Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “VOC”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Comparing air dispersion model predictions with measured concentrations of VOCs in urban communities.

Air concentrations of nine volatile organic compounds were measured over 48-h periods at 23 locations in three communities in the Minneapolis-St. Paul metropolitan area. Concentrations at the same times and locations were modeled using a standard regulatory air dispersion model (ISCST3). The goal of the study was to evaluate model performance by comparing predictions with measurements using linear regression and estimates of bias. The modeling, done with mobile and area source emissions resolved to the census tract level and characterized as model area sources, represents an improvement over large-scale airtoxics modeling analyses done to date. Despite the resolved spatial scale, the model did not fully capture the spatial resolution in concentrations in an area with a sharp gradient in emissions. In a census tract with a major highway at one end of the tract (i.e., uneven distribution of emissions within the tract), model predictions atthe opposite end of the tract overestimated measured concentrations. This shortcoming was seen for pollutants emitted mainly by mobile sources (benzene, ethylbenzene, toluene, and xylenes). We suggest that major highways would be better characterized as line sources. The model also failed to fully capture the temporal variability in concentrations, which was expected since the emissions inventory comprised annual average values. Based on our evaluation metrics, model performance was best for pollutants emitted mainly from mobile sources and poorest for pollutants emitted mainlyfrom area sources. Important sources of error appeared to be the source characterization (especially location) and emissions quantification. We expect that enhancements in the emissions inventory would give the greatest improvement in results. As anticipated for a Gaussian plume model, performance was dramatically better when compared to measurements that were not matched in space or time. Despite the limitations of our analysis, we found thatthe regulatory air dispersion model was generally able to predict space and time matched 48-h average ambient concentrations of VOC species within a factor of 2 on average, results that meet regulatory model acceptance criteria.

Air Movements↗

Source proximity and outdoor-residential VOC concentrations: results from the RIOPA study.

Ambient volatile organic compound concentrations outside residences were measured in Elizabeth, New Jersey as part of the Relationship of Indoor, Outdoor, and Personal A:r (RIOPA) study to assess the influence of proximity of the residences to known ambient emissions sources. The closest distances between the outdoor samplers and emission sources were determined using Geographic Information Systems (GIS)techniques. Multiple regression models were developed for residential ambient concentrations of aromatic hydrocarbons (BTEX), methyl tert butyl ether (MTBE), and tetrachloroethylene (PCE). The natural log transformed ambient concentrations of BTEX were inversely associated with distances to major roadways with high traffic densities and gasoline stations, atmospheric stability, temperature, and wind speed. Ambient MTBE levels were associated with inverse distance to gas stations and interstate highways. Residential ambient PCE concentration was inversely associated with distance to dry cleaning facilities, atmospheric stability, temperature, wind speed, and relative humidity. The linear regression models that include proximity to emission sources and meteorological variables explained 16-45% of the overall variation of ambient residential VOC concentrations. Meteorological conditions, especially atmospheric stability and temperature, explained 60-90% of the total variation in the regression models. The residential ambient air concentrations were 1.5-4 times higher than the urban background levels outside homes very close (<50 m) to ambient emission sources where approximately 7% of the population live. However, the relative increase of risk for disease is small and variations in air concentration in the background urban atmosphere are greater than those from the proximity to roadways.

Air Pollutants↗

Effects of environmental and test conditions on VOC emissions from "wet" coating materials.

In this paper, numerical simulations have been conducted to study the effects of key environmental and test conditions (air velocity, temperature, film thickness, and sample application time) on volatile organic compound (VOC) emissions from a "wet" coating material (wood stain). Simulation results indicate that air velocity and sample application time only significantly affect the emission profiles in the early stage. Film thickness, on the other hand, affects long-term emissions. Temperature can affect both the short-term and long-term emissions.

Air Movements↗

Characterization and reduction of formaldehyde emissions from a low-VOC latex paint.

