Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Towards knowledge-based retrieval of medical images. The role of semantic indexing, image content representation and knowledge-based retrieval.

Medicine is increasingly image-intensive. The central importance of imaging technologies such as computerized tomography and magnetic resonance imaging in clinical decision making, combined with the trend to store many "traditional" clinical images such as conventional radiographs, microscopic pathology and dermatology images in digital format present both challenges and an opportunities for the designers of clinical information systems. The emergence of Multimedia Electronic Medical Record Systems (MEMRS), architectures that integrate medical images with text-based clinical data, will further hasten this trend. The development of these systems, storing a large and diverse set of medical images, suggests that in the future MEMRS will become important digital libraries supporting patient care, research and education. The representation and retrieval of clinical images within these systems is problematic as conventional database architectures and information retrieval models have, until recently, focused largely on text-based data. Medical imaging data differs in many ways from text-based medical data but perhaps the most important difference is that the information contained within imaging data is fundamentally knowledge-based. New representational and retrieval models for clinical images will be required to address this issue. Within the Image Engine multimedia medical record system project at the University of Pittsburgh we are evolving an approach to representation and retrieval of medical images which combines semantic indexing using the UMLS Metathesuarus, image content-based representation and knowledge-based image analysis.

Abstracting and Indexing↗

Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging.

PURPOSE: To compare periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) multishot fast spin-echo diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar diffusion-weighted MR imaging for image quality and visualization of acute cerebral infarction. MATERIALS AND METHODS: Seventy subjects (35 men, 35 women; mean age, 55 years +/- 24 [SD]) who were suspected of having acute cerebral infarction (symptom duration, 2.8 days +/- 2.7) underwent PROPELLER and echo-planar MR imaging (b = 1,000 sec/mm(2)). Two neuroradiologists compared unlabeled images for presence of artifacts, visualization of infarction, and their preference of images. Interobserver agreement and image comparison were assessed by using the kappa statistic and the chi(2) test, respectively. RESULTS: PROPELLER MR imaging reduced susceptibility artifacts (n = 70 subjects), which limited visualization of temporal (echo-planar, n = 64; PROPELLER, n = 0; P <.01, chi(2) test), frontal (echo-planar, n = 58; PROPELLER, n = 1; P <.01), and parietal lobes (echo-planar, n = 5; PROPELLER, n = 0; P <.05) and cerebellum (echo-planar, n = 36; PROPELLER, n = 0; P <.01) and brainstem (echo-planar, n = 23; PROPELLER, n = 0; P <.01). Acute infarction (n = 31 subjects) was better demonstrated at PROPELLER MR imaging (PROPELLER better, n = 18; echo-planar better, n = 1; PROPELLER and echo-planar equal, n = 12; P <.01, chi(2) test). PROPELLER MR imaging was preferred in all (n = 70) but one case in which the lesion lay within the intersection gap (PROPELLER preferred, n = 69; echo-planar preferred, n = 1; P <.01, chi(2) test). CONCLUSION: With a short increase in imaging time, PROPELLER MR imaging offers better image quality and detection of acute cerebral infarction than does echo-planar MR imaging.

Acute Disease↗

Breast lesions: evaluation with dynamic contrast-enhanced T1-weighted MR imaging and with T2*-weighted first-pass perfusion MR imaging.

PURPOSE: To evaluate the diagnostic value of an imaging protocol that combines dynamic contrast-enhanced T1-weighted magnetic resonance (MR) imaging and T2*-weighted first-pass perfusion imaging in patients with breast tumors and to determine if T2*-weighted imaging can provide additional diagnostic information to that obtained with T1-weighted imaging. MATERIALS AND METHODS: One hundred thirty patients with breast tumors underwent MR imaging with dynamic contrast-enhanced T1-weighted imaging of the entire breast, which was followed immediately with single-section, T2*-weighted imaging of the tumor. RESULTS: With T2*-weighted perfusion imaging, 57 of 72 carcinomas but only four of 58 benign lesions had a signal intensity loss of 20% or more during the first pass, for a sensitivity of 79% and a specificity of 93%. With dynamic contrast-enhanced T1-weighted imaging, 64 carcinomas and 19 benign lesions showed a signal intensity increase of 90% or more in the first image obtained after the administration of contrast material, for a sensitivity of 89% and a specificity of 67%. CONCLUSION: T2*-weighted first-pass perfusion imaging can help differentiate between benign and malignant breast lesions with a high level of specificity. The combination of T1-weighted and T2*-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

Adult↗

Improved endocardial visualization with second harmonic imaging compared with fundamental two-dimensional echocardiographic imaging.

