Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Measurement of the proportion of free to total prostate-specific antigen improves diagnostic performance of prostate-specific antigen in the diagnostic gray zone of total prostate-specific antigen.

OBJECTIVES: This study examined the clinical significance of non-complexed (free) prostate-specific antigen (PSA) in the differential diagnosis of prostate cancer with an emphasis on patients with total PSA values between 4.0 and 10.0 ng/mL (the diagnostic gray zone). METHODS: Serum samples were obtained from three specimen banks. Patient samples consisted of 55 untreated histologically confirmed primary cancer, 62 men with untreated benign prostatic disease histologically confirmed by 6 negative sextant biopsies, and 64 asymptomatic healthy male controls with normal digital rectal examinations and PSA values less than 4.0 ng/mL. All patients were between the ages of 50 and 75 years. Total PSA levels were determined using the PA immunoassay performed on the TOSOH AIA-1200 automated immunoassay instrument. Free PSA levels were determined using a monoclonal-polyclonal antibody sandwich radioimmunoassay. The proportion of free to total PSA was calculated by dividing the patient's free PSA value by the total PSA value. RESULTS: When all subjects were included, both total PSA and the proportion of free to total PSA significantly differentiated between patients with prostate cancer and patients with benign histologic conditions (P < 0.0001). However, in men with total PSA values between 4.0 and 10.0 ng/mL, the proportion of free to total PSA significantly differentiated between patients with benign and malignant histologic conditions (P = 0.0004), whereas the total PSA did not (P = 0.13). Among this subgroup of patients, the analysis of sensitivity and specificity showed that the proportion of free to total PSA had a clearly higher specificity compared with that of the total PSA at the same level of sensitivity. CONCLUSIONS: Measurement of the free PSA level in a patient's serum and calculation of the proportion of free to total PSA enhances the ability to distinguish benign histologic conditions from cancer while retaining high sensitivity for detecting cancer in men who present with total PSA levels between 4.0 and 10.0 ng/mL. A large-scale population-based study is currently in progress to confirm this preliminary finding.

Aged↗

Validation of two survey diagnostic interviews among primary care attendees: a comparison of CIS-R and CIDI with SCAN ICD-10 diagnostic categories.

BACKGROUND: The most widely used survey measures in psychiatry, the Composite International Diagnostic Interview (CIDI) and the Clinical Interview Schedule-Revised (CIS-R) have generated estimates of psychiatric morbidity that show considerable variation. Doubts have been raised regarding the validity of these structured lay interviewer assessments. There have been no direct comparisons of the performances of these instruments against a common, established criterion. METHOD: A total of 105 unselected primary care attendees were each interviewed with CIDI, CIS-R and SCAN in a single sitting with random order of administration. SCAN was administered by a SCAN trained psychiatrist, and CIDI and CIS-R by a public health doctor. Concordance was estimated for all ICD-10 neurotic disorders. We assessed the overall discriminability of the CIS-R morbidity scale using a receiver operating characteristic (ROC) analysis. RESULTS: The concordance for CIDI for ICD-10 diagnoses was moderate to excellent (kappa= 0.58-0.97). Concordance for CIS-R ranged between poor and moderate (kappa = 0.10-0.65). The area under the ROC curve for the CIS-R morbidity scale with respect to any ICD-10 disorder [0.87 (95% CI 0.79-0-95)] indicated good overall discriminability, but poor sensitivity (44%) and high specificity (97%) at the usual CIS-R cut-point of 11/12. CONCLUSION: Among primary care attendees the CIDI is a highly valid assessment of common mental disorders, and the CIS-R is moderately valid. Previous studies may have underestimated validity. Against the criteria of all ICD-10 diagnoses (including less severe depressive and anxiety disorders) a much lower CIS-R cut-point is required than that which is usually advocated.

Adult↗

The Autism Diagnostic Interview-Revised and the Childhood Autism Rating Scale: differences between diagnostic systems and comparison between genders.

Diagnoses for autism based on the Autism Diagnostic Interview-Revised (ADI-R) and the Childhood Autism Rating Scale (CARS) were examined for 83 individuals with suspected autism. Agreement between systems reached 85.7%. Participants receiving diagnosis of autism based on only one system were significantly younger in age than individuals receiving diagnoses according to both systems. Individuals who did not receive diagnosis of autism on the ADI-R had lower chronological and mental ages and lower CARS scores compared to individuals who received diagnosis of autism based on the ADI-R. Eighteen females and 18 males were matched to examine possible gender differences. No significant findings were revealed, suggesting that the symptoms of autism according to the ADI-R and CARS do not differ between males and females when matched for chronological and mental ages.

