Sulfur-functionalized olefins for titanacycle formation: tandem asymmetric cyclization and the pummerer reaction based on sulfoxides promoted by titanium(II)-to-titanium(IV) relay.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Reactions of Cp(2)TiCl(2) (Cp = eta(5)-cyclopentadienide) with 2 or 1 equiv of hybrid P-S ligands (L), (CH(3))(2)P(CH(2))(n)()S(-) (n = 2, dmpet; n = 3, dmppt), produced new dicyclopentadienyltitanium(IV) complexes with L, Cp(2)Ti(L-kappaS)(2) (1, L = dmpet; 2, L = dmppt) and [Cp(2)Ti(L-kappa(2)S,P)]BPh(4) (3, L = dmpet; 4, L = dmppt). The Ti(III) complexes, Cp(2)Ti(L-kappa(2)S,P) (5, L = dmpet; 6, L = dmppt), were prepared by the reaction of Cp(2)Ti(eta(3)-C(3)H(5)) with 1 equiv of L. The structures of complexes 1-6 were confirmed by X-ray diffraction analyses. It was found that complexes 3 and 5 were isostructural around Ti(IV) and Ti(III) centers: the Ti(IV)-S bond length in 3 (2.3498(9) A) is shorter by 0.14 A than Ti(III)-S in 5 (2.4877(7) A), while Ti(IV)-P (2.534(1) A) was merely 0.05 A shorter than Ti(III)-P (2.5844(7) A). The redox potential between 3 and 5 in acetonitrile was -1.14 V vs the ferricinium/ferrocene couple. A heterobimetallic complex that has the frame of complex 1, [Cp(2)Ti(dmpet)(2)Cu]PF(6) (7), was also isolated and structurally characterized: the Ti-Cu distance (2.95(1) A) was shorter than that in [Cp(2)Ti(SC(2)H(4)PPh(2))(2)Cu]BF(4), previously reported by White and Stephan. Structural characterization was also carried out for CpTi(dmpet-kappaS)(2)(dmpet-kappa(2)S,P) (8) and CpTiCl(2)(dmppt-kappa(2)S,P) (9), which were obtained by the reactions of Cp(or Cp)TiCl(3) (Cp = eta(5)-C(5)Me(5)(-)) with n equiv (n = 1-3) of L. The mutual site-exchange reaction between phosphorus atoms on a coordinated dmpet in the kappa(2)S,P mode and on two other coordinated dmpet's in the kappaS mode within complex 8 was analyzed by the variable-temperature (31)P[(1)H] dynamic NMR method. The kinetic parameters for this process, k(ex)(298) = 1.9 x 10(5) s(-)(1), DeltaH = 48 kJ mol(-)(1), and DeltaS = 17 J mol(-)(1) K(-)(1), as well as the rather long Ti(IV)-P distance (2.652(1) A), indicate the fluxional nature of the coordination geometry in complex 8.
M(NMe(2))(4) (M = Ti, Zr, Hf) were found to react with H(2)SiR'Ph (R' = H, Me, Ph) to yield H(2), aminosilanes, and black solids. Unusual amide hydride complexes [(Me(2)N)(3)M(mu-H)(mu-NMe(2))(2)](2)M (M = Zr, 1; Hf, 2) were observed to be intermediates and characterized by single-crystal X-ray diffraction. [(Me(2)N)(3)M(mu-D)(mu-NMe(2))(2)](2)M (1-d(2), 2-d(2)) were prepared through reactions of M(NMe(2))(4) with D(2)SiPh(2). Reactions of (Me(2)N)(3)ZrSi(SiMe(3))(3) (5) with H(2)SiR'Ph were found to give aminosilanes and (Me(2)N)(2)Zr(H)Si(SiMe(3))(3) (6). These reactions are reversible through unusual equilibria such as (Me(2)N)(3)ZrSi(SiMe(3))(3) (5) + H(2)SiPh(2) right arrow over left arrow (Me(2)N)(2)Zr(H)Si(SiMe(3))(3) (6) + HSi(NMe(2))Ph(2). The deuteride ligand in (Me(2)N)(2)Zr(D)Si(SiMe(3))(3) (6-d(1)) undergoes H-D exchange with H(2)SiR'Ph (R' = Me, H) to give 6 and HDSiR'Ph. The reaction of Ti(NMe(2))(4) with SiH(4) in chemical vapor deposition at 450 degrees C yielded thin Ti-Si-N ternary films containing TiN and Si(3)N(4). Ti(NMe(2))(4) reacts with SiH(4) at 23 degrees C to give H(2), HSi(NMe(2))(3), and a black solid. HNMe(2) was not detected in this reaction. The reaction mixture, upon heating, gave TiN and Si(3)N(4) powders. Analyses and reactivities of the black solid revealed that it contained -H and unreacted -NMe(2) ligands but no silicon-containing ligand. Ab initio quantum chemical calculations of the reactions of Ti(NR(2))(4) (R = Me, H) with SiH(4) indicated that the formation of aminosilanes and HTi(NR(2))(3) was favored. These calculations also showed that HTi(NH(2))(3) (3b) reacted with SiH(4) or H(3)Si-NH(2) in the following step to give H(2)Ti(NH(2))(2) (4b) and aminosilanes. The results in the current studies indicated that the role of SiH(4) in its reaction with Ti(NMe(2))(4) was mainly to remove amide ligands as HSi(NMe(2))(3). The removal of amide ligands is incomplete, and the reaction thus yielded "=Ti(H)(NMe(2))" as the black solid. Subsequent heating of the black solid and HSi(NMe(2))(3) may then yield TiN and Si(3)N(4), respectively, as the Ti-Si-N materials.