Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Films”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

Model study of interactions of high-molecular dextran sulfate with lipid monolayers and foam films.

The interaction of high-molecular dextran sulfate (DS-5000) with dimyristoylphosphatidylcholine (DMPC) monolayers and foam films (FF) at the air-water interface in the presence of Ca2+ and Na+ ions was studied. DS-5000 was added in monolayer films (MF) and in FF as monomer molecules and in liposomal form. When added in liposomal form in FF, DS-5000 decreased the stability of DMPC common black films (CBF), and no formation of Newton black films (NBF) was observed. However, when included as monomer molecules in FF, DS-5000 caused film thinning, and drastically decreased the expansion rate of the black spots and transition of thick films to NBF, thus avoiding formation of CBF. The above effects were observed in both gel and liquid-crystalline phase states of DMPC in the presence of Ca2+ ions only, and not in the presence of Na+ ions. We postulate that the interaction of DMPC with DS-5000 in the plane of FF is mediated by Ca2+ bridges and results in dehydration of the DMPC polar heads. The interaction between DMPC and DS-5000 in monolayers resulted in slower adsorption and spreading of DMPC molecules at the interface, lower monolayer surface pressure, and penetration of DS-5000 molecules to DMPC monolayers when surface lipid density was higher than 50 A2 per DMPC molecule. The applicability of the FF model for studying the interactions of phospholipids with polysaccharides at interfaces surrounded by bulk solution, and for modeling such interactions in biological systems, e.g. LDL adhesion to the arterial walls, aggregation and fusion of liposomes, etc., is discussed.

Calcium↗

Fungal contribution to in situ biodegradation of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) film in soil.

The contribution of fungi to the microbial degradation of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) films in soil was studied. Various traces, cavities, and grooves observed on the dented surface of PHBV films demonstrated that the degradation was a concerted effect of a microbial consortium colonizing the film surface, including fungi, bacteria, and actinomycetes. The succession of microbial consortia in the soil around the PHBV films during the degradation showed a distinctive increase in the fungal population, resulting in its dominance. Comparison of the degradation ability of microbial strains isolated from soil where PHBV films were degraded, revealed that fungi showed the highest contribution to PHBV degradation, growing very rapidly along the film surface with their high degradation ability and then expanding their hyphae in a three-dimensional manner.

Bacteria↗

Absence or interruption of the supra-acetabular line: a subtle plain film indicator of hip pathology.

OBJECTIVE: To show that absence or interruption of the supra-acetabular line is a subtle plain film indicator of pathology in the acetabulum. DESIGN: Nineteen hips from 17 patients with known disease processes involving the acetabulum as demonstrated by subsequent magnetic resonance imaging, bone scan or plain film follow-up were evaluated with antero-posterior (AP) plain films of the pelvis. Three additional cases were diagnosed prospectively using interruption of the supra-acetabular line as the criterion for inclusion. Fifty AP plain films of the pelvis in patients without hip pain were examined prospectively to determine normal imaging criteria. RESULTS AND CONCLUSIONS: The normal supra-acetabular line measures 2-3 mm in thickness superiorly and is a thin sclerotic line in the medial aspect. In all 22 hips (with pathology) in this series, the line was interrupted or absent. Loss or interruption of the supra-acetabular line may thus be a subtle pain film indicator of a disease process involving the acetabulum. This plain film sign has not previously been reported.

Acetabulum↗

Gallstone ileus: increased diagnostic sensitivity by combining plain film and ultrasound.

BACKGROUND: Gallstone ileus is an uncommon cause of mechanical obstruction. Its high mortality rate can be reduced with earlier diagnosis and treatment. We wanted to determine whether ultrasound (US) performed after plain film increases the sensitivity for the preoperative diagnosis. METHODS: We performed a 5-year retrospective analysis of radiologic and sonographic results of 23 patients who had surgery because of gallstone ileus. RESULTS: Rigler's triad was identified by plain abdominal film in two patients (9%) and by US in 16 patients (69%). Plain abdominal film contributed to a definitive diagnosis in four cases and to a probable diagnosis in six cases (sensitivities of 17% for definitive diagnoses and 43% for definitive and probable diagnoses). US confirmed the diagnosis in six cases of probable gallstone ileus and provided the diagnosis in seven of 13 patients without suspected gallstone ileus based on plain abdominal film. The best results were obtained by combining plain film and US findings, with sensitivities of 74% for definitive diagnoses and 96% for definitive plus probable diagnoses. CONCLUSION: The preoperative diagnosis of gallstone ileus significantly increases by combining plain film and US findings.