Adolescent↗

[Quality of praenatal diagnostic ultrasound - comparison of sonographically detected foetal anomalies with diagnostic findings verified post-partum in Switzerland].

AIM: Comparison of all praenatally detected cases of foetal anomalies to actual diagnostic findings post partum during a one year period in Switzerland. METHODS: A retrospective questionnaire-based evaluation including the 5 university hospitals and 6 large hospitals in Switzerland as a population-based study. Analysis of all foetal anomalies detected praenatally by ultrasound in the year of 1995 in these centres. RESULTS: 347 cases have been included in the study. 89 % of cases were detected using screening methods. (2/3) were referred by obstetrical practitioners and GPs. 62 % of the pregnancies were completed and 33 % terminated, while the rest resulted in abortion or stillbirth. In terminated pregnancies there was a 82 % agreement between praenatal and postmortem findings. Sonographic results and clinical/post-mortem diagnosis were in agreement about the presence of major foetal anomalies in 18 % of cases. Additional minor anomalies unperceived by sonography, however, were seen post mortem. There was no false positive case. CONCLUSIONS: Without ultrasound screening almost 90 % of anomalies would have been missed due to the absence of clinical symptoms. The Swiss two-step system for praenatal ultrasound screening, based on screening scans done by the obstetrician and GP in practice, or residents in the public outpatient clinics respectively, and the detailed scan done by a subspecialized perinatologist shows excellent results especially in the subgroup of terminated pregnancies.

Abortion, Eugenic↗

Detecting Attention Deficit Hyperactivity Disorder in a communications clinic: diagnostic utility of the Gordon Diagnostic System.

This study examines the sensitivity, specificity, predictive values, and likelihood ratios of laboratory measures of attention and impulsivity (the Gordon Diagnostic System; GDS) in 99 school-aged boys with a history of suspected language disorders. Classification analyses comparing scores from these tests with parent and teacher ratings of attention deficit hyperactivity disorder (ADHD) symptoms revealed low positive predictive values (20.0% to 36.8%) and high negative predictive values (71.9% to 87.9%). Likelihood ratios for abnormal test scores were low to moderate (0.74 to 1.73), suggesting that these tests may not accurately identify children with ADHD. Likelihood ratios for normal scores were also low to moderate (0.41 to 1.16). These findings suggest that GDS scores have clinical utility in ruling out a diagnosis of ADHD, but not in confirming the diagnosis in a clinic population of boys with communicative disorders who are at risk for developing ADHD.

Attention↗

The impact of a physician assistant in diagnostic radiology [PA-DR] on the delivery of diagnostic radiologic clincial services.

A program to train highly selected, experienced radiologic technologists to become Physician Assistants in Diagnostic Radiology [PA-DRs] was initiated at the University of Kentucky Medical Center in 1970. The initial postgraduate year of employment in several different radiologic environments for the first twelve trainees has been evaluated. Their work activities, including examinations that otherwise would have been performed by a radiologist and the number of radiographs screened for evidence of diseases, were analyzed. Studies during their training show they perform these activities accurately. Lastly, the economic impact of PA-DRs and their acceptability to patients and other professionals were evaluated. The PA-DRs spent a majority of their time in activities for which they were trained. Calculated yearly "earnings" of the PA-DRs averaged +31,164. Their salaries ranged +18-25,000. Each PA-DR averaged saving 34% of the employing radiologist's time. They were well accepted by professional colleagues and patients.

Costs and Cost Analysis↗

Evaluation of a diagnostic protocol using screening diagnostic peritoneal lavage with selective use of abdominal computed tomography in blunt abdominal trauma.

BACKGROUND: The optimal method of evaluating blunt abdominal trauma remains controversial. A combination of a sensitive screening test, diagnostic peritoneal lavage (DPL), and a specific test, abdominal computed tomography (CT), may be a safe, efficient approach to adult blunt abdominal trauma. METHODS: A prospective cohort study compared a protocol using screening DPL followed by selective use of abdominal CT (DPL/abdominal CT) and the use of abdominal CT alone in the evaluation of hemodynamically stable, adult blunt trauma patients. RESULTS: One hundred sixty-seven adult blunt trauma patients were initially evaluated by DPL (n = 71) or abdominal CT (n = 96). Emergency department evaluation required less time in the DPL/abdominal CT group than in the abdominal CT alone group (41 minutes vs. 2.5 hours; p < 0.001). There were no missed injuries in the DPL/abdominal CT group versus seven missed injuries in the abdominal CT group (p = 0.02). There were no nontherapeutic celiotomies in either study group. CONCLUSION: Screening DPL, followed by abdominal CT if positive, is a safe, efficient method of evaluating adult blunt abdominal trauma that reduces the time required to evaluate the abdomen, does not result in increased nontherapeutic celiotomies, results in fewer missed injuries, and reduces the overall use of abdominal CT.

