New contraceptive method, female-worn condom, approved by FDA panel.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
OBJECTIVES: The purpose of this presentation is to document results of buttoned device (BD) occlusion of patent ductus arteriosus (PDA) in a large number of patients with particular emphasis on long-term follow-up in an attempt to provide evidence for feasibility, safety and effectiveness of this method of PDA closure. BACKGROUND: Immediate and short-term results of BD occlusion of PDA have been documented in a limited number of children. METHODS: During a six-year period ending August 1996, transcatheter BD closure of PDA was attempted in 284 patients, ages 0.3 to 92 years (median 7) under a protocol approved by the local institutional review boards and FDA with an investigational device exemption in U.S. cases. RESULTS: The PDAs measured 1 to 15 mm (median 4) at the narrowest diameter; 20 were larger than 8 mm and 10 larger than 10 mm. They were occluded with devices measuring from 15 to 35 mm delivered via 7F (N = 140) or 8F (N = 144) sheaths. Successful implantation of the device was accomplished in 278 (98%) of 284 patients. The Qp:Qs decreased from 1.8+/-0.6 (mean+/-SD) to 1.09+/-0.19 (p < 0.001). Effective occlusion defined as no (N = 167 [60%]) or trivial (N = 79 [28%]) residual shunt was achieved in 246 (88%) patients. All types of PDAs, irrespective of the shape (conical, tubular or short), size (small or large) or length (short or long) of the PDA and previously implanted Rashkind devices, could be occluded. Follow-up data, 1 to 60 months (median 24) after device implantation, were available in 234 (84%) patients. Seven (3%) patients required reintervention to treat residual shunt with (N = 2) or without (N = 5) hemolysis. Actuarial reintervention-free rates were 95% at 1 and 5 years. There was gradual reduction of actuarial residual shunts and were 40%, 28%, 21%, 14%, 11%, 10%, 6% and 0% respectively at 1 day, 1, 6, 12, 24, 36, 48 and 60 months after device implantation. Incorporation of folding plug over the button loop in 10 additional patients produced immediate and complete occlusion of PDA. CONCLUSIONS: This large multiinstitutional experience confirms the feasibility, safety and effectiveness of buttoned device closure of PDAs. All types of PDAs irrespective of the shape, length and diameter can be effectively occluded. Incorporation of folding plug over the button loop produces complete PDA occlusion at the time of device implantation.
In a press conference on Nov. 20, 2001 it was announced that the Multi-center Autonomic Defibrillator Implantation Trial II (MADIT II) was stopped early because of a 30% reduction in mortality in patients randomised to receive an implantable defibrillator device. The 4 year multi-centre trial of 1200 patients was terminated early after an independent board observed that the post-MI patients with impaired left ventricular function receiving the implantable defibrillator had improved survival rates compared to those receiving conventional treatment. The MADIT II trial's aim was to test whether an AICD will reduce mortality in high-risk patients with coronary artery disease and left ventricular dysfunction with no arrhythmia entry criteria. The intention was to recruit 1200 patients aged 21-85 years with left ventricular ejection fraction (EF) <or=0.30. Exclusion criteria included myocardial infarction within 1 month, coronary artery bypass graft or percutaneous transluminal coronary angioplasty within 2 months, and any patient already satisfying criteria for receiving an AICD by satisfying the entry criteria for the first MADIT trial. The primary end-point was all-cause mortality. Pre-specified secondary outcomes included non-cardiovascular mortality, sudden death, non-fatal myocardial infarction, fatal myocardial infarction, non-fatal cardiac arrest, fatal cardiac arrest, quality of life, and an economic evaluation. A positive outcome for this trial would be a major step forward both in delineating the indication for AICD therapy but also in guiding routine therapy for patients with impaired left ventricular function as defined by a reduced LVEF. This is not the first positive trial for the AICD approach to preventing sudden deaths due to ventricular tachyarrhythmias. Previous trials (MADIT, MUSST and AVID) have demonstrated that implantable defibrillators improve survival in other patient populations. Under current U.S. Food and Drug Administration (FDA) guidelines restricting the use of AICD therapy to defined patient criteria, 300,000 patients each year in the United States are estimated to be eligible to receive an implantable defibrillator. Guidant was quoted as saying that once the complete study findings of MADIT II are published it plans to submit an application to the FDA that, if approved, could double the population of patients eligible for the implanted devices in the USA, clearly having a major impact on care and its costs for the heart failure and post-MI populations.
