Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

Marginal adaptation and hardness of resin composite restorations activated with four energies.

PURPOSE: The purpose of this study was to evaluate the influence of variations in light intensity versus exposure time, under the same energy density, on the marginal adaptation and hardness of resin composites restorations. MATERIALS AND METHODS: The occlusal surfaces of 20 third molars were flattened with 180-grit SiC paper and a Class I cavity was prepared (4 mm wide, 4 mm long, and 2 mm deep). The specimens were randomly divided into four groups (n = 5 teeth). The adhesive system was applied according to the manufacturer's directions followed by one increment of Filtek Z250. The resin composite was light activated with 18 J/cm(2) according to one of the following light intensities/exposure times: group 1-100 mW/cm(2)/180 s; group 2-300 mW/cm(2)/60 s; group 3-600 mW/cm(2)/30 s; group 4-1,000 mW/cm(2)/18 s. After 24 hours, the restorations were longitudinally sectioned into two halves. Enamel, bottom, and total mean gap widths (in micrometers) were measured with a stereomicroscope (x200). After that, one of the sections was embedded in acrylic resin and polished up to 4,000-grit SiC for Knoop hardness number (KHN) measurements (100 g/15 s) at the top and bottom surfaces. The data from mean gap widths were analyzed by one-way analysis of variance (ANOVA). The KHN values (kg/mm(2)) were subjected to a two-way, repeated-measures ANOVA (a = .05). Tukey's test was used for pairwise comparisons. RESULTS: No significant difference was observed between total and bottom mean gap widths among groups (p > .05). Group 1 showed lower enamel mean gap widths than did groups 3 and 4 (p < .05) but similar to those for group 2 (p > .05). The KHN at the top surface was higher than the bottom hardness (p < .05). For the bottom surface, all groups had similar KHN values (p > .05). CONCLUSIONS: The variations in light intensity and exposure times allowed the achievement of adequate mechanical properties. The use of a low light intensity reduces only the enamel mean gap width but has no effect on the overall gap formation along the composite-tooth interface. CLINICAL SIGNIFICANCE: As long as an adequate energy density is used to produce adequate mechanical properties in the resin composite, the use of a low light intensity for an increased time does not markedly improve marginal integrity.

Analysis of Variance↗

Evaluation of 2 thione primers and 3 resin adhesives for silver-palladium-copper-gold alloy bonding.

OBJECTIVE: The purpose of this study was to evaluate 2 thione primers and 3 resin adhesives for enhancement of bonding strength to a silver-palladium-copper-gold alloy. METHOD AND MATERIALS: Two different sized disk specimens (10- and 8-mm diameter by 2.5-mm thick) were prepared from a silver-palladium-copper-gold alloy (Castwell M.C. 12, GC). The specimens were airborne-particle abraded with 50-microm-grain alumina, conditioned either with a thiouracil primer (Metaltite, Tokuyama Dental) or with a triazine dithione primer (V-Primer, Sun Medical), and then bonded with 1 of 3 acrylic resins: a benzoyl peroxide-amine redox-initiated resin adhesive (Multi-Bond, Tokuyama Dental) or a tri-nbutylborane-initiated resin adhesive (Super-Bond C&B and Super-Bond Quick, Sun Medical). For each adhesive, unprimed specimens were prepared as experimental controls. Shear bond strength was determined after thermocycling (100,000 cycles). RESULTS: Use of primers significantly (P < .05) enhanced the bond strength of specimens in all adhesives. Irrespective of the type of primer, the strength of Multi-Bond adhesive was significantly (P < .05) lower than that of Super-Bond C&B and Super-Bond Quick adhesives. The strength of the 2 tri-n-butylborane-initiated adhesives did not differ significantly (P > .05). The mean strength of the Super-Bond C&B adhesive was 40.4 MPa with Metaltite and 37.8 MPa with V-Primer; that of Super-Bond Quick adhesive was 40.9 MPa with Metaltite and 36.5 MPa with V-Primer. CONCLUSION: Use of thione primers effectively enhanced the strength of the bond to the silver-palladium-copper-gold alloy. Furthermore, the combinations of primers and tri-n-butylborane-initiated adhesives were found to be more efficient for bonding.