Abdominal Injuries↗

The diagnostic and predictive value of cerebrospinal fluid lactate in children with meningitis. Its relation to current diagnostic methods.

One hundred and thirty-three children with suspected meningitis aged from 11 days to 16 years were investigated with routine cerebrospinal fluid (CSF) laboratory methods: microscopy of a Gram-stained smear, bacterial culture, determination of leukocytes, lactate, and the CSF/blood glucose ratio. On the basis of bacterial cultures and clinical course, the children were classified into three groups: bacterial meningitis (n = 18), aseptic meningitis (n = 28), and a control group (n = 87). The main intention was to study the relation between current diagnostic methods and lactate. CSF lactate levels and cell counts, related significantly (p less than 0.01) better to the presence of bacterial meningitis than CSF/blood glucose ratios. Lactate levels exceed 2.4 mmol/l in all children with bacterial meningitis, but in none of the control group. Of 28 children with aseptic meningitis 3 had lactate in the range 2.5-2.7 mmol/l, while the others had values of 2.4 mmol/l or less. We consider CSF lactate to be the best predictor in the clinical decision to institute antibiotic treatment of children with suspected bacterial meningitis.

Adolescent↗

Diagnostic, predictive, and prenatal testing for facioscapulohumeral muscular dystrophy: diagnostic approach for sporadic and familial cases.

Facioscapulohumeral muscular dystrophy (FSHD) is one of the common inherited neuromuscular disorders. The major gene involved, FSHD1, has been localised to chromosome 4q35. This 4q35 locus, detected by pE13-11 (D4F104S1), shows a mutation frequency of about 10% of the incidence. New mutants are characterised by de novo deletions of tens to hundreds of kilobases of DNA. Although these deletion fragments are very useful as a molecular genetic tool, their use in diagnostic DNA testing is hampered by multiple factors, particularly in familial cases. In this report we describe a protocol that can be used for DNA testing in well defined familial cases or proven de novo cases, and in the differential diagnosis of muscular dystrophy patients clinically suspected of having FSHD. In addition, we describe a prenatal diagnosis performed for FSHD1.

DNA↗

Acetylcholine receptor antibody as a diagnostic test for myasthenia gravis: results in 153 validated cases and 2967 diagnostic assays.

Anti-acetylcholine receptor (AChR) antibody was undetectable in 26/153 (17%) sera from myasthenia gravis patients assayed by standard RIA using human acetylcholine receptor. Eight of these were found to be positive with a modified protocol using a mixture of normal and denervated AChR, reducing the proportion of "negative" sera to 12%. Many of these were from patients with a short history; two such patients later developed low positive values. Anti-AChR without clinical evidence of myasthenia was found in one of three monozygotic twins of myasthenia gravis patients, and in one of thirty other first degree relatives of a further 17 patients. Anti-AChR is a valuable and highly specific diagnostic test which, with the assay used here, is positive in about 88% of patients with clinical features of myasthenia gravis.

Antibody Specificity↗

Immunocytochemistry and DNA-image cytometry in diagnostic effusion cytology. II. Diagnostic accuracy in equivocal smears.

To determine sensitivity and specificity of different antibodies for the immunocytochemical detection of malignant cells in diagnostically equivocal effusions in comparison with those achieved by DNA-image cytometry. 65 cytologically doubtful effusions of the serous cavities were stained with twelve antibodies. Furthermore, DNA-image cytometry was performed. Data were correlated with patient follow-up. Sensitivity of cellular staining of Ber-EP4 for the identification of malignant cells was 77.8%, specificity of absent staining for benign cells was 100%. Positive predictive value for the identification of malignant cells was 100%, negative value 65.5%. Sensitivity of DNA-aneuploidy for the identification of malignancy was 82.9%, specificity of DNA-non-aneuploidy for benignity 94.7%. The positive predictive value of DNA-aneuploidy for the occurrence of malignant cells was 96.7%. Negative predictive value of DNA-non-aneuploidy was 72.0%. Combining immunocytochemistry applying Ber-EP4 only and DNA-cytometry in equivocal effusions resulted in a sensitivity of 88.9% for the identification of malignant cells associated with a 95.0% specificity. Positive predictive value was 97.7%, the negative one 79.2%.