PURPOSE: We describe our initial experience with the Abiomed AB5000 ventricular assist device (VAD). DESCRIPTION: The Abiomed AB5000 VAD is a system recently approved by the Food and Drug Administration that consists of a fully automatic, vacuum-assisted console and a paracorporeal, pneumatically driven blood pump. The VAD is designed for short or intermediate term use. The console is designed to support the BVS5000 or AB5000 blood pumps. The cannulas and implantation are similar to the BVS5000 system. EVALUATION: Four cases are described in which two AB5000 systems were placed de novo and two were transitioned from previously placed BVS5000 units. Hemolysis was observed in 2 cases. The AB5000 VAD flows were generally 4.0 to 4.5 L/min, approximately 0.5 L/min less than the BVS5000. Echocardiography demonstrated high-velocity jets from the inflow cannula in the 2 hemolysis cases. One patient died of multiorgan system failure while on support, 2 were successfully weaned from support and transferred to long-term care facilities, and 1 was weaned from support and successfully discharged to home. CONCLUSIONS: The AB5000 VAD is a versatile paracorporeal pneumatic VAD that can be placed de novo or transitioned from a previously placed BVS5000 unit without the need for additional surgery. Lower outputs, high-velocity jets, and hemolysis were observed in 2 of 4 cases. Modifications in cannulas design and placement as well as console reconfigurations may be necessary to optimize performance.
OBJECTIVE: To review the incidence of venous thromboembolism (VTE) after radical retropubic prostatectomy (RRP) and evaluate the need for heparinoid prophylaxis as opposed to mechanical compression devices after RRP. PATIENTS AND METHODS: RRP is classified as a category 1 (high risk) procedure for VTE by the American College of Chest Physicians and several international guidelines recommend subcutaneous heparinoids as the preferred prophylaxis. However, this regimen may be associated with a greater risk of bleeding. We have not used heparinoid prophylaxis but place a mechanical compression device for prophylaxis of VTE, and report our clinical experience over a 12-year period. Between 1992 and 2004, all RRPs carried out by one surgeon (M.S.S.) at our centre were retrospectively reviewed after obtaining institutional review board approval. The protocol for prophylaxis of VTE consisted of compression stockings and a sequential compression device from the time of entry into the operating room until complete ambulation (we encourage early ambulation). Patients were evaluated for VTE if they developed any clinical signs or symptoms. Patients were followed at 7 days, 6 weeks and 3 months after RRP in the first year and 6-monthly thereafter. All relevant clinical data and complications were entered in a database. RESULTS: In all there were 1364 RRPs; the mean (sd) age of the patients was 61 (7) years and the mean follow-up 44 (38) months. All patients had a mechanical compression device and ambulated on the first day after surgery. None received heparinoid prophylaxis. Three VTE events were identified (0.21%); two patients had a lower limb VTE and one an upper limb VTE. All were successfully treated with anticoagulation. No patient had a documented pulmonary embolus and none died from VTE. There was one death after RRP, from myocardial infarction. CONCLUSION: The incidence of VTE after RRP is low, possibly related to the use of a mechanical compression device and early aggressive mobilization. Despite the recommendations by some, we feel that routine heparinoid prophylaxis is questionable.
