Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “data reproducibility”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Glycated hemoglobin assessment in clinical practice: comparison of the A1cNow point-of-care device with central laboratory testing (GOAL A1C Study).

BACKGROUND: The Glycemic Optimization with Algorithms and Labs At Po1nt of Care (GOAL A1C) Study assessed the effect of titration monitoring strategies and methods of A1C testing on glycemic control in patients with type 2 diabetes failing oral therapy and beginning basal insulin glargine. The availability of both point-of-care (POC) and central laboratory A1C values provided an opportunity to evaluate correlation and statistical agreement between these methods of testing. This analysis forms the basis of the current report. METHODS: This is a 24-week, randomized, four-arm, open-label study conducted in 7,758 subjects enrolled at 2,130 sites. At baseline, patients had A1C measurements both by POC testing using the A1cNow device (Metrika, Inc., Sunnyvale, CA), which applies an immunoassay method, and by central laboratory analysis using ion exchange high-performance liquid chromatography. These measures were compared statistically. RESULTS: An r value of 0.72 was calculated for POC and laboratory A1C assessments. Although the mean POC A1C values were in agreement with the central laboratory values, there was a large range in individual POC A1C values. CONCLUSIONS: POC testing of A1C in predominantly primary care settings using the A1cNow device was correlated with central laboratory results. The correlation was less than expected based on each method's reproducibility data. Although there was agreement between the average POC A1C values and the corresponding central laboratory values, the dispersion of individual POC A1C values was large. Thus, we conclude that these two methods of A1C testing should not be used interchangeably.

Aged↗

Gas chromatographic-mass spectrometric quantification of 4-(5-)methylimidazole in roasted coffee after ion-pair extraction.

A GC-MS method is described for quantification of 4-(5-)methylimidazole (4MI) in coffee. Although tested, GC-flame ionization detection proved inadequate for this purpose due to the complexity of the coffee matrix. The developed method was based on ion-pair extraction with bis-2-ethylhexylphosphate and derivatization with isobutylchloroformate. Quantification was carried out by the standard addition method using 2-ethylimidazole as internal standard. Reproducibility data from the complete procedure are presented. Mean recoveries were higher than 98%. The method was applied to green and roasted coffee samples from the two most important varieties, arabica and robusta, and to commercial "torrefacto" coffee blends. 4MI was not detected in the green coffee samples analysed and ranged from 0.307 to 1.241 mg/kg in roasted samples.

Coffee↗

Image quality criteria in cardiology.

Image quality evaluation plays a key role in the process of optimisation in radiological procedures. Image quality criteria for cardiac cine-angiography were recently agreed as part of a European Research Project, and a scoring system based on these criteria has been developed to allow an 'objective' measurement of the quality of cardiac angiograms. Two studies aimed at the evaluation of the methodology have been completed, demonstrating that the method can be applied to cardiac images and translated into a scoring system that yields reproducible data. Based on the results of these studies, quality criteria have been further reviewed by DIMOND III panel and the updated version is presented in this paper.

Cardiology↗

AgNOR analysis of atypical ductal hyperplasia and intraductal carcinoma of the breast.

OBJECTIVE: To determine the diagnostic and prognostic value of argyrophilic nucleolar organizer regions (AgNORs) in atypical ductal hyperplasia (ADH), ductal carcinoma in situ (DCIS) and microinvasive ductal carcinoma (MDCA) of the breast. STUDY DESIGN: Image analysis of histologic sections from biopsies of 46 breast ADH and DCIS and 18 cases of MDCA. Determination of morphometric features of cell nuclei and nucleolar organizer regions by using AMBA software system. Data were compared with the estrogen receptor/progesterone receptor (ER/PR) content as well as with the growth fraction, determined immunohistochemically. RESULTS: AgNOR number and total AgNOR area increased from ADH to DCIS. The highest values were recorded in cases of DCIS with microinvasion. Differences between ADH and intraductal or microinvasive ductal carcinoma were statistically significant. Within the group of intraductal carcinomas, the lowest values were measured in the solid type and highest values in the comedo type. A correlation was found between AgNOR features and growth fraction but not between these features and ER/PR status. CONCLUSION: Selected AgNOR features are relevant for differentiation between ADH and DCIS as well as between low and high grade DCIS and microinvasive ductal carcinoma. Therefore, objective and reproducible data obtained by AgNOR analysis may allow better evaluation of the prognostic significance of these lesions.