Aneuploidy↗

Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: report of the Atrial Diagnostics Ancillary Study of the MOde Selection Trial (MOST).

BACKGROUND: Some current pacing systems can automatically detect and record atrial tachyarrhythmias that may be asymptomatic. We prospectively studied a 312-patient (pt) subgroup of MOST (MOde Selection Trial), a 2010-patient, 6-year randomized trial of DDDR versus VVIR pacing in sinus node dysfunction (SND). The purpose of the study was to correlate atrial high rate events (AHREs) detected by pacemaker diagnostics with clinical outcomes. METHODS AND RESULTS: Pacemakers were programmed to log an AHRE when the atrial rate was >220 bpm for 10 consecutive beats. Analysis was confined to patients with at least 1 AHRE duration exceeding 5 minutes. The 312 patients were median age 74 years, 55% female, and 60% had a history of SVT. 160 of 312 (51.3%) patients enrolled had at least 1 AHRE >5 minutes duration over median follow-up of 27 months. Cox proportional hazards analysis assessed the relationship of AHREs with clinical events, adjusting for prognostic variables and baseline covariates. The presence of any AHRE was an independent predictor of the following: total mortality (hazard ratio AHRE versus no AHRE and 95% confidence intervals=2.48 [1.25, 4.91], P=0.0092); death or nonfatal stroke (2.79 [1.51, 5.15], P=0.0011); and atrial fibrillation (5.93 [2.88, 12.2], P=0.0001). There was no significant effect of pacing mode on the presence or absence of AHREs. CONCLUSIONS: AHRE detected by pacemakers in patients with SND identify patients that are more than twice as likely to die or have a stroke, and 6 times as likely to develop atrial fibrillation as similar patients without AHRE.

Adult↗

Diagnostic value of computer tomography in chronic pancreatitis: a comparison with current diagnostic tests.

During a 3-year period 39 patients with chronic pancreatitis were subjected to roentgen examinations and exocrine pancreatic function tests (EPFT). Computer tomography (CT) was carried out in 36 of these, and revealed pancreatic disease in 29, while characteristic findings of chronic pancreatitis were demonstrated in 24 patients. CT was particularly valuable in diagnosing intra and extrapancreatic pseudocysts and pancreatic abscesses complicating chronic pancreatitis. At endoscopic retrograde pancreatography (ERP) pathologic alterations were demonstrated in 23 of 24 patients, and was diagnostic for chronic pancreatitis in 20 patients. The cannulation failed in 7 patients. The results indicate that ERP cannot be replaced by CT. ERP is still needed for detailed demonstration of the pancreatic duct system, especially preoperatively. Conventional films of the abdomen, EPFT and angiography were the least sensitive tests.

Adult↗

The diagnostic process in outpatient endocrine care with special reference to screening. Further study of diagnostic patterns, their changes, total and diagnosis-specific resource consumption.

A screening procedure based on physical examination alone was used in the outpatient unit of a department of endocrinology and metabolism. The volume effectiveness and efficiency of this diagnostic process was evaluated by studying the case-records and by mail questionnaire. The case-records of 296 patients admitted to the clinic during 1968 were analyzed. It was found that 103 of these patients were immediately referred back after a brief physical examination only. The pattern of diagnosis, its changes during the screening procedure, and the outpatient-investigation were also studied. 50% of the patients subjected to outpatient-investigation ended up with a new diagnosis. It was also possible to construct a diagnosis-specific cost estimate for outpatient-investigation, starting from a non-confident and arriving at a confident diagnosis. The distribution of these costs was very skew. The cost for the physician performing the screening was estimated to represent only 2.6% of the costs saved by the introduction of the screening.

Adolescent↗

Diagnostic utility of BINAX NOW RSV--an evaluation of the diagnostic performance of BINAX NOW RSV in comparison with cell culture and direct immunofluorescence.

BACKGROUND: The regular increase in the incidence of respiratory illness caused by respiratory syncytial virus (RSV) during winter months in the United Kingdom, and other countries with temperate climate is usually accompanied by increased bed pressures especially in paediatric units in these countries. As a result, there is usually an increase in the demand for infection control services during these months. This makes obvious the need for making a rapid diagnosis of the infection during these months. BINAX NOW RSV (Maine, USA), a rapid membrane based immunochromatographic assay was designed to achieve this objective. METHODS: This study evaluated the diagnostic performance of BINAX NOW RSV in comparison with the methods routinely used in our laboratory namely direct immunofluorescence (DIF) and cell culture. RESULTS AND CONCLUSION: Results indicate that Binax Now RSV could be relied on to make infection control decisions in paediatric units during periods of peak RSV activity.