BACKGROUND: Endocardial visualization is suboptimal by fundamental imaging in at least 30% of patients. Second harmonic imaging was developed for visualization of myocardial contrast agents. We have hypothesized that endocardial visualization may improve with harmonic imaging compared with fundamental imaging. METHODS AND RESULTS: Accordingly, 40 consecutive patients with poor endocardial visualization by conventional echocardiography in at least 1 left ventricular segment (22-segment model) in the 4 standard views randomly underwent fundamental and harmonic imaging without contrast. The images were separately and randomly analyzed by 2 observers. Endocardial visualization was scored as 0, not visualized; 1, poorly visible; and 2, well visualized. Endocardial visualization indexes were also calculated. More segments were assigned a score of 0 (P <. 001) and 1 (P <.001) by fundamental compared with harmonic imaging, whereas harmonic imaging demonstrated more segments with a score of 2 (P <.001) compared with fundamental imaging. Endocardial visualization indexes were significantly better by harmonic imaging in the parasternal long axis (P <.005), short axis (P <.001), and apical 4- (P <.0001) and 2-chamber views (P <.0001). Similar results were obtained by a second observer. Agreement between the 2 observers regarding improvement, deterioration, or no change in score between harmonic and fundamental imaging was 88% (kappa = 0. 76). Interobserver and intraobserver agreements for systolic wall thickening scores also significantly improved with harmonic compared with fundamental imaging (P <.001). CONCLUSION: Second harmonic imaging is superior to fundamental imaging for endocardial visualization in patients with suboptimal fundamental imaging.

Coronary Disease↗

JPEG2000 compression of thin-section CT images of the lung: effect of compression ratio on image quality.

PURPOSE: To assess retrospectively the effect of the Joint Photographic Experts Group 2000 (JPEG2000) compression ratio on the quality of thin-section computed tomographic (CT) images. MATERIALS AND METHODS: In this institutional review board-approved investigation (protocol 238/2004), thin-section CT images were subjected to irreversible JPEG2000 compression by using five compression ratios (3:1, 5:1, 7:1, 9:1, and 11:1). Three radiologists independently evaluated 60 thin-section CT images, of various diseases, that were obtained with single-detector (weighted dose index, 14.4 mGy) and multidetector (weighted dose index, 9.8 mGy) CT. Toggling between the original and compressed images, readers had to identify the original image by using a forced-choice two-alternative model and to subjectively rank the quality of what they believed to be the compressed image. To assess the reader's ability to distinguish the compressed from the original image, a binomial test was used. Bonferroni correction was applied for all multiple tests. RESULTS: Images compressed with a ratio of 3:1 were not distinguishable from original images (P > .2 for all readers). With use of the 5:1 ratio, minor differences in appearance between the compressed and original images were seen by one of the three readers. With use of higher compression ratios (>/=7:1), all readers (P < .001) recognized the original image. The quality of more than 90% of the images compressed with a 7:1 or higher ratio was substantially degraded. Single-detector and multidetector CT results were not significantly different. CONCLUSION: The highest ratio that yielded visually lossless compression of thin-section CT images was 3:1. With the 5:1 ratio, there was minor image quality loss, while use of higher compression ratios (>/=7:1) caused substantial degradation of image quality and potential loss of diagnostic information.

Adult↗

Methods and limits of digital image compression of retinal images for telemedicine.

