

Microtubule transport, concentration and alignment in enclosed microfluidic channels.

The kinesin-microtubule system has emerged as a versatile model system for biologically-derived microscale transport. While kinesin motors in cells transport cargo along static microtubule tracks, for in vitro transport applications it is preferable to invert the system and transport cargo-functionalized microtubules along immobilized kinesin motors. However, for efficient cargo transport and to enable this novel transport system to be interfaced with traditional microfluidics, it is important to fabricate enclosed microchannels that are compatible with kinesin motors and microtubules, that enable fluorescence imaging of microtubule movement, and that provide fluidic connections for sample introduction. Here we construct a three-tier hierarchical system of microfluidic channels that links microscale transport channels to macroscopic fluid connections. Shallow microchannels (5 microm wide and 1 microm deep) are etched in a glass substrate and bonded to a cover glass using PMMA as an adhesive, while intermediate channels (approximately 100 microm wide) serve as reservoirs and connect to 250 microm deep microchannels that hold fine gauge tubing for fluid injection. To demonstrate the utility of this device, we first show the performance of a directional rectifier that redirects 96% of moving microtubules and, because any microtubules that detach rapidly rebind to the motor-coated surface, suffers no microtubule loss over time. Second, we develop an approach, using a headless kinesin construct, to eliminate gradients in motor adsorption and microtubule binding in the enclosed channels, which enables precise control of kinesin density in the microchannels. Finally, we show that a 60 microm diameter circular ring functionalized with motors concentrates and aligns bundles of approximately 3000 uniformly oriented microtubules, while suffering negligible ATP depletion. These aligned isopolar microtubules are an important tool for microscale transport applications and can be employed as a model in vitro system for studying kinesin-driven microtubule organization in cells.

Equipment Design↗

A uniaxial bioMEMS device for quantitative force-displacement measurements.

There is a need for experimental techniques that allow the simultaneous imaging of cellular cystoskeletal components with quantitative force measurements on single cells. A bioMEMS device has been developed for the application of strain to a single cell while simultaneously quantifying its force response. The prototype device presented here allows the mechanical study of a single, adherent cell in vitro. The device works in a fashion similar to a displacement-controlled uniaxial tensile machine. The device is calibrated using an AFM cantilever and shows excellent agreement with the calculated spring constant. The device is demonstrated on a single fibroblast. The force response of the cell is seen to be linear until the onset of de-adhesion with the de-adhesion from the cell platform occurring at a force of approximately 1500 nN.

Animals↗

Leukocyte-endothelium interaction: measurement by laser tweezers force spectroscopy.

Leukocyte adhesion to vascular endothelium is an initial step of many inflammatory diseases. Although the atomic force microscopy (AFM) measurements of leukocyte-endothelial interaction have been recently introduced. with cell adhesion force unbinding curves (CAFUC). We obtained pico-Newton force in the initial interaction between a single living THP-1 cell and HUVEC monolayer using a custom-built laser tweezers (LT) system. The measured quantities included the non-linear force-distance relationship, and the effect of yielding in cell detachment. It is possible to introduce a time scale into the LT cell-detachment experiments for further exploration and more detailed information on the viscoelastic properties of living cells.

Adhesiveness↗

Preembryo biopsy and analysis of blastomeres by in situ hybridization.

We developed a method for the biopsy of preimplantation mouse embryos (preembryos) at the four- to eight-cell stage, which uses partial zona pellucida dissection. The preembryos were collected in calcium- and magnesium-free phosphate-buffered saline solution with 0.01% ethylenediaminetetraacetic acid, 0.1 mol/L sucrose, and 4 mg/ml of bovine serum albumin to facilitate removal of blastomeres. This allows entry of a fine micropipette into the perivitelline cavity with subsequent removal of a single blastomere by gentle suction. The majority of embryos (75%) from which biopsy specimens were obtained in this fashion developed to the blastocyst stage. The blastomeres obtained were mainly intact and they were fixed to glass slides. After permeabilization, in situ hybridization was performed with chromosome X- and chromosome 3-specific probes. Human unfertilized eggs and blastomeres from human polyspermic embryos also have been analyzed by in situ hybridization with chromosome specific probes. The combination of nondestructive embryo biopsy and in situ hybridization is a possible approach for preimplantation genetic diagnosis.

Animals↗

Refine your search to explore more results.