Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Diagnostic performance of intraoperative in vivo hyperspectral imaging for meningioma grading and molecular alterations: results from a prospective feasibility study.

OBJECTIVE: Hyperspectral imaging (HSI) is an emerging intraoperative, noninvasive, contrast agent-free imaging modality that enables quantitative assessment of tissue composition. The present study aimed to investigate whether HSI-derived tissue parameters correlate with WHO grade and molecular markers of aggressiveness in cranial meningiomas. METHODS: In this prospective study, intraoperative in vivo HSI was performed using the TIVITA tissue system, capturing spectral signatures between 500 and 1000 nm. Quantitative tissue parameters included tissue oxygen saturation (StO2), near-infrared perfusion index, organ hemoglobin index (OHI), and tissue water index (TWI). HSI parameters were correlated with histopathological WHO grade and molecular alterations, including CDKN2A/B deletion, TERT promoter mutation, and 1p/22q loss. Group differences were analyzed using one-way ANOVA, and diagnostic performance was assessed using receiver operating characteristic (ROC) analysis. RESULTS: Forty-six meningiomas were included, comprising WHO grade 1 (n = 35) and WHO grade 2-3 (n = 11) tumors. TWI was significantly higher in WHO grade 2-3 meningiomas compared with WHO grade 1 tumors (mean 0.49 [SD 0.12] vs 0.38 [SD 0.17], p = 0.048). ROC analysis demonstrated an area under the ROC curve (AUC) of 0.71 (95% CI 0.56-0.86, p = 0.036) for TWI in discriminating higher-grade disease. A TWI cutoff ≥ 0.367 identified all WHO grade 2-3 meningiomas with 100% sensitivity and 100% negative predictive value. In a molecular subgroup (n = 15), OHI appeared higher in tumors with homozygous CDKN2A/B deletion than in nondeleted tumors (mean 0.77 [SD 0.04] vs 0.62 [SD 0.10]). However, only 3 CDKN2A/B-deleted cases were available, and these findings should be considered descriptive. ROC analysis yielded an AUC of 0.89 (95% CI 0.71-1.00). An OHI cutoff ≥ 0.712 identified all three CDKN2A/B-deleted tumors (100% sensitivity), with 83.3% specificity and 86.7% accuracy. CONCLUSIONS: The present investigation demonstrated that HSI-derived tissue water and hemoglobin metrics provide biologically meaningful information in meningiomas. Low tissue water content appeared to rule out higher-grade diseases in this first subset cohort, while elevated hemoglobin showed a potential association with CDKN2A/B deletion in a small exploratory subgroup. These findings support the potential of HSI as a real-time noninvasive tool for intraoperative risk stratification and should be evaluated in large-scale studies. German Clinical Trials Register no. DRKS00036771 (www.drks.de).

Humans↗

Acridine Orange for malaria diagnosis: its diagnostic performance, its promotion and implementation in Tanzania, and the implications for malaria control.

One hundred years ago, Giemsa's stain was employed for the first time for malaria diagnosis. Giemsa staining continues to be the method of choice in most malarious countries, although, in the recent past, several alternatives have been developed that exhibit some advantages. Considerable progress has been made with fluorescent dyes, particularly with Acridine Orange (AO). The literature on the discovery, development and validation of the AO method for malaria diagnosis is reviewed here. Compared with conventional Giemsa staining, AO shows a good diagnostic performance, with sensitivities of 81.3%-100% and specificities of 86.4%-100%. However, sensitivities decrease with lower parasite densities, and species differentiation may occasionally be difficult. The most notable advantage of the AO method over Giemsa staining is its promptness; results are readily available within 3-10 min, whereas Giemsa staining may take 45 min or even longer. This is an important advantage for the organization of health services and the provision of effective treatment of malaria cases. The national malaria control programme of Tanzania, together with the Japan International Co-operation Agency, began to introduce the AO method in Tanzania in 1994. So far, AO staining has been introduced in 70 regional and district hospitals, and 400 laboratory technicians have been trained to use the method. The results of this introduction, which are reviewed here and have several important implications, indicate that AO is a viable alternative technique for the laboratory diagnosis of malaria in highly endemic countries.