PURPOSE: To investigate image compression of digital retinal images and the effect of various levels of compression on the quality of the images. METHODS: JPEG (Joint Photographic Experts Group) and Wavelet image compression techniques were applied in five different levels to 11 eyes with subtle retinal abnormalities and to 4 normal eyes. Image quality was assessed by four different methods: calculation of the root mean square (RMS) error between the original and compressed image, determining the level of arteriole branching, identification of retinal abnormalities by experienced observers, and a subjective assessment of overall image quality. To verify the techniques used and findings, a second set of retinal images was assessed by calculation of RMS error and overall image quality. RESULTS: Plots and tabulations of the data as a function of the final image size showed that when the original image size of 1.5 MB was reduced to 29 KB using JPEG compression, there was no serious degradation in quality. The smallest Wavelet compressed images in this study (15 KB) were generally still of acceptable quality. CONCLUSIONS: For situations where digital image transmission time and costs should be minimized, Wavelet image compression to 15 KB is recommended, although there is a slight cost of computational time. Where computational time should be minimized, and to remain compatible with other imaging systems, the use of JPEG compression to 29 KB is an excellent alternative.

Humans↗

[Registration of chest PET and CT images-fusion technique using the PET/Tr image by the respiration compensation].

OBJECTIVE: The conventional registration of PET images of the chest with CT images is performed by rotating and shifting those images while used median lines and contours on axial images as the reference indexes. For the thoracic and the abdominal regions, therefore, the respiratory movements have prevented us from achieving satisfactory levels of registration reproducibility and accuracy. In order to solve this, we have analyzed respiratory movements of the chest and derived an image fusion method. METHODS: Respiratory movements of the lung along each axis (X-axis: left-right, Y-axis: dorsoventral, and Z-axis: craniocaudal) during deep breathing were analyzed using CT-3D images. In addition, respiratory movements of the lung and thorax in the Y-axis and Z-axis directions during deep breathing and at rest were also analyzed by using an MR system that is the non-invasive method and allows for acquiring arbitrary tomographic images. Respiratory movements were compensated for on PET images of the lung. Moving average deviations in the Y-axis and Z-axis directions, which were obtained from the analytical result of respiration (30 samples), were used to derive the compensatory values. RESULTS: The analysis of CT-3D images showed that the movements in the X-axis direction were negligible. Registration of PET images with CT images was found useful when it performed on the sagittal planes. The analysis of MR images on sagittal planes revealed that the region extending from the apex of the lung to the posterior wall of the lung was useful for reference indexes for registration. The PET image by the compensation of the respiration transfer difference in the pulmonary hilum division was fusion on the CT image. In the pulmonary hilum division, the improvement in the accuracy of 3.6 mm in the dorsoventral and 6.1 mm in the craniocaudal direction was obtained in comparison with the fusion only of the reference index. CONCLUSION: The developed image fusion technique compensating the respiratory movements was found to be effective over the region of the hilum of the lung than the conventional technique.

Adult↗

An interactive histology image-barcode manual for a videodisc image library.

UNLABELLED: Cell Biology and HISTOLOGY (alias Microanatomy, alias Microscopic Anatomy) is a required course for first-year medical and dental students in most health science centers. The traditional approach used in teaching this discipline is to present photomicrographic images of structures to students in lecture using 35 mm slides of fields seen through the microscope. The students then spend many hours viewing and studying specimens of tissues using a light microscope in a laboratory setting. Students in traditional courses of histology spend an inordinate amount of time learning the component structures by attempting to find and identify them in tissue sections using a microscope, where the structure being sought is surrounded by a multitude of other structures with which they are also not familiar. With the recent availability of videodisc stored image libraries of histological samples, it is now possible to study histological principles without the use of the microscope as the primary learning tool. A videodisc entitled " HISTOLOGY: A Photographic Atlas" by S. Downing (published by Image Premastering Services Limited, Minneapolis, MN, 1991) has been incorporated into our histology course. Fifteen videodisc player stations are provided for 150 students. Images are retrieved by students using a bar code scanner attached to a videodisc player (Pioneer CLD-2400). Using this kind of image library, students can now learn basic histological structure, such as cell and tissue types, without the use of a microscope or as a tool for facilitating microscopy. The use of a videodisc library of randomly accessible images simplifies learning the basic components which all organs are composed of by presenting the learner with clear-cut examples to avoid confusion with other structures. However, videodisc players and TV monitors are still not appropriately priced for every student to own. This presents a problem in that the same images studied in class are not available to study and review outside of class. There is a need for resources for additional study outside of the institutional setting, for students to have and interact with to reinforce the learning experience in the teaching laboratory. A hard copy manual was created and is being used in our course; it incorporates photos captured from the videodisc. The images displayed in the manual are chosen to give the student one example of each histological component. Additional labeling is added to the images, and each image is accompanied by a bar code that may be used at a videodisc player with a bar code reader to retrieve the same color image from the disc displayed in larger format on a TV monitor. Each topic in the manual is accompanied by learning objectives and a statement of clinical relevance. Following the presentation of the images in each section of the manual, the students are encouraged to practice by viewing multiple examples of each structural component presented in the lesson. They can do this by using the bar-coded catalog supplied with each disc. The presentation of each topic concludes with a quiz composed of questions about images that the student can retrieve from the videodisc using barcodes in the text of the manual. Some of the images on the quiz are printed in miniature in the manual to provide the student with an opportunity for personal review at home when hardware to obtain and display images from a video disc is not available. This manual provides an answer to the dilemma faced by the learner when access to hardware is not available; reinforcement is therefore facilitated outside the teaching laboratory. This allows learning to continue outside of the classroom, using the same materials. (abstract truncated)

