Effects of endotracheal suctioning in high-frequency oscillatory and conventionally ventilated low birth weight neonates on cerebral hemodynamics observed by near infrared spectroscopy (NIRS).

Adverse changes in cerebral hemodynamics during endotracheal suctioning have been reported in conventionally ventilated newborns, whereas observations on the effect of endotracheal suctioning during high-frequency ventilation have not been reported to date. The present study was designed to investigate the effect of endotracheal suctioning on cerebral hemodynamics in high-frequency and conventionally ventilated infants. Changes in cerebral concentration of oxygenated (cO(2)Hb) and deoxygenated hemoglobin (cHHb) and oxidized cytochrome aa3 (cCyt.aa3) were measured by noninvasive near-infrared spectroscopy. In an open prospective study, 26 suctioning periods in 9 high-frequency and in 6 conventionally ventilated newborn infants were investigated. Heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MABP), and transcutaneous carbon dioxide tension (TcpCO(2)) were monitored continuously. In both groups, a marked decrease in heart rate, SaO(2) and in cO(2)Hb, an increase in cHHb, and a variable pattern in the concentration of total hemoglobin were noted during endotracheal suctioning. During suctioning, no statistically significant differences between the two methods of mechanical ventilation could be observed. We conclude that the mode of ventilation had no significant effect on changes in cerebral hemodynamics during endotracheal suctioning.

Brain↗

Effect of nasogastric suction and ranitidine on the calculated gastric intramucosal pH.

OBJECTIVE: To study the effect of nasogastric suction and ranitidine on the determination of gastric intramucosal pH (pHi). DESIGN: Prospective study. SETTING: Clinical research unit at a university hospital intensive care department. SUBJECTS: 12 healthy volunteers. INTERVENTIONS: After a 2-h measurement control period a tonometer was connected to nasogastric suction for 2 h, and thereafter ranitidine was given intravenously and gastric pHi measured. MEASUREMENTS AND RESULTS: During each 2-h measurement period gastric PCO2, gastric pHi, and pH gap were determined every 30 min. Luminal pH was measured after insertion of tonometer and at the end of each study period. Neither nasogastric suction nor ranitidine had an effect on the coefficient of variation for either gastric PCO2 or pHi. Compared to control and nasogastric suction periods, after ranitidine mean gastric pHi was higher (control 7.22 +/- 0.08; nasogastric suction 7.23 +/- 0.07; after ranitidine 7.31 +/- 0.06, p < 0.001) mean gastric PCO2 lower (control 6.4 +/- 1.3; nasogastric suction 6.5 +/- 1.3; after ranitidine 5.3 +/- 0.9, p < 0.001) and pH gap lower (control 0.18 +/- 0.08; nasogastric suction 0.17 +/- 0.05; after ranitidine 0.09 +/- 0.06, p < 0.01). Luminal pH increased after ranitidine in each subject. CONCLUSIONS: H2 blockers have no effect on the reproducibility of gastric pHi measurements, but the use of H2 blockers modifies the normal values for gastric pHi in healthy subjects.

Adult↗

Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: a study using electric impedance tomography.

OBJECTIVE: To assess lung volume and compliance changes during open- and closed-system suctioning using electric impedance tomography (EIT) during volume- or pressure-controlled ventilation. DESIGN AND SETTING: Experimental study in a university research laboratory. SUBJECTS: Nine bronchoalveolar saline-lavaged pigs. INTERVENTIONS: Open and closed suctioning using a 14-F catheter in volume- or pressure-controlled ventilation at tidal volume 10 ml/kg, respiratory rate 20 breaths/min, and positive end-expiratory pressure 10 cmH2O. MEASUREMENTS AND RESULTS: Lung volume was monitored by EIT and a modified N2 washout/-in technique. Airway pressure was measured via a pressure line in the endotracheal tube. In four ventral-to-dorsal regions of interest regional ventilation and compliance were calculated at baseline and 30 s and 1, 2, and 10 min after suctioning. Blood gases were followed. At disconnection functional residual capacity (FRC) decreased by 58+/-24% of baseline and by a further 22+/-10% during open suctioning. Arterial oxygen tension decreased to 59+/-14% of baseline value 1 min after open suctioning. Regional compliance deteriorated most in the dorsal parts of the lung. Restitution of lung volume and compliance was significantly slower during pressure-controlled than volume-controlled ventilation. CONCLUSIONS: EIT can be used to monitor rapid lung volume changes. The two dorsal regions of the lavaged lungs are most affected by disconnection and suctioning with marked decreases in compliance. Volume-controlled ventilation can be used to rapidly restitute lung aeration and oxygenation after lung collapse induced by open suctioning.

