Search PubMedSearch

SEARCH · Search PubMed

Results for “technology- or image-based abuse”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,206 records · Page 10Linked to original sources

Development and validation of an LC-MS/MS method for the quantification of the KRASG12C inhibitor divarasib.

Divarasib is a newly developed covalent KRASG12C inhibitor, currently under clinical investigation in a phase 3 trial in patients with non-small cell lung cancer (NSCLC). At the moment, very limited pharmacokinetic data are publicly known. However, obtaining more insight into the pharmacokinetic properties of divarasib is important, since this may provide a better understanding of its efficacy and safety risks. Pre-clinical studies have been performed in mouse models to evaluate the effect of drug transporters and drug-metabolizing enzymes on the plasma exposure and tissue distribution of divarasib. Therefore, a reliable quantification method is required. To our knowledge, no bioanalytical assay of divarasib has been published yet. Therefore, in this study we developed and validated an assay to quantify divarasib in human plasma and in eight different mouse-related matrices, and partially in mouse plasma, using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The method was initially evaluated over a concentration range of 1-10,000 nM. However, due to carry-over observed at 10,000 nM, the validated calibration range was established at 1-2000 nM, with matrix-dependent LLOQs of 1-10 nM. Erlotinib was used as an internal standard and acetonitrile was utilized to perform protein precipitation as sample pretreatment. Divarasib demonstrated stability in human plasma and in mouse plasma and tissue homogenates under various experimental conditions. A pilot in vivo study showed the applicability of our validated LC-MS/MS method. Ongoing clinical trials may collect plasma samples, and this developed method enables quantification of divarasib in both mouse and human plasma samples.

Animals

PCa Detection in PI-RADS 4 and 5 Lesions: Comparison of [68Ga]Ga-PSMA-11 PET/CT-Guided Robot-Assisted Biopsy Versus mpMRI Cognitive-Fusion TRUS-Guided Prostate Biopsy.

Lesions with a Prostate Imaging-Reporting and Data System (PI-RADS) score of 4 or greater on multiparametric MRI (mpMRI) indicate a high likelihood of prostate cancer (PCa), and guidelines recommend a targeted biopsy. We aimed to compare the diagnostic performance of robotic arm-assisted [68Ga]Ga-PSMA-11 PET/CT-guided prostate biopsy (PGPB) with mpMRI-directed cognitive-fusion transrectal ultrasound-guided biopsy (MCFB) in biopsy-na&#xef;ve men with clinical findings suggestive of PCa. Methods: This prospective, single-center, randomized clinical trial (NCT05137561) enrolled biopsy-na&#xef;ve men age 50-90 y with elevated levels of prostate-specific antigen (&#x2265;4 ng/mL) and abnormal digital rectal examination findings. All participants underwent mpMRI, and those with a PI-RADS score of 4 or greater were randomized into 2 arms. In arm 1, participants underwent PGPB for a [68Ga]Ga-PSMA-avid lesion, and participants in arm 2 underwent MCFB. Participants in arm 1 with PET-negative findings subsequently underwent MCFB, and participants with negative biopsy results underwent PET and PGPB. The primary outcome was the detection of PCa. Secondary outcomes included complication rates and participant-reported pain. Result: Of the 267 participants enrolled, 81.3% (217) had lesions with a PI-RADS score of 4 or greater and were randomized to either PGPB (n = 112) or MCFB (n = 105). PCa was detected in 97.1% of participants (101/104) in arm 1 and 81.0% (85/105) in arm 2 (P < 0.05). PGPB showed higher diagnostic accuracy for PI-RADS 5 lesions (100% vs. 95.1%, P = 0.09). Major complications were observed in arm 2 only (n = 5). Arm 1 had significantly fewer complications (10.8% vs. 51.4%, P < 0.01), a lower median visual analog scale score for pain (3 vs. 5), and shorter procedure times. The core positivity rate was higher in arm 1 (60% &#xb1; 20%), despite obtaining fewer cores. Conclusion: [68Ga]Ga-PSMA-11 PGPB demonstrated higher diagnostic performance, fewer complications, and better tolerability compared with MCFB. This approach enables integrated diagnosis and staging, offering a promising alternative for efficient, safe, and accurate evaluation of prostate cancer.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

Angiotensin II regulates anxiety and social-affective top-down and bottom-up attention control in a sex-dependent manner.