Aged↗

Mechanism of the photocatalytic inactivation of Lactobacillus casei phage PL-1 by titania thin film.

The mechanism of the inactivation of Lactobacillus casei phage PL-1 suspended in a phosphate buffer by black-light (BL) -catalytic titanium dioxide (TiO2) thin film was studied. Generation of both superoxide anions (O2-) and hydroxyl radicals (*OH) was confirmed in the aqueous medium in which TiO2 film was settled with BL irradiation under gentle shaking. With BL-irradiation alone without TiO2 film, only O2- was generated to some extent. The genome DNA inside the phage particles was found to be fragmented by the treatment of PL-1 phages with BL-catalytic TiO2 film. The phage inactivation by BL-catalytic TiO2 film was inhibited by the addition of albumin in a concentration-dependent manner. BL-catalytic TiO2 film was considered to cause primarily the damage to the capsid protein through the generation of active oxygen species such as *OH, followed by damage to the genome DNA inside the phage particles.

Antiviral Agents↗

Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen.

The aim of this clinical study was to compare the image quality of digital radiography using the new digital Bucky system based on a flat-panel detector with that of a conventional screen-film system for the skeletal structure and the abdomen. Fifty patients were examined using digital radiography with a flat-panel detector and screen-film systems, 25 for the skeletal structures and 25 for the abdomen. Six radiologists judged each paired image acquired under the same exposure parameters concerning three observation items for the bone and six items for the abdomen. Digital radiographic images for the bone were evaluated to be similar to screen-film images at the mean of 42.2%, to be superior at 50.2%, and to be inferior at 7.6%. Digital radiographic images for the abdomen were judged to be similar to screen-film images at the mean of 43.4%, superior at 52.4%, and inferior at 4.2%; thus, digital radiographic images were estimated to be either similar as or superior to screen-film images at over 92% for the bone and abdomen. On the statistical analysis, digital radiographic images were also judged to be preferred significantly in the most items for the bone and abdomen. In conclusion, the image quality of digital radiography with a flat-panel detector was superior to that of a screen-film system under the same exposure parameters, suggesting that dose reduction is possible with digital radiography.

Adult↗

Evaluation of radiolucency condition in total hip arthroplasty: a statistical comparison of the diagnostic capability of digitised image vs. conventional X-ray film.

This work analyses the diagnostic capability of radiographic images taken from patients with total hip arthroplasty and visualised on monitor. Images were obtained with digital acquisition of conventional X-ray films. The investigated pathology is the absence of direct contact between bone and prosthesis (radiolucency). Three senior orthopaedists defined the diagnostic "truth" on well-defined regions of interest on 22 conventional X-ray films of total hip arthroplasty, obtaining a total of 110 reference ratings. Films were digitised by use of an X-ray scanner. Four readers evaluated the X-ray images, applying conventional and monitor visualisation. To show any difference between ratings on film and ratings on monitor a sensitivity, specificity and accuracy study jointly with a receiver operating characteristics (ROC) study were performed for each reader and for all combined readings. The intra-observer reproducibility of the radiographic protocol was equal to 87% and the inter-observer one was in the range 85-92%. The sensitivity, specificity and accuracy study together with the ROC analysis did not show significant differences between the two evaluation modes. The evaluation of radiolucency from digitised X-ray films visualised on a monitor resulted statistically comparable with the conventional evaluation on X-ray films.

Diagnosis, Computer-Assisted↗

RIS minus PACS equals film.