Large, multicenter, randomized trials of IUDs conducted between 1970 and 1986 encompass more than 50,000 woman-years of experience in the two-year interval following device insertion. Taken singly and collectively, these trials demonstrate that IUD failure rates are strongly affected by the age of participants, notably by the proportion of women under age 25 admitted to the studies. Individual trials and overall comparisons indicate further that: 1. Non-medicated devices such as the Mahua steel ring and Lippes loop D have pregnancy rates above 2 per 100 woman-years. 2. The first approved copper IUDs, the Copper 7 and the TCu 200, do not markedly differ in pregnancy rates from standard plastic devices with rates significantly above 2 per 100 woman-years. 3. Five more recent, widely used copper IUDs have had failure rates significantly below 2 per 100 woman-years in multicenter trials. The point estimate of the failure rate was less than 1 pregnancy per 100 woman-years for three of these IUDs. One copper-bearing device had a failure rate significantly below 1 per 100 woman-years. 4. Devices releasing either 25 mcg/day of progesterone or 2 mcg/day of levonorgestrel have had significantly higher failure rates than the more effective copper-releasing IUDs; however, devices releasing 20 mcg/day of levonorgestrel appear at least as effective as the most effective copper IUDs. Long-term IUD failure rates derived from straight assignment as well as randomized trials indicate 4-year gross cumulative failure rates do not exceed 10 per 100 for any of the standard copper devices or the Lippes loop D. Point estimates of the four-year gross cumulative pregnancy rates have been below 5 per 100 users in studies of the TCu 220C, the Nova T, the TCu 380A, and the MLCu 375.
The transition to filmless radiology is a much more formidable task than making the request for proposal to purchase a (Picture Archiving and Communications System) PACS. The Department of Defense and the Veterans Administration have been pioneers in the transformation of medical diagnostic imaging to the electronic environment. Many civilian sites are expected to implement large-scale PACS in the next five to ten years. This presentation will related the empirical insights gleaned at our institution from a large-scale PACS implementation. Our PACS integration was introduced into a fully operational department (not a new hospital) in which work flow had to continue with minimal impact. Impediments to user acceptance will be addressed. The critical components of this enormous task will be discussed. The topics covered during this session will include issues such as phased implementation, DICOM (digital imaging and communications in medicine) standard-based interaction of devices, hospital information system (HIS)/radiology information system (RIS) interface, user approval, networking, workstation deployment and backup procedures. The presentation will make specific suggestions regarding the implementation team, operating instructions, quality control (QC), training and education. The concept of identifying key functional areas is relevant to transitioning the facility to be entirely on line. Special attention must be paid to specific functional areas such as the operating rooms and trauma rooms where the clinical requirements may not match the PACS capabilities. The printing of films may be necessary for certain circumstances. The integration of teleradiology and remote clinics into a PACS is a salient topic with respect to the overall role of the radiologists providing rapid consultation. A Web-based server allows a clinician to review images and reports on a desk-top (personal) computer and thus reduce the number of dedicated PACS review workstations. This session will focus on effective strategies for a seamless transition. Critical issues involve maintaining a good working relationship with the vendor, cultivating personnel readiness and instituting well-defined support systems. Success depends on the ability to integrate the institutional directives, user expectations and available technologies. A team approach is mandatory for success.
PURPOSE: To review current and potential future regulatory status of intravascular brachytherapy (IVB) systems. METHODS: There are three approved IVB systems; two commercial IVBs are hand-operated manual devices; the third is remotely operated. In three Guidances, the Nuclear Regulatory Commission (NRC) applied certain regulatory concepts applicable to remotely operated high dose rate (HDR) afterloaders to manually operated IVBs. This article reviews these Guidances, newly released NRC regulations on the medical use of by-product material, and potential regulatory issues related to IVB systems. RESULTS: The Guidances are specific. However, newly released NRC regulations on the medical use of byproduct material, including HDR afterloaders, omit IVB systems as a category. NRC licensure of IVB systems is considered case-by-case. CONCLUSIONS: The current limited application of regulations applicable to HDR remote afterloaders to hand-held IVB systems could lead to other HDR-like regulations for hand-held IVB systems in future regulations.