BACKGROUND: The renin-angiotensin system (RAS) has been increasingly recognized as potent modulator of cognitive and affective functions, with angiotensin II type 1 receptor (AT1R) antagonists emerging as repurposing candidate for anxiety and stress-related disorders. However, it remains unclear whether transient AT1R blockade modulates emotional attentional control and whether these effects are sex-dependent. METHODS: We conducted a preregistered, randomized, double-blind, placebo-controlled pharmacological eye-tracking study in 79 healthy adults (males and females) and determined effects of transient AT1R blockade via losartan (50&#xa0;mg) on emotional attention control using a validated anti-saccade paradigm with social (emotional faces) and non-social stimuli. Treatment effects on state anxiety and oculomotor responses were characterized using traditional metrics and a novel trial-history informed dynamic control framework. RESULTS: Losartan reduced state anxiety irrespective of sex but induced sexually dimorphic effects on attentional control. In females, losartan enhanced performance by reducing endpoint error without altering latency. Conversely, in males, losartan increased endpoint error and prolonged latency of the first correct saccade. Trial-history analyses revealed losartan reduced error probabilities following errors and repeat trials in both sexes. Yet, following correct trials, females receiving losartan maintained lower error probabilities, while males exhibited higher errors, potentially reflecting failure to disengage from effortful control. CONCLUSIONS: The RAS modulates anxiety and attentional control, the latter sex-dependently. AT1R blockade reconfigures attentional processing and adaptive control, suggesting sex-specific therapeutic potential in disorders characterized by excessive anxiety and attentional dysregulation. CLINICAL TRIALS REGISTRATION: ClinicalTrials.gov; https://clinicaltrials.gov/;NCT06329050.

Humans

Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of twenty-five steroids in equine serum.

Steroids are potential biomarkers for monitoring equine pregnancy. However, immunoassays currently used for their quantification suffer from cross-reactivity and limited specificity, thus requiring more accurate methods. This study reports the development and validation of a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of 25 steroids covering the main biosynthetic pathways of progestogens, corticosteroids, androgens, and estrogens. Steroids were extracted by protein precipitation followed by evaporation, derivatization, and reconstitution before LC-MS/MS analysis. A surrogate matrix was used for calibration and validation to avoid endogenous interference. Validation was performed according to and partly adapted from Clinical and Laboratory Standards Institute guidelines (CLSI), including linearity, trueness, precision, limits of detection and quantification, measurement uncertainty, recovery, matrix effects, carryover, selectivity, and stability. Calibration curves were fitted using the best-performing weighted linear or quadratic regression model, yielding excellent linearity (R2&#xa0;>&#xa0;0.990), trueness between -9.0% and 2.3%, and intra- and inter-day precision <6.3%. Lower limits of quantification ranged from 2.07 to 2250&#xa0;pg/mL depending on physiological analytes concentration. Extraction recovery averaged 24.3-114.9%, matrix effects were acceptable, and accuracy ranged from 94.4% to 98.9%. No carryover or interferences were detected. Measurement uncertainty remained <15%. This study presents the first LC-MS/MS method partially validated per CLSI criteria for the quantification of 24 steroids in equine serum. The method offers a sensitive and specific alternative to immunoassays and provides a robust tool for equine steroid profiling with potential applications in pregnancy monitoring, placentitis diagnosis, and fetal sex determination.

Animals

Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.