Animals↗

Acute effects of suction retraction on atrial hemodynamics and histology.

OBJECTIVES: In minimally invasive and robotic mitral valve surgery, a blade retractor is used to elevate the left atrial roof, which often distorts tissue and impairs visualization. We tested the hemodynamic and histologic changes of intra-atrial suction, using a new suction retractor that may improve stabilization and visualization. METHODS: Swine were divided into 3 equal (n = 4) groups: blade retractor, suction retractor, and arrested heart control. Left atrial ultrasonic crystals were used to record ejection fractions. After cardioplegic arrest, the atrium was opened and sampled for preretractor histology. Retractors remained in place for 1 hour, followed by postretractor histologic sampling. Controls were crossclamped for an equivalent time and postarrest histologic data obtained. Animals were weaned from bypass, data were collected for 4 hours, and postsacrifice atrial histologic samples were obtained. RESULTS: The main effect due to treatment was not statistically significant ( P = .52) between the 3 groups, with the 4-hour average ejection fraction for blade retractor, suction retractor, and control being statistically equivalent at 33.3% +/- 8.3, 35.3% +/- 12.1, and 40.8% +/- 9.9 (mean +/- standard deviation), respectively. Histology showed equivalent amounts of myocyte fragmentation, interstitial edema, eosinophilia, and wavy fibers between blade retraction and suction retraction, while the latter showed slightly increased amounts of hemorrhage. CONCLUSIONS: Atrial endocardial suction retraction appears to be safe with no acute changes in the left atrial ejection fraction or significant acute histologic differences, compared to blade retraction. Furthermore, intra-atrial suction may be applicable to procedures other than minimally invasive and robotic mitral valve repair for providing improved stabilization.

Animals↗

Suction versus water seal after thoracoscopy for primary spontaneous pneumothorax: prospective randomized study.

BACKGROUND: The objectives of the study were to review our experience of video-assisted thoracoscopic apical pleurectomy and to evaluate whether suction or water seal is superior in the postoperative treatment of primary spontaneous pneumothorax. METHODS: One hundred consecutive patients undergoing thoracoscopy for primary spontaneous pneumothorax from January 1995 to December 1999 were prospectively randomly assigned after surgery to receive suction or water seal to their chest tubes after a brief period of suction. RESULTS: There were 50 patients in each group. The two groups were evenly matched for age and operation performed. The method of management was stapling of an identified bleb or apex of the upper lobe and apical pleurectomy. Postoperative prolonged air leak longer than 5 days occurred in 8 patients (8%), 7 in the suction group and 1 in the water seal group (p = 0.03). The mean duration of chest tube days was lower in the water seal group (2.7 days) than in the suction group (3.8 days; p = 0.004). The mean hospital stay in the water seal group was 3.7 days and in the suction group it was 4.8 days (p = 0.004). Mean follow-up was 48 months (range, 30 to 60) for all patients. Pneumothorax recurred in 2 patients (2%). The recurrences occurred in the first year. CONCLUSIONS: Video-assisted thoracoscopic apical pleurectomy is effective and safe for treating primary spontaneous pneumothorax. Placing chest tubes on water seal after a brief period of suction shortens the duration of chest tube placement and hence the hospital stay.

Adolescent↗

Fluctuations in cerebral oxygenation and blood volume during endotracheal suctioning in premature infants.

