Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “biosensing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

One-step electropolymeric co-immobilization of glucose oxidase and heparin for amperometric biosensing of glucose.

Electropolymerization was used for the co-deposition of glucose oxidase and heparin onto metal electrode transducers. Such electropolymeric co-entrapment within a non-conducting poly(1,2-phenylenediamine) (PPD) film imparts both biocatalytic and anticoagulation activities onto the transducer, and greatly improves the performance of the sensor after exposure to whole blood. Essentially identical glucose signals are observed before and after exposure to blood samples. Scanning electron micrographs after such exposure reveal no platelet deposition or formation of a fibrin "clot". The effect of the heparin co-immobilization on the glucose response is examined. Improved biocompatibility is reported also in connection with a needle-type carbon paste biosensor configuration. The simultaneous localization of the enzyme and heparin offers great promise for simplifying the preparation of enzyme electrodes and designing biocompatible implantable glucose biosensors.

Biosensing Techniques↗

Functional lipid microstructures immobilized on a gold electrode for voltammetric biosensing of cholera toxin.

Redox functionalized microstructures of diacetylene lipids containing cell surface ligand GM1 have been prepared for the construction of an electrochemical biosensor for cholera toxin from Vibrio cholerae. Incorporation of lipid molecules with disulfide functionality into the microstructures allows for firm attachment of the microstructures on a gold surface to form a sensing interface. The observed morphology of the microstructures is platelet, with size around 240 nm as determined by dynamic light scattering and transmission electron microscopy. The electrochemical response stems from electron transfer between the electrode and the redox sites on the microstructures, and the Faradaic current is influenced by the binding events of protein toxins to the ligands displayed on the crystalline surface. Electrochemical characterization indicates that electron transfer of surface ferrocene on the gold electrode is facile. Differential pulse voltammetry was used to measure the current magnitude as a function of toxin concentration, and a working range expanding from 1.0 x 10(-8) to 5.0 x 10(-7) M was obtained. Bovine serum albumin (BSA) was used as a control agent with which no interference to Faradaic response was found in the same concentration range. Atomic force microscopy (AFM) was used to characterize the morphology and distribution of microstructures on the gold surface. The effectiveness of the design for bypassing surface fouling of proteins in electrochemical detection has been demonstrated, and a binding regulated electron hopping mechanism for the observed electrochemical behavior has been proposed.

Biosensing Techniques↗

Microfluidic biosensing systems. Part I. Development and optimisation of enzymatic chemiluminescent micro-biosensors based on silicon microchips.

Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (micro-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the micro-biosensors in a microfluidic sequential injection analysis (microSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the microSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 2(3)-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 microM luminol and 150 microM PIP at a flow rate of 18 microl min(-1), the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both micro-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP micro-biosensors responded linear in a log-log format within the range 10-1000 microM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP micro-biosensors responded linear (log-log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2-3 days.

Biosensing Techniques↗

Microfluidic biosensing systems. Part II. Monitoring the dynamic production of glucose and ethanol from microchip-immobilised yeast cells using enzymatic chemiluminescent micro-biosensors.

A microfluidic flow injection (microFIA) system was employed for handling and monitoring of cell-released products from living cells immobilised on silicon microchips. The dynamic release of glucose and ethanol produced from sucrose by immobilised Saccharomyces cerevisiae cells was determined using microchip biosensors (micro-biosensors) with either co-immobilised glucose oxidase-horseradish peroxidase (GOX-HRP), or alcohol oxidase-horseradish peroxidase (AOX-HRP), catalysing a series of reactions ending up with chemiluminescence (CL) generated from HRP-catalysed oxidation of luminol in presence of p-iodophenol (PIP). The yeast cells were attached by first treating them with polyethylenimine (PEI) followed by adsorption to the microchip surface. The cell loss during assaying was evaluated qualitatively using scanning electron microscopy (SEM), showing that no cells were lost after 35 min liquid handling of the cell chip at 10 microl min(-1). The enzymes were immobilised on microchips via PEI-treatment followed by glutaraldehyde (GA) activation. The GOX-HRP micro-biosensors could be used during five days without any noticeable decrease in response, while the AOX-HRP micro-biosensors showed continuously decreasing activity, but could still be used employing calibration correction. The glucose and ethanol released from the immobilised yeast chips were quantitatively monitored, by varying the incubation time with sucrose, showing the possibilities and advantages of using a microfluidic system set-up for cell-based assays.

Biosensing Techniques↗

Synthesis, characterization and immobilization of Prussian blue nanoparticles. A potential tool for biosensing devices.