Biomarkers, Tumor↗

EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures.

EEG-triggered functional MRI (fMRI) offers the potential to localize the generators of scalp EEG events, such as interictal epileptiform discharges, using a biological measurement as opposed to relying solely on modelling techniques. Although recent studies have demonstrated these possibilities in a small number of patients, wider application has been limited by concerns about patient safety, severe problems due to pulse-related artefact obscuring the EEG trace, and lack of reproducibility data. We have systematically studied and resolved the issues of patient safety and pulse artefact and now report the application of the technique in 24 experiments in 10 consecutive patients with localization-related epilepsy and frequent interictal epileptiform discharges (spikes or spike wave). At least two experiments were performed for each patient. In each experiment, 10- or 20-slice snapshot gradient-echo planar images were acquired approximately 3.5 s after a single typical epileptiform discharge (activation image) and in the absence of discharges (control image). Between 21 and 50 epileptiform discharges were sampled in each experiment. The significance of functional activation was tested using the t test at 95% confidence on a pixel-by-pixel basis. Six of the 10 patients showed reproducible focal changes of the blood oxygen level-dependent (BOLD) signal, which occurred in close spatial relationship to the maximum of the epileptiform discharges in the concurrent EEG. No reproducible focal BOLD signal changes were observed in the remaining four patients. In conclusion, EEG-triggered fMRI is now a sufficiently developed technique to be more widely used in clinical studies, demonstrating that it can reproducibly localize the brain areas involved in the generation of spikes and spike wave in epilepsy patients with frequent interictal discharges.

Adult↗

[Quantitative angiography: update for peripheral vascular applications].

Visual estimation of vessel diameter is unreliable and observer-dependent. With digital angiography, software for accurate quantification of arterial diameter are available. They allow: (1) selection of equipment of appropriate size (balloons, stents, etc) during revascularization procedures, (2) objective evaluation of the results of such procedures, (3) comparison between follow-up measurements and initial measurements and (4) provide reproducible data in the case of multicenter studies. The widespread availability of digital systems has been accompanied by a dramatic increase in the number of software packages for quantification. The present article reviews some of the currently available methods for quantification, presents the advantages and pitfalls of each system, and outlines their limits.

Angiography↗

Automated spectrophotometric assay for urine p-aminophenol by an oxidative coupling reaction.

Urine p-aminophenol (PAP) concentration serves as a biological marker for occupational exposures to aniline. We report the development of a rapid, simple spectrophotometric method for quantification of urine PAP concentration using a chemical autoanalyzer (Olympus Reply). The method involves oxidative coupling of PAP with an aromatic compound, xylenol, that contains an electron-donating group, based on an electrophilic aromatic substitution reaction catalyzed by sodium periodate. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. In this way, potential matrix interferences are largely avoided. The linearity range of the method is 20 to 400 mg/L. Time-course studies show that the color formation by reaction of PAP with xylenol is rapid and essentially complete within 5 min. Within-run and day-to-day reproducibility data at medium (50 mg/L) and high (200 mg/L) concentrations yield CV's <5.0%. Several prescription drugs and drugs of abuse, as well as related compounds, gave negative tests for interference in the procedure. Clinical applications of the method are illustrated by data for (a) PAP concentrations in 255 urine samples from workers at a rubber plant, and (b) PAP elimination in serial urine samples from 5 volunteers after an oral dose (500 mg) of acetaminophen. In summary, the new method has the advantages of automation, operational simplicity, and suitability for monitoring workers for exposures to aniline.

Aminophenols↗

Quantitative surface EMG of pericranial muscles. Reproducibility and variability.

We present reproducibility data on a quantitative electromyographic investigation of the temporal and frontal muscles using surface electrodes. Such data have not been published before. They constitute a necessary basis for future evaluation of the importance of pericranial muscles in tension-type headache. Root mean squares and mean rectified values of the electrical activity were measured in 20 healthy subjects. Power spectra were calculated and the mean and median frequencies were extracted. The coefficient of intraindividual variation in RMS from the right temporal muscle within the same examination was 14%, between several examinations on the same day 18% and between measurements on 2 different days 18%. The corresponding coefficients of interindividual variation were 36, 31 and 38%. The left temporal and frontal muscles showed similar coefficients of variation. At rest, no differences were found between muscles, but during maximal voluntary contraction the frontal muscle revealed a 55% lower RMS values than the temporal muscles. The method used was reproducible and reliable in measuring quantitative electrical activity of pericranial muscles.