Purpose To compare safety and feasibility between a novel CT-guided robotic system and the conventional freehand technique for puncture biopsy of thoracoabdominal lesions. Materials and Methods In this prospective multicenter randomized trial, individuals with suspected lesions were enrolled between July 2023 and April 2024 across three university teaching hospitals and randomized to the robot-assisted group (n = 82) or the freehand group (n = 83). Procedure outcomes included the technical success rate, targeting error, number of CT scans and needle adjustments, puncture time, and complications. Descriptive and inferential statistics were calculated. Results A total of 165 participants (mean age, 60 years &#xb1; 10 [SD]; 83 male) were included. Compared with the freehand group, the robot-assisted group demonstrated a higher technical success rate (97.56% [80 of 82] vs 62.65% [52 of 83], P < .001), lower targeting error (mean Euclidean deviation: 1.7 mm &#xb1; 1.1 vs 4.5 mm &#xb1; 3.9, P < .001), and fewer CT scans (mean, 4.3 &#xb1; 1.9 vs 5.2 &#xb1; 2.3; P = .002) and needle adjustments (mean, 0.7 &#xb1; 0.7 vs 1.6 &#xb1; 1.6; P = .003). Despite differences in geometric precision, both groups achieved 100% (82 of 82 and 83 of 83) diagnostic yield. The median puncture time was comparable between groups (5.5 minutes &#xb1; 4.3 vs 4.8 minutes &#xb1; 7.0, P = .50). During lung biopsies, the robot-assisted approach yielded fewer complications compared with the freehand approach (4.88% [four of 82] vs 16.87% [14 of 83], P = .014). Conclusion Compared with the freehand approach, robot-assisted biopsy yielded greater precision and reduced adjustments and complications while demonstrating noninferior diagnostic efficacy and comparable duration. Keywords: Robotic Needle Insertion, Biopsy, Thoracoabdominal Lesions, Robot-assisted Biopsy, CT-guided Intervention, Percutaneous Needle Biopsy, Randomized Controlled Trial, Algorithm Development, CT, Clinical Testing, Interventional-Body, Biopsy/Needle Aspiration, Percutaneous, Thorax, Abdomen/GI, Liver, Lung, Kidney &#xa9;RSNA, 2026.

Humans

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20&#xa0;ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r&#xa0;=&#xa0;0.926). PFOS was the only compound detected at concentrations &#x2265;0.2&#xa0;ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50&#xa0;ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Clinical Utility of Ultra-Widefield Swept-Source OCT for Intraocular Tumors: Comparison With Ultrasonography, SD-OCT, and MRI.

PURPOSE: To evaluate the clinical performance of ultra-widefield swept-source optical coherence tomography (UWF-OCT) in the assessment of choroidal tumors and to compare it with ultrasonography (US), spectral-domain (SD)-OCT, and magnetic resonance imaging (MRI). DESIGN: Retrospective diagnostic comparison. SUBJECTS: Thirty-nine eyes from 39 patients diagnosed with choroidal tumors at a single tertiary referral center. METHODS: This retrospective diagnostic comparison evaluated patients diagnosed with choroidal tumors at a single tertiary referral center between January 2023 and August 2025. All patients underwent UWF-OCT imaging at diagnosis. Tumor measurements obtained with UWF-OCT were compared with US, SD-OCT, and MRI. Comparative analysis among imaging modalities and predictors affecting UWF-OCT applicability was performed. MAIN OUTCOME MEASURES: Tumor thickness (mm) and largest basal diameter (LBD, mm) measurements, and complete measurability rate across different tumor size categories. RESULTS: Thirty-nine eyes from 39 patients (mean age 59.2 &#xb1; 16.9 years) were analyzed, including 27 choroidal melanomas (69.2%), 5 metastatic tumors (12.8%), 4 hemangiomas (10.3%), 2 osteomas (5.1%), and 1 (2.6%) indeterminate choroidal melanocytic lesion. UWF-OCT successfully measured both tumor thickness and largest basal diameter (LBD) in 100% (31/31) of small and medium choroidal tumors, substantially outperforming SD-OCT (complete measurement achieved in 63.6% of small tumors, and 0% of medium or large tumors). UWF-OCT measurements were systematically smaller than ultrasonography (thickness: -32.3%, P < .01; LBD: -11.1%, P < .01) and MRI (thickness: -29.2%, P < .01). Mushroom-shaped tumor morphology was the strongest negative predictor of UWF-OCT quality (OR = 0.015, 95% CI 0.001-0.196, P < .01). UWF-OCT's complete measurability was limited in large tumors (12.5%, 1/8). CONCLUSIONS: UWF-OCT provides precise, noninvasive, single-scan assessment of small-to-medium choroidal tumors with detailed structural visualization. It may be particularly useful for dome-shaped tumors, while multimodal imaging with US and MRI remains optimal for complex morphologies. Overall, UWF-OCT represents a valuable tool for diagnosis and treatment planning, with potential utility for longitudinal follow-up in choroidal tumor management.