To investigate the effect that suctioning of the endotracheal tube has on the cerebral circulation, we monitored brain intravascular hemoglobin saturation (tHbo2%), cerebral blood volume (CBV), and arterial hemoglobin saturation (Spo2) during suctioning in 12 infants (24 to 33 weeks of gestational age) with respiratory distress syndrome treated with mechanical ventilation. The tHbo2% and CBV values were monitored over the forebrain by dual-wavelength near-infrared spectroscopy, and Spo2 was monitored by pulse oximetry of a finger. The monitored variables were stable during the baseline period. With suctioning, Spo2 decreased from 94% +/- 1% to 84% +/- 1%, tHbo2% decreased, and CBV increased (p less than 0.05). Desaturation in the arterial and cerebral circulations began within 5 seconds of the onset of suctioning. Arterial reoxygenation began with the onset of reventilation, whereas reoxygenation in the brain was delayed by 15 seconds. The Spo2, tHbo2%, and CBV values returned to baseline within 1 minute of reventilation. Studies were repeated in six of the infants after the fraction of inspired oxygen was increased to attain a baseline Spo2 of 100%. In the preoxygenated infants, tHbo2%, CBV, and Spo2 remained constant during suctioning. These studies confirm that endotracheal suctioning results in transient hypoxemia, and demonstrate that this is reflected in the brain by vasodilation and deoxygenation. These effects are preventable by preoxygenation before suctioning.

Brain↗

Large-diameter suction tubing significantly improves evacuation time of simulated vomitus.

Current suction equipment is often inadequate at clearing the oropharynx. This study tested the hypothesis that evacuation times of simulated vomitus could be significantly improved by increasing suction tube and connection port diameters. Two standard suction systems and a new large-diameter suction system were tested. Mean evacuation times for 90 mL (an average mouthful) of three different vomitus-simulating substances--water, activated charcoal, and Progresso vegetable soup--were compared. All parameters other than suction tubing and attachment port diameters remained constant. The data were analyzed with analysis of variance and Fisher's protected least significant difference post hoc test. Use of large-diameter suction tubing significantly (P < .0001) improved evacuation time for each of the three substances. This improvement was most evident in the trials with activated charcoal and the vegetable soup, where there was a tenfold decrease in mean evacuation time. These results show that large-diameter 3/4-inch suction tubing connected to the 1-inch port is superior to the standard 1/4-inch tubing and connection ports currently used. The tenfold reduction in evacuation time of viscous and particulate materials may have important clinical implications in preventing or minimizing complications from aspiration.

Airway Obstruction↗

Large-diameter suction system reduces oropharyngeal evacuation time.

Aspiration of vomitus is associated with significant morbidity and mortality. Standard suction equipment may be incapable of rapidly evacuating vomitus from the oropharynx. In this prospective, randomized, controlled bench trial, we compared a large-diameter suction system (5/8-inch open-bore suction tip and 3/4-inch tubing attached to a 1-inch pour spout) with two standard suction systems (small-diameter blunt-nosed and medium-diameter open-bore 1/4-inch suction tips connected to 1/4-inch tubing). Mean evacuation times from the mouth of a volunteer of 90 mL of water, activated charcoal, and Progresso vegetable soup were measured. All systems removed water within 3 s. With vegetable soup, however, both standard suction systems obstructed. Despite additional mechanical scooping with the standard suction wands, the large-diameter system significantly outperformed both standard systems, by 10 s with the soup and 40 s with the charcoal The reduction in oropharyngeal evacuation times of viscous and particulate material may have important clinical implications in the emergency management of the threatened airway.

Equipment Design↗

Evidence-based suction management in accident and emergency: a vital component of airway care.

Effective airway management aims to establish and maintain a patent airway to ensure adequate alveolar ventilation and patient survival. Suction therapy must be regarded as a vital component of airway care, with all staff who are required to perform this procedure being aware of the principles of safe, effective suctioning. This paper provides an outline of the types of suction catheters available for use in the emergency care setting, and describes the safe procedures to be followed for both endotracheal and oro-pharyngeal suctioning. Potential complications are discussed other headings of respiratory, cardiovascular, immunological and traumatic, all of which are relevant to safe patient care whatever the setting, and all of which should be recognizable by any staff undertaking this procedure. The final section looks at the ways in which some of the complications can be minimized or detected by relating some of the more important theoretical points discussed throughout the paper to the practical situation. Suction therapy is not without risk for the patient and, although the frequency of suction therapy is far less in Accident and Emergency (A & E) than in the Intensive Care Unit, the potential dangers remain the same. In order to minimize some of the dangers and reduce confusion amongst staff, this paper concludes with a recommendation for a degree of standardization in suction catheter use.