Web-based integration methods can be used to resolve a fundamental issue in the transition from film to a picture archiving and communication system (PACS): the identification of relevant prior studies only available on film. Even in the most ambitious conversions from a film-based environment to PACS, there are issues regarding prior studies not on PACS. Failure to compare with prior exams is one of the known risk factors for malpractice in radiology. While most commercial PACS systems today have some degree of RIS integration, knowledge of prior studies is usually limited to an awareness of studies in the PACS. On the other hand, most RIS systems today do not or cannot distinguish between studies on film and those in PACS. We made the observation, from a set theory perspective, that in general: Therefore we sought to create a system that would query both the RIS and PACS and reconcile the results using the above set operation. The query is initiated from a display station via the invocation of a Web browser installed on that station. The process of starting the browser is implemented using a scripting language provided by the workstation vendor, though the use of other mechanisms, such as the CCOW (Clinical Context Object Workgroup) or IHE (RSNA Integrated Healthcare Enterprise) interfaces, can be supported by this architecture. The medical record number, which identifies the current patient and is the primary parameter of the query, is passed as part of the URL (Universal Resource Locator) used to launch the browser. Once running, the browser connects to a Web server that hosts a JSP (Java Server Page) page that performs a DICOM query of the PACS and an HL7 query of the RIS, and then collates the results using the set operation described above. Both the DICOM and HL7 functionality are provided by Java-based toolkits developed in house. The results are returned to the client's browser as a standard HTML page with a tabular format detailing which studies are on PACS and which are available only on film. The responsiveness of the system in terms of time required to complete the two queries and display the results was measured. In addition, the number of diagnostic reports, whose retrieval was triggered by the results of the queries, was monitored to determine the overall performance and use of the system. This project demonstrates that, with minimal modification of commercial software, Web-based integration methods exist to enable patient-context sensitive queries from the diagnostic workstation that identify relevant prior studies that exist only on film and are unknown to the PACS. As a result radiologist workflow is enhanced by the elimination of the need to consult a physically separate system for this type of information. In addition, quality of service is improved by providing more accurate and easier identification of relevant prior studies.

Information Storage and Retrieval↗

Measurement of phenols on a loop-supported liquid film by micellar electrokinetic chromatography and direct UV detection.

This paper describes a direct measurement of phenolic substances in the gas phase at levels relevant to occupational health by micellar electrokinetic chromatography (MEKC) using direct ultraviolet detection. A small circular loop (2 mm O.D.) is formed with 100 mm Pt-wire at the sampling end of a fused-silica capillary. The capillary tip of the sampling end is present at the center of the loop and in the same plane. A thin film of 0.50 mM NaOH is formed on the loop by immersion and withdrawal. The film is in fluid communication with the capillary and acts as an absorber for gaseous phenols. Gas sampling is performed by transferring the film-bearing loop into a chamber through which air is aspirated for a preset time at a preselected flow-rate (typically 1 min at 100 cm3/min). A part of the film content is then introduced into the capillary by gravity injection and then MEKC is performed. A total of twelve chloro- and nitrophenols were selected for this study. Under the above sampling conditions, limits of detection (LODs) for various phenols range from high-single-digit to low-double-digit ppbv levels. The effect of several critical parameters, such as the composition of the liquid film and the MEKC running electrolyte, sampling period and film evaporation on the collection efficiency, separation efficiency and calibration behaviour are described.

Adsorption↗

Glass-ionomer cement film thickness and working time.

Reports on film thickness for adhesive glass-ionomer cements have not been consistent, and confusion exists relative to proper working times. In this investigation, film thickness was measured over a range of times for three glass-ionomer cements by using a traditional ADA glass plate technique and a simulated clinical cementation technique with castings and dies. The cements were examined from 60 seconds to 255 seconds from the start of mix. Results indicated that the simulated clinical technique generally provided less film thickness. No significant differences in film thickness were found between the brands of cement through 240 seconds with film thickness ranging from 7.24 to 20.5 microns. Greater differences between the cements were observed with the ADA technique beyond 135 seconds from the time of mix. Relative to film thickness, working times would appear to be greater than previously reported for glass-ionomer cements.

Chemical Phenomena↗

35-mm film scanner as an intraoral dental radiograph digitizer. I: A quantitative evaluation.

