Use of laminar flow patterning for miniaturised biochemical assays.

Laminar flow in microfluidic chambers was used to construct low (one dimensional) density arrays suitable for miniaturized biochemical assays. By varying the ratio of flows of two guiding streams flanking a sample stream, precise focusing and positioning of the latter was achieved, and reactive species carried in the sample stream were deposited on functionalized chip surfaces as discrete 50 microm wide lanes. Using different model systems we have confirmed the method's suitability for qualitative screening and quantification tasks in receptor-ligand assays, recording biotin-streptavidin interactions, DNA-hybridization and DNA-triplex formation. The system is simple, fast, reproducible, flexible, and has small sample requirements.

Flow Injection Analysis↗

Determination of chemical oxygen demand in fresh waters using flow injection with on-line UV-photocatalytic oxidation and spectrophotometric detection.

A flow injection manifold incorporating UV-photocatalytic oxidation for the determination of chemical oxygen demand (COD) in freshwater is reported. The method utilises the UV-photocatalytic oxidation of organic compounds instead of conventional heating (used in the standard method), with acidified potassium permanganate as the oxidant. Sodium oxalate, d-glucose and potassium hydrogen phthalate were used as COD standards. A 100 microL sample solution was injected into a 0.3 mol L(-1) H2SO4 carrier stream containing 0.1 mol L(-1) (NH4)2SO4, merged with a permanganate solution (8 x 10(-4) mol L(-1)) and passed through a 250 cm FEP (fluoroethylene polymer) photo-reaction coil wound around a 15 W UV lamp. The sample throughput was 30 h(-1), with an LOD (blank plus 3sigma) of 0.5 mg COD L(-1) and a linear range of 0.5-50 mg COD L(-1) (D-glucose, r2 = 0.9966). The method had good precision with relative standard deviations of 2.7% at 5 mg COD L(-1) and 1.2% at 20 mg COD L(-1) (n = 12) for glucose. Results for a COD certified reference material (QC Demand Quality Control Standard) were in good agreement with the certified COD value. Recovery from Tamar River water samples for all three COD standards was 83.0-111.0% and the COD values determined were in good agreement with those of a permanganate index reference method.

Environmental Monitoring↗

Novel approach for mono-segmented flow micro-titration with sequential injection using a lab-on-valve system: a model study for the assay of acidity in fruit juices.

A new concept for micro-titration using a "lab-on-valve"(LOV) system with sequential injection of mono-segmented flow is proposed. The performance of the system was demonstrated by the assay of acidity in fruit juices which is based on acid-base neutralization. A standard/sample solution containing citric acid, indicator, sodium hydroxide, were sandwiched between air segments and were aspirated in microliter volumes through a selection valve into a holding coil. The acid, indicator, and base were mixed by flow reversal. After removing air segments, the solution was pushed to the detector for monitoring of the change in absorbance of the indicator color, which depended on the concentration of the remaining base. With LOV, microliter volumes of the solution can be detected without dispersion of the color zone. A calibration graph (plot of absorbance vs. acidity value) in the range of 0.2-1.2% (w/v) as citric acid was established. Sample throughput of 30 sample h(-1) and good reproducibility (RSD = 1.2%, n= 11 for 0.6% acidity) were achieved. The procedure has been applied to determine acidity in fruit juices.

Beverages↗

Sensitive determination of heroin based on electrogenerated chemiluminescence of tris(2,2'-bipyridyl)ruthenium(II) immobilized in zeolite Y modified carbon paste electrode.