Airway Obstruction↗

A prospective, randomized study of ventilator-associated pneumonia in patients using a closed vs. open suction system.

The objective of this study was to verify the incidence of nosocomial pneumonia in intubated and extended mechanically ventilated patients having endotracheal suctioning by an open vs. closed suction method aiming to decrease nosocomial pneumonia. Twenty-four (51.1%) patients received open-tracheal suction and 23 (48.9%) received closed-tracheal suction. The inclusion criteria were: surgical and medical patients older than 13 years, undergoing mechanical ventilation for more than 48 hours. Additional data were gathered using the Acute Physiology and Chronic Health Evaluation II, and details on smoking, alcoholism, diabetes mellitus, renal failure, previous lung disease, and previous use of antibiotics, steroids, H2 antagonists and antacids. Among the 24 patients having open-tracheal suction, 11 developed nosocomial pneumonia while of the 23 patients undergoing closed-tracheal suction, seven developed infection (P = 0.278). Risk factors for nosocomial pneumonia were not significantly different between the two groups. In the final logistical regression model the following variables remained: groups (open and closed) [odds ratio (OR) = 0.014; confidence interval (CI) = 0.001-0.416; P = 0.014] and use of prior antibiotics (OR = 2.297; CI = 1.244-4.242; P = 0.008). Use of a closed suction system did not decrease the incidence of nosocomial pneumonia when compared with the open system. The exogenous risk factors were the most important for acquiring this infection.

Adolescent↗

Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits.

OBJECTIVE: Reports evaluating the efficacy of heparin-bonded circuits to blunt inflammation, platelet dysfunction, and thrombin generation in response to cardiopulmonary bypass have varied. We hypothesized that this variability may in part be related to the use of cardiotomy suction, which has been demonstrated to reintroduce procoagulant and proinflammatory factors into the systemic circulation during cardiopulmonary bypass. A prospective, randomized study was undertaken to evaluate the specific effects of cardiotomy suction. METHODS: Thirty-six patients undergoing first-time, nonemergency coronary artery bypass grafting with cardiopulmonary bypass were randomly assigned to one of three treatment groups: group I, non-heparin-bonded circuits with the use of cardiotomy suction (n = 12); group II, Duraflo II (BCR-3500; Jostra Bentley Corp, Irvine, Calif) heparin-bonded circuits with cardiotomy suction (n = 12); and group III, Duraflo II heparin-bonded circuits without cardiotomy suction (n = 12). Thrombin generation, neutrophil activation (polymorphonuclear elastase), platelet activation (beta-thromboglobulin), and neuronal injury (neuron-specific enolase) were analyzed by enzyme-linked immunosorbent assays after cardiopulmonary bypass and compared with prebypass levels. Results are presented as mean +/- SEM. RESULTS: Prebypass levels of all markers were similar among treatment groups. However, postbypass levels were significantly and consistently highest in group I relative to groups II and III. Thrombin generation levels were 5.0 +/- 0.9 nmol/L in group I, 3.0 +/- 0.6 nmol/L in group II, and 1.5 +/- 0.1 nmol/L in group III (P <.05 vs group II and P <.001 vs group I). Polymorphonuclear elastase levels were 307 +/- 64 microg/L in group I, 128 +/- 24 microg/L in group II (P <.05 vs group I), and 75 +/- 14 microg/L in group III (P <.001 vs group I). beta-Thromboglobulin levels were 2692 +/- 401 IU/mL in group I, 912 +/- 99 IU/mL in group II (P =.001 vs group I), and 646 +/- 133 IU/mL in group III (P =.001 vs group I). Neuron-specific enolase levels were 9.8 +/- 0.9 ng/mL in group I, 10.5 +/- 1.6 ng/mL in group II, and 4.2 +/- 0.5 ng/mL in group III (P =.001 vs groups I and II). CONCLUSIONS: Use of cardiotomy suction resulted in significant increases in thrombin, neutrophil, and platelet activation, as well as the release of neuron-specific enolase, after cardiopulmonary bypass. Limiting increases in these markers would be best accomplished by eliminating cardiotomy suction and routinely using heparin-bonded circuits whenever possible.

Aged↗

Open and closed-circuit endotracheal suctioning in acute lung injury: efficiency and effects on gas exchange.