Air Abrasion, Dental↗

Comparative strengths of metal framework structures for removable partial dentures.

STATEMENT OF PROBLEM: The framework of removable partial dentures often breaks where the metal retention for the resin denture base attaches to the clasp and major connector. PURPOSE: To study these failure factors, various types of three-dimensional simulated denture frameworks were designed to measure their ultimate strengths and stiffnesses under static load. This study also sought to determine which could be recommended for long-term clinical service. MATERIAL AND METHODS: Three groups of three-dimensional frameworks (double, T-shaped, and trussed structure) were designed, and two groups of classic framework designs (uniform and nonuniform skeleton) were used with an acrylic resin block as a control (n = 5 per group). Fatigue strength, stiffness and amount of strain, and free-end displacement under dynamic loads were measured for each framework. The fatigue strength was determined with a constant-loading fatigue test by counting the number of loading cycles required to induce catastrophic failure. RESULTS: With 20 kgf of load, four T-shaped samples and three trussed structure samples failed at 30,000 to 60,000 loading cycles. No samples of double structure group failed until 100,000 loading cycles. CONCLUSIONS: Three-dimensional frameworks, especially the double structure, have significant differences in fatigue strength and can provide long-term clinical service.

Chromium Alloys↗

Effect of insertion technique and adhesive system on microleakage of Class V resin composite restorations.

PURPOSE: To evaluate the effect of different insertion techniques and adhesive systems on microleakage of Class V composite resin restorations. MATERIALS AND METHODS: Forty-eight human molars were randomly assigned to four groups (n = 12). Standardized mixed Class V cavities (enamel and dentin margins) were prepared at the CEJ. A total-etch (Adper Scotchbond MultiPurpose) and a self-etching (iBond) adhesive system were evaluated using either an incremental or single-step (bulk) insertion technique. The preparations were restored with Esthet*X micromatrix hybrid composite. The teeth were thermocycled 1000 cycles, immersed in 1% methylene blue dye for 24 h, and invested in acrylic resin. The specimen blocks were then sectioned longitudinally, with dye penetration (microleakage) examined with a 20X binocular microscope. Enamel and dentin margins were scored separately for microleakage using an ordinal ranking system. Results were analyzed using non-parametric tests at a p < 0.05 level of significance. RESULTS: Significance was exhibited between the groups (adhesive material/insertion technique) at the coronal and apical margins. At the coronal margin, the total-etch adhesive/incremental insertion group exhibited significantly less leakage than the other groups, while at the apical margin, the total-etch adhesive/incremental insertion group showed significantly less leakage than the self-etching adhesive/bulk insertion group. Significantly less leakage was found at the coronal margins compared to the apical margins of the material/technique groups. CONCLUSION: The use of a total-etch adhesive system and incremental insertion of composite significantly reduced microleakage at the coronal and apical margins of Class V composite restorations.

Coloring Agents↗

Bond strengths of composite resin and compomers in primary and permanent teeth.

Previous clinical and in vitro studies have shown a higher failure rate of composite resins and conventional glass ionomer cements in primary teeth when compared to permanent teeth. A new generation of light-cured glass ionomer cements (compomers) were suggested to be used as restorative materials for the primary teeth. This study was conducted into two parts. The objective of the first part was to compare shear bond strength of compomers (Compoglass and Dyract) and composite resin (Herculite/Optibond) in both primary and permanent teeth. Buccal and lingual surfaces of extracted sound human primary and permanent molars were ground flat on 600-grit SiC paper and divided into 6 groups of 10 surfaces each. The materials were handled according to the instructions of the manufacturer and placed on to the tooth surfaces via clear plastic tubes of 3 mm in diameter. After light curing for 40 seconds, all samples were thermocycled in water bath of 5 degrees F and 55 degrees F for 500 cycles. The samples were embedded in acrylic resin and sheared with an Instron running at a crosshead speed of 0.5 mm/min. Results (mean shear bond strength) were recorded in MPa. Factorial ANOVA revealed that shear bond strength of Herculite/Optibond in the primary teeth (6.07 +/- 2.63) was significantly lower than that of the permanent teeth (17.61 +/- 4.34) (p < 0.0001), but there was no statistically significant difference of bond strength of Compoglass and Dyract between the primary and the permanent teeth. The results from the first part revealed that no materials tested in the primary teeth could provide a shear bond strength of at least 17.6 MPa as recommended. Thus, the objective of the second part of this study was to evaluate shear bond strength of composite resin (Herculite) using three different dentinal bonding agents (Optibond, One-Step and Amalgambond) in the primary teeth. Methods employed in this part were similar to that of the first part. Results showed that Amalgambond provided significantly higher mean shear bond strength (17.96 +/- 5.77) than One-step (11.79 +/- 4.73) and Optibond (6.07 +/-/- 2.63) as tested by Kruskal-Wallis ANOVA and Mann-Whitney U test (p < 0.0001).