The patterns of formaldehyde emission from a low volatile organic compound (VOC) latex paint applied to gypsum board were measured and analyzed by small environmental chamber tests. It was found that the formaldehyde emissions resulted in a sharp increase of chamber air formaldehyde concentration to a peak followed by transition to a long-term slow decay. A semi-empirical first-order decay in-series model was developed to interpret the chamber data. The model characterized the formaldehyde emissions from the paint in three stages: an initial "puff" of instant release, a fast decay, and a final stage of slow decay controlled by a solid-phase diffusion process that can last for more than a month. The model was also used to estimate the peak concentration and the amount of formaldehyde emitted during each stage. The formaldehyde sources were investigated by comparing emission patterns and modeling outcomes of different paint formulations. The biocide used to preserve the paint was found to be a major source of the formaldehyde. Chamber test results demonstrated that replacing the preservative with a different biocide for the particular paint tested resulted in an approximate reduction of 55% of formaldehyde emissions. But the reduction affected only the third-stage long-term emissions.

Air Pollution, Indoor↗

Measurement of diffusion coefficients of VOCs for building materials: review and development of a calculation procedure.

The measurement and prediction of building material emission rates have been the subject of intensive research over the past decade, resulting in the development of advanced sensory and chemical analysis measurement techniques as well as the development of analytical and numerical models. One of the important input parameters for these models is the diffusion coefficient. Several experimental techniques have been applied to estimate the diffusion coefficient. An extensive literature review of the techniques used to measure this coefficient was carried out, for building materials exposed to volatile organic compounds (VOC). This paper reviews these techniques; it also analyses the results and discusses the possible causes of difference in the reported data. It was noted that the discrepancy between the different results was mainly because of the assumptions made in and the techniques used to analyze the data. For a given technique, the results show that there can be a difference of up to 700% in the reported data. Moreover, the paper proposes what is referred to as the mass exchanger method, to calculate diffusion coefficients considering both diffusion and convection. The results obtained by this mass exchanger method were compared with those obtained by the existing method considering only diffusion. It was demonstrated that, for porous materials, the convection resistance could not be ignored when compared with the diffusion resistance.

Air Pollution, Indoor↗

Comparison of three small chamber test methods for the measurement of VOC emission rates from paint.

The aim of this study was to demonstrate a correlation between the measurement of emission rates of volatile organic compounds (VOCs) in three different climate chambers. In order to achieve this aim, the early state of the emission process in the three chambers was investigated and the effects of some important factors on the emission rates from paint were determined. The paper presents results of measurements in three different climate chambers. For the study, a 1-m3 chamber, a field and laboratory emission cell (FLEC), and a chamber for laboratory investigation of materials pollution and air quality (CLIMPAQ) were used. The airflow and surface area were selected so that the area-specific ventilation rates were identical in the three chambers. Temperature and relative humidity were identical during all the measurements. The paint examined was a solvent-based alkyd paint intended for indoor, which use contained between 30 and 60% of white spirit in wet condition. The paint was applied to electropolished and cleaned stainless steel plates. After application, the test material was stored for 14 days for drying in a well-ventilated conditioning room before the measurements were made. After 2 weeks storage, the most pronounced emissions were pentanal, hexanal, octanal, and decanol. The period before the emission rate stabilized differed for the three chambers studied. However, all chambers gave similar emission rates within the overall uncertainty used in these experiments.

Air Pollutants↗

Comparison of 24 h averaged VOC monitoring results for residential indoor and outdoor air using Carbopack X-filled diffusive samplers and active sampling--a pilot study.