Since the advent of Medicare's prospective payment system, beneficial but cost-increasing medical advances have been systematically assigned to existing diagnosis-related groups (DRGs) that do not cover the costs of the new technology. Recent evidence suggests that such underpayment reduces the rate at which hospitals adopt that technology. Safeguards designed to offset the negative incentives of underpayment, including the recalibration of DRG values, update factors, and the allowance of Medicare profits, appear not to have worked. We studied the case of cochlear implantation. Years after Food and Drug Administration approval and a favorable decision about Medicare coverage, payment for the device remains well below its average cost, and many hospitals ration the availability of the device to Medicare patients because of the financial losses involved. Eventually, so few patients received the implant that the original manufacturer discontinued its production. Under the DRG system, negative payment incentives compete with clinical considerations when hospitals and physicians decide whether to adopt specific cost-increasing new forms of technology of proved value. Other payment mechanisms that do not insert arbitrary financial considerations into specific treatment decisions should be considered instead.
STUDY DESIGN: A case involving microradiographic and histopathologic analysis of an explanted human corpectomy mesh cage is reported. OBJECTIVE: To describe the clinical circumstance, the radiographic appearance, and the histopathologic assessment of a titanium mesh device explanted from a two-level corpectomy. SUMMARY OF BACKGROUND DATA: To the authors' knowledge, no published microradiographic or histopathologic reports have described a retrieved human corpectomy cage. METHODS: The explanted device was stained using Osteochrome Villanueva bone stain and underwent routine decalcified histologic processing and embedding in polymethylmethacrylate. Midsagittal sections were prepared and polished to 100 microm for histologic and microradiographic analysis. RESULTS: Microscopic analysis demonstrated normal-appearing lamellar and woven trabecular bone in close contact with the titanium implant interface. Further analysis of serial sections indicated that, on the average, 35% (range, 30-40%) of the inner device region contained trabecular bone. CONCLUSION: Osteosynthesis and bone remodeling can occur within titanium corpectomy cages. METHODS: This study involved one titanium mesh device (Harms cage), 20 mm in diameter and 45 mm long, explanted from a two-level corpectomy clinical case. This device was retrieved, processed, and analyzed after informed patient consent and approval from the authors' institutional review board.
Cerebral revascularization strategies for acute ischemic stroke have been developed during the past decade. Many of these strategies are currently being evaluated and gaining in popularity, offering hope to those with an otherwise nihilistic disease. Herein, the authors discuss the current progress toward these goals and the efforts being made to develop a safe and efficacious method of clot removal in the treatment of acute ischemic stroke. Three endovascular treatment strategies are presented: endovascular thrombectomy with suction or snaring devices, mechanical clot disruption with mechanical or photoacoustic devices, and augmented fibrinolysis with mechanical or ultrasonic devices. Most of these devices are currently undergoing phase I or II trial or are approved for other uses.
Women can use emergency contraception to prevent pregnancy after known or suspected failure of birth control or after unprotected intercourse. Many patients do not ask for emergency contraception because they do not know of its availability. Emergency contraception has been an off-label use of oral contraceptive pills since the 1960s. Dedicated products, the Yuzpe regimen (Preven) and levonorgestrel (Plan B), were marketed in the United States after 1998 but had been available in Europe for years before that. A third approved method of emergency contraception is the insertion of an intrauterine device. Emergency contraception is about 75 to 85 percent effective. It is most effective when initiated within 72 hours after unprotected intercourse. The mechanism of action may vary, depending on the day of the menstrual cycle on which treatment is started. Despite the large number of women who have received emergency contraception, there have been no reports of major adverse outcomes. If a woman becomes pregnant after using emergency contraception, she may be reassured about the lack of negative effects emergency contraception has on fetal development. It may be beneficial for physicians to offer an advance prescription for emergency contraception at a patient's regular gynecologic visit to help reduce unwanted pregnancies. Advance provision of emergency contraception can increase its use significantly without adversely affecting the use of routine contraception.
Explore the source record for details and available documents.