Adhesiveness↗

Of plants and other pets: practical aspects of freeze-substitution and resin embedding.

Representative tissues from higher plants (e.g. developing pollen, somatic anther tissues from the monocotyledonous angiosperm Ledebouria) and mammalian cell cultures were successfully cryoimmobilized by means of high-pressure freezing. Various substitution and embedding protocols were then evaluated considering the preservation of ultrastructural details, membrane staining, immunolabelling properties, as well as reproducibility and ease of use. Two types of recipe proved to be highly suitable for most applications, regardless of type, developmental stage or physiological conditions of the cells: (i) the best choice for morphology is still osmium in acetone (optionally supplemented with uranyl acetate) followed by embedding in Epon and/or Araldite; (ii) feasible approaches for immunocytochemistry are freeze-substitution with ethanol containing uranyl acetate and formaldehyde, or with pure acetone (in the case of fixation-sensitive antigens), followed by embedding with LR-white acrylic resin; though being far from optimal, these combinations represent, in my opinion, an acceptable compromise between labelling intensity, section stability, structural preservation and health hazards. Notably, the patterns observed in Ledebouria were consistent with data obtained from a broad range of other specimens from all kingdoms (e.g. leaves and callus cultures from angiosperms, gymnosperm roots with their ectomycorrhizal fungi, mammalian cell cultures and eubacteria). Finally, a warning is given as to the extractive potentials of embedding resins (Spurr's mixture, LR-white, but also Epon) being sometimes the cause of unacceptable artefacts, both in plant and in mammalian cells prepared by cryoimmobilization and freeze-substitution.

Animals↗

Dentine bond strength of a composite resin polymerized with conventional light and argon laser.

The use of argon laser (488 nm) has been suggested as a new alternative for polymerizing adhesive materials. This study aimed to evaluate the tensile bond strength of a microfilled composite (A110, 3M) inserted by incremental technique (3 increments of 1 mm) and by single increment (3 mm) polymerized by argon laser for 10, 20 and 30 seconds and halogen light for 40 seconds. Eighty (8 groups of 10 teeth) freshly extracted bovine teeth were stored in a freezer in distilled water for one week. The crowns were cross-sectioned from the roots. Pulpectomy was performed and the pulp chambers were sealed with wax. The buccal surfaces of the teeth were ground with wet sandpaper (grains: 120, 400, and 600) to expose the surface dentin, and the teeth were then included in acrylic resin. A metal device was used to fix each sample and a black propylene matrix25 (3 mm high with an internal millimetric delimitation) was used to insert the material according to the groups studied. The polymerization intervals were of 10, 20 and 30 seconds for the laser polymerization and 40 seconds for the conventional polymerization. Tensile tests were performed by a Universal Testing Machine 4442 (Instron) at a speed of 0.5 mm/min and 500 N load. According to the methodology used, the incremental technique increased bond strength values. There was no difference between the studied polymerization techniques when resin was filled in 3 increments.

Animals↗

Resin-modified glass ionomer restorations in primary molars: a comparison of three in vitro procedures.

