At least 1,801 records · Page 100Linked to original sources

Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail.

OBJECTIVES: To compare the results between a new intramedullary Gamma nail and a compression hip screw in the treatment of trochanteric fractures. DESIGN: Prospective randomized. SETTING: Level 1 trauma center. PATIENTS: Two hundred ten consecutive patients older than 65 years with trochanteric femoral fractures. INTERVENTIONS: Treatment with a compression hip screw or a new design of the Trochanteric Gamma nail (180 mm in length with a mediolateral angle of 4 degrees and available only with a proximal diameter of 17 mm and distal diameter of 11 mm). MAIN OUTCOME MEASUREMENTS: Operative and fluoroscopy times, blood loss, functional outcome, complication rate, and failure of fixation. RESULTS: The Trochanteric Gamma nail was used in 104 patients and the compression hip screw in 106. The 2 groups were similar in terms of their preoperative data, with a median follow-up of 13.6 months (range 12-30). The results show no difference in operating time (P = 0.21), but the Trochanteric Gamma nail group had a significantly shorter fluoroscopy time (P = 0.006), and the number of patients transfused and the mean of units of blood transfused were significantly less in the Trochanteric Gamma nail group (P = 0.013, 0.046, respectively). Mortality within 12 months was similar in both groups (P = 0.83). All fractures were radiographically healed at the last visit. There was no difference in intraoperative and postoperative complications or rate of fixation failure between the 2 groups, and no case of secondary shaft fracture of the femur was encountered in this study. In the entire series, there was no difference in the functional outcome (P = 0.74), but the postoperative walking ability was better in those patients with unstable fractures who were treated with the Trochanteric Gamma nail (P = 0.017). CONCLUSIONS: The new Trochanteric Gamma nail is an effective method for the treatment of trochanteric femoral fractures in elderly patients. The indication for either Trochanteric Gamma nail or compression hip screw is similar in stable fractures, but we recommend the use of the Trochanteric Gamma nail for unstable trochanteric fractures.

Aged↗

Internal fixation of forearm diaphyseal fractures: double plating versus single compression (tension band) plating--a comparative study.

Eighty-four fresh diaphyseal fractures of the forearm in 55 patients were treated by double plates, with bone union occurring in 97.6 per cent. Seventy fresh diaphyseal fractures of the forearm in 48 patients were treated by single compression plates (tension band plates) with bone union occurring in 100 per cent. In both series, other than infection (two in the double plating series and none in the compression plating series), the major complication was synostosis. This matter is being further investigated at this time by one of the authors (JWM) in an attempt to abort this most distressing complication. The other major complication is related to the stress riser effect of the implant, particularly after hardware removal. There still remains some difference of opinion as to whether metal has to be removed, and in general, unless there is a clear-cut indication for its removal, we do not do so. We now believe that double plating and single compression plating (tension band plating) will insure a high rate of union, a generally excellent functional result, and a low complication rate. However, ASIF (AO) plating provides a somewhat shorter operative time and, at least theoretically, less stress protection of bone and possibly less devitalization of tissue because of the need for less soft tissue stripping for exposure. Therefore, in our clinic for the most part we now use single tension band plating for displaced diaphyseal fractures of the forearm in the adult.

Adolescent↗

The place of the dynamic compression plate in femoral shaft fractures.

A retrospective study of 32 adult patients with fractures of the femoral shaft treated with the AO dynamic compression plate in one centre was carried out. Pathological fractures, transverse and short oblique fractures in the middle third of the femur were excluded from this study. The average follow-up was 3.5 years. The complications were failure of the implant in 6.3 per cent of cases, loosened screws in 3 per cent, refracture in 3 per cent and non-union in 3 per cent. No instance of deep infection was encountered. The average time taken for union was 5.5 months. The overall objective assessment showed excellent or good results in 90.6 per cent of cases. There is a definite place for the AO dynamic compression plate in well-selected cases of fracture of the femoral shaft, provided that close attention to technical details is observed. Timing of the operation and the postoperative care also affect the results.

Adolescent↗

Treatment of subtrochanteric fractures with a high-angle compression hip screw.

In a series of 25 subtrochanteric fractures transfixed with high-angle compression hip screws, there were no mechanical failures, delayed unions, or nonunions. Osseous union occurred in a mean time of 3.6 months. Malunion occurred in two instances, at least one of which was the result of technical error at the time of reduction. Rapid mobilization of patients with subtrochanteric fractures is an attainable goal. Early partial weight-bearing should be possible. Although no one internal fixation appliance may be optimal for all fractures in the subtrochanteric region, the high-angle compression hip screw is efficient for the fixation of a wide variety of fracture patterns that otherwise would have been difficult to manage.