Automation↗

Diagnostic imaging, a "parallel" discipline. Can current technology provide a reliable digital diagnostic radiology department?

Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted we argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. Successes in applying new imaging devices using digital technology, numerical methods and more easily available computing power are directing radiology towards the concept of all-digital departmental complexes. Hence a critical discussion of fundamental problems should be encouraged, to promote a thorough understanding of what may be involved (Gray et al, 1984) in following such a course. It is equally important to gain some perspective about the development possibilities for existing, commercially available equipment being offered to the medical community.

Computers↗

Pancreatic neuroendocrine neoplasms: a current summary of diagnostic, prognostic, and differential diagnostic information.

Pancreatic endocrine tumors (PETs) continue to be challenging diagnostic and prognostic lesions in surgical pathology and clinical medicine. These neoplasms can be graded into 1 of 3 tiers, based on histologic characteristics in likeness to epithelial neuroendocrine tumors in other anatomic sites. However, grade 1 tumors are by far the most common and are the most difficult to prognosticate. The most helpful features by which to gauge the behavior of such lesions include size (3 cm or larger); mitotic activity (2 or more mitoses per 10 high-power [x400] microscopic fields); marked nuclear atypia, especially with atypical mitoticfigures; predominant tumor synthesis of gastrin, vasoactive intestinal polypeptide, somatostatin, glucagon, calcitonin, or adrenocorticotropic hormone; complete nonfunctionality of the tumor at an immunohistochemical level; or invasion of blood vessels, nerves, or adjacent organs by the neoplasm. Differential diagnosis of PETs includes lesions such as solid-pseudopapillary neoplasms, acinar carcinomas, metastatic neuroendocrine tumors, and plasmacytomas.

Cell Nucleus↗

HPLC retention time as a diagnostic tool for hemoglobin variants and hemoglobinopathies: a study of 60000 samples in a clinical diagnostic laboratory.

BACKGROUND: Previous evaluations of HPLC as a tool for detection of hemoglobin variants have done so within newborn-screening programs and/or by use of stored samples. We describe a 32-month prospective study in a clinical diagnostic laboratory in which we evaluated the imprecision of HPLC retention times and determined the retention times for hemoglobin variants seen in a multiethnic setting. METHODS: We analyzed all samples on the Bio-Rad Variant II HPLC system. For normal hemoglobin fractions and hemoglobin variants, we recorded and analyzed their retention times, their proportion of the total hemoglobin (%), and the peak characteristics. We compared the imprecision of retention time with the imprecision of retention time normalized to the retention time of hemoglobin A0 (Hb A0) and to the retention time of Hb A2. Alkaline and acid hemoglobin electrophoresis, and in certain cases globin chain electrophoresis, isoelectric focusing, and DNA analysis, were performed to document the identities of the hemoglobin variants. RESULTS: The mean (SD) imprecision (CV) of the retention time was 1.0 (0.7)% with no statistical difference compared with the imprecision for normalized retention times. Among 60,293 samples tested, we encountered 34 unique hemoglobin variants and 2 tetramers. Eighteen variants and 2 tetramers could be identified solely by retention time and 3 variants by retention time and proportion of total hemoglobin. Four variants could be identified by retention time and peak characteristics and eight variants by retention time and electrophoretic mobility. One variant (Hb New York) was missed on HPLC. Retention time on HPLC was superior to electrophoresis for the differentiation and identification of six members of the Hb J family, four members of the Hb D family, and three variants with electrophoretic mobilities identical or similar to that of Hb C. Six variants with electrophoretic mobilities identical or similar to that of Hb S could be differentiated and identified by retention time and proportion of total hemoglobin. HPLC detected two variants (Hb Ty Gard and Hb Twin Peaks) missed on electrophoresis. CONCLUSIONS: The retention time on HPLC is reliable, reproducible, and in many cases superior to conventional hemoglobin electrophoresis for the detection and identification of hemoglobin variants. Confirmatory testing by electrophoresis can be eliminated in the majority of cases by use of retention time, proportion of total hemoglobin, and peak characteristics of HPLC.

Chromatography, High Pressure Liquid↗