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The title compound, [TiZr(C(5)H(11)NO(2))(3)(C(3)H(7)O)(2)], contains three methyliminodiethanolate ligands, two in different mu-oxo bridging coordination modes and one bound only to the Ti atom. The Ti and Zr atoms have distorted octahedral and pentagonal-bipyramidal coordinations, respectively, which share edges. As well as some conformational disorder in the carbon chains, there is chemical disorder at one Ti site, with a mix of n- and isopropanolate ligands.
STATEMENT OF THE PROBLEM: Titanium-ceramic bonding is less optimal than conventional metal-ceramic bonding, due to excessive oxidation of titanium during porcelain firing. PURPOSE: This in vitro study evaluated the effects of porcelain firing atmosphere and gold sputter coating on titanium surfaces on porcelain bonding to machined and as-cast titanium substrates. Material and methods Eight groups of ASTM grade 2 commercially pure (CP) titanium specimens (13 mm x13 mm x1 mm) were prepared (n=10). A conventional Au-Pd-In metal-ceramic alloy (Orion) and an ultra low-fusing porcelain (Finesse) served as the control (n=10). Forty machined titanium specimens were prepared from 1.00-mm thick titanium sheets with a diamond band saw. Forty titanium specimens were produced in a centrifugal dental titanium casting machine. All titanium specimens were airborne particle abraded with 110-microm alumina particles, whereas the control specimens were airborne particle abraded with 50-microm alumina particles. Forty titanium specimens (20 specimens each of as-cast and machined titanium) were randomly selected for gold sputter coating before ceramic firing. An ultra low-fusing porcelain (Vita Titankeramik) was fused on the central 6-mm diameter circular area on each titanium specimen. Porcelain firing environments for the titanium specimens consisted of vacuum and a reduced argon atmosphere. Porcelain was debonded by a biaxial flexure, constant strain test at a cross-head speed of 0.25 mm/min. Specimens were analyzed by standardized SEM/EDS analysis 3 times throughout the study to determine the silicon atomic percentage (Si at %): (1) after airborne particle abrasion, before porcelain application; (2) after the application of the first layer of porcelain; and (3) after the fracture of porcelain from the metal substrate. The titanium-ceramic adhesion was characterized by determining the area fraction of adherent porcelain (AFAP). Results were analyzed by analysis of variance and the Student-Newman-Keuls test (alpha=.05). RESULTS: Statistical analysis showed a significant difference in the AFAP values among all the groups. AFAP value of the control group was significantly higher (135.35 +/- 23.68) than those of the experimental groups (P<.001). For the machined titanium, AFAP value of gold sputter-coated/argon group (91.38 +/- 7.93) was significantly higher than the rest of the groups (P<.001). For the as-cast titanium fired in vacuum, significantly lower AFAP values (P<.001) were found in the gold sputter-coated group (50.2 +/- 11.26 vs 66.15 +/- 10.41). AFAP values between the argon groups with or without the gold coating were not significantly different (P=.303); however, both argon groups (93.83 +/- 4.65 and 98.09 +/- 6.35) showed significantly higher AFAP values compared with the vacuum groups (P<.001). CONCLUSION: Firing porcelain in a reduced argon atmosphere significantly improved titanium-ceramic bonding for machined and as-cast titanium. The sputter-coated gold layer on titanium provided improved titanium-ceramic bonding only when combined with firing porcelain in reduced argon atmosphere. When porcelain was fired in vacuum in the presence of the gold layer, the titanium-ceramic bonding was weakened in as-cast titanium and was not affected in machined titanium. Conventional noble metal-ceramic bonding was superior to titanium-ceramic bonding regardless of the interfacial variables examined in this study.