A 35-mm slide scanner digital imaging system was tested for its suitability in digitizing intraoral dental radiographic film for quantitative studies. The system (Nikon model LS-3510AF Nikon Electronic Imaging, Nikon, Inc., Melville, N.Y.) uses a charge-coupled device linear photodiode array. The data content in the original film images was evaluated, and the system performance assessed objectively with the use of specially designed test films. Radiometric and geometric performances for the digitizing system were extracted from measurements and observations, and these were compared with published data for two other film digitizing systems (video camera DAGE MTI, Michigan City, Ind. and Barneyscan 35-mm film digitizer Barneyscan, Berkeley, Calif.). The techniques used to evaluate this system are easy and suitable for evaluation of any digitizing system. This scanner system (Nikon) was superior to previously evaluated systems in transforming and recording radiographic film densities across the range (0.3 to 2.0 optical density units) of clinically relevant optical densities. The scanner offers substantial advantage over the other digitizing systems for gray scale information from clinically important optical densities.

Evaluation Studies as Topic↗

Adsorption kinetics of bacterial PHB depolymerase on the surface of polyhydroxyalkanoate films.

The kinetics of adsorption and hydrolysis by an extracellular PHB depolymerase from Alcaligenes faecalis were studied at 37 degrees C on the surface of five types of polyhydroxyalkanoate (PHA) films. The films of poly[(R)-3-hydroxybutyrate] (P(3HP)), poly(3-hydroxypropionate) (P(3HP)), and poly(4-hydroxybutyrate)(P(4HB)) were hydrolyzed by the enzyme, while the films of poly[(S)-2-hydroxypropionate)(P(2HP)) and poly(6-hydroxyhexanoate)(P(6HH)) were not eroded. The PHB depolymerase with binding and catalytic domains adsorbed on the surface of all PHA films used, and the adsorption kinetics were found to obey the Langmuir isotherm. The cross-area per one molecule of enzyme binding to the surface of PHA film was estimated to be 17 +/- 8 (nm2/molecule). It has been concluded that the binding domain of enzyme is non-specific for the binding to the surface of PHA film, while the active site in a catalytic domain is specific for the hydrolysis of PHA molecules.

Adsorption↗

Gas permeability of the film of block and graft copolymers of polydimethylsiloxane and poly(gamma-benzyl L-glutamate).

A-B-A type block copolymers of poly(gamma-benzyl L-glutamate) (PBLG, A segment) and polydimethylsiloxane (PDMS, B segment) and PDMS (trunk)-PBLG (branch) graft copolymers were synthesized, and the permeation of oxygen in water and the permeation of oxygen and carbon dioxide in the dry state were investigated. The gas permeation coefficient (P) increased with increasing content of PDMS. However, PCO2/PO2 values of copolymer films were in the range 6-9, i.e. larger than 5.4 for PDMS film. The oxygen permeation in water suffered from the interfacial resistance, which was reduced by the hydrolysis of film surface. The Arrhenius plot of the gas permeation coefficient in the dry state of the block copolymer B showed a turning point at about 40 degrees C. This temperature is close to beta-peak temperature (39 degrees C) and may be ascribed to the molecular motion of the PBLG segment. Transmission electron microscopy showed that one of the block copolymer films (PDMS 46 mol%) appears to have PDMS segments dispersed in the PBLG matrix (island-in-sea structure) and one of the graft copolymer films (PDMS 58 mol%) appears to take a lamellar structure. The gas permeation across the graft copolymer film appears to occur through the continuous PDMS phase, leading to a near-negligible activation energy in this process.

Biocompatible Materials↗

Immobilization of proteins on poly(methyl methacrylate) films.