Acridine Orange↗

Diagnostic utility of BINAX NOW RSV--an evaluation of the diagnostic performance of BINAX NOW RSV in comparison with cell culture and direct immunofluorescence.

BACKGROUND: The regular increase in the incidence of respiratory illness caused by respiratory syncytial virus (RSV) during winter months in the United Kingdom, and other countries with temperate climate is usually accompanied by increased bed pressures especially in paediatric units in these countries. As a result, there is usually an increase in the demand for infection control services during these months. This makes obvious the need for making a rapid diagnosis of the infection during these months. BINAX NOW RSV (Maine, USA), a rapid membrane based immunochromatographic assay was designed to achieve this objective. METHODS: This study evaluated the diagnostic performance of BINAX NOW RSV in comparison with the methods routinely used in our laboratory namely direct immunofluorescence (DIF) and cell culture. RESULTS AND CONCLUSION: Results indicate that Binax Now RSV could be relied on to make infection control decisions in paediatric units during periods of peak RSV activity.

Automation↗

The effect of a picture archiving and communications system (PACS) on diagnostic performance in the accident and emergency department.

OBJECTIVE: A study has been conducted to identify the benefits to the accident and emergency (A&E) department of a hospital wide Picture Archiving and Communications System (PACS). METHODS: The study was conducted in two parts: firstly while the hospital was using conventional radiographic films, and secondly when the PACS was in operation. For each part of the study, the diagnoses of radiographic images made by A&E clinicians were compared with those made by radiologists. This resulted in the estimation of the incidence of false negative findings by the A&E staff. The management of patients with such findings was studied to identify those for whom a change of treatment was required. Such data for the two periods, when film and when PACS was used, were compared. RESULTS: It was found that the overall rate of misdiagnoses across all A&E patients who had radiography was low in both periods and there was a significant reduction when PACS was used (1.5% for film and 0.7% for PACS, 95% CI for difference between proportions: -0.014 to -0.0034), but the rate of serious misdiagnoses involving patient recall did not change significantly (95% CI for difference between proportions: -0.0059 to +0.0001). CONCLUSIONS: When PACS was used the diagnostic performance by A&E staff improved by reducing false negative interpretations but the rate of serious misdiagnosis did not change.

Diagnostic Errors↗

Rapid and complete coronary arterial tree visualization with magnetic resonance imaging: feasibility and diagnostic performance.

AIMS: Current imaging of the coronary arteries with magnetic resonance coronary angiography (MRCA) is restricted to limited coverage of the coronary arterial tree and requires complex planning. We present and evaluate a rapid, single-scan MRCA approach with complete coverage of the coronary arterial tree. METHODS AND RESULTS: Fifty-five consecutive patients with suspected coronary artery disease underwent free-breathing, navigator-gated MRCA using a single three-dimensional volume with transversal slice orientation and nearly isotropic spatial resolution (1.2 x 1.2 x 1.4 mm(3)) with coverage of the whole heart [steady-state free precession (SSFP); TR/TE/flip angle: 5.3 ms/2.6 ms/90 degrees ; Philips Intera CV 1.5T]. The acquisition duration per heart beat was individually adapted to the cardiac rest period. Correction of respiratory motion was done using a patient-specific affine prospective navigator technique (two navigator beams: cranio-caudal position on the dome of the right hemidiaphragm and anterior-posterior position on the right chest wall; gating window 10 mm). The diagnostic performance of MRCA in detecting significant coronary stenoses was evaluated against X-ray angiography as the standard of reference (32 patients) using a 16-segment model. Effective scan duration was 18+/-6 min (navigator efficiency: 68+/-14%). In all examinations, the main epicardial vessels [left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA)], including their distal segments and major side branches (number of visible side branches: LAD, 2.0+/-0.9; LCX, 1.5+/-0.6; RCA, 2.3+/-0.9), were reliably visualized. Eighty-three per cent of all coronary segments were evaluable; sensitivity, specificity, and diagnostic accuracy were 78, 91, and 89%, respectively. CONCLUSION: The combination of an imaging sequence with an intrinsically high contrast (SSFP) and a sophisticated navigator technique (affine transformation) resulted in high quality, high resolution imaging of the whole coronary arterial tree within a short examination duration. Robustness and diagnostic accuracy may allow for a routine application in the near future.