Computer-Assisted Instruction↗

Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging.

The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (Gd-BOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.

Adult↗

Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: report from Image-Guided Brachytherapy Working Group.

PURPOSE: To present issues to be considered in, and make proposals for, image-based brachytherapy for cervical cancer. METHODS AND MATERIALS: The Image-Guided Brachytherapy Working Group, consisting of representatives from the Gynecology Oncology Group (GOG), Radiologic Physics Center (RPC), American Brachytherapy Society (ABS), American College of Radiology (ACR), American College of Radiology Imaging Network (ACRIN), American Association of Physicists in Medicine (AAPM), Radiation Therapy Oncology Group (RTOG), and American Society for Therapeutic Radiology and Oncology (ASTRO), proposed guidelines for image-based brachytherapy for cervical cancer. This report was based on their aggregate clinical experience and a review of the literature. It reflects only the personal opinions of the authors and is not meant to be an endorsement from any of the above organizations. RESULTS: The Group recommended T(2)-weighted MRI using a pelvic surface coil with MRI-compatible brachytherapy applicators in place for image-based intracavitary brachytherapy for cervical cancer. Imaging must be performed with the patient in the treatment position, with all other treatment conditions duplicated as closely as possible. Future use of positron emission tomography or positron emission tomography/CT may obviate the need for special applicators. The group proposed the following terminology for image-based brachytherapy. The GTV((I)) is defined as the gross tumor volume as defined through imaging, GTV is defined as the GTV((I)) plus any clinically visualized or palpable tumor extensions, and GTV + cx is defined as the GTV plus the entire cervix. The dose-volume histograms (DVH) of the GTV, GTV((I)), GTV + cx should be performed, and the dose to 100%, 95%, or 90% of the GTV (D(100), D(95), and D(90), respectively) and the percentage of the GTV covered by Point A dose (V(100)) should be reported. Similarly, the DVH of the bladder and rectum wall should be performed, and the maximal dose at any point within the bladder and rectal wall should be reported, along with the maximal dose to a contiguous 1, 2, and 5 cm(3) volume of the bladder and rectum, respectively. In addition, the dose at the International Commission on Radiation Units and Measurements reference point for the bladder and rectum should be reported. The Group thought that the current dose prescription method in use for cervical cancer brachytherapy (i.e., to prescribe to Point A in most institutions) should not be changed as yet, because image-based dosimetry is not ready for routine practice. The Group proposes that for research purposes, individual centers and cooperative groups (e.g., GOG, RTOG, ACRIN) collect image-based dosimetry information and perform DVHs and correlate these data with the clinical outcome to determine which of the above parameters are relevant. The Group encourages external funding for image-based dosimetry and recommends that brachytherapy manufacturers develop image-compatible applicators. CONCLUSION: Although current institutional brachytherapy prescription for cervical cancer should continue, image-based data collection and analysis are needed to optimize cervical cancer brachytherapy. Proposals are made for research in image-based brachytherapy for cervical cancer.

Brachytherapy↗

MR imaging of coarctation of the aorta and its postoperative complications in adults: assessment with spin-echo and cine-MR imaging.