Adult↗

[Clinico-x-ray-electrophysiologic evaluation of the sequelae of vertebrospinal injuries].

The authors present the data of clinical, x-ray and electrophysiological examinations of 184 patients who suffered vertebrospinal trauma of varying severity. Indicate pronounced disturbances of the function of the neuromuscular apparatus at varying times after the trauma in patients with neglected fractures and dislocation fractures of the vertebrae and with compression-comminuted fractures. They also describe the time course of clinical, x-ray and electrophysiological changes at varying levels of injury to the vertebrae and spinal cord. It is suggested that the clinical, x-ray and electrophysiological data obtained promote the documentation of the indications for application of individual comprehensive rehabilitation therapy with due regard for the level and severity of injuries to the spinal cord and evaluation of the role of the vascular component in the development of the neurological picture.

Adult↗

Compression-plate fixation of acute fractures of the diaphyses of the radius and ulna.

A retrospective study was done of eighty-seven patients who had 129 diaphyseal fractures of either the radius or the ulna, or both, and who were treated with fixation using an AO dynamic-compression plate. Open fractures were internally fixed primarily, and both comminuted and open fractures routinely had bone-grafting. Ninety-eight per cent of the fractures united, and 92 per cent of the patients achieved an excellent or satisfactory functional result. The rate of infection was 2.3 per cent. Refracture occurred after removal of a 4.5-millimeter dynamic-compression plate in two patients, but there were no refractures after removal of a 3.5-millimeter plate. The 3.5-millimeter-plate system gave excellent results in patients who had a fracture of the forearm, and it minimized the risk of refracture. Our results demonstrated that immediate plate fixation of an open fracture of the forearm, with a low rate of complications, is possible.

Acute Disease↗

[Results of treating forearm bone shaft fractures with a 3.5 mm self compressive plate].

Results of 29 forearm bones shaft fracture treatment with 3.5mm self compressive plate in 26 patients aged 18-64 (mean 33) are presented. Open reduction with 3.5mm self compressive plate fixation has been performed in all cases. Anderson et al criteria were used to assess functional and radiological outcome. Excellent and good functional results were achieved in 25 cases, one was rated fair, no poor results were observed.

Adult↗

Ender rod versus compression screw fixation of hip fractures.

Eighty-seven matched pairs of patients with extracapsular hip fractures were treated with either Ender rod or compression screw and plate fixation. The data obtained both perioperatively and from one to 39 months postoperatively showed no significant differences with respect to infection rate, mortality, length of stay, or ultimate functional status. In the Ender rod group, 66.7% of the patients experienced technical problems, compared with 10.3% of patients in the compression screw group. The Ender technique offered few practical advantages and an unacceptably high level of problems, even when patients with only stable fractures were considered.

Adult↗

[Global exposure of the lower extremity of the radius by extended external approach].

With classical lateral access to the lower radius, only the styloid process is correctly exposed and many surgeons prefer elective anterior routes, or more rarely posterior access. Our experience with posterior compression-extension fractures of the lower radius using a posterior plate has led us to describe the modalities of progression to the bone without injury to the tendons and vasculo-nervous bundles. The technique described scrupulously avoids injury and also allows safe iterative access. Finally, and most importantly, this technique also exposes all the aspects of the bone. It can be successfully used for internal fixation in difficult cases and also for the treatment of former acquired or congenital deformations of the epiphysis. This route has been shown to be safe and successful in a prospective series of 187 applications of posterior plates for compression-extension fractures.

Bone Plates↗

[The "biological" plate osteosynthesis in multi-fragment fractures of the para-articular femur. A prospective study].