Adult↗

Rapid determination of polyether marine toxins using liquid chromatography-multiple tandem mass spectrometry.

The diarrhetic shellfish poisoning (DSP) toxins, okadaic acid (OA), dinophysistoxins (DTX); pectenotoxin-2 (PTX2) and pectenotoxin-2 seco acids, were determined in marine phytoplankton, Dinophysis acuta, and mussels (Mytilus edulis) collected along the southwest coast of Ireland. Liquid chromatography-multiple tandem mass spectrometry (LC-MS/MS) was employed for the simultaneous determination of a series of marine toxins with large polarity differences. Separation of five DSP toxins was achieved on a C18 column (Luna-2, 150 mm x 2.1 mm, 5 microm) using an acetonitrile-water gradient with ammonium acetate as an eluent modifier. Electrospray ionisation (ESI) in negative mode, was used to generate the molecule related ion, [M-H]-, for each toxin. To develop a multiple reaction monitoring (MRM) method, fragmentation studies were performed to determine the optimum precursor-product ion combinations: OA (803/255), DTX2 (803/255), DTX1 (817/255), PTX2SAs (875/137) and PTX2 (857/137). This highly sensitive method had detection limits better than 1 pg (on-column). Linear calibrations were obtained for shellfish extracts that were spiked with toxins, OA, 0.007-1.00 microg/ml (r2 = 0.9993, N = 3) and DTX2, 0.054-8.5 microg/ml (r2 = 0.9992, N = 3). Good reproducibility data were also achieved with %RSD values (N = 3) ranging from 3.15% (0.56 microg DTX2/ml) to 5.71% (0.14 microg DTX2/ml), for shellfish extracts. The method was sufficiently sensitive to permit the determination of DSP toxins in small numbers of picked phytoplankton cells (N = 12-40). In one sample of D. acuta the average toxin composition per cell was: OA (7.0 pg), DTX2 (11 pg) and PTX2 (7.2 pg).

Chromatography, High Pressure Liquid↗

Analysis of free amino acids in green coffee beans. I. Determination of amino acids after precolumn derivatization using 9-fluorenylmethylchloroformate.

For the determination of free amino acids in green coffee beans, 9-fluorenylmethylchloroformate was applied successfully as the precolumn derivatization agent. The separation of the 27 free amino acids of green coffee as yet identified or quantitatively determined is almost complete. The paper describes in detail the conditions of extraction, derivatization and resolution and presents reproducible data of standard curves and of quantitative results. It has been demonstrated that by applying the extraction procedure described, 99.8% of the free amino acids detectable by this method are extracted. On principle, Arabica and Robusta coffees contain the same main and minor amino acids. It was possible for the first time to determine the free amino acids ornithine, beta-alanine and pipecolic acid quantitatively in Arabica and Robusta coffees as well as hydroxyproline in Arabica coffees.

Amino Acids↗

Determination of explosives in environmental water samples by solid-phase microextraction-liquid chromatography.

When explosives are present in natural aqueous media, their concentration is usually limited to trace levels. A preconcentration step able to remove matrix interferences and to enhance sensitivity is therefore necessary. In the present study, we evaluated solid-phase microextraction (SPME) technique for the recovery of nine explosives from aqueous samples using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Several parameters, including adsorption and desorption time, coating type, rate of stirring, salt addition, and pH, were optimized to obtain reproducible data with good accuracy. Carbowax coating was the only adsorbent found capable of adsorbing all explosives including nitramines. Method detection limits (MDL) were found to range from 1 to 10 microg/L, depending on the analyte. SPME/HPLC-UV coupling was then applied to the analysis of natural ocean and groundwater samples and compared to conventional solid-phase extraction (SPE/HPLC-UV). Excellent agreement was observed between both techniques, but with an analysis time around five times shorter, SPME/HPLC-UV was considered to be applicable for quantitative analysis of explosives.

Adsorption↗

Real-time PCR for simultaneous detection and genotyping of bovine viral diarrhea virus.