Adult↗

Diagnostic performance of digital subtraction angiography (DSA) and magnetic resonance angiography (MRA): preliminary results in vascular occlusive disease of the abdominal and lower-extremity arteries.

Fifty-nine patients with occlusive disease of the aorto-iliac and femoro-popliteal arteries were investigated prospectively by intravenous (IV) or intraarterial (IA) digital subtraction angiography (DSA) and magnetic resonance angiography (MRA). This was accomplished using a two-dimensional (2D) Inflow- (59 patients) and a 2D Phase Contrast- (RSE--rapid sequential excitation) sequence (29 patients). The spectrum of pathology included stenoses < 50%, stenoses 50-89%, stenoses 90-99%, occlusions, aneurysms and status following reconstructive surgery. MRA- and DSA-examinations were evaluated by four radiologists. The diagnoses were made by consent decisions of a radiologist and a vascular surgeon based on clinical and radiological findings. Diagnostic performance of IA-DSA was superior to all other imaging modalities. Vascular delineation of 2D Inflow-MRA was comparable to that of IV-DSA. The image quality of RSE-MRA was not adequate for diagnosis. In conclusion, 2D Inflow-MRA is a promising method for evaluating abdominal and peripheral arteriosclerotic disease. Interpretation of MR-angiograms, however, requires profound knowledge of MRA-techniques, X-ray angiography and hemodynamics.

Adult↗

The diagnostic performance of recombinant Trypanosoma cruzi ribosomal P2beta protein is influenced by its expression system.

In the present work, we have determined the effect of expression vectors and their corresponding host bacteria on the antigenic performance of Trypanosoma cruzi P2beta (TcP2beta) full-length recombinant protein. The gene encoding the TcP2beta ribosomal protein was cloned in pMAL-c2 and pET-32a vectors that allow the expression of high levels of soluble fusion proteins. A panel of 32 positive and 32 negative sera was assayed with the purified proteins expressed using pMal-c2 (TcP2beta-MBP) and pET-32a (TcP2beta-TRX) vectors and with MBP and TRX purified from pMAL-c2 and pET-32a vectors, respectively. The antigenic behavior of each TcP2beta recombinant protein differed in the diagnostic performance in terms of DI(+) (93.7 for TcP2beta-MBP vs 100% for TcP2beta-TRX), in DI(-) (90.5 for TcP2beta-MBP vs 100% for TcP2beta-TRX) and in cross-reaction with negative sera. To determine if the higher reactivity of expressed pMAL-c2 protein was due to folding during protein expression or to a steric effect related to the protein adsorption at the titration plate, the reactivity of sera against soluble proteins was assessed by ELISA inhibition assays. As each soluble protein preserved its level of reactivity, we concluded that differences in reactivity were due to intrinsic characteristics of the proteins and not to differences in patterns of adsorption to the plates.

Animals↗

Diagnostic performance of a flat-panel detector at low tube voltage in chest radiography: a phantom study.

RATIONALE AND OBJECTIVES: To evaluate a large area, cesium iodide amorphous silicon flat-panel detector (CsI/a-Si) at 3 tube voltages to detect simulated interstitial lung disease, nodules, and catheters. METHODS: Simulated interstitial lung disease, nodules, and catheters were superimposed over a chest phantom. Images were generated at 125 kVp, 90 kVp, and 70 kVp at the same surface dose and reduced effective dose equivalent for 90 kVp and 70 kVp and printed on hard copies. Fifty-four thousand observations were analyzed by receiver operating characteristic (ROC). RESULTS: Detectability of linear, miliary, reticular pattern, and nodules over lucent lung as well as of catheters and nodules over obscured chest areas increased at 90 and/or 70 kVp with higher Az values; however, only it was statistically significant for reticular pattern at 70 kVp and nodules at 90 kVp compared with 125 kVp (P < 0.05). The detection of ground-glass pattern was worse at lower kVp (P > 0.05). CONCLUSION: For most simulated patterns, differences in diagnostic performance at 70 kVp/90 kVp and 125 kVp were not significant, except for reticular pattern and nodules over lucent lung.