Humans

Artificial Intelligence for Diagnosing Meibomian Gland Dysfunction: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy Studies.

PURPOSE: To identify, appraise, and synthesize the performance of artificial intelligence-based meibography reading as compared with human graders in diagnosing meibomian gland dysfunction. METHODS: We followed Cochrane methodology and reporting guidelines for diagnostic test accuracy reviews. To assess potential risk of bias and applicability, we used a modified Quality Assessment of Diagnostic Accuracy Studies-2 checklist. We applied bivariate logistic models to estimate summary sensitivity and specificity when appropriate and used the GRADE framework to rate the certainty of the evidence. RESULTS: We identified 14 eligible studies involving 5511 predominantly middle-aged participants (average age: 27-55 years) who were primarily female (&#x2265;54.5%). A total of 18,926 meibography images were obtained through noncontact infrared (11 studies) or in vivo confocal microscopy (three studies). Two studies reported external validation of deep learning models, 12 reported internally validated models, and one reported both. All but one study had high risk of bias in at least one domain; 12 studies raised high or intermediate concern about applicability. Based on three external evaluations, the summary sensitivity and specificity for diagnosing meibomian gland dysfunction from normal glands were 97.5% (95% confidence interval: 77.5%-99.8%) and 85.5% (95% confidence interval: 47.3%-97.5%). Sources of heterogeneity in internally validated models included study population, case mix, and others. The overall evidence was very low to low certainty because of imprecision, high risk of bias, and concerns about applicability. CONCLUSIONS: Artificial intelligence-based meibography grading appears less accurate than human graders. Future studies should adopt rigorous designs, including a more diverse participant pool (or image set), and external validation.

Humans

Emerging techniques of CRISPR/Cas system in antiviral therapy and diagnostics: Applications, limitations, and translational perspectives.

The CRISPR/Cas (clustered regularly interspaced short palindromic repeats) system is a versatile technology for developing antiviral medicines and editing viral genomes in both diagnostics and vaccine synthesis. Emerging insights into class 2 effectors, such as Cas9, Cas12, and Cas13, which target viral DNA and RNA, have revolutionized vaccines against viruses such as HIV, HPV, HBV, and EBV. Innovative diagnostic techniques such as SHERLOCK, DETECTR, and FELUDA have demonstrated system's diversity and accuracy in detecting the virus markers, supporting clinical decision-making, indicating adaptability and precision of CRISPR. This review critically evaluates CRISPR's role in RNA editing, emphasizing its importance for functional genomics and development of recombinant vaccines. Translational challenges are critically discussed, including off-target effects, delivery limitations, and ethical issues, for which unique approaches such as high-fidelity Cas variants, non-viral delivery systems, and bioethical frameworks are evaluated to address these limitations. This review also covers other social implications, such as accessibility and biosecurity risks, associated with CRISPR technologies Collectively, these advances underscore the transformative potential of CRISPR technologies in shaping next-generation antiviral diagnostics and therapeutics.