In recent years, interest in the use of glass ionomer cements as a restorative material has been increased. The aim of this in vitro study was to evaluate the microleakage of a glass ionomer restorative material (Vitremer TM) in Class V cavities of primary molars using three different application procedures. The experimental material consisted of 24 freshly extracted human primary molars in which a standardized class V cavities were prepared and restored with Vitremer utilizing three different application procedures (Vitremer with conditioner, with conditioner and primer or with primer). Teeth were covered with green stick compound and nail polish except approximately 1 mm from the class V cavities margins. Later, teeth were immersed in 5% methylene blue for 4 hours, rinsed with water and embedded in acrylic resin. The marginal microleakage was assessed according to the degree of dye penetration of the occlusal and cervical margins. The results showed no significant difference between the three different application procedures. However, the occlusal margin microleakage was significantly higher than the cervical margin (P = 0.0079). It was concluded that using different application procedures of Vitremer, including the recommendations of the manufacturer does not affect microleakage of class V cavities in primary molars.

Composite Resins↗

[Use of a retainer bar in lower full dentures].

In subtotal mandibular edentations, the roots of remaining anterior teeth might be used to enhance the retention of a full denture in building a contramucosal retention bar. Based on a case-report, the authors present the fabrication in five clinical and laboratory sequences, of a maxillary full denture combined with a lower full denture and a retainer bar joining two cuspids. First sequence: Clinical. It mainly concerns: 1) Preparation and impression of the two cuspids for receiving the two posts on which the retention bar will be fixed. 2) The primary plaster impression of the soft tissues. In the laboratory, the coping are directly cast with gold without a core, topped with resin. The individual mandibular impression tray (IIT) presents two windows opposite the two preparations through which the tops of the two copings are showing. Second sequence: Clinical. If the maxillary impression is a classical one, the mandibular impression is peculiar and original. Overall, this provides a reliable working model on which the dental technician will be able to build, the entire prosthesis, not only the retainer bar but also the full denture. This is done in two stages: 1) Secondary impression of the soft tissues with copings in place. 2) Indexing of the copings to the impression tray with acrylic resin, pressing firmly on the rims of the IIT and simultaneously, on the tops of the copings to take into account the different depression of the tissues. In the laboratory, both impressions are boxed and cast, with in place.(ABSTRACT TRUNCATED AT 250 WORDS)

Dental Abutments↗

Modification of glass fibers to improve reinforcement: a plasma polymerization technique.

OBJECTIVES: This study evaluates the effect of plasma treated E-glass fiber to improve the mechanical properties of acrylic resin denture base material, polymethylmethacrlyate (PMMA). Plasma surface treatment of fibers is used as reinforcement in composite materials to modify the chemical and physical properties of their surfaces with tailored fiber-matrix bonding strength. METHODS: Three different types of monomer 2-hydroxyethyl methacrylate (HEMA), triethyleneglycoldimethylether (TEGDME) and ethylenediamine (EDA) were used in the plasma polymerization modification of glass fibers. A radiofrequency generator was used to sustain plasma in a glass vacuum chamber. Glass fibers were modified at the same glow-discharge power of 25 W and exposure time of 30 min for each monomer. Fibers were incorporated into the acrylic with 1% (w/w) loading except control group. Specimens were prepared using a standard mold of 3 cmx0.5 cmx0.8 cm in dimension with eight specimens in each group. Samples were subjected to a flexural strength test set up at a crosshead speed of 5mm/min. Scanning electron microscopy (SEM) was used to examine the microstructure and X-ray photoelectron spectroscopy (XPS) was used for chemical analysis of the surface. RESULTS: Data were analyzed by means of ANOVA and Duncan's tests. Test results revealed that fiber reinforcement had a significant effect on the flexural strength of the specimens (p<0.05). Among the fiber reinforced groups, plasma treatment with EDA monomer resulted in the most significant increase in flexural strength values (p<0.05). XPS results have shown an increasing number of nitrogenous compounds in EDA treated fibers. The chemical structure of the surface, especially with the increase in nitrogenous compounds could give an idea for the amine film deposition and SEM figures showed an increase in surface roughness. SIGNIFICANCE: The results showed that plasma treatment with EDA monomer was an effective alternative method of increasing the flexural strength of PMMA based denture base polymers through fiber reinforcement.

Analysis of Variance↗

Effects of two methods of moisture control on marginal microleakage between resin composite and etched enamel: a clinical study.