Cesium↗

Diagnostic performance of primary 3-dimensional computed tomography colonography in the setting of colonic diverticular disease.

BACKGROUND & AIMS: Colonic diverticular disease (CDD) is a leading cause of nondiagnostic segmental evaluation at computed tomography colonography (CTC). The primary goal of this study was to evaluate the impact of CDD on polyp detection at primary 3-dimensional (3D) CTC. METHODS: The study group consisted of 280 asymptomatic average-risk adults (mean age, 58.1 y; 167 men, 113 women). All patients underwent CTC followed by same-day optical colonoscopy with segmental unblinding (reference standard). Primary 3D endoluminal evaluation with 2-dimensional correlation was used for initial polyp detection at CTC. Without knowledge of polyp findings, all colonic segments were reviewed for the presence of CDD and graded as absent, minimal, moderate, or extensive disease. RESULTS: Moderate or extensive CDD was present in 271 (12.1%) of 2240 colonic segments and 142 (50.7%) of 280 patients. CTC performance for polyps 6 mm or larger in the presence and absence of moderate-extensive CDD was as follows: by-segment sensitivity of 90.3% (28/31) and 79.4% (123/155); by-patient sensitivity of 86.5% (64/74) and 83.1% (54/65); by-segment specificity of 97.1% (233/240) and 97.7% (1772/1814); by-patient specificity of 83.8% (57/68) and 83.6% (61/73); by-segment positive predictive value of 80.0% (28/35) and 74.5% (123/165); by-patient positive predictive value of 85.3% (64/75) and 81.8% (64/66); by-segment negative predictive value of 98.7% (233/236) and 98.2% (1172/1804); and by-patient negative predictive value of 85.1% (57/67) and 84.7% (61/72), respectively (not significant, P > or = .15). CONCLUSIONS: CDD was common in this asymptomatic screening population, but its presence did not degrade the diagnostic performance of primary 3D CTC for polyp detection.

Adenocarcinoma↗

Serum thyroxine binding capacity-dependent bias in five free thyroxine immunoassays: assessment with serum dilution experiments and impact on diagnostic performance.

OBJECTIVES: To assess the presence and magnitude of a serum thyroxine binding capacity (sBC)-dependent bias in five free thyroxine (FT(4)) immunoassays, compared with equilibrium dialysis (ED). The exhibited bias is confronted with clinical results from previous studies to evaluate its impact on FT(4) determination in sera with various sBC. DESIGN AND METHODS: The sera of three pregnant women and three non thyroidal ill (NTI) patients were serially diluted in an inert buffer to progressively decrease the sBC. FT(4) values were measured in diluted and undiluted samples with the six assays. RESULTS: As a function of increasing dilution performed on pregnancy sera, except for ED and Vitros ECi FT(4,) the other four FT(4) assay results decreased to different degrees, in the following order: two-step GammaCoat RIA< Elecsys< ADVIA:Centaur< Amerlex-MAB RIA. In sera from NTI patients, the decrease was more marked and found at high dilution with the Vitros ECi assay. Data from previous studies showed that FT(4) measured with biased assays were decreased only in samples from very severely NTI patients with low sBC and that FT(4) results in pregnancy sera with high sBC were not significantly biased. CONCLUSIONS: The dilution test is a sensitive alarm to assess sBC-dependent bias in FT(4) assays. For all FT4 assays and particularly when a bias is observed, documentation should be sought on the diagnostic performance of the assay and supported by a detailed clinical study including samples with low sBC. Physicians should still be educated about the limitations of FT(4) assays.

Blood Proteins↗

[Diagnostic performance of eosinophil protein quantification. Review].