The conduct of a clinical investigation of a medical device to determine the safety and effectiveness of the device is covered by the investigational device exemptions (IDE) regulation. The purpose of IDE regulation is "to encourage, to the extent consistent with the protection of public health and safety and with ethical standards, the discovery and development of useful devices intended for human use, and to that end to maintain optimum freedom for scientific investigators in their pursuit of this purpose" (Federal Food, Drug, and Cosmetic Act). Conducting a clinical investigation may require an approved IDE application. The US Food and Drug Administration encourages early interaction with the agency through the pre-IDE process during the development of a device or technology and during the preparation of an IDE application. This facilitates approval of the IDE application and progression into the clinical investigation. This paper reviews the terminology and applicability of the IDE regulation and the type of study that requires an IDE application to the Food and Drug Administration. The pre-IDE process and the development of an IDE application for a significant risk study of a cardiovascular device are discussed.
The actual methods of postcoital emergency contraception are described and compared. The method of choice is the administration of a progestagen-only pill because this method is more reliable and effective than the use of a combined estrogen-progestagen pill ("Yuzpe-Method"), and because the incidence of side-effects is considerably lower. The results obtained with levonorgestrel alone are presented by the authors. The postcoital introduction of a copper intrauterine device is highly effective, but invasive. This method is indicated if it is too late to use the pill. An open and accepting setting of the consultation and a way of taking the medical history that is pointing to the auto-responsibility are essential, especially for adolescents. Low conditions for the admission to the counselling are postulated, and the obligation to possess a medical prescription to obtain the only progestagen-only pill is questioned.
There has been extensive research on drug delivery by biodegradable polymeric devices since bioresorbable surgical sutures entered the market two decades ago. Among the different classes of biodegradable polymers, the thermoplastic aliphatic poly(esters) such as poly(lactide) (PLA), poly(glycolide) (PGA), and especially the copolymer of lactide and glycolide referred to as poly(lactide-co-glycolide) (PLGA) have generated tremendous interest because of their excellent biocompatibility, biodegradability, and mechanical strength. They are easy to formulate into various devices for carrying a variety of drug classes such as vaccines, peptides, proteins, and micromolecules. Most importantly, they have been approved by the United States Food and Drug Administration (FDA) for drug delivery. This review presents different preparation techniques of various drug-loaded PLGA devices, with special emphasis on preparing microparticles. Certain issues about other related biodegradable polyesters are discussed.
Owing to the permissible tolerances, even successfully tested automatic blood pressure devices may deliver quite false values. In the largest hypertension study (HOT study) so far carried out, the use of an oscillometric device cannot be considered to provide the "evidence base" for the tacit abandonment of the nonautomatic Korotkoff method, in particular in view of the contradictions in the published data on the device employed. When automatic devices are used in clinical trials, special regulations in the testing protocols of the devices, and a critical consideration of measuring methods in the discussion of the results, are mandatory.
BACKGROUND: Left ventricular assist system technologies are currently being developed as effective alternatives to cardiac transplantation. In this study, in vivo testing of the Arrow International CorAide left ventricular assist system was conducted to determine its preclinical readiness based on demonstrated system performance and biocompatibility. METHODS: Arrow International CorAide blood pump assemblies were implanted in 7 calves for 1-month (n = 4) and 3-month (n = 3) durations without the use of chronic anticoagulation therapy. Hemodynamic performance, physiologic pump control, end-organ function, and device-related adverse events were evaluated during the studies and at autopsy. RESULTS: Hemodynamics were stable in all cases with a mean pump flow of 4.1 +/- 0.8 L/min and a mean arterial pressure of 101 +/- 4 mm Hg. In all calves, renal and hepatic function remained normal with no incidence of hemolysis, infection, bleeding, or embolism. The CorAide physiologic control algorithm demonstrated appropriate pump speed and flow adjustments in response to physiologically induced inputs, and the system's external electronic components demonstrated no hardware or software malfunction. All 7 cases were sacrificed electively. Autopsy revealed no sign of end-organ disease on gross and histologic examinations, and no device failure, malfunction, or mechanical wear of the pump blood-bearing surfaces was found. CONCLUSIONS: The Arrow CorAide left ventricular assist system demonstrated effective pump performance and good biocompatibility with no incidence of device-related adverse events. This system has completed its preclinical readiness testing and is approved for clinical trials in Europe in 2003.
Refine your search to explore more results.