OBJECTIVE: This study was aimed to compare the mechanical properties of laser-welded wrought and cast titanium. METHODS: According to relevant reports and clinical demands, the specimens of TA2 were machine milled or cast into certain sizes using LZ centrifuge-vacuum-pressure titanium casting machine. This experiment involved four groups including the laser-welded wrought titanium group, the laser-welded cast titanium group, the wrought titanium group and the cast titanium group. There were 6 complete specimens in each group and the specimens were ultrasonically cleaned with ethyl and distilled water before they were welded with home-made Nd:YAG apparatus, and comparisons of mechanical properties were made among these groups. All tensile specimens were mounted on the Instron universal testing machine to test tensile loads, yield loads and absolute elongations were measured. The cross section of fractured surface was observed under S-2700 Hitachi SEM and Vickers' microhardness values in different areas were detected with AKASHI microhardness tester. RESULTS: It was showed that the tensile load of laser-welded wrought titanium made no difference from that of the original wrought titanium, but the yield load of laser-welded wrought titanium was bigger than that of the original wrought titanium. The tensile load and yield load of cast titanium were slightly bigger than those of wrought titanium. The tensile load and yield load of laser-welded wrought titanium made no statistic difference from those of laser-welded cast titanium. The absolute elongations of cast or welded titanium were lower than those of wrought or non-welded titanium. The fractured surface of cast titanium under SEM appeared lath-like structure and that of welded cast titanium honeycomb-like structure. The honeycomb-like structure of wrought titanium was more obvious than that of laser-welded wrought titanium. The microhardness value of laser-welded cast titanium was slightly bigger than that of laser-welded wrought titanium. CONCLUSION: The mechanical property of laser-welded wrought titanium might be not apparently different from that of laser-welded cast titanium.
STATEMENT OF PROBLEM: Problems with casting and porcelain bonding are encountered when titanium is used in metal-porcelain restorations. The oxidation characteristics of titanium are the main problem. The bonding mechanisms in titanium-porcelain systems are complex and poorly understood. PURPOSE: An in vitro investigation was performed to evaluate the bonding characteristics of 3 titanium-porcelain systems in various firing conditions. MATERIAL AND METHODS: This study evaluated the bonding strength of 3 commercial titanium porcelains fired in a vacuum and in an argon atmosphere to cast and noncast commercially pure titanium, using a 3-point bending test according to DIN 13927 and SEM with energy-dispersive spectrometry analysis. The results were compared with an Ni-Cr alloy and a conventional porcelain that was chosen as a control. RESULTS: The Ni-Cr-conventional porcelain system fired in an argon atmosphere had significantly higher bond strength than the other systems (P<.001). In addition, the bond strength of the titanium-spark erosion-Noritake Ti22 combination, fired in an argon atmosphere, was significantly higher than the other titanium-porcelain groups, which had results similar to those obtained with the vacuum-fired, Ni-Cr-conventional porcelain and argon-fired titanium-cast-Noritake Ti22 groups. On the other hand, the bond strength of the titanium-TiBond and titanium-Vita Titankeramik groups was below the lower limit value in the DIN 13927 standard for the 3-point bending test (25 MPa). Although the results of the Duncan multiple range test showed that firing in an argon atmosphere did not affect the bond strength of the titanium-Vita Titankeramik groups, the titanium-spark erosion-TiBond group, or the titanium-cast-Noritake Ti22 group, argon firing improved the bond strengths of the Ni-Cr-conventional porcelain group, the titanium-cast-TiBond group, and the titanium-spark erosion-Noritake Ti22 porcelain group. It was also found that there were no significant differences between the bond strengths of cast and non-cast titanium groups; an exception was the titanium TiBond groups in which the porcelain was fired in a vacuum. CONCLUSION: The oxide layer produced on titanium was considered to have a potentially adverse effect on titanium-porcelain bonding. It was also concluded that matching the titanium-porcelain combination is the main determinant for optimal bonding. Firing in an argon atmosphere that limited the oxidation of titanium improved the titanium-porcelain bond in some of the groups.
