Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Internal Fixators”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

[LISS--internal plate fixator].

The LISS DF (less invasive stabilisation system) is a new internal fixator for the operative treatment of distal femur fractures following the principles of minimally invasive surgery. The fixation of the implant is based on screws providing angular stability, which are inserted percutaneously guided by an aiming device. A large exposure of the fracture zone is not necessary. Between December 1996 and November 1998 a multicentre study were defined including finally 112 patients with 116 distal femur fractures treated with a LISS system. A follow up rate of 93% could be achieved, showing a fractures consolidation in 96% of all cases after 12 months. The results of the study showed a low rate of secondary bone grafting. The LISS system is a secure device for the treatment of all distal femur fractures including complex articular fractures types.

Adult↗

Internal plate fixation of fractures: short history and recent developments.

Metal plates for internal fixation of fractures have been used for more than 100 years. Although initial shortcomings such as corrosion and insufficient strength have been overcome, more recent designs have not solved all problems. Further research is needed to develop a plate that accelerates fracture healing while not interfering with bone physiology. The introduction of rigid plates had by far the greatest impact on plate fixation of fractures. However, it led to cortical porosis, delayed bridging, and refractures after plate removal. These unwarranted effects were said to be caused by bone-plate contact interfering with cortical perfusion. Consequently, further plate modifications aimed to reduce this contact area to minimize necrosis and subsequent porosis. The advocates of limited-contact plates have not published measurements of the contact area or proof of the temporary nature of the porosis. Moreover, clinical studies of newer plate types have failed to show a superior outcome. Histomor-phometric measurements of the cortex showed no difference in the extent of necrosis under plates having different contact areas. Necrosis was predominant in the periosteal cortical half, whereas porosis occurred mostly in the endosteal cortical half. No positive correlation was found between either. The scientific evidence to date strongly suggests that bone loss is caused by stress shielding and not interference with cortical perfusion secondary to bone-plate contact. Consequently, an axially compressible plate (ACP) incorporating polylactide (PLA) inserts press-fit around screw holes was designed. The bioresorbable inserts should allow for (1) increased micromotion in the axial plane to promote healing during the union phase and (2) gradual degradation over time to decrease stress shielding during the remodeling phase. Results of ongoing experimental results are encouraging. Only plates allowing dynamic compression in the axial plane can lead to a revolution in fracture fixation.

Animals↗

Recombinant human osteogenic protein-1 induces bone formation in a chronically infected, internally stabilized segmental defect in the rat femur.

BACKGROUND: Recombinant human osteogenic protein-1 (rhOP-1), combined with a collagen carrier, has been shown to induce new-bone formation in a variety of animal models. The purpose of the present investigation was to test the hypotheses that rhOP-1 would accelerate bone formation in an internally stabilized, chronically infected, critical-size defect in the rat femur and that this effect would be enhanced by the administration of systemic antibiotic. METHODS: A 6-mm segmental defect was created surgically, stabilized with a polyacetyl plate and six Kirschner wires, and contaminated with 10(4) colony-forming units of Staphylococcus aureus in one femur in each of 168 Sprague-Dawley rats. After two weeks, these infected defects were débrided surgically and were assigned to one of six treatment groups. The defects in the thirty animals in the first group received lyophilized collagen carrier mixed with 200 microg of rhOP-1 dissolved in buffer, the defects in the thirty animals in the second group received carrier with 20 microg of rhOP-1 in buffer, and the defects in the twenty-four control animals in the third group received carrier mixed with buffer without rhOP-1. The last three groups were treated identically to the first three groups, except that the animals also received the antibiotic ceftriaxone for twenty-eight days after débridement. The animals were killed at two, four, eight, or twelve weeks after débridement. Newly mineralized callus within the defect, and adjacent to and bridging the outside of the defect, was assessed with use of quantitative high-resolution radiography, microcomputed tomography, torsional failure testing, and histological analysis of undecalcified sections. RESULTS: Bacterial cultures confirmed the presence of a chronic infection during the study period in all animals. At the later time-points, significantly more newly mineralized callus was present within and adjacent to the débrided defects that had been treated with 200 microg of rhOP-1, whereas minimal amounts of callus were present within and adjacent to the defects that had been treated without rhOP-1 and with 20 microg of rhOP-1. At eight and twelve weeks after débridement, there was significantly more newly mineralized callus in the group that had been treated with 200 microg of rhOP-1 with antibiotic than in the group that had been treated with 200 microg of rhOP-1 without antibiotic (p < 0.05). At twelve weeks, the values for torque, energy to failure, and linear stiffness for femora that had been treated with 200 microg of rhOP-1 with antibiotic were not significantly different from the values for intact, contralateral control femora, whereas the values for femora that had been treated with 200 microg of rhOP-1 without antibiotic remained significantly lower than those for the intact, contralateral controls (p < 0.05). CONCLUSIONS: Recombinant human osteogenic protein-1 maintained its osteoinductive capability in the presence of chronic infection, and this property was enhanced by antibiotic therapy. No substantial callus formed in the infected defects without a sufficiently high dose of rhOP-1. CLINICAL RELEVANCE: The treatment of an infection at the site of a fracture often necessitates removal of internal fixation. However, internal fixation is needed for fracture stability. This study presents an intervention that may accelerate fracture-healing in the presence of infection and colonized hardware, thereby permitting earlier removal of the hardware and more timely and effective treatment of the infection.