Visible light-polymerized resin composite tabs were bonded to the flattened, acid-etched surface of teeth that were scheduled for extraction. Half of the teeth (group I) were isolated with cotton rolls in conjunction with a saliva ejector. The remaining teeth (group II) were isolated using a rubber dam. Both methods of isolation were used for each patient so that to some extent all patients served as their own controls. Following extraction, all samples were thermocycled 500 times alternating between 6 degrees C and 60 degrees C, after which they were immersed in 5% methylene blue for 4 hours. Each tooth was then mounted in acrylic resin and sectioned on a hard tissue microtome. Microleakage was assessed using a light microscope at x 20 magnification. The use of rubber dam isolation resulted in less microleakage at the enamel resin interface.

Composite Resins↗

Effect of high-powered LED polymerization on the shear bond strength of a light-polymerized resin luting agent to ceramic and dentin.

STATEMENT OF PROBLEM: A newly introduced high-powered light-emitting diode (LED) light-polymerization unit with various polymerization modes is purported to polymerize dental resins more quickly than standard units. However, there is insufficient information about the effects of this type of light source and its polymerization modes on resin luting agents (RLAs). PURPOSE: This in vitro study evaluated the effects of different modes of a high-powered LED polymerization unit on the shear bond strength of a light-polymerized RLA to ceramic and dentin. MATERIAL AND METHODS: Sixty ceramic cylinders (3 x 3 mm) were fabricated from a heat-pressed ceramic (IPS Empress 2). Specimen surfaces were abraded using 600-grit silicon carbide paper and airborne-particle abraded with 50-mum desiccant alumina particles, cleaned ultrasonically, etched using hydrofluoric acid, and treated with a silane coupling agent (Ceramic primer). Sixty noncarious, freshly extracted, permanent human molar teeth were embedded in autopolymerizing acrylic resin, and their dentin surfaces were wet-ground using a grinding and polishing machine fitted with 180-grit abrasive disks. The ground dentin surfaces were then etched with 37% phosphoric acid gel, and an adhesive agent (Single Bond) was applied. Ceramic specimens (n = 15) were bonded to dentin surfaces with a dual-initiated RLA (Rely-X ARC) and individually polymerized by 1 of 4 different modes, as follows: Halogen standard mode (Control) (600 mW/cm2 for 40 seconds); high-powered LED fast mode (1100 mW/cm2 for 10 seconds); high-powered LED pulse mode (1100 mW/cm2 for 10 seconds); and high-powered LED exponential mode (1100 mW/cm2 for 20 seconds). Cemented specimens were subjected to shear loading until fracture using a universal testing machine. A stereomicroscope (x25) was used to identify the mode of fracture. Bond strength (MPa) data were analyzed using 1-way analysis of variance and the Tukey HSD test (alpha = .05). RESULTS: Specimens polymerized using halogen standard mode (23.9 +/- 1.3 MPa) and LED exponential mode (23.0 +/- 1.1 MPa) had significantly higher ( P < .001) mean shear bond strengths compared with both LED fast (15.1 +/- 1.3 MPa) and pulse (14.6 +/- 1.3 MPa) modes. The Tukey HSD tests showed no significant differences in shear bond strength between specimens polymerized using high-powered LED exponential mode and halogen standard mode. Most failures were adhesive failures at the dentin-RLA interface or the RLA-ceramic interface in specimens polymerized using high-powered LED fast or pulse modes. CONCLUSION: Within the limitations of this study, the shear bond strength of an RLA to ceramic and dentin was found to be similar when polymerized using halogen light in standard mode and high-powered LED light in exponential mode, whereas shear bond strength was significantly lower when polymerized using LED in fast or pulse mode.

Analysis of Variance↗

A comparison of the adhesion of three restorative materials.