CRISPR-Cas Systems

Development and Crossover Evaluation of an Artificial Intelligence-Assisted System for Solid Pancreatic Lesion Detection and Pancreatic Parenchyma Recognition in Endoscopic Ultrasonography (With Video).

BACKGROUND AND STUDY AIMS: Pancreatobiliary endoscopic ultrasonography (EUS) is technically demanding, and supervised training opportunities are limited. We developed an artificial intelligence (AI) overlay system for detecting solid pancreatic lesions (SPL) and recognizing pancreatic parenchyma (PP) and evaluated its effect on reader performance. PATIENTS AND METHODS: Across six centers, two deep learning-based models were trained using expert-annotated EUS frames. We then conducted a randomized, two-sequence, two-period crossover reader study in which eight endosonographers (five novices and three experts) interpreted image sets with and without AI assistance. The primary endpoint was superiority of sensitivity for SPL detection among novices; key secondary endpoints included specificity and PP recognition. RESULTS: From 118 patients, 120 SPL-positive/negative image sets and 160 PP-positive/negative image sets were constructed. Among novices, AI assistance improved SPL detection sensitivity (88.7% vs. 76.8%, p&#x2009;<&#x2009;0.001) and accuracy (86.4% vs. 78.7%), while specificity met the predefined noninferiority criterion (84.2% vs. 80.5%, p&#x2009;<&#x2009;0.001). For PP recognition, sensitivity increased numerically (86.3% vs. 83.3%) but did not meet the predefined superiority criterion (p&#x2009;=&#x2009;0.095); specificity met the noninferiority criterion (87.8% vs. 81.0%), and accuracy increased from 82.1% to 87.0%. Among experts, sensitivity was maintained for both tasks, whereas specificity increased with AI assistance. CONCLUSIONS: AI assistance improved SPL detection among novice endosonographers. For PP recognition, sensitivity increased without reaching statistical superiority, whereas specificity met the predefined noninferiority criterion. These findings support a potential adjunctive role for AI in EUS interpretation.

Humans

E-cigarette product characteristics and packaging features and interest in e-cigarette use: Results from a randomized within-person trial nested in three prospective cohorts.

BACKGROUND: Product characteristics and packaging may be key targets for regulation to reduce e-cigarette use among youth, but existing data are limited. METHODS: Data are from an experimental study (2018-2020) nested within three prospective cohorts (age 14-26) in southern California (N&#x2009;=&#x2009;3565). Participants were shown five e-cigarette (e-liquid) packages in a random order that varied in flavor (sweet vs. tobacco), flavor name (descriptive ["blueberry cheesecake"] vs. concept ["smurf cake"] vs. none [number only]), and cartoon image on package (yes/no). For each stimuli, survey items assessed the following outcomes: product appeal (self-enjoyment, others' enjoyment; Likert scale [1-5]), susceptibility to use (use if friends offered, curiosity; 4 ordered responses [definitely not-definitely yes]), peer acceptability (definitely not-definitely yes), and perceived harm (definitely not-definitely yes). Mixed effects proportional odds models evaluated within-person effects of each factor (flavor, flavor name, cartoon) with each outcome. RESULTS: Participants reported greater appeal, susceptibility, and peer acceptability (OR range=3.7-16.9; ps<0.05), and lower perceived harm (OR=0.61; 95%CI=0.53, 0.70) for sweet (vs. tobacco-flavored) e-cigarettes; effects were progressively stronger for younger cohorts. The descriptive flavor name rated higher than the concept flavor (OR range=1.13-2.02; ps<0.05) or number only (OR range=1.18-1.69; ps<0.05) for appeal and susceptibility measures; no differences for concept vs. number were found. The cartoon image rated higher for appeal, curiosity, and peer acceptability (OR range=1.24-1.51; ps<0.05). CONCLUSIONS: Sweet flavors, descriptive flavor names, and cartoon images may increase the appeal of e-cigarettes among youth and young adults with no history of e-cigarette use, and are key targets for regulation.