To evaluate the ability of ECG-gated spin-echo (SE)-MR imaging vs. cine-MR imaging to assess coarctation of the aorta, 11 patients aged 15-45 years, with known or suspected coarctation of the aorta, and five patients suspected of re-stenosis or postoperative false-aneurysms after coarctation repair were examined by multisection SE-MR imaging and single-section multiphase cine-MR imaging on a 1.0 Tesla device. Aortography was performed in 15, and surgery in 14 of these 16 patients. Qualitatively, the location, severity, and length of the coarctation were shown in all cases with MR imaging, as well as the relationship with the arteries arising from the aortic arch. The respective sensitivities and specificities in the assessment of severity of stenoses were 86% and 100% for SE MR images, and 100% and 100% for cine-MR images. Cine-MR imaging was superior to SE imaging in stenosis diameter assessment with contrast angiography as reference, as well as to identify the site of leakage in cases of postoperative pseudoaneurysm. Pre-stenotic dilation or post-stenotic aneurysm, collateral channels, and associated malformations were better identified on SE images. Quantitatively, a better stenosis diameter correlation was found between cine-MR images and angiography than between SE-MR images and angiography (r=0.99 vs. r=0.78; p=0.001 vs. p=0.004), related to overestimation of stenoses with SE-MR imaging. The use of a combination of spin-echo and cine-MR imaging correlates well with conventional angiographic findings in this small series of patients with coarctation of aorta or postoperative pseudoaneurysmal complications. Cine-MRI can provide anatomic information that is equivalent to angiography for surgical planning.

Adolescent↗

Detection of hypervascular hepatocellular carcinoma by dynamic magnetic resonance imaging with double-echo chemical shift in-phase and opposed-phase gradient echo technique: comparison with dynamic helical computed tomography imaging with double arterial phase.

PURPOSE: The technique of double-echo chemical shift gradient echo magnetic resonance imaging (MRI) with the fast low-angle shot (double-echo FLASH) sequence provides in-phase and opposed-phase images in a single breath hold. The purpose of this study was to evaluate the efficacy of dynamic MRI with double-echo FLASH imaging for the detection of hypervascular hepatocellular carcinoma by comparing it with dynamic helical computed tomography (CT) imaging with double arterial phase. MATERIALS AND METHODS: Twenty-nine patients with 67 hypervascular hepatocellular carcinoma nodules who underwent both dynamic MRI with double-echo FLASH imaging (repetition time/echo time/flip angle: 160/3.6, 7.0/80 degrees ) and dynamic helical CT imaging with double arterial phase were enrolled in the study. For dynamic MRI, precontrast, arterial, portal venous, and equilibrium phase images were obtained before and approximately 19, 60, and 120 seconds, respectively, after intravenous injection of 0.1 mmol/kg of gadopentetate dimeglumine at a rate of 2 ml/s. For dynamic CT imaging, quadraphase images, including early arterial, late arterial, portal venous, and equilibrium phases, were obtained serially approximately 20, 30, 70, and 180 seconds, respectively, after intravenous administration of 2 ml/kg of 300 mgI/ml of nonionic contrast medium at a rate of 5 ml/s. Three masked observers independently interpreted images obtained with each technique in random order, separately and without patient identifiers. Sensitivity and positive predictive values as well as the area below the alternative-free response receiver operating characteristic curve (Az) for each imaging technique were calculated and compared statistically. RESULTS: Mean sensitivity and positive predictive values of MRI for hypervascular hepatocellular carcinoma were 48% and 94%, respectively, and those of CT imaging were 47% and 91%, respectively. In 11 (38%) of the 29 patients, at least one observer judged dynamic MRI to be superior, whereas in 5 patients (17%), dynamic CT was judged to be superior. There was no significant difference in the sensitivity and positive predictive values between these techniques (p > 0.05). There was no significant difference either in mean Az values between CT (0.55) and MRI (0.57) (p = 0.61). CONCLUSION: Dynamic MRI with double-echo FLASH imaging can detect hypervascular hepatocellular carcinoma as well as dynamic helical CT imaging with double arterial phase.

Adult↗

Image registration for image-based rendering.