Analytical results obtained by thermal desorption GC/MS for 24 h diffusive sampling of 11 volatile organic compounds (VOCs) are compared with results of time-averaged active sampling at a known constant flow rate. Air samples were collected with co-located duplicate diffusive sampling tubes and one passivated canister. A total of eight multiple-component sampling events took place at fixed positions inside and outside three private homes. Subsequently, a known amount of sample air was transferred from the canister to an adsorbent tube for analysis by thermal desorption GC/MS. Results for the 11 most prevalent compounds--Freon 11, 1,3-butadiene, benzene, toluene, tetrachloroethene, ethylbenzene, m,p-xylene, o-xylene, 4-ethyltoluene, 1,3,5-trimethylbenzene, and p-dichlorobenzene--show that the ratio of average study values (diffusive sampling to active sampling) is 0.92 with 0.70 and 1.14 extreme ratios. Absolute percent difference for duplicate samples using diffusive sampling was <10% for the four most prevalent compounds. Agreement between the two sampling approaches indicates that the prediction of approximately constant diffusive sampling rates based on previous laboratory studies is valid under the field conditions.

Air Pollutants↗

VOCs isotherms on day zeolite by static and dynamic methods: experiments and modelling.

A dynamic method and a static gravimetric method are respectively used to measure the adsorption equilibria of m-xylene and n-butyl acetate on Wessalith DAY zeolite F20. The equilibrium experiments are performed at different temperatures for both volatile organic compounds (VOCs). The m-xylene isotherms obtained in this study by the dynamic method are compared to our recently published data in which the static gravimetric method was used in order to test the influence of the experimental technique. Because the adsorption isotherms of m-xylene were correlated in our previous paper, in this study only the n-butyl acetate experimental data are correlated with various adsorption isotherm models: Langmuir, Toth and Dubinin equations.

Adsorption↗

Volatile Organic Compounds (VOCs) biofiltration with two packing materials.

The treatment of a gas stream containing a mixture of acetone, toluene and trichlorethylene (TCE) was tested in two biofilters packed with compost only (biofilter B1) or a mixture of pozzolan and compost (biofilter B2). The biofilter performance was evaluated at VOCs concentration of 101 mg m(-3) of acetone - 210 mg m(-3) of toluene - 89 mg m(-3) of TCE and air flow of 0.8 m(3) h(-1). Inocula were provided by the compost native microflora and microbial growth was enhanced by periodically adding an average of 150 ml of a commercial nutrient solution to each biofilter. Pollutant removal efficiencies of 100% (acetone loading of 7-13 g m(-3) h(-1)) and 80% (toluene loading of 17-21 g m(-3) h(-1)) were achieved for acetone and toluene, respectively, in biofilter B1. By comparison, these values were 100% (acetone loading of 6-11 g m(-3) h(-1)) and 90% (toluene loading 16 - 27g m(-3) h(-1) and after the complete re-moisturization of the porous medium) in biofilter B2. TCE was not eliminated in either of the biofilters tested. The compost was a good packing material which also provided a suitable microbial flora for the quick decomposition of acetone and toluene, however it was subject to clogging. Mixing this material with pozzolan solved this problem and enabled the biofilter capacity to be maintained over a long period of time.

Biodegradation, Environmental↗

VOC removal at low contaminant concentrations using granular activated carbon.

Small-scale beds of granular activated carbon (GAC) have been tested in this research using challenges of volatile organic compounds (VOCs) in air at concentrations ranging from approximately 0.5 to 100 ppm. The research linked the performance of GAC from high-concentration quickly completed tests to performance at low concentrations near those encountered indoors. For all tests, the carbon bed was approximately 2.54 cm thick and operated with a residence time of 0.11 s. The tests were conducted at 25 degrees C and 50% relative humidity. The measured 10% breakthrough times ranged from about 0.5 hour to several hundred hours. For the individual compounds, the relationship between the logarithms of breakthrough time and concentration was approximately linear over the experimental range, with different compounds producing lines having different slopes. The measured breakthrough times compared favorably to published data and models. The results suggest that higher-concentration single-component breakthrough tests, which are short and easily obtained, may be cautiously extrapolated to indoor concentrations for these compounds.

Air Pollution↗

Survey of waste comminglers' VOC exposures.