A novel method for rapid, inexpensive, sensitive and selective determination of heroin was proposed by flow injection electrogenerated chemiluminescence (ECL). Zeolite Y sieves were used for the preparation of a ECL sensor by immobilizing tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) in their supercages, which was achieved through the ion exchange properties of the sieves. The electrochemical and ECL behaviors of Ru(bpy)3(2+) immobilized in zeolite Y modified carbon paste electrode was investigated. The immobilized Ru(bpy)3(2+) displayed a pair of surface-controlled redox peaks with an electron transfer rate constant of 1.2 +/- 0.1 s(-1) in 0.1 mol dm(-3) pH 6.3 phosphate buffer. The modified electrode showed an electrocatalytic response to the oxidation of heroin, producing a sensitized ECL signal. The ECL sensor showed a linear response to flow injection of heroin in the range of 2.0-80 micromol dm(-3) with a detection limit of 1.1 micromol dm(-3). This method for heroin determination possessed good sensitivity and reproducibility with a coefficient of variation of 1.99% (n = 15) at 50.0 micromol dm(-3). The ECL sensor showed good selectivity and long-term stability. Its surface could be renewed quickly and reproducibly by a simple polish step.

Carbon↗

Molecular imprinting-chemiluminescence determination of trimethoprim using trimethoprim-imprinted polymer as recognition material.

A new molecular imprinting-chemiluminescence method for the determination of trimethoprim was developed, in which trimethoprim-imprinted polymer was used as the molecular recognition material and the CL reaction of trimethoprim with potassium permanganate in acidic medium was used as the detection system. The CL intensity responds linearly to the concentration of trimethoprim within the 5.0 x 10(-8)-5.0 x 10(-6) g mL(-1) range (r= 0.9983) with a detection limit of 2 x 10(-8) g mL(-1). The relative standard deviation for the determination of 1.0 x 10(-7) g mL(-1) trimethoprim solutions is 4.8% (n= 9). The method has been applied to the determination of trimethoprim in pharmaceutical preparations and body fluids, and satisfactory results were obtained.

Adsorption↗

Determination of histamine in wines with an on-line pre-column flow derivatization system coupled to high performance liquid chromatography.

A new rapid and sensitive high performance liquid chromatography (HPLC) method for determining histamine in red wine samples, based on continuous flow derivatization with 1,2-naphthoquinone-4-sulfonate (NQS), is proposed. In this system, samples are derivatized on-line in a three-channel flow manifold for reagent, buffer and sample. The reaction takes place in a PTFE coil heated at 80 degrees C and with a residence time of 2.9 min. The reaction mixture is injected directly into the chromatographic system, where the histamine derivative is separated from other aminated compounds present in the wine matrix in less than ten minutes. The HPLC procedure involves a C18 column, a binary gradient of 2% acetic acid-methanol as a mobile phase, and UV detection at 305 nm. Analytical parameters of the method are evaluated using red wine samples. The linear range is up to 66.7 mg L(-1) (r = 0.9999), the precision (RSD) is 3%, the detection limit is 0.22 mg L(-1), and the average histamine recovery is 101.5% +/- 6.7%. Commercial red wines from different Spanish regions are analyzed with the proposed method.

Chromatography, High Pressure Liquid↗

Assessing protease activity pattern by means of multiple substrate ESI-MS assays.

The development of a simultaneous multiple substrate enzymatic assay based on electrospray ionization mass spectrometry (ESI-MS) detection is described. This multiplexing assay scheme was employed in a parallel proteolytic enzyme activity screening. As model systems, the respective activities of trypsin, thrombin, chymotrypsin, bromelain, ficin and elastase towards seven different substrates were assessed. The resulting activity patterns were evaluated semi-quantitatively ranking the enzymatic activities in five classes of activity (very high, high, medium, low and no activity) with respect to the individual substrates. The validity of the MS-based multiplexing assay scheme was proved by comparison with the results obtained from single substrate assays detected by means of UV/vis absorption at 405 nm, showing good agreement of the resulting activity patterns and classifications.

Flow Injection Analysis↗

A DNA assay protocol in a lab-on-valve meso-fluidic system with detection by laser-induced fluorescence.