Humans

SBUF-SMUF: On the path to the optimum hemofiltration technique in pediatric cardiopulmonary bypass: A randomized clinical trial.

BACKGROUND: Hemofiltration during pediatric cardiopulmonary bypass (CPB) is essential to mitigate hemodilution, inflammatory responses, and postoperative complications. Conventional ultrafiltration (CUF) is widely practiced, but novel methods such as subzero balanced ultrafiltration combined with simple modified ultrafiltration (SBUF-SMUF) may offer superior outcomes. OBJECTIVE: To compare the clinical efficacy and safety of CUF versus SBUF-SMUF in pediatric patients undergoing open-heart surgery. METHODS: In this prospective randomized, outcome-assessor-blinded clinical trial, 80 pediatric patients with congenital heart disease were allocated to either CUF (n = 40) or SBUF-SMUF (n = 40) during CPB. Baseline demographics, intraoperative characteristics, fluid balance, blood product utilization, and postoperative outcomes were assessed. Statistical analysis was conducted using independent t-tests, Chi-square tests, and Fisher's exact tests. Statistical significance was defined as a two-tailed p-Value of less than 0.05. RESULTS: Demographic and preoperative variables were comparable between groups. Mean fluid balance was significantly positive in the CUF group (+192.1 &#xb1; 178.8 mL) but negative in the SBUF-SMUF group (-105.0 &#xb1; 78.9 mL, p < 0.001). The SBUF-SMUF group required significantly less intraoperative PRBC (141.7 &#xb1; 70.2 vs. 261.0 &#xb1; 68.8 mL, p < 0.001) and postoperative FFP transfusion (2% vs. 10%, p = 0.020). Post-bypass hematocrit levels were higher (31.2% vs. 27.3%, p = 0.001) and extubation occurred earlier in the SBUF-SMUF group (1.05 &#xb1; 1.03 vs. 2.27 &#xb1; 2.37 days, p = 0.006). No significant differences were observed in potassium levels or incidence of acute kidney injury. CONCLUSION: The SBUF-SMUF technique is safe, effective, and superior to CUF in optimizing fluid balance, reducing blood product utilization, and facilitating earlier extubation in pediatric cardiac surgery. No additional risk of oliguria or electrolyte imbalance was observed compared to CUF. Its simplicity and reproducibility support its consideration as a standard approach in pediatric CPB.

Humans

Ultrasound protocols used to detect vascular gas emboli in divers: a systematic review.

INTRODUCTION: Venous gas emboli (VGE) detected via ultrasound can be used as a surrogate marker for decompression stress. While Doppler ultrasound is the historical gold standard, two-dimensional (2D) ultrasonography offers advantages for on-site monitoring, including a wider field of view and reduced dependence on noise-free environments. This systematic review evaluates 2D ultrasonography protocols used in decompression research since the 2015 International Meeting on Ultrasound for Diving Research, identifying methodological similarities, differences, and adherence to consensus recommendations. METHODS: A search of PubMed and Scopus identified studies using 2D ultrasound to detect VGE in divers. Inclusion criteria were: (1) use of 2D ultrasound, (2) detection of VGE or monitoring of decompression stress, (3) inclusion of a diver cohort, and (4) publication after 2015. Data extraction focused on VGE scoring systems, ultrasound hardware, measurement protocols, and operator experience. Risk of bias was assessed using ROBINS-I-V2, and compliance with the 2015 consensus recommendations was evaluated. RESULTS: Twenty studies were included. The Eftedal-Brubakk scale was most commonly used (n = 15), with cardiac ultrasound as the primary imaging modality; one study assessed a peripheral vessel. Common shortcomings included post-dive measurements lasting less than two hours, underreporting of operator experience and hardware specifications, limited individual-level data, and inappropriate use of parametric statistics for ordinal bubble grade data. No study fully complied with all consensus recommendations. CONCLUSIONS: This review demonstrates that, although two-dimensional ultrasound is widely used for post-dive VGE assessment, methodological heterogeneity with multiple shortcomings remain. Furthermore, nearly all studies restricted imaging to the heart, thus leaving peripheral vessel assessment largely unexplored.