Prussian blue (PB) particles with the size of ca. 5 nm were synthesized and immobilized in a multilayer structure, as a strategy for the potential development of an amperometric transducer for oxidase-enzyme-based biosensors. Multilayer films composed of PB and poly(allylamine hydrochloride) (PAH) were prepared via layer-by-layer (LbL) sequential deposition. The process was carefully monitored by UV-vis spectroscopy and cyclic voltammetry. The increase of the redox current peaks during the layer-by-layer deposition demonstrated that charge propagation within the film occurs. Linear increase of UV-vis absorbance with the number of deposited bilayers indicates that well-organized systems have been elaborated. ITO electrodes coated with PB/PAH films were used successfully for detecting H2O2, sensitivity being dependent on the number of PB/PAH layers.

Adsorption↗

Biosensing with conically shaped nanopores and nanotubes.

In this review we consider recent results from our group that are directed towards developing "smart" synthetic nanopores that can mimic the functions of biological nanopores (transmembrane proteins). We first discuss the preparation and characterization of conical nanopores synthesized using the track-etch process. We then consider the design and function of conical nanopores that can rectify the ionic current that flows through these pores under an applied transmembrane potential. Finally, two types of sensors that we have developed with these conical nanopores are described. The first sensor makes use of molecular recognition elements that are bound to the nanopore mouth to selectively block the nanopore tip, thus detecting the presence of the analyte. The second sensor makes use of conical nanopores in a resistive-pulse type experiment, detecting the analyte via transient blockages in ionic current.

Biosensing Techniques↗

Quantitative multispectral biosensing and 1D imaging using quasi-3D plasmonic crystals.

We developed a class of quasi-3D plasmonic crystal that consists of multilayered, regular arrays of subwavelength metal nanostructures. The complex, highly sensitive structure of the optical transmission spectra of these crystals makes them especially well suited for sensing applications. Coupled with quantitative electrodynamics modeling of their optical response, they enable full multiwavelength spectroscopic detection of molecular binding events with sensitivities that correspond to small fractions of a monolayer. The high degree of spatial uniformity of the crystals, formed by a soft nanoimprint technique, provides the ability to image binding events over large areas with micrometer spatial resolution. These features, together with compact form factors, low-cost fabrication procedures, simple readout apparatus, and ability for direct integration into microfluidic networks and arrays, suggest promise for these devices in label-free bioanalytical detection systems.

Avidin↗

Building highly sensitive dye assemblies for biosensing from molecular building blocks.

Fluorescence superquenching is investigated for polyelectrolytes consisting of cyanine dye pendant polylysines ranging in number of polymer repeat units (N(PRU)) from 1 to 900, both in solution and after adsorption onto silica nanoparticles. As N(PRU) increases, the absorption and fluorescence evolve from monomer spectra to red-shifted features indicative of molecular J aggregates. In solution, the superquenching sensitivity toward an anionic electron acceptor increases by more than a millionfold over the N(PRU) range from 1 to 900. The dramatic increase is attributed to enhanced equilibrium constants for binding the quenchers, and the amplified quenching of a delocalized exciton of approximately 100 polymer repeat units. The self-assembly of monomer onto silica and clay nanoparticles leads to formation of J aggregates, and surface-activated superquenching enhanced 10,000x over the monomer in solution, indicating the formation of "self-assembled polymers" on the nanoparticle surface. Utilization of these self-assembled polymers as high-sensitivity biosensors is demonstrated.

Biosensing Techniques↗

Direct biologically based biosensing of dynamic physiological function.

Dynamic regulation of biological systems requires real-time assessment of relevant physiological needs. Biosensors, which transduce biological actions or reactions into signals amenable to processing, are well suited for such monitoring. Typically, in vivo biosensors approximate physiological function via the measurement of surrogate signals. The alternative approach presented here would be to use biologically based biosensors for the direct measurement of physiological activity via functional integration of relevant governing inputs. We show that an implanted excitable-tissue biosensor (excitable cardiac tissue) can be used as a real-time, integrated bioprocessor to analyze the complex inputs regulating a dynamic physiological variable (heart rate). This approach offers the potential for long-term biologically tuned quantification of endogenous physiological function.

Animals↗

Enhanced myocyte-based biosensing of the blood-borne signals regulating chronotropy.

Biosensors play a critical role in the real-time determination of relevant functional physiological needs. However, typical in vivo biosensors only approximate endogenous function via the measurement of surrogate signals and, therefore, may often lack a high degree of dynamic fidelity with physiological requirements. To overcome this limitation, we have developed an excitable tissue-based implantable biosensor approach, which exploits the inherent electropotential input-output relationship of cardiac myocytes to measure the physiological regulatory inputs of chronotropic demand via the detection of blood-borne signals. In this study, we report the improvement of this application through the modulation of host-biosensor communication via the enhancement of vascularization of chronotropic complexes in mice. Moreover, in an effort to further improve translational applicability as well as molecular plasticity, we have advanced this approach by employing stem cell-derived cardiac myocyte aggregates in place of whole cardiac tissue. Overall, these studies demonstrate the potential of biologically based biosensors to predict endogenous physiological dynamics and may facilitate the translation of this approach for in vivo monitoring.

Animals↗