An automatic protocol for in-situ assay of dsDNA is presented by employing a micro-sequential injection lab-on-valve meso-fluidic system, which facilitates precise fluidic handling at the 0.1-10 microl level. Sub-nano-liter to a few micro-liters of DNA sample and ethidium bromide (EB) solutions were introduced into the meso-fluidic system, where EB binding onto DNA takes place and an intercalated DNA-EB adduct was formed, which was afterwards excited in the flow cell of the LOV by a 473 nm laser beam, and the emitted fluorescence was monitored in-situvia optical fibers. The experimental variables, i.e., pH of the buffer solution, the concentration and volume of EB solution, the reaction time and the fluid flow rates, were investigated. By loading 600 nl sample and 1.0 microl EB solution, a linear calibration graph was obtained within 0.03-3.0 microg ml(-1)(dsDNA), and a detection limit (3sigma) of 0.009 microg ml(-1) was achieved, along with a sampling frequency of 60 h(-1) and a precision of 1.9% at the 1.0 microg ml(-1) level. The detection limit was further improved to 0.006 microg ml(-1) by increasing the sample volume to 2.0 microl. Plasmid DNA in E. Coli extraction and lambda-DNA/Hind III in four synthetic samples were assayed by using this procedure. For the plasmid DNA, a good agreement with the documented UV method was obtained, while spiking recoveries for the synthetic samples were 95.6-103.4%.

DNA↗

On-line electrochemically controlled solid-phase extraction interfaced to electrospray and inductively coupled plasma mass spectrometry.

Electrochemically controlled solid-phase extractions of anions were interfaced on-line to electrospray mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS), using polypyrrole coated electrodes and a thin-layer electrochemical (EC) flow cell. The results indicate that electrochemically controlled solid-phase extraction (EC-SPE) can be used as a versatile potential controlled sample preparation technique for a range of anions and that the properties of the polypyrrole coatings can be modified by altering the electrodeposition conditions. In the present study, the influence of interfering anions (i.e., fluoride and sulfate), and the anion used during the electropolymerisation, on the bromide extraction recovery was investigated for EC-SPE interfaced to ICP-MS. The results of these experiments show that the interference due to the presence of similar concentrations of sulfate can be reduced when using a polypyrrole coating electropolymerised in the presence of bromide ions. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurements were also used to study the morphology of the coatings, as well as the variations in the film thickness within the coatings. The effect of different desorption techniques on the bromide preconcentration factor in the ICP-MS on-line flow system was also examined. Stopped-flow desorption was found to give rise to significantly increased preconcentration factors in comparison with desorptions in flowing solutions. While the desorption efficiency depends on the type of desorption electrolyte (the electrolyte in which the desorption takes place), due to the competing influx of cations, the influence of the pH on the switching charge of the polypyrrole coating was found to be small, at constant ionic strength. To study the applicability of the EC-SPE technique with respect to real samples, investigations were also made with tap water samples spiked with different bromide concentrations. The results of these experiments, which were carried out using a modified thin-layer EC flow cell allowing in situ polymerisation of polypyrrole yielding a polymer plug covering the cross section of the channel, demonstrate that 3 microM concentrations of bromide could be detected in the tap water sample. This demonstrates that the extraction technique allows extractions of low concentrations of ions in the presence of significantly higher concentrations of other similar ions. The fact that the extraction and desorption steps are electrochemically controlled makes EC-SPE particularly well suited for inclusion in miniaturised lab-on-a-chip systems.

Bromides↗

Continuous monitoring with microfabricated capillary electrophoresis chip devices.