Since two genotypes of bovine viral diarrhea viruses (BVDV) occur in Belgian herds, their differentiation is important for disease surveillance. A quantitative real-time PCR assay was developed to detect and classify bovine viral diarrhea viruses in genotype I and II. A pair of primers specific for highly conserved regions of the 5'UTR and two TaqMan probes were designed. The FAM and VIC-labeled probe sequences differed by three nucleotides, allowing the differentiation between genotype I and II. The assay detectability of genotype I and II real-time PCR assay was 1000 and 100 copies, respectively. Highly reproducible data were obtained as the coefficients of variation of threshold cycle values in inter-runs were less than 2.2%. The correct classification of genotype I and II viruses was assessed by using reference strains and characterized field isolates of both genotypes. The application to clinical diagnosis was evaluated on pooled blood samples by post run measurement of the FAM- and VIC-associated fluorescence. The 100% agreement with the conventional RT-PCR method confirmed that this new technique could be used for routine detection of persistently infected immunotolerant animals.

Animals↗

Quantification of ovine cytokine gene expression by a competitive RT-PCR method.

A quantitative competitive RT-PCR method was developed in order to measure IL-1beta, IL-4, IL-12, IFNgamma, TNFalpha and G(3)PDH mRNA from samples of ovine tissue such as lymph node or spleen. The main advantage of the method relies on the use, for each target sequence, of an internal competitor construct similar to the relevant target, but 4-bp different in size. This competitive strategy is validated by the equivalence of the amplification process, observed separately between competitor DNA and target DNA species. Furthermore, the copy number of each cytokine cDNA is normalized to a fixed copy number of G(3)PDH cDNA. The cDNA level of this constitutive gene was effectively shown to remain constant whatever the tissue studied and independently of the experimental conditions used. The accurate and reproducible data obtained permit the application of this quantitative RT-PCR method to measure the sheep cytokine response to Salmonella infection. Early induction of IFNgamma mRNA was observed in the draining lymph node 1 day after infection. At the same time, a strong increase of IL-1beta mRNA was observed in local and systemic lymphoid organs, suggesting the initiation of the inflammatory response. Finally, the overall results demonstrate the efficiency of the method and its suitability for further studies of the immune response in the ovine species.

Animals↗

Customized molecular phenotyping by quantitative gene expression and pattern recognition analysis.

Description of the molecular phenotypes of pathobiological processes in vivo is a pressing need in genomic biology. We have implemented a high-throughput real-time PCR strategy to establish quantitative expression profiles of a customized set of target genes. It enables rapid, reproducible data acquisition from limited quantities of RNA, permitting serial sampling of mouse blood during disease progression. We developed an easy to use statistical algorithm--Global Pattern Recognition--to readily identify genes whose expression has changed significantly from healthy baseline profiles. This approach provides unique molecular signatures for rheumatoid arthritis, systemic lupus erythematosus, and graft versus host disease, and can also be applied to defining the molecular phenotype of a variety of other normal and pathological processes.

Algorithms↗

Quantification of cutaneous sclerosis with a skin elasticity meter in patients with generalized scleroderma.

BACKGROUND: The skin score, a subjective assessment of skin elasticity, is widely used in patients with systemic sclerosis. Although this scoring method is regarded as a validated and accepted tool, the interobserver and intraobserver reproducibility is relatively poor. OBJECTIVE: Our purpose was to investigate whether the recently developed SEM 474 cutometer, which exerts a controlled vacuum force to the skin, can measure skin elasticity more objectively than the skin score. METHODS: Skin elasticity was measured in 74 different body areas in patients with systemic sclerosis and compared with the skin score obtained from the same areas. RESULTS: The cutometer produced quantitative and reproducible data. A large-diameter (8 mm) measuring probe was superior to a small probe. The interobserver intraclass correlation coefficient (ICC) was 0.92; the intraobserver ICC was 0.94. A linear correlation was found with the clinical skin score; the Spearman rank correlation test was 0.69. CONCLUSION: The correlation with the skin score was reasonable, despite the observation that regional differences in skin elasticity were detected by the cutometer but not by the human observer, who automatically compensates for these factors and integrates them into the skin score. The high interobserver and intraobserver ICC makes the cutometer more suitable for quantifying changes in skin thickness than the subjective skin score.

Adult↗

A new HPLC-ELSD method to quantify indican in Polygonum tinctorium L. and to evaluate beta-glucosidase hydrolysis of indican for indigo production.