Image-based rendering (IBR) has received much attention in recent years for its ability to synthesize photo-realistic novel views. To support translational motion, existing IBR methods either require a large amount of reference images or assume that some geometric information is available. However, rendering with a large amount of images is very expensive in terms of image acquisition, data storage, and memory costs. As IBR accepts various kinds of geometric proxy, we may use image registration techniques, such as stereo matching and structure and motion recognition, to obtain geometric information to help reduce the number of images required. Unfortunately, existing image registration techniques only support a small search range and require closely sampled reference images. This results in a high spatial sampling rate, making IBR impractical for use in scalable walkthrough environments. Our primary objective of this project is to develop an image registration technique that would recover the geometric proxy for IBR while, at the same time, reducing the number of reference images required. In this paper, we analyze the roles and requirements of an image registration technique for reducing the spatial sampling rate. Based on these requirements, we present a novel image registration technique to automatically recover the geometric proxy from reference images. With the distinguishing feature of supporting a large search range, the new method can accurately identify correspondences even though the reference images may only be sparsely sampled. This can significantly reduce the acquisition effort, the model size, and the memory cost.

Algorithms↗

Unwarping confocal microscopy images of bee brains by nonrigid registration to a magnetic resonance microscopy image.

Confocal microscopy (CM) is a powerful image acquisition technique that is well established in many biological applications. It provides 3-D acquisition with high spatial resolution and can acquire several different channels of complementary image information. Due to the specimen extraction and preparation process, however, the shapes of imaged objects may differ considerably from their in vivo appearance. Magnetic resonance microscopy (MRM) is an evolving variant of magnetic resonance imaging, which achieves microscopic resolutions using a high magnetic field and strong magnetic gradients. Compared to CM imaging, MRM allows for in situ imaging and is virtually free of geometrical distortions. We propose to combine the advantages of both methods by unwarping CM images using a MRM reference image. Our method incorporates a sequence of image processing operators applied to the MRM image, followed by a two-stage intensity-based registration to compute a nonrigid coordinate transformation between the CM images and the MRM image. We present results obtained using CM images from the brains of 20 honey bees and a MRM image of an in situ bee brain.

Animals↗

Patient positioning method based on binary image correlation between two edge images for proton-beam radiation therapy.

A new technique based on normalized binary image correlation between two edge images has been proposed for positioning proton-beam radiotherapy patients. A Canny edge detector was used to extract two edge images from a reference x-ray image and a test x-ray image of a patient before positioning. While translating and rotating the edged test image, the absolute value of the normalized binary image correlation between the two edge images is iteratively maximized. Each time before rotation, dilation is applied to the edged test image to avoid a steep reduction of the image correlation. To evaluate robustness of the proposed method, a simulation has been carried out using 240 simulated edged head front-view images extracted from a reference image by varying parameters of the Canny algorithm with a given range of rotation angles and translation amounts in x and y directions. It was shown that resulting registration errors have an accuracy of one pixel in x and y directions and zero degrees in rotation, even when the number of edge pixels significantly differs between the edged reference image and the edged simulation image. Subsequently, positioning experiments using several sets of head, lung, and hip data have been performed. We have observed that the differences of translation and rotation between manual positioning and the proposed method were within one pixel in translation and one degree in rotation. From the results of the validation study, it can be concluded that a significant reduction in workload for the physicians and technicians can be achieved with this method.

Algorithms↗

The impact of image information on compressibility and degradation in medical image compression.

The aim of the study was to demonstrate and critically discuss the influence of image information on compressibility and image degradation. The influence of image information on image compression was demonstrated on the axial computed tomography images of a head. The standard Joint Photographic Expert Group (JPEG) and JPEG 2000 compression methods were used in compression ratio (CR) and in quality factor (QF) compression modes. Image information was estimated by calculating image entropy, while the effects of image compression were evaluated quantitatively, by file size reduction and by local and global mean square error (MSE), and qualitatively, by visual perception of distortion in high and low contrast test patterns. In QF compression mode, a strong correlation between image entropy and file size was found for JPEG (r=0.87, p < 0.001) and JPEG 2000 (r=0.84, p < 0.001), while corresponding local MSE was constant (4.54) or nearly constant (2.36-2.37), respectively. For JPEG 2000 CR compression mode, CR was nearly constant (1:25), while local MSE varied considerably (2.26 and 10.09). The obtained qualitative and quantitative results clearly demonstrate that image degradation highly depends on image information, which indicates that the degree of image degradation cannot be guaranteed in CR but only in QF compression mode. CR is therefore not a measure of choice for expressing the degree of image degradation in medical image compression. Moreover, even when using QF compression modes, objective evaluation, and comparison of the compression methods within and between studies is often not possible due to the lack of standardization of compression quality scales.