In a prospective study, 24 fractures of the femur were treated by indirect reduction and internal fixation with a condylar plate or a condylar buttress plate. The inclusion criterion was that each patients's fracture(s) should be amenable to indirect reduction. The goal of the study was to determine the value of biological plating techniques incorporating the use of the distractor and the articulating tension device for indirect reduction, bridging of the fracture zone without dissection of the medial cortex, and calculated instability through undetermined axial compression. Most fractures were comminuted (5 type A, 10 type B and 9 type C according to the AO classification); 14 fractures were subtrochanteric, 8 fractures were supra-/intracondylar and 2 were diaphyseal in nature. The average age of the 14 mean and 10 women was 46 years (16-96). In 4 cases the fracture was open; 8 patients had multiple trauma and 6 had further ipsilateral fractures. The fractures were sustained in motor vehicle accidents in 14 cases. In 16 fractures operative treatment was performed within 36 h. All fractures were reduced indirectly, and 21 fractures were put under axial compression. There was no medial cortex dissection and no primary bone grafting. Secondary bone grafting was necessary in 2 patients, while 1 (diaphyseal fracture) had delayed bone union and required interlocking nailing. In 2 patients varus deformities under 10 degrees were present after completion of bone healing. There were no refractures and no implant failures. Full weight-bearing commenced at 14.7 weeks. Bone healing time was 18.7 weeks in the 19 patients followed up.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Bone loss and forms of tibial condylar fracture.

Bone loss and fracture type were determined in 358 tibial condylar fractures. Degree of osteoporosis at the knee was defined by analogy to Singh's grades of osteoporosis at the hip and to Jhamaria's classification of osteoporosis at the calcaneum: grade V-normal; grade IV-slight reduction of trabecular bone; grade III-osteoporosis, predominantly of trabecular bone; grade II-osteoporosis of trabecular and cortical bone. Five fracture types were distinguished, with the component of trabecular bone compression increasing from a to e: a-pure split fractures; b-split fractures with displacement of a piece of the articular surface; c-split compression fractures; d-local compression fractures; e-compression of a whole condyle. There was a highly significant rank correlation between the two sets of ordered categories. Fractures in osteoporotics tended to involve the lateral condyle; this is explained by the fact that crush fractures occurred more frequently at the lateral condyle. The influence of bone loss on fracture type was demonstrated to be independent of age. A clear understanding of these associations concerning three variables at a time was reached by the use of log-linear-model analysis for cross-classified qualitative data.

Adolescent↗

Clinical evaluation of the sliding compression screw in 121 hip fractures.

Between August 1975 and June 1978, the orthopedic residents at the Jacksonville Health Education Program have used the sliding compression screw to treat 135 hip fractures. The 121 of these being reported include 27 subcapital and femoral neck fractures, 88 intertrochanteric fractures, and six subtrochanteric fractures. Patients' ages ranged from 23 to 98 years, with a mean age of 64. Accurate anatomic reduction of the fracture fragments, be it open or closed, and attention to detail in the placement of the compression screws were thought to be major factors favoring a good result. As confidence was gained in the stability of fixation, appropriate patients were allowed postoperative weight-bearing regimes. It was further concluded that the ability of the sliding screw to allow for a "self-seeking equilibrium" of the fracture fragments obviated the need for primary medial displacement in unstable fractures in almost all instances.

Adult↗

Compression-fixation of long bone fractures: problems and pitfalls revisited.

We have carried out a retrospective study, over a 2.5 year period, of the results of compression-fixation for diaphyseal long bone fractures (forearm 49, tibia 18, others 9). The method was used in forearm fractures mainly for fresh fractures, whilst in fractures of the tibia it was predominantly for delayed union. In forearm fractures, although 10 per cent showed failure of fixation, only 2 per cent developed infection, and 90 per cent recovered a full range of movement. Conversely, plating of fractures of the tibia with delayed union resulted in a 37 per cent deep infection rate. It is concluded that while compression-fixation gives excellent results when applied to displaced forearm fractures, alternative methods should be used in fractures of the tibia with delayed union. This unexpected finding illustrates the value of periodic audit of surgical results.

Fracture Fixation↗

Delayed single Kirschner wire compression technique for mallet fracture.

Twenty-four mallet fractures which involved at least one third% of the articular surface of the distal interphalangeal joint were treated by open reduction and internal fixation using a single double-ended Kirschner wire at a mean of 9 days after injury (range 4-15). At a mean follow-up of 43 (range 12-18) months the active range of motion, pain and the Warren and Norris criteria were evaluated. The mean active range of motion was from - 2 degrees extension (range 0-10 degrees ) to 72 degrees flexion (range 50-90 degrees ). Nineteen patients were pain free and five suffered from mild pain during strenuous work. The Warren and Norris results were successful in 22 and improved in two cases. Radiographs showed, that all the fractures united in a near-anatomic position but with joint narrowing in six digits.

Adolescent↗