Animals↗

[Anatomical restoration of thoracolumbar spine with burst fracture].

A burst fracture was created in the L1 vertebra of six fresh human cadaver spines and reduction was performed using AO fixator intern, reduction fixation (RF) device, and Steffee plate instrumentation systems to determine the reduction force (distraction vs distraction plus lordosis) contributing to the anatomical restoration of thoracolumbar spine. These three pedicular screw devices were applied to the specimens following the use of standard clinical technique for each device. The AO fixator intern and the RF device provided independent control of distraction and lordosis correction. The Steffee device maintained a set distraction and lordosis. The RF device provided pre-set fixed incremental lordosis, while the AO provided variable angular correction. Plain X-rays and CT scans were taken of the specimens before and after creation of the fracture and following application of each device. Results demonstrated that the symmetric lordotic distraction of the disc space and vertebral body provided by the RF device achieved the best possible reduction of the intracanal fragment and sagittal alignment.

Adult↗

Intra-articular fractures of the distal aspect of the radius.

Intra-articular distal radius fractures are a heterogeneous group of injuries with different fracture patterns. The existing classification systems are helpful for describing the fractures but not for assessing their stability or for deciding which surgical approach to use. Patients who have a fracture with at least 1.0 mm of displacement of the articular surface may benefit from open surgical treatment. Improved diagnostic imaging with CT is helpful for fracture classification and surgical planning. The options for surgical treatment include limited open reduction and internal fixation, arthroscopically assisted internal fixation, and open reduction and internal fixation. The surgical approach is determined on the basis of the initial displacement of the fracture. Patients who have a displaced fracture of the volar rim may benefit from a volar approach; those who have a dorsally displaced fracture, from a dorsal approach; and those who have an impacted fracture such as a die-punch fracture, from a dorsal approach that provides better visualization of the articular surface. The long-term functional outcome is determined in part by the severity of the fracture as defined by the amount of comminution, the initial severity of displacement, and the number of fracture fragments. The accuracy of the reconstruction of the articular surface, with the goal of establishing congruency to within 1.0 mm, is also important in order to minimize the risk of late osteoarthrosis. Of all of the extra-articular parameters, restoration of the length of the radius is the most important for enhancing recovery of motion and grip strength and for preventing problems involving the distal radioulnar joint--the so-called forgotten joint in distal radial fractures.

Arthroscopy↗

Clamping stiffness and its influence on load distribution between paired internal spinal fixation devices.