Embolism, Air

Isometric Exercises for Tendinopathies: A Systematic Literature Review.

PURPOSE: Musculoskeletal disorders are among the most common reasons for medical consultation, with tendinopathies accounting for up to 30% of such presentations. Although exercise remains the cornerstone of management, the most effective modality continues to be debated. Eccentric exercise has long been the mainstay, but the role of isometric exercise in pain modulation and functional recovery remains unclear. This systematic review aims to evaluate the current evidence on the efficacy of isometric exercises in the management of tendinopathies across various anatomic sites. METHODS: A systematic search was conducted in PubMed, MEDLINE, Embase, and the Cochrane Library from inception to August 1, 2025. Eligible studies included randomized controlled trials and prospective or retrospective cohort studies assessing isometric exercise interventions for tendinopathy, with or without comparator groups. Case series and case reports were excluded. Data extracted included participant demographic characteristics, site of tendinopathy, symptom duration, treatment duration, adherence, and outcome measures such as Victorian Institute of Sports Assessment (A, P, or G), visual analog scale, Patient-Specific Functional Scale, 36 item short form health survey (SF-36), and EuroQol 5-Dimension questionnaires. Imaging outcomes (ultrasound or magnetic resonance imaging) were recorded where available. Methodological quality and risk of bias were assessed using the Cochrane Risk of Bias tool in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. FINDINGS: The search identified 304 articles, of which 13 randomized controlled trials met the inclusion criteria, encompassing 336 participants (40% female). Tendinopathy sites included the patellar (n = 4), Achilles (n = 3), lateral elbow (n = 2), rotator cuff (n = 2), wrist extensor (n = 1), and gluteal (n = 1) tendons. Median symptom duration was 23 months (interquartile range, 3-51 months). Intervention periods ranged from a single 45-minute session to 4-month exercise programs. Treatment adherence was high initially (nearly 100%) but declined over time, with 70% of participants in the isometric and 58% in the control (isotonic) groups completing &#x2265;80% of sessions. Pain reduction and functional improvement were statistically significant in only 3 studies. Imaging-based outcomes were inconsistently reported, and study heterogeneity precluded meta-analysis. Overall methodological quality was rated as good in 3 studies and poor in 10. IMPLICATIONS: Current evidence provides limited support for the superiority of isometric exercise in tendinopathy management. Although isometric regimens appear tolerable and may confer short-term analgesic benefits, their long-term efficacy relative to eccentric or isotonic protocols remains uncertain. Future research should prioritize standardized outcome measures, longer follow-up, and uniform diagnostic criteria to strengthen the evidence base for exercise prescription in tendinopathies.

Humans

Urinary Small Extracellular Vesicle DNA as a Biomarker for the Non-Invasive Diagnosis of Bladder Cancer.

Existing diagnostic technologies for bladder cancer (BC) suffer from low sensitivity, low specificity, or a lack of validation. Therefore, validated, non-invasive diagnostic biomarkers with high sensitivity and specificity for early detection of BC are needed to complement and improve upon the limitations of existing diagnostic methods. We used low-pass whole genome sequencing (LP-WGS) technology to detect copy number variations (CNVs) in small extracellular vesicle (sEV) DNA isolated from urine samples of patients. Based on these results, we constructed and validated a diagnostic model to differentiate between benign and malignant bladder lesions. We conducted a receiver operating characteristic analysis and calculated the area under the curve (AUC) to evaluate the performance of the diagnostic model. The urine sEV-DNA LP-WGS data revealed CNV differences between benign and malignant samples. The diagnostic model achieved an AUC of 0.953, a sensitivity of 86.7%, and a specificity of 100% in the training cohort and an AUC of 0.985, a sensitivity of 90%, and a specificity of 100% in the validation cohort. Even at the lowest coverage depth of 0.01X, the performance of the diagnostic model remained relatively robust. Notably, the performance of this diagnostic model surpassed that of the biomarker neuron-specific enolase (sensitivity: 85.7% vs. 64.3%; specificity: 100% vs. 87.5%) and urinary cytology (sensitivity: 100% vs. 66.7%; specificity: 100% vs. 94.1%). Our study demonstrates that urine sEV-DNA exhibits high discriminatory power in distinguishing between benign and malignant bladder lesions, making it a promising tool for auxiliary diagnosis of BC.