This study compared the adhesion of three different composite restoration resins. For this investigation, 45 extracted lower wisdom molars were selected and 45 Class I cavities were prepared by the same operator, and were randomly divided into three groups of 15 samples each. GROUP A: the molars of this group were filled with Surefil and the adhesive used was Prime & Bond NT. GROUP B: the molars of this group were filled with Prodigy Condensable and the adhesive used was Optibond Solo. GROUP C: for the molars of this group, Enamel Plus was used as composite and Prime & Bond NT was used as adhesive. As a negative control, twenty teeth were used without Class I preparations. Teeth were embedded in cold-cure acrylic resin and sectioned longitudinally. Dye penetration at the enamel and dentin margins were scored at 30 x magnification. Evaluations were rated from 0 to 3 (0 = no leakage; 1 = dye penetration up to one-half of the preparation depth; 2 = dye penetration more than one-half of preparation depth, but less than the axial wall; 3 = dye penetration along the axial wall). All the samples were analyzed with SEM at the following magnifications: 80 x (I micrograph), 220 and 740 x (II micrograph), 1200 x and 4200 x (III micrograph). The samples of Groups B and C showed no dye penetration. The samples of Group A showed either a level 2 or a level 3 dye penetration.

Adhesiveness↗

Epoxy-embedded versus nonembedded TEM examination of the resin-dentin interface.

When transmission electron microscopy (TEM) is used to evaluate resin-dentin interface specimens for completeness of hybridization, the epoxy resin embedding medium that normally facilitates ultrathin sectioning may produce a secondary or artifactual hybrid layer. This secondary hybrid layer, composed of epoxy resin rather than adhesive resin, may fill the pores that remain as evidence of incomplete resin infiltration, obscuring the fact that they ever existed. In this study, resin-dentin interfaces produced by two dentin adhesive systems, Optibond (OPTI, Kerr) and Scotchbond Multi-Purpose (SBMP, 3M), were comparatively investigated by TEM in epoxy-embedded and nonembedded nondemineralized sections. The hypothesis advanced was that no difference in ultramorphology of the hybrid layer would result from either specimen preparation method. The two adhesive systems were applied to four mid-coronal dentin disks per manufacturer's instructions. One half of each sample was processed following common procedures for TEM sample preparation with epoxy embedding, whereas the other half was not embedded but instead immersed in hexamethyldisilazane (HMDS), dried and mounted so that it protruded from a base of cold-cure acrylic resin. Each sample was then sectioned using a diamond knife in an ultramicrotome. With either means of preparation, a hybrid layer with a relatively uniform electron density and a loose collagen fibril arrangement with electron lucent interfibrillar channels was formed by OPTI. At the base of the hybrid layer, collagen fibrils were anchored in the underlying unaffected dentin, and no microporosities or gaps were observed. Similarly, whether SBMP was embedded or nonembedded, it was found to have a hybrid layer of variable electron density and an electron dense phase localized at the surface of the hybrid layer. No porosities were evident at the base of the hybrid layer. Thus, with either of the two adhesive systems, no ultrastructural difference in hybrid layer formation was observed between epoxy-embedded and nonembedded sections, and no direct evidence of ineffective resin-infiltration of the demineralized collagen scaffold was found.

Acid Etching, Dental↗

Influence of self-etching primer on the resin adhesion to enamel and dentin.

PURPOSE: To evaluate the shear bond strength of resin-based composite to dentin and enamel using three adhesive systems, two of them containing self-etchant primers. Wettability (contact angle measurements) of the primers of these three adhesive systems was also evaluated on superficial and deep dentin. MATERIAL AND METHODS: Contact angle measurements were performed on 30 caries-free extracted human third molars; specimens were sectioned parallel to the occlusal surface to expose superficial and deep dentin. Dentin was ground flat (600-grit SiC) under water to provide uniform surfaces. Contact angle measurements were performed to assess wettability using the Axisymmetric Drop Shape Analysis technique. In order to test the enamel bond strength, 30 extracted bovine incisors were embedded in acrylic resin and ground flat to 800-grit. The adhesives and composite resins were applied following the manufacturers' instructions. All the specimens were stored in water for 24 hrs at 37 degrees C and thermocycled (500x). Shear bond strengths were determined using a universal testing machine and the Watanabe device. For dentin bond strength testing, superficial and deep dentin was exposed in 60 third molars, by sectioning the occlusal surface immediately under the enamel-dentin junction or close to the pulp chamber. After grinding (500 grit SiC), the dentin surfaces were assigned to three groups: (1) Clearfil SE Bond (CSEB)/Clearfil AP-X resin composite. (2) Etch & Prime (E&P)/Degufill mineral resin composite. (3) Scotchbond Multi-Purpose Plus (SBMP)/Z100 resin composite. RESULTS: One-way ANOVA and Student-Newman-Keuls multiple comparisons tests showed that no differences were found between contact angles on superficial and deep dentin. CSEB and E&P, without significant differences between them, had greater mean contact angle than SBMP. On enamel, Etch & Prime resulted in the lowest bond strength, but no significant differences existed with Scotchbond Multi-Purpose were found. On dentin, Clearfil SE Bond resulted in the significantly highest bond strength; no significant differences exist between Etch & Prime and Scotchbond Multi-Purpose.