The load distribution between two internal spinal fixation devices depends, besides other factors, on their stiffness. The stiffness ranges were determined experimentally for the clamps of the AO internal fixator with lateral nut and with posterior nut as well as for the clamps of the SOCON fixator. The stiffness of eight devices each differed by a factor of 3.1 for the clamp with lateral nut, by a factor of 1.5 for the clamp with posterior nut, and by a factor of 1.4 for the clamp of the SOCON fixator. For the AO clamp with lateral nut, the influence of the nut-tightening torque on the stiffness was determined. Using instrumented internal spinal fixation devices mounted to plastic vertebrae and simulating a corpectomy, the load distribution between the implants was measured for different tightening torques. It could be shown that, for the AO internal fixator whose clamps have a lateral nut, a nut-tightening torque > 5 Nm has only a negligible influence on load-sharing between the implants. Tooth damage occurs when the teeth of the clamp body and clamping jaw of the clamp with lateral nut do not gear together exactly, which leads to changes in the clamping stiffness and load-sharing between the two implants.

Humans↗

Early internal fracture fixation prevents bacterial translocation.

The aim of our study was to determine whether early internal fixation of major bone fractures helps prevent bacterial translocation in patients with multitrauma. Thirty-seven Sprague-Dawley rats were divided into three groups: (1) anesthesia only (n = 12); (2) the trauma group: tibia and femur fractures and moderate head trauma under anesthesia (n = 14); and (3) the fixation group: fixation of tibia and femur fractures and moderate head trauma under anesthesia (n = 11). After 24 hours, mesenteric lymph nodes, liver, spleen, and systemic blood samples were quantitatively cultured. The terminal ileum was assessed histopathologically. The incidence of bacterial translocation was less in the anesthesia group (two of 12 rats) and the fixation group (two of 11 rats) than in the trauma group (10 of 14 rats). The number of organs containing viable bacteria was significantly lower in the fixation group than in the trauma group. Histopathologically, villous architecture was preserved mostly in the fixation group; however, marked mucosal damage was detected in the trauma group. Our data suggest early internal fixation of long bone fractures in polytraumatized experimental animals with head injury results in preservation of the intestinal mucosal barrier and decreased bacterial translocation from the gut.

Animals↗

Functional outcome of tibial plateau fractures treated with the fine-wire fixator.

OBJECTIVE: To review the functional outcome of patients with complex tibial plateau fractures treated with fine-wire fixation. DESIGN: Retrospective review with follow-up of patients in outpatient clinic. SETTING: Tertiary trauma center. PATIENTS: All patients who had fine-wire fixation for tibial plateau fractures between 1996 and January 2001 were reviewed. INTERVENTIONS: Fine-wire fixation with/without limited internal fixation for complex tibial plateau fractures. MAIN OUTCOME MEASURES: Knee range of motion, adequacy of articular surface reduction, mechanical axis, Knee Society Clinical Rating Scale and Short-Form 36 Health Questionnaire. RESULTS: Eighteen of twenty-one eligible patients were available for follow-up. There were 14 Shatzker VI and 4 V fractures. Seven fractures were open. Average follow-up was 28.2 months. All fractures united. There were three cases of delayed union, all progressed to union following additional procedures and bone grafting. There were no cases of osteomyelitis, septic arthritis or deep vein thrombosis. Seven patients had Knee Society Clinical Rating Scores of good/excellent (38.9%), and 11 had fair/poor scores (61.1%). Abnormal mechanical axes and multiple co-morbid injuries were associated with poorer outcomes. Although SF-36 scores were lower in the study group compared to matched population norms, 15 of 18 patients had full or partial return to pre-injury levels of functioning. CONCLUSION: Fine-wire fixation with limited internal fixation is a satisfactory method of managing complex high-energy fractures of the tibial plateau where soft tissue injury and bony comminution make traditional techniques of open reduction and internal fixation unsuitable.

Adult↗

Distal radioulnar joint function after Galeazzi fracture-dislocations treated by open reduction and internal plate fixation.