We report on the direct coupling of hydrodynamically flowing stream to a microchip capillary electrophoresis (CE) for continuous assays of liquid samples. The new interface relies on mounting the sample tubing onto a sharp inlet tip and allows rapid, convenient and reproducible electrokinetic loading from a continuously flowing stream directly into the narrow separation microchannel. The sharp inlet interface is characterized by its efficiency, stability and simplicity. The effect of the sample flow rate, applied voltages and other relevant variables, is described. It was found that the peak intensity is independent of the flow rate. The performance of the new interface is illustrated for on-line CE-electrochemical monitoring of phenolic and explosive compounds. Conditions simulating continuous long-term monitoring, led to a highly stable response for a 15 ppm 1,3,5-trinitrobenzene solution (RSD = 3.7%, n= 40). Such ability to continuously introduce flowing samples into micrometer channels makes 'lab-on-a-chip' devices highly compatible with real-life monitoring applications.

Electrophoresis, Microchip↗

Flow injection fluorimetric determination of beta-estradiol using a molecularly imprinted polymer.

The steroidal compound 17beta-estradiol (E2) is a major estrogen now widely studied because of its potential endocrine disruption effects. The present paper describes a simple, rapid, flow injection (FI) method for the fluorimetric determination of beta-estradiol involving a molecularly imprinted polymer (MIP) packed into a microcolumn. Microwave-assisted extraction, a relatively new technique, was used to help remove the template from the MIP; this improved extraction efficiency. The optimization of the FI parameters and the intrinsic fluorescence of beta-estradiol allowed its direct determination without a derivatization step. When the possible interference of other estrogens was examined, the system displayed excellent specificity for beta-estradiol; no response to the natural estrogens estrone and estriol and the xenoestrogen bisphenol A was recorded. Under optimum experimental conditions, linear calibration graphs were obtained from 4 to 80 microg L(-1) with a detection limit of 1.12 microg L(-1).

Drug Carriers↗

Identification and quantification of enrofloxacine in poultry feeding water through excitation emission fluorescence and three-way PARAFAC calibration.

In this work an excitation emission molecular fluorescence technique with PARAFAC calibration is proposed for enrofloxacine determination in feeding water from poultry farms. In accordance with the working criteria of the 2002/657/EC European Decision, the proposed method has a capability of detection, CCbeta, of 6.8 microg l(-1), for both probabilities of false positive and false negative of 5%. The accuracy of the method is demonstrated and its precision is 1.7 microg l(-1), expressed as standard deviation. This method allows one to identify and determine the quantity of enrofloxacine present in water samples from poultry farms without it being necessary to determine the possible interferents, nor separate them in a step previous to calibration.

Animals↗

Multiplexed detection of nitrate and nitrite for capillary electrophoresis with an automated device for high injection efficiency.

A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.

Automation↗

Flow-through sensor with Fourier transform Raman detection for determination of sulfonamides.

A flow-through sensor system with Fourier transform (FT) Raman spectroscopy as detection technique is described. The molecular and structural information contained in Raman spectra together with the selective retention of the species of interest on the sorbent make the proposed methodology highly selective. The flow-through sensor allowed the direct quantitative determination of sulfathiazole and sulfamethoxazole in the presence of other species that are normally encountered with these analytes. The system used Sephadex QAE A-25 resin as packing material of a flow-through cell on which sulfonamides were temporarily retained. Samples were transported by a carrier solution of NaOH 10(-2) mol l(-1) (pH = 12), and 2 ml of a [NaCl (0.10 mol l(-1))/NaOH (10(-2) mol l(-1))] solution was employed as eluent. Using a sample volume of 1 ml, the analytical signal was linear in the range 0.5-7 g l(-1) and 0.5-10 g l(-1), for sulfathiazole and sulfamethoxazole, respectively. RSDs (%) lower than 4% were obtained for both analytes. The sensor was satisfactorily applied to several commercial pharmaceutical preparations for human and animals in different physical presentations, including capsules, syrup, tablets, powders, injectables and suspensions.

Flow Injection Analysis↗

Flow injection on-line solid phase extraction for ultra-trace lead screening with hydride generation atomic fluorescence spectrometry.