Humans

'Sawa Aqwa' (Stronger Together): A multi-site randomized controlled trial of a brief family systemic intervention for adolescent mental health in Lebanon.

BACKGROUND: There are no evaluated family-based mental health and psychosocial support (MHPSS) interventions for adolescents in Southwest Asia (known as the Middle East), and few whole-family interventions in low- and middle-income countries, despite consistent evidence for the impact of family support on mental health and well-being. This study aims to evaluate the effectiveness of a brief family systemic mental health intervention, deliverable by non-specialists in mental health. METHODS: We conducted an assessor-blind type I hybrid effectiveness-implementation multi-site randomized controlled trial comparing the locally developed family intervention to a waitlist control group for randomly allocated families residing in North Lebanon and Beqa'a governorates. Eligible families presented with medium-to-high risk for child protection concerns (abuse, neglect, child labor, early marriage) and had at least one adolescent aged 12-17 who demonstrated psychological distress. Outcomes at the family, caregiver, and adolescent level were measured pre- and post-intervention, and at 3-month follow-up. RESULTS: Intent-to-treat analyses found a significant between-group effect of the intervention on adolescent-reported family functioning, caregiver mental health, and parenting. No change was found for adolescent psychological distress. Further analyses found effects on adolescent well-being for those who completed the intervention, and that father attendance was associated with better outcomes for adolescent well-being in the intervention group. No other significant moderators were found. At the 3-month follow-up for the intervention condition, family functioning and caregiver well-being significantly dropped from endline. CONCLUSIONS: The study demonstrates mixed results for a non-specialist-delivered family-systemic intervention developed in the context of humanitarian crises in Lebanon. While the intervention did not result in benefits in adolescent-reported symptoms of psychological distress, the intervention group did show greater improvements than the control group on a number of other outcomes, showing the potential impact of working with the wider family system to support adolescents in humanitarian settings.

Humans

Orbital involvement in sickle cell disease: A systematic review.

Orbital involvement in sickle cell disease (SCD) is rare but potentially vision-threatening and is often misdiagnosed due to overlap with infectious orbital disease. We conducted a systematic review of case reports and series describing orbital complications in patients with confirmed SCD, following PRISMA and MOOSE guidelines. Across 53 studies, 76 cases were identified. Patients were predominantly male (77.6%), with an average age of 13.2 years. Orbital disease was the initial SCD manifestation in 6.6%. Presentations included periorbital edema in all, proptosis in 64.1%, restricted ocular motility in 56.5%, reduced visual acuity in 28.1%, and bilateral involvement in 38.2%. Laboratory findings commonly included leukocytosis (73%) and raised inflammatory markers (86.7%). Radiologically, orbital subperiosteal hematoma were observed in 70%, combined orbital bone infarction and hematoma in 38.2%, and orbital bone infarction alone in 19.7%. Magnetic resonance imaging is critical for accurate diagnosis. Intracranial hemorrhage was present in 9.2%. Less frequent manifestations included orbital apex syndrome, lacrimal gland disease, and nonspecific soft tissue swelling. Management was primarily conservative (82.9%), and surgery was reserved for vision-threatening or intracranial complications. Complete recovery was achieved in 93.1% of cases. While severe vision-threatening complications are uncommon, early recognition remains critical to optimising outcomes in sickle cell orbitopathy.

Humans