Nineteen Galeazzi fracture-dislocations were reviewed clinically and roentgenographically at an average of 83 months after open reduction and internal fixation. Radiographic observation of fracture reduction was correlated with clinical results. Patients with anatomic fracture reduction had minimal sequelae and better or equal functional results than patients with imperfect reduction. Manual laborers had no weakness, but nonmanual laborers showed significant deficits in supination strength. Concomitant fractures of the wrist, the hand, or both were associated with significant pronation weakness. The volar approach was associated with a significant deficit of flexion/extension range of motion (ROM). Attention was focused on distal radioulnar joint (DRUJ) function and pain. Distal radioulnar joint function was fully restored by open reduction and internal fixation of the radius and indirect anatomic reduction and functional aftercare of the DRUJ in 16 cases. Open revision, repair of the triangular fibrocartilage complex (TFCC), and immobilization of the wrist are not necessary if anatomic reduction of the joint is obtained by indirect means such as open reduction and internal fixation of the radius.

Adult↗

Use of a vertical transarticular pin for stabilization of severe ankle fractures.

Transarticular pin fixation has been used successfully to stabilize severe ankle fractures. This technique is most commonly used as provisional fixation until internal fixation is appropriate. In addition, transarticular pin fixation can be a supplement in cases involving persistent tibiotalar instability after internal fixation and can provide sole definitive fixation of arthritic and osteoporotic ankles. In this article, we describe the surgical technique, report results, and review when transarticular pin fixation may be appropriate. We believe that all orthopedic surgeons should know this technique--especially those treating cases of complex orthopedic trauma.

Adolescent↗

Fractures of the distal femur.

The results of treatment of 47 supracondylar and intracondylar fractures of the femur treated at the Massachusetts General Hospital were examined using a new classification system. Patients with supracondylar fractures without intracondylar extension obtained better knee motion when treated with traction followed by a cast-brace then when treated with internal fixation. Patients with internal fixation. Patients with intracondylar fractures obtained better knee motion when treated with internal fixation. Traction followed by a long-leg cast should not be used for any of these fractures. Younger patients gained greater knee motion than older patients.

Adolescent↗

A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures.

PURPOSE: External fixation and open reduction and internal fixation have been the traditional techniques for surgical fixation of unstable distal radius fractures. The existing literature has not identified which is superior, primarily because of the lack of comparative trials. We performed a comprehensive systematic review and meta-analysis of the current literature on external fixation and internal fixation of distal radius fractures to determine the dominant strategy based on available scientific evidence. METHODS: We searched MEDLINE and EMBASE for English-language articles published between 1980 and 2004 that satisfied predetermined inclusion and exclusion criteria. The outcomes of internal and external fixation were compared using continuous measures of grip strength, wrist range of motion, and radiographic alignment and categoric measures of pain, physician-rated outcome scales, and complication rates. Outcomes were pooled by random-effects meta-analysis and meta-regression analysis was used to control for patient age, presence of intra-articular fracture, duration of follow-up period, and date of publication. Sensitivity analyses were used to test the stability of the meta-analysis results under different assumptions. RESULTS: Forty-six articles were included in the review with 28 (917 patients) external fixation studies and 18 (603 patients) internal fixation studies. Meta-analysis did not detect clinically or statistically significant differences in pooled grip strength, wrist range of motion, radiographic alignment, pain, and physician-rated outcomes between the 2 treatment arms. There were higher rates of infection, hardware failure, and neuritis with external fixation and higher rates of tendon complications and early hardware removal with internal fixation. Considerable heterogeneity was present in all studies and adversely affected the precision of the meta-analysis. CONCLUSIONS: The current literature offers no evidence to support the use of internal fixation over external fixation for unstable distal radius fractures. Comparative trials using appropriately sensitive and validated outcome measurements are needed to guide treatment decisions.

Bone Plates↗

Tibial pilon fractures: a comparative clinical study of management techniques and results.

Thirty-eight consecutive pilon fractures were reviewed retrospectively to compare the radiographic and clinical results with the original injuries based on three different treatment options: external fixation only, external fixation with limited internal fixation, and internal fixation only. Dates of injury were from February 1985 to February 1989. Treatment method was the surgeon's preference. The mean follow-up time was 28 months. Results were tabulated by clinical and radiographic scores. In general, simple fracture types had good results; complex ones did less well. In this study, fracture severity appeared to be the key variable in outcome.

Adolescent↗

Refine your search to explore more results.