Twelve U.S. universities performing hazardous waste solvent commingling operations were surveyed for waste handler exposures to 45 U.S. Environmental Protection Agency (EPA)-designated volatile organic compounds (VOCs). Personal exposures (n = 33) and area concentrations (n = 30) were determined using gas chromatography/ mass spectrometry (GC/MS) analysis of passively collected samples. Air monitoring data were used to determine the veracity of laboratory-generated reports of waste container contents. Participants completed a questionnaire concerning the use of personal protective equipment, ventilation, and other appropriate safety equipment for their specific commingling operation. Follow-up telephone interviews were conducted to elucidate safeguards in place. Results showed that personal exposures exceeded area concentrations in 70% of operations. For the contaminant concentrations reported, 17% of personal samples exceeded Occupational Safety & Health Administration (OSHA) time-weighted average or ceiling limit values. Methylene chloride was a frequently seen airborne contaminant not listed on drum inventory sheets. When airborne constituents were compared with container content tags, 44% of the chemicals detected in air were omitted from the waste tags. This study concluded that the most frequently necessary safeguard is respiratory protection, preferably a supplied-air-type. The use of local exhaust ventilation systems rather than dilution or natural systems and facility operation in a totally explosion-safe manner are also recommended.

Data Collection↗

Behavior of the GABIE, 3M 3500, PerkinElmer Tenax TA, and RADIELLO 145 diffusive samplers exposed over a long time to a low concentration of VOCs.

Diffusive sampling is particularly suited to determine time-weighted average volatile organic compound (VOC) concentration in occupational hygiene and environmental air monitoring. The purpose of this study was to measure the sampling rate variation of four different samplers in a special use--the exposure to a low concentration of volatile organic compound (10 to 200 ppb) for a long period (1 to 14 days). PerkinElmer tube-type adsorbent was packed with Tenax TA and RADIELLO cartridge packed with Carbograph 4. Badge-type activated carbon diffusive samplers 3M 3500 and GABIE were exposed to the same controlled atmospheres of benzene as meta-xylene (BTX) during the same exposure times. Performance samplers were observed for variability of uptake rates according to concentration levels, exposure duration, back diffusion, and competition phenomena at the adsorption sites. Particular benzene behavior has been noted for the thermally desorbable tube-type diffusive sampler: the measured sampling rates decrease with time following an exponential profile. With badge-type active charcoal diffusive samplers, the uptake rates were found to be highly stable and unaffected by time exposure. Overall, in the region of a few tens of ppb, for long-time exposure and for the lightest compounds, 3M 3500 and GABIE diffusive samplers seem the most appropriate diffusive sampling technique in terms of performance and facility in use.

Adsorption↗

Traffic-related occupational exposures to PM2.5, CO, and VOCs in Trujillo, Peru.

A traffic-related exposure study was conducted among 58 workers (drivers, vendors, traffic police, and gas station attendants) and 10 office workers as controls in Trujillo, Peru, in July 2002. PM2.5 was collected, carbon monoxide (CO) was measured, volatile organic compounds (VOCs) were sampled and analyzed. Newspaper vendors had the highest full-shift CO exposures (mean +/- SD: 11.4 +/- 8.9 ppm), while office workers had the lowest (2.0 +/- 1.7 ppm). Bus drivers had the highest full-shift PM2.5 exposures (161 +/- 8.9 microg/m3), while gas station attendants (64 +/- 26.5 microg/m3) and office workers (65 +/- 8.5 microg/m3) were the lowest. Full-shift benzene/toluene/ethylbenzene/xylene exposures (BTEX) among gas station attendants (111/254/43/214 microg/m3) were much higher than those among van and taxi drivers. Several of the traffic-related occupational exposures studied were elevated and are of occupational health concern.

Air Pollutants, Occupational↗

Recent advances in measuring exhaled breath and estimating exposure and body burden for volatile organic compounds (VOCs).