The purpose of this study was to develop titanium-silver alloys with biocompatibility, high corrosion resistance, and low ion-release rate, and to evaluate the electrochemical properties of titanium-silver alloys in artificial saliva. Titanium-silver alloys with silver contents ranging from 0 to 4.5 at % in steps of 0.5 at % were designed. The alloys were arc melted, homogenized at 950 degrees C for 72 h, hot rolled to 2 mm in thickness, and finally solution heat treated at 950 degrees C for 1 h and quenched in water. Chemical compositions, phases, hardnesses, electrochemical properties, and the cytotoxicity of the alloys were investigated. The purity of titanium-silver alloys was maintained above 99.9%, because few impurities were introduced through their manufacture. In the case of alloys containing silver in the range 2.0-4.0 at %, the formation of an acicular alpha phase was observed inside the beta phase. The acicular phase got thinner with increasing amounts of silver. This means that silver is a beta-phase stabilizing element in titanium-silver alloys. The hardness value tended to rise with increasing silver content and increased largely over 3.5 at %, and the increase of the hardness value versus pure titanium was about 33%. It is believed that the substantial increases in hardness was due to the effects of solid solution strengthening and of alpha-beta phase transition. Moreover, titanium-silver alloys had higher corrosion resistances than pure titanium. These results mean that silver additions to titanium can improve alloy corrosion resistance. Passive current densities in the potentiodynamic polarization curves were dependent on the chemical compositions of the titanium-silver alloys. However, they did not show a linear relationship with respect to silver contents. Titanium-silver alloys did not show pitting corrosion in artificial saliva. It is believed that silver addition to titanium strengthened the passive film due to titanium dissolution induced by the different electromotive forces of titanium and silver. In the agar overlay test, the cytotoxicity of the titanium-silver alloys and of titanium were none or mild. In summary, titanium-silver alloys had higher mechanical properties and corrosion resistance than titanium, and toxicities that were similar to titanium. Therefore, it is recommended that titanium-silver alloys be adopted cautiously by the biomedical and dental fields.
Biological properties of titanium implant depend on its surface oxide film. In the present study, the surface oxide films on titanium were characterized and the relationship between the characterization and bioactivity of titanium was studied. The surface oxide films on titanium were obtained by heat-treatment in different oxidation atmospheres, such as air, oxygen and water vapor. The bioactivity of heat-treated titanium plates was investigated by immersion test in a supersaturated calcium phosphate solution. The surface roughness, energy morphology, chemical composition and crystal structure were used to characterize the titanium surfaces. The characterization was performed using profilometer, scanning electronic microscopy, ssesile drop method, X-ray photoelectron spectroscopy, common Bragg X-ray diffraction and sample tilting X-ray diffraction. Percentage of surface hydroxyl groups was determined by X-ray photoelectron spectroscopy analysis for titanium plates and density of surface hydroxyl groups was measured by chemical method for titanium powders. The results indicated that heat-treatment uniformly roughened the titanium surface and increased surface energy. After heat-treatment the surface titanium oxide was predominantly rutile TiO(2), and crystal planes in the rutile films preferentially orientated in (1 1 0) plane with the highest density of titanium ions. Heat-treatment increased the amount of surface hydroxyl groups on titanium. The different oxidation atmospheres resulted in different percentages of oxygen species in TiO(2), in physisorbed water and acidic hydroxyl groups, and in basic hydroxyl groups on the titanium surfaces. The immersion test in the supersaturated calcium phosphate solution showed that apatite spontaneously formed on to the rutile films. This revealed that rutile could be bioactivated. The analyses for the apatite coatings confirmed that the surface characterization of titanium has strong effect on bioactivity of titanium. The bioactivity of the rutile films on titanium was related not only to their surface basic hydroxyl groups, but also to acidic hydroxyl groups, and surface energy. Heat-treatment endowed titanium with bioactivity by increasing the amount of surface hydroxyl groups on titanium and its surface energy.