Polymethyl methacrylate (PMMA) films were treated by oxygen plasma discharge followed by acrylic acid (AA) grafting. The amount of carboxyl groups introduced by the grafting of AA on to the film surfaces was in the range 0.47-9.48 mumol/cm2, depending on the pressure of the plasma chamber during the discharge treatment. The carboxyl groups of the PMMA film surface previously activated with water soluble carbodiimide were coupled with bovine serum albumin, collagen and gelatin. The protein immobilization on the surface was confirmed by attenuated total reflection Fourier transform infra-red spectroscopy (ATR-FTIR) and electron spectroscopy for chemical analysis (ESCA). The amount of albumin, collagen and gelatin immobilized on the PMMA surface was 6.25, 7.25 and 13.75 micrograms/cm2, respectively, as determined by the coomassie brilliant blue-protein interaction. The water contact angle of the PMMA film was markedly decreased by oxygen plasma treatment, AA grafting or protein immobilization, indicating the increase of hydrophilicity of the surface-modified PMMA films. The protein-immobilized PMMA films may be widely used as a biocompatible material.

Biocompatible Materials↗

Effect of specimen support film in solid phase immunoelectron microscopy.

The type of grid support film used in solid phase immunoelectron microscopy (SPIEM) for poliovirus affected the efficiency of virus trapping. Parlodion/carbon films coated with homologous antiserum were found to be 9 times more efficient in trapping virus than similar grids prepared with Formvar/carbon, and 20 times better than SPIEM grids prepared with pure carbon films. Trapping efficiency could be further improved if support films were pretreated prior to exposure to viral antiserum. Maximum efficiency was obtained with Parlodion/carbon films pretreated with UV light. Almost as efficient were Parlodion/carbon and Formvar/carbon films pretreated with glow discharge ionization.

Antibodies, Viral↗

Appropriateness of plane pressure-sensitive film calibration for contact stress measurements in articular joints.

OBJECTIVE: To examine how accurately calibration stains from pressure-sensitive film samples compressed between perfectly flat surfaces represent contact pressures measured with the film inserted between curved joint surfaces. DESIGN: Experimental study. BACKGROUND: Contact pressure distributions and areas in joints are often quantified using pressure-sensitive film inserted between the articular surfaces. Absolute pressure values are recovered from the film through a calibration procedure. Since the calibration is typically performed in a different environment from the experimental measurements, a systematic error in the pressure magnitudes may be introduced. METHODS: Calibration stains were produced with an Instron machine using a flat and a slightly curved indenter. Calibration curves were fitted to the raw data of both indenters using a model representing the functional characteristics of the pressure-sensitive film. RESULTS: No systematic differences between the calibration curves from the flat and the curved indenter were observed. CONCLUSIONS: It appears that calibration with the film in a flat configuration is adequate for contact pressure measurements between moderately curved articular surfaces.

Journal Article↗

A new system for port films.

A novel system for port films is described which incorporates a high-quality fluorescent screen lying behind a flat, heavy-metal screen or filter and the film pressed between them is not an X ray type but a single-emulsion, very high contrast graphics or line-type film. In experimental comparisons using 4 MV, 6 MV, and 25 MV photon beams, the new Peter MacCallum Cancer Institute (PMCI) system produced clearer images, about X2 higher in contrast yet lower in relative noise levels, than did the conventional commercially-available systems which use x-ray film between heavy-metal screens. Direct clinical comparisons, chiefly using 6 MV accelerators, confirmed that anatomical details were correspondingly better visualized and in general, the PMCI port film could be matched against the simulator radiograph with greater confidence. Routine use for greater than 2 yr in this Institute (4000 new patients per yr, 20 cassettes made for use with four 6 MV accelerators) has shown the PMCI system to be an economical and practical device, giving reproducibly high quality images in all the common port film applications.

Humans↗

Portal film enhancement: technique and clinical utility.

We report on the results a 3-year project which had as its goal the development of methods to enhance radiation portal films to improve their readability. We had previously reported on a portal film enhancement technique, contrast limited adaptive histogram equalization, which could enhance low contrast detail, but degraded sharply contrasted edges. A new method, unsharp masking followed by contrast limited adaptive histogram equalization, now appears to overcome this problem. A clinical trial to test whether enhanced portal films could be read more accurately than standard ones was undertaken. The trial involved 12 readers from two institutions doing 276 readings. In this trial the enhanced films were judged to be of higher quality than the non-enhanced films (p < .001) and were read more accurately (p = .026). The usefulness and difficulties of routinely performing portal film enhancement in a busy radiation therapy department are discussed.

Humans↗

Refine your search to explore more results.