A flow injection (FI) on-line solid phase extraction (SPE) procedure for ultra-trace lead separation and preconcentration was developed, followed by hydride generation and atomic fluorescence spectrometric (AFS) detection. Lead is retained on an iminodiacetate chelating resin packed microcolumn, and is afterward eluted with 2.5% (v/v) hydrochloric acid to facilitate the hydride generation by reaction with alkaline tetrahydroborate solution with 1% (m/v) potassium ferricyanide as an oxidizing (or sensitizing) reagent. The hydride was separated from the reaction medium in the gas-liquid separator and swept into the atomizer for quantification. The chemical variables and the FI flow parameters were carefully optimized. With a sample loading volume of 4.8 ml, quantitative retention of lead was obtained, along with an enrichment factor of 11.3 and a sampling frequency of 50 h(-1). A detection limit of 4 ng l(-1), defined as 3 times the blank standard deviation (3 sigma), was achieved along with a RSD value of 1.6% at the 0.4 microg l(-1) level. The procedure was validated by determining lead contents in two certified reference materials, and its practical applicability was further demonstrated by analysing a variety of biological and environmental samples.

Flow Injection Analysis↗

On-line dynamic extraction and automated determination of readily bioavailable hexavalent chromium in solid substrates using micro-sequential injection bead-injection lab-on-valve hyphenated with electrothermal atomic absorption spectrometry.

A novel and miniaturized micro-sequential injection bead-injection lab-on-valve (microSI-BI-LOV) fractionation system was developed for on-line microcolumn soil extraction under simulated environmental scenarios and accurate monitoring of the content of easily mobilisable hexavalent chromium in soil environments at the sub-low parts-per-million level. The flow system integrates dynamic leaching of hexavalent chromium using deionized water as recommended by the German Standard DIN 38414-S4 method; on-line pH adjustment of the extract by a 0.01 mol L(-1) Tris-HNO(3) buffer solution; isolation of the chromate leached from the matrix constituents onto a Q Sepharose strong anion-exchanger freshly packed into the microconduits of the microSI-assembly; air-segmented elution of the sorbed species by a 40 microL plug of 0.5 mol L(-1) NH(4)NO(3) (pH 8) eluent; and detection by electrothermal atomic absorption spectrometry (ETAAS). The effect of simulated acidic rain on the accessibility of chromate forms for plant uptake was also investigated. The proposed approach offers several advantages over conventional speciation/fractionation protocols in the batch mode, including immediate separation with concomitant preconcentration of the released chromate, minimization of Cr(vi) to Cr(iii) interconversion risks, enhanced accuracy, and non-existence of re-adsorption/re-distribution problems along with a detailed pattern of the kinetics of the leaching process. The reliability of the proposed method was evaluated via spiking of a moderately polluted agricultural soil material (San Joaquin Soil-Baseline Trace Element Concentrations) with water-soluble Cr(vi) salts at different concentration levels. The potential of the microSI-BI-LOV set-up with renewable surfaces for flame-AAS determination of high levels of readily bioavailable chromate in contaminated soils is also addressed.

Biological Availability↗

Towards biochemical reaction monitoring using FT-IR synchrotron radiation.

A lab-on-a-chip device made of CaF2 windows and SU-8 polymer was used for fluid lamination to achieve rapid mixing of two streamlines with a cross section of 300 x 5 microm each. Time resolved measurements of the induced chemical reaction was achieved by applying constant feeding low flow rates and by on-chip measurement at defined distances after the mixing point. Synchrotron IR microscopic detection was employed for direct and label-free monitoring of (bio)chemical reactions. Furthermore, using synchrotron IR microscopy the measurement spot could be reduced to the diffraction limit, thus maximizing time resolution in the experimental set-up under study. Based on computational fluid dynamic simulations the principle of the set-up is discussed. Experimental results on the basic hydrolysis of methyl chloroacetate proved the working principle of the experimental set-up. First results on the interaction between the antibiotic vancomycin and a tripeptide (Ac2KAA) involved in the build up of the membrane proteins of gram-positive bacteria are presented.

Animals↗