The role of eosinophils in the pathophysiology of atopic diseases, parasitic infestations, neoplasms, and immune deficiency, among other disorders, has been demonstrated in recent years. Among eosinophil constituents we find proteins associated with membranes, cytoplasm, and granules. When the cell is activated, it can release various products, notably the basic granular proteins which have a cytotoxic effect on bronchial epithelial cells, parasite larvae, and tumoral cells: principal basic protein, eosinophil cationic protein, protein X of the eosinophil/eosinophil-derived neurotoxin, and peroxidase derived from the eosinophil. Knowledge of the biological functions of these proteins and of their concentration in different tissues is important because it reflects the role of eosinophils in the production of the histologic and clinical findings of diverse disorders. Moreover, there are now sensitive radioimmunoassays that allow measurement of these substances in different body fluids, such as serum, bronchoalveolar lavage fluid, sputum, and nasal lavage fluid. In this sense, the protein most studied has been eosinophil cationic protein, although there also are many publications on the effects of principal basic protein on bronchial epithelium and its concentration in the sputum of asthmatic patients. As regards diagnostic performance, quantitation of the granular proteins can be useful for monitoring the activity of diseases such as bronchial asthma, and it helps to predict which patients may experience a delayed asthmatic reaction after bronchial provocation with and allergen. Finally, increased serum levels of principal basic protein in the last weeks of pregnancy seem to serve as a predictive index of term gestation.

Asthma↗

A meta-analysis of the diagnostic performance of the direct agglutination test and rK39 dipstick for visceral leishmaniasis.

OBJECTIVE: To compare the performance of the direct agglutination test and rK39 dipstick for the diagnosis of visceral leishmaniasis. DATA SOURCES: Medline, citation tracking, January 1986 to December 2004. Selection criteria Original studies evaluating the direct agglutination test or the rK39 dipstick with clinical visceral leishmaniasis as target condition; adequate reference classification; and absolute numbers of true positive, true negative, false positive, and false negative observations available or derivable from the data presented. RESULTS: 30 studies evaluating the direct agglutination test and 13 studies evaluating the rK39 dipstick met the inclusion criteria. The combined sensitivity estimates of the direct agglutination test and the rK39 dipstick were 94.8% (95% confidence interval 92.7% to 96.4%) and 93.9% (87.7% to 97.1%), respectively. Sensitivity seemed higher and more homogenous in the studies carried out in South Asia. Specificity estimates were influenced by the type of controls. In phase III studies carried out on patients with clinically suspected disease, the estimated specificity of the direct agglutination test was 85.9% (72.3% to 93.4%) and of the rK39 dipstick was 90.6% (66.8% to 97.9%). CONCLUSION: The diagnostic performance of the direct agglutination test and the rK39 dipstick for visceral leishmaniasis is good to excellent and seem comparable.

Agglutination Tests↗

Diagnostic performance of multislice spiral computed tomography of coronary arteries as compared with conventional invasive coronary angiography: a meta-analysis.

OBJECTIVES: This study was designed to define the current role of multislice spiral computed tomography (MSCT) for the diagnosis of coronary artery disease (CAD) using a meta-analytic process. BACKGROUND: Multislice spiral computed tomography has recently been proposed as an alternative to conventional coronary angiography (CA) for the diagnosis of CAD. METHODS: Using Medline, we identified 29 studies (2,024 patients) evaluating CAD by means of both MSCT (> or =16 slices) and conventional CA before July 2006. After data extraction the analysis was performed according to a random-effects model. RESULTS: The per-segment analysis pooled the results from 27 studies corresponding to a cumulative number of 22,798 segments. Among unassessable segments, 4.2% were excluded from the analysis and 6.4% were classified at the discretion of the investigators, underscoring the shortcomings of MSCT. With this major limitation, the per-segment sensitivity and specificity were 81% (95% confidence interval [CI] 72% to 89%) and 93% (95% CI 90% to 97%), respectively, with positive and negative likelihood ratios of 21.5 (95% CI 13.1 to 35.5) and 0.11 (95% CI 0.06 to 0.21), respectively, and positive and negative predictive values of 67.8% (95% CI 57.6% to 78.0%) and 96.5% (95% CI 94.7% to 98.3%), respectively. As expected, the per-patient analysis has shown an increased sensitivity of 96% (95% CI 94% to 98%) but a decreased specificity of 74% (95% CI 65% to 84%). CONCLUSIONS: Multislice spiral computed tomography has shortcomings difficult to overcome in daily practice and, at the more clinically relevant per-patient analysis, continues to have moderate specificity in patients with high prevalence of CAD. Studies evaluating the diagnostic performance of the newest generation of MSCT, including patients with low to moderate CAD prevalence, will be critical in establishing the clinical role of this emerging technology as an alternative to CA.