UNLABELLED: This study revealed that osteoblasts generate harder, stiffer, and more delamination-resistant mineralized tissue on titanium than on the tissue culture polystyrene, associated with modulated gene expression, uniform mineralization, well-crystallized interfacial calcium-phosphate layer, and intensive collagen deposition. Knowledge of this titanium-induced alteration of osteogenic potential leading to enhanced intrinsic biomechanical properties of mineralized tissue provides novel opportunities and implications for understanding and improving bone-titanium integration and engineering physiomechanically tolerant bone. INTRODUCTION: Bone-titanium integration is a biological phenomenon characterized by continuous generation and preservation of peri-implant bone and serves as endosseous anchors against endogenous and exogenous loading, of which mechanisms are poorly understood. This study determines the intrinsic biomechanical properties and interfacial strength of cultured mineralized tissue on titanium and characterizes the tissue structure as possible contributing factors in biomechanical modulation. MATERIALS AND METHODS: Rat bone marrow-derived osteoblastic cells were cultured either on a tissue culture-grade polystyrene dish or titanium-coated polystyrene dish having comparable surface topography. Nano-indentation and nano-scratch tests were undertaken on mineralized tissues cultured for 28 days to evaluate its hardness, elastic modulus, and critical load (force required to delaminate tissue). Gene expression was analyzed using RT-PCR. The tissue structural properties were examined by scanning electron microscopy (SEM), collagen colorimetry and localization with Sirius red stain, mineral quantification, and localization with von Kossa stain and transmission electron microscopy (TEM). RESULTS: Hardness and elastic modulus of mineralized tissue on titanium were three and two times greater, respectively, than those on the polystyrene. Three times greater force was required to delaminate the tissue on titanium than that on the polystyrene. SEM of the polystyrene culture displayed a porous structure consisting of fibrous and globular components, whereas the titanium tissue culture appeared to be uniformly solid. Cell proliferation was remarkably reduced on titanium. Microscopic observations revealed that the mineralized tissue on titanium was composed of uniform collagen-supported mineralization from the titanium interface to the outer surface, with intensive collagen deposition at tissue-titanium interface. In contrast, tissue on the polystyrene was characterized by collagen-deficient mineralization at the polystyrene interface and calcium-free collagenous matrix formation in the outer tissue area. Such characteristic microstructure of titanium-associated tissue was corresponded with upregulated gene expression of collagen I and III, osteopontin, and osteocalcin mRNA. Cross-sectional TEM revealed the apposition of a high-contrast and well-crystallized calcium phosphate layer at the titanium interface but not at the polystyrene interface. CONCLUSIONS: Culturing osteoblasts on titanium, compared with polystyrene, enhances the hardness, elastic modulus, and interfacial strength of mineralized tissue to a higher degree. Titanium per se possesses an ability to alter cellular phenotypes and tissue micro- and ultrastructure that result in enhanced intrinsic biomechanical properties of mineralized tissue.
OBJECTIVE: Finding an optimal soldering system for a titanium prosthesis has become increasingly important with the successful introduction of titanium and titanium alloys to dentistry. This study examined the effect of corrosion on the strength of the soldered joints of pure titanium and Ti-6Al-4V alloys joined using various solders. METHODS: Commercially pure titanium and Ti-6Al-4V alloy rods (2 mm in diameter; 25 mm long) were soldered in an argon atmosphere using four solders: two kinds of titanium-based solder, a gold-based solder, and a silver-based solder. Tensile strengths were examined before or after immersion treatments. Specimens were immersed in either a 0.9% NaCl or 1.0% lactic acid solution held at 35 degrees C for 3 and 8 wk. The amounts of various metal elements released were determined by atomic absorption photospectroscopy. The natural potentials and potentiodynamic polarization behavior of the soldered specimens in 0.9% NaCl or 1.0% lactic acid were determined by a computer-assisted corrosion measurement system. The results were analyzed by ANOVA and Student's t-test. RESULTS: The cp-titanium and Ti-6Al-4V samples soldered with titanium-based solders exhibited tensile strengths of 300-400 MPa and were not significantly affected by immersion in either solution (no significant difference at p < 0.05). The strengths of both the cp-titanium and titanium alloy specimens soldered with gold-based solder were significantly lower than for any of the other specimens and were affected by immersion in the 0.9% NaCl solution (p < 0.01). The cp-titanium and Ti-6Al-4V specimens that were soldered with titanium-based solders did not show any transpassive regions or breakdown in the natural electrode potential range. On the contrary, the specimens soldered with gold-based and silver-based solders showed transpassive regions or breakdown potentials at less than 0 mV in 0.9% NaCl solution. SIGNIFICANCE: It is recommended that titanium-based solder be employed for titanium and titanium alloys.