Acid Etching, Dental↗

Preparation of controlled-release microspheres of ibuprofen with acrylic polymers by a novel quasi-emulsion solvent diffusion method.

A novel quasi-emulsion solvent diffusion method to prepare the controlled-release microspheres of ibuprofen with acrylic polymers has been developed. An ethanol solution of ibuprofen and acrylic resin was poured into aqueous medium with stirring. The finely dispersed ethanolic droplet-like coacervates formed in aqueous medium were gradually solidified and transformed into microspheres during agitation. The size of microspheres was determined by the concentrations of drug and polymer and the agitation speed of the system. The flowability, the packability, and the compressibility of the resultant microspheres were much improved compared with the raw crystals of the drug. The drug release rate from the microspheres could be controlled by the type and the concentration of polymer formulated. A unique principle of the present method and the resultant microspheres, having a matrix- or sponge-like texture, can provide characteristic advantages compared with a conventional reservoir-type device drug, like a microcapsule.

Acrylates↗

Influence of dietary simulating solvents on the hardness of provisional restorative materials.

OBJECTIVE: To evaluate the influence of dietary simulating solvents on surface hardness of chemical, light and dual-cure provisional restorative materials. METHODS: The provisional materials evaluated were Temporary Bridge Resin (TBR) (Dentsply), Protemp Garant (PG) (ESPE-3M), Luxatemp Automix (LA) (DMG), Unifast LC (UF) (GC), Luxatemp Solar Plus (LS) (DMG) and Provipoint DC (PP) (Vivadent). Materials were manipulated according to manufacturers' instructions and placed in customized molds. Immediately after setting/light-polymerization, the materials were stored in the following dietary simulating solvents at 37 degrees C for 1 week: (a) heptane, (b) 100% ethanol solution (ES), (c) 75% ES, (d) 50% ES, (e) 25% ES, and (f) distilled water. Specimens stored in air were used as control. After the one-week conditioning period, hardness testing (KHN; n = 6) was carried out with a digital microhardness tester (load=100 gf; dwell time=15 s). Hardness ratios were plotted against the solubility parameter of the solvents and the Environmental Index was subsequently computed. Data were subjected to ANOVA/Scheffe's test at significance level 0.05. RESULTS: For all materials, conditioning in the various ES resulted in significantly lower KHN values compared to conditioning in air and water. TBR, UF and PP were also significantly softened by conditioning in heptane. Ranking of Environmental Index was as follows: LS>LA>PG>TBR>UF>PP. SIGNIFICANCE: All provisional materials were significantly softened by aqueous ethanol solutions. Materials based on bis-acryl resins were generally more resistant to damage from dietary solvents.

Composite Resins↗

Ultrastructural immunocytochemistry of glia cells. Double labeling studies using LR White embedding and colloidal gold.

The introduction of acrylate resins (Lowicryl K4M, LR White) into electronmicroscopic immunocytochemistry applied to embedded tissue (post-embedding method) has improved the localization of antigens because of a satisfactory preservation of both ultrastructure and antigenicity of tissues. Here we describe a method that allows double staining of intracellular and membranous determinants in ultrathin sections of nervous tissue and cultures of peripheral nervous system cells. Ultrathin sections of the rat central nervous system fixed on uncoated grids were stained first for MBP selectively on the one face, then the opposite face was stained for GFAP using monoclonal antibodies and indirect immunogold staining method (IGS). Cultured Schwann cells induced to express major histocompatibility complex (MHC) class II antigens were stained for class II antigens by pre-embedding method then followed by post-embedding IGS for the other intracytoplasmic antigens.

Acrylates↗

Refine your search to explore more results.