Coronary Angiography↗

Different methods of performing diagnostic bronchoalveolar lavage in patients suffering from diffuse lung diseases.

Since 1978 transbronchial lung biopsy and diagnostic bronchoalveolar lavage were performed through the fiberoptic bronchoscope under fluoroscopic guidance in 176 patients with roentgenological signs of diffuse lung disease. The bronchoscopies were carried out under local anaesthesia with the help of various kinds of fiberoptic bronchoscopes and under general anaesthesia with the help of rigid bronchoscopic equipment. The efficiency of different methods of bronchoalveolar lavage technique was evaluated. It is more convenient to use double canal bronchoscope BF-2T "Olympus". It was possible to determine the histopathological diagnosis with the help of bronchological investigation for 126 patients out of the total number (71.6%). The highest diagnostic rate was obtained where bronchoalveolar lavage was combined with the transbronchial lung biopsy. With the help of bronchoalveolar lavage it was possible to evaluate the degree and the character of alveolitis, which is usually found in most of the cases of diffuse lung diseases, and to evaluate the efficiency of drug therapy of alveolitis in every concrete case.

Biopsy↗

Analysis of the diagnostic performance in breast cancer screening by relative operating characteristics.

In medical usage, relative operating characteristics (ROC) refer to the symptoms, signs, and laboratory values used for making a diagnosis. Diagnosis analysis by ROC measures diagnosis performance independently of the diagnostic criteria used, thus revealing the arbitrary character of diagnosis. In order to carry out ROC analysis, the diagnosis has to be graded in levels of certainty of the presence of disease (or suspicion of a lesion). When both the graded diagnosis decisions and the ultimate proof of presence or absence of disease are available, ROC analysis can easily be carried out. Analysis of 50,102 successive examinations of 19,400 women in the Utrecht breast cancer screening projects presents a remarkably good fit of the observed data with the calculated values. In the medical context even small deviations of the actual sensitivity and specificity values from the ROC curve values must be considered as signs of differences in the diagnosis procedure and should lead to further analysis of the diagnostic criteria and the examined population. Consequently the separate effect of diagnosis impairment by the mammographic risk patterns (Wolfe) on diagnostic accuracy could be isolated. The effect of age on the detection capability of breast cancer by mammography appeared to operate in narrow age groups.

Aged↗

[Evaluating the possibility of performing diagnostic and operative hysteroscopy depending on the type of hysteroscopy and agent used for filling the uterine cavity].

The aim of the paper is to present own experiences concerning diagnostic and operative hysteroscopy performed with 4 types of hysteroscopes. Flexible hysteroscope HYP 1T, rigid hysteroscope 5 mm in diameter with single flow, operative hysteroscope 8 mm in diameter with constant flow, hysteroresectoscope 9 mm in diameter with constant flow produced by Olympus; for filling the uterine cavity CO2 0.2% NaCl, 5% glucose, Purisol, Hyskon were implemented. In even case the degree of hardship of the procedure, traumatism for the patient, degree of operated-on patient's safety during the procedure, possibility of applied in the presence of bleeding, price of instrument and agents applied for filling the uterine cavity were estimated. It has been found out that the use of rigid hysteroscope 5 mm in diameter and operative hysteroscope 8 mm in diameter with constant flow and utilization of CO2 as well as Purisol and Hyskon solutions provide possibility of extensive diagnosis and therapy.

Female↗

Diagnostic performance of antineutrophil cytoplasmic antibody tests for idiopathic vasculitides: metaanalysis with a focus on antimyeloperoxidase antibodies.

OBJECTIVE: The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. METHODS: We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. RESULTS: Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. CONCLUSION: These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing.

Antibodies, Antineutrophil Cytoplasmic↗