Algorithms↗

Chronic prostatitis: MR imaging and 1H MR spectroscopic imaging findings--initial observations.

PURPOSE: To determine whether chronic prostatitis affects three-dimensional proton magnetic resonance (MR) spectroscopic imaging in evaluation of disease in the peripheral zone. MATERIALS AND METHODS: Combined MR imaging and three-dimensional MR spectroscopic imaging data were examined retrospectively in 12 patients with radical prostatectomy specimens that contained regions of chronic prostatitis larger than 6 mm in the peripheral zone. The 6-mm restriction was based on MR spectroscopic imaging spatial resolution of 6.25 mm. Transverse T2-weighted MR images were reviewed for changes in signal intensity (SI): normal, suspicious for cancer (nodular focal low SI), or indeterminate (focal low SI that was not nodular or contour deforming or diffuse low SI). At MR spectroscopic imaging, proton spectra were considered suspicious for cancer if the ratio of choline plus creatine to citrate was more than 2 SDs above normal mean peripheral zone values. RESULTS: In the 12 patients, mean pretreatment prostate-specific antigen level was 5.77 +/- 2.07 (SD), and median biopsy Gleason score for the gland was 6. At MR imaging in the area of histopathologically confirmed chronic prostatitis, seven of 12 patients had focal low SI that was not nodular (contour deforming) over a region in and around the pathologically defined focus of chronic prostatitis. MR imaging in one patient showed diffuse low SI that correlated with a diffuse area of chronic prostatitis at pathologic examination. MR imaging in another patient showed nodular focal low SI that was suspicious for cancer and corresponded to a focus of chronic prostatitis at pathologic examination. The remaining three patients had no MR imaging abnormality in the region of chronic prostatitis. In the pathologically identified regions of chronic prostatitis, MR spectroscopic imaging data in nine of 12 patients demonstrated elevated choline peak and reduced or no citrate, findings that mimic those of cancer. In two patients, the spectra were normal, and in the remaining patient, the spectra were nondiagnostic. CONCLUSION: At MR spectroscopic imaging, pathologically confirmed chronic prostatitis may demonstrate metabolic abnormality that leads to false-positive diagnosis of cancer. The most common MR imaging finding in chronic prostatitis was focal low SI that was not specific for cancer. In one patient, the MR imaging diagnosis of cancer could not be excluded.

Aged↗

Malignant hepatic tumor detection with ferumoxides-enhanced MR imaging with a 1.5-T system: comparison of four imaging pulse sequences.

The purpose of our study was to compare observer performance in the detection of malignant hepatic tumors with ferumoxides-enhanced magnetic resonance (MR) images obtained with proton density-weighted spin-echo (SE), T2-weighted fast SE, T2*-weighted gradient-recalled-echo (GRE), and proton density-weighted echo-planar (EP) sequences. Ferumoxides-enhanced MR images obtained with the four sequences in 50 patients with 92 solid malignant and 64 nonsolid benign lesions were retrospectively analyzed. Image review was conducted on a segment-by-segment basis; a total of 397 liver segments was reviewed separately for solid and nonsolid lesions by three independent readers. Observer performance was evaluated with receiver operating characteristic analysis. Lesion-to-liver contrast-to-noise ratio was higher with SE and EP than with GRE and fast SE images for solid lesions (P < 0.05), and higher with fast SE and SE than with GRE images for nonsolid lesions (P < 0.01). Proton density-weighted SE and T2-weighted fast-SE images were superior to T2*-weighted GRE and proton density-weighted EP images for detection of malignant hepatic tumors. T2-weighted fast SE images were the best for detection of nonsolid lesions. T2-weighted fast SE images that were comparable to proton density-weighted SE images for solid tumor detection, that were the best for nonsolid lesion detection, and that had an acquisition time of one third to half of that of SE imaging may be able to replace SE images for ferumoxides-enhanced liver imaging.

Aged↗