The static and kinetic frictional coefficients of commercially pure titanium brackets were evaluated in the passive configuration in the dry and wet states against stainless steel, nickel-titanium, and beta-titanium arch wires. For comparison, stainless steel brackets were evaluated under identical conditions. Titanium brackets were grayer in color and rougher in texture than the stainless steel brackets. Bracket slots were up to 0.002 inch greater than the nominally stated values. Remarkably, the static and kinetic frictional coefficients of the couples formed by titanium and stainless steel brackets were comparable. When evaluated against stainless steel and nickel-titanium arch wires in the dry state at 34 degrees C, the static coefficient averaged.12 and.20, respectively, independent of bracket alloy. When evaluated against stainless steel and nickel-titanium wires in the wet state at 34 degrees C using human saliva, the static coefficient averaged.15 and.20, respectively, independent of bracket alloy. Only the beta-titanium arch wires increased by about 15%, when tested in either the dry or the wet state against titanium versus stainless steel brackets. Noteworthy, too, was the decrease of both coefficients in the beta-titanium wire couples from their previously reported values. Analyses of electron spectroscopy for chemical analysis spectra and depth profiles show that these new brackets are titanium only in the bulk. Indeed the immediate surfaces are composed of, at least, 80 atomic percent (at.%) carbon and oxygen; whereas, the titanium that is present (>11 at.%) is mostly in the form of titanium dioxide. The presence of this quite thin passivating layer, which resides on top of an oxygen-hardened titanium substrate, reduces the galling and fretting that would normally be expected in such materials. Pending the outcome of future angulation tests, these frictional measurements show that titanium brackets are not only comparable to stainless steel brackets but also are more biocompatible with nickel having been eliminated from their constitution.
STATEMENT OF PROBLEM: The use of titanium alloys for removable partial dentures is an increasingly popular application. While the flexibility of titanium would allow for cast clasps to be placed in deeper undercuts than advisable with cobalt-chromium, it is possible that the retentive forces of the titanium clasp might not maintain sufficient retention after repeated flexing of the clasp arm during insertion and removal of the partial denture. PURPOSE: This study assessed the characteristics of cast clasps made of titanium and titanium alloys to determine whether these materials are suitable alternatives for removable partial denture applications. MATERIAL AND METHODS: Removable partial denture clasps at two undercut depths were fabricated from commercially pure titanium, titanium alloy (Ti-6A1-4V), and cobalt-chromium. Loss of retention force was measured as the clasps underwent 3 years of simulated clinical use. The data were subjected to ANOVA and Scheffé's tests to determine differences. Evidence of casting defects and porosity was evaluated by radiographic examination and nonparametric statistics. SEM microscopy was used to observe surface characteristics that were described qualitatively. RESULTS: For the 0.75 mm undercut specimens, there was less loss of retention for clasps made from pure titanium and titanium alloy than for cobalt-chromium clasps. Porosity was more apparent in the pure titanium and titanium alloy clasps than in those made from cobalt-chromium, but the amount of porosity did not correspond to evidence of fractures or permanent deformation. CONCLUSIONS: The long-term retentive resiliency of the pure titanium and titanium alloy clasps suggests that these materials are suitable for removable partial dentures.
The purpose of this study was to evaluate the bone-bonding ability of alkali-treated titanium with and without heat treatment. Three groups of smooth titanium plate were prepared: control, or pure titanium, alkali-treated titanium, and alkali- and heat-treated titanium. The plates were inserted transcortically into the proximal metaphyses of bilateral rabbit tibiae. The tensile failure loads between implants and bones were measured at two time intervals using a detaching test. The tensile failure loads of the alkali- and heat-treated titanium group were 2.71 and 4.13 kgf, at 8 and 16 weeks, respectively, and significantly higher than those of the other titanium groups. Histological examination revealed that alkali- and heat-treated titanium was in direct contact with bone, but the other titanium groups had a thin intervening fibrous tissue. This result indicated that the alkali-treated titanium without heat treatment had no bone-bonding ability due to the unstable reactive surface layer of alkali-treated titanium. In conclusion, both alkali and heat treatment are essential for preparing bioactive titanium and this bioactive titanium is thought to be useful for orthopedic implants with cementless fixation.