An improved portable breath measurement method has been developed that allows 1-min sampling times. The equipment has been successfully tested in field and chamber studies. Results of these studies suggest that breath levels following known exposures are predictable and reproducible across a small number of volunteers. The residence times in the body and the distribution in body compartments of several common air toxics have been determined. A simple four-compartment linear model is capable of fitting the observed data. The main parameters of the model include the fraction f of the parent compound exhaled under steady-state conditions and the residence times tau i, in the tau ith compartment. The values of these parameters for several VOCs and for the four body compartments (blood, vessel-rich tissues, vessel-poor tissues, and fat) are provided.

Body Burden↗

[Biological removal of VOCs emissions].

The designed test conditions were following: vacancy velocity was from 0.7 cm/s to 3.5 cm/s, retention time was from 30 s to 80 s. Column activated carbon was selected as the filler of the reactor and toluene was taken as representative of VOCs. The biodegradation of toluene using biofilter reactor and the influence of concentration, flow and humidity on the toluene removal were investigated and the removal model was set up. The experimental results showed that the biofilter reactor had higher toluene removing ability. The observation of biotic community demonstrated that the microbes consisted of fungi, bacillus and spore bacillus. Of them spore bacillus was dominant.

Biodegradation, Environmental↗

Odour and VOC confining in large enclosures using air curtains.

Experiments were conducted on a two stream air-curtain prototype designed for VOC and odour confinement in a truck unloading area. The emphasis was placed on the air supply device. Measurements using tracer gas techniques were performed to assess the effectiveness of the system in terms of air tightness. Leakage flow rate was estimated for various feeding arrangements. Flow visualisations and particle image velocimetry measurements were carried out for a better understanding of the flow dynamics. Evidence was given of the improvements brought by the herein referred to, 'double flux' configuration in comparison to traditional designs. After a brief description of the experimental facility and the basic principle underlying the approach developed, the main results are reported and discussed and recommendations are drawn. Considerations about where the effort will be directed in future works are provided.

Air Movements↗

Ozonation of activated carbon and its effects on the adsorption of VOCs exemplified by methylethylketone and benzene.

Ozonation can modify the surface property of an activated carbon such as specific surface area, pore volume, and functional group. Results indicate that ozonation can increase the specific surface area of an activated carbon from 783+/-51 to 851+/-25 m2/g due in part to increasing micropores (those below 15 A). However, there is no change in macropore and mesopore upon ozonation. The amount of oxygen functional group (OFG) increases from 197+/-4 to 240+/-4 microeq/g, mostly in hydroxyl and carboxyl groups upon ozone treatment. These oxygen-containing functional groups are stable in the temperature range 30-250 degrees C, but begin to decompose when temperature increases beyond 300 and 350 degrees C. When the temperature reaches 1200 degrees C, all OFGs virtually disappear. The effect of ozone treatment on the adsorption of volatile organic carbon (VOC) was exemplified by methylethylketone (MEK) and benzene. The adsorption density of MEK and benzene by ozone treated activated carbon (AC(O3)) are greater than that by the untreated (AC), with MEK being more adsorbable than benzene. Results of factorial analysis indicate that physical characteristics, namely, micropore, BET surface area, pore diameter (PD), micropore volume (MV) play an important role on benzene and MEK adsorption.

Adsorption↗

Biodegradation of mixture of VOC's in a biofilter.

Volatile organic compounds(VOC' s) in air have become major concern in recent years. Biodegradation of a mixture of ethanol and methanol vapor was evaluated in a laboratory biofilter with a bed of compost and polystyrene particles using an acclimated mixed culture. The continuous performance of the biofilter was studied with different proportion of ethanol and methanol at different initial concentration and flow rates. The result showed significant removal for both ethanol and methanol, which were composition dependent. The presence of either compound in the mixture inhibited the biodegradation of the other.

Air Pollutants↗