A method to quantify the indigo precursor indican (indoxyl-beta-D-glucoside) in Polygonum tinctorium L. has been developed. Plant material was extracted in deionized water, and indican was identified and quantified using high performance liquid chromatography (HPLC) coupled to an evaporative light scattering detector (ELSD). Results confirmed that with this method it is possible to measure indican content in a short time, obtaining reliable and reproducible data. Using this method, leaf indican content was quantified every 15 days during the growing season (from May to October) in P. tinctorium crops grown in a field experiment in Central Italy. Results showed that indican increased along the growing season until flowering and was positively affected by photosynthetic active radiation (PAR). Indican is naturally hydrolyzed by native beta-glucosidase to indoxyl and glucose, the indoxyl yielding indigo. The activity of two enzymes, sweet almond beta-glucosidase and Novarom G preparation, were compared with P. tinctorium native beta-glucosidase to evaluate indigo production. Results showed that the ability to promote indigo formation increased as follows: almond beta-glucosidase <or= Novarom G.

Chromatography, High Pressure Liquid↗

Standards for polysomnography in Canada. The Standards Committees of the Canadian Sleep Society and the Canadian Thoracic Society.

OBJECTIVE: To develop standards for polysomnography in Canada in order to assist in the uniform provision of diagnostic and therapeutic services related to sleep disorders. OPTIONS: Uniform testing versus no current Canadian standards. OUTCOMES: Uniform delivery of health care; reduction in number of repeat studies and their attendant costs. EVIDENCE: Availability of diagnostic laboratories and services, and survey responses (written and oral) from directors of sleep laboratories; the American Thoracic Society statement on indications and standards for cardiopulmonary sleep studies was used as a template. VALUES: Acceptable standards of practice were based on consensus opinion of the standards committees of the Canadian Sleep Society and the Canadian Thoracic Society. The committees comprised specialists in neurology, psychiatry, psychology, respirology and polysomnographic technology; family practitioners and otolaryngologists were also consulted. BENEFITS, HARMS, COSTS: Improved level of care and reduction in duplicate or unnecessary testing; establishment, with available resources, of diagnostic sleep laboratories by appropriately qualified physicians in areas where polysomnography is unavailable. RECOMMENDATIONS: Health care practitioners involved in the diagnosis and treatment of sleep disorders should possess a minimum amount of training (both clinical and research) in sleep disorders medicine. The variables recorded and findings entered in a patient's report must be relevant to the sleep disorder under investigation. The recording equipment must provide reliable, accurate and reproducible data and lend itself to appropriate calibration and quality-control procedures. Facilities for sleep studies must meet patient care safety standards, with provisions for emergency or resuscitative measures when necessary; all personnel must be trained in basic cardiopulmonary resuscitation. VALIDATION: No previous standards concerning polysomnography in Canada exist. The recommended standards were reviewed by all members of the Canadian Sleep Society and a revised document was approved by the Standards Committee of the Canadian Sleep Society and by the Standards and Executive committees of the Canadian Thoracic Society. SPONSORS: These standards are endorsed by the Canadian Sleep Society and the Canadian Thoracic Society. The cost of preparing this statement was borne by the individual members of the standards committees; no external funding was provided.

Calibration↗

Compliance with methodological standards when evaluating ophthalmic diagnostic tests.

PURPOSE: To draw attention to the importance of methodological standards when carrying out evaluations of ophthalmic diagnostic tests by reviewing the extent of compliance with these standards in reports of evaluations published within the ophthalmic literature. METHODS: Twenty published evaluations of ophthalmic screening/diagnostic tests or technologies were independently assessed by two reviewers for compliance with the following methodological standards: specification of the spectrum composition for populations used in the evaluation, analysis of pertinent subgroups, avoidance of work-up (verification) bias, avoidance of review bias, presentation of precision of results for test accuracy, presentation of indeterminate test results, and presentation of test reproducibility. RESULTS: Compliance ranged from just 10% (95%CI, 1%-32%) for presentation of test reproducibility data and avoidance of review bias to 70% (95%CI, 46%-88%) for avoidance of work-up bias and presentation of indeterminate test results. Only 5 of the 20 evaluations complied with four or more of the methodological standards and none with more than five of the standards. CONCLUSIONS: The evaluations of ophthalmic diagnostic tests discussed in this article show limited compliance with accepted methodological standards but are no worse than previously described for evaluations published in general medical journals. Adherence to these standards by researchers can improve the study design and reporting of evaluations of new diagnostic techniques. Limited compliance, combined with a lack of awareness of the standards among users of research evidence, may lead to the inappropriate adoption of new diagnostic technologies, with a consequent waste of health care resources.

Bias↗