BACKGROUND: Closed-circuit endotracheal suctioning (CES) is advocated for preventing hypoxemia caused by the loss of lung volume resulting from open endotracheal suctioning (OES). However, the efficiency of CES and OES on tracheal secretion removal has never been compared in patients with acute lung injury. The authors designed a two-part study aimed at comparing gas exchange and efficiency between OES and CES performed at two levels of negative pressure. METHODS: Among 18 patients with acute lung injury, 9 underwent CES and OES at 3-h intervals in a random order using a negative pressure of -200 mmHg. Nine other patients underwent CES twice using two levels of negative pressure (-200 and -400 mmHg) applied in a random order. After each CES, a recruitment maneuver was performed using 20 consecutive hyperinflations. Tracheal aspirates were weighed after each suctioning procedure. Arterial blood gases were continuously recorded using an intravascular sensor. RESULTS: Open endotracheal suctioning induced a significant 18% decrease in arterial oxygen tension (Pa(O2)) (range, +13 to -71%) and an 8% increase in arterial carbon dioxide tension (Pa(CO2)) (range, -2 to +16%) that persisted 15 min after the end of the procedure. CES using -200 cm H2O did not change Pa(O2), but tracheal aspirate mass was lower compared with OES (0.6 +/- 1.0 vs. 3.2 +/- 5.1 g; P = 0.03). Increasing negative pressure to -400 cm H2O during CES did not change Pa(O2) but increased the tracheal aspirate mass (1.7 +/- 1.6 vs. 1.0 +/- 1.3 g; P = 0.02). CONCLUSIONS: Closed-circuit endotracheal suctioning followed by a recruitment maneuver prevents hypoxemia resulting from OES but decreases secretion removal. Increasing suctioning pressure enhances suctioning efficiency without impairing gas exchange.

Acute Disease↗

Real-time analysis of the change in arterial oxygen tension during endotracheal suction with a fiberoptic bronchoscope.

An intra-arterial Clark-type polarographic oxygen electrode was used with a fiberoptic bronchoscope for real-time analysis of the PO2 change during 1 min of suction in patients spontaneously breathing oxygen. There was a strong correlation between values obtained from the intra-arterial electrode (PiO2) and those from blood samples (PaO2), before and at the end of suction; the PiO2/PaO2 ratio was close to one. Continuous PiO2 recordings during suction without supplemental oxygen showed little change in the early period of suction, followed by a steep drop continuing even after suction. This drop in PiO2 was partially attenuated by providing oxygen with high-frequency jet ventilation and was almost completely attenuated by the use of a suction adaptor. Changes in the inspired oxygen concentration indicated the importance of keeping this variable constant during suction to prevent hypoxemia.

Adult↗

Ventilator-associated pneumonia using a closed versus an open tracheal suction system.

OBJECTIVE: The aim of this study was to analyze the prevalence of ventilator-associated pneumonia (VAP) using a closed-tracheal suction system vs. an open system. DESIGN: Prospective and randomized study, from October 1, 2002, to December 31, 2003. SETTING: A 24-bed medical-surgical intensive care unit in a 650-bed tertiary hospital. PATIENTS: Patients requiring mechanical ventilation for >24 hrs. INTERVENTIONS: Patients were randomized into two groups; one group was suctioned with the closed-tracheal suctioning system and another group with the open system. MEASUREMENTS: Throat swabs were taken at admission and twice a week until discharge to classify pneumonia in endogenous and exogenous. MAIN RESULTS: A total of 443 patients (210 with closed-tracheal suction system and 233 with the open system) were included. There were no significant differences between groups of patients in age, sex, diagnosis groups, mortality, number of aspirations per day, and Acute Physiology and Chronic Health Evaluation II score. No significant differences were found in either the percentage of patients who developed VAP (20.47% vs. 18.02%) or in the number of VAP cases per 1000 mechanical ventilation-days (17.59 vs. 15.84). There were also no differences in the VAP incidence by mechanical ventilation duration. At the same time, we did not find any differences in the incidence of exogenous VAP. Likewise, there were also no differences in the microorganisms responsible for pneumonia. Patient cost per day for the closed suction was more expensive than the open suction system (11.11 US dollars +/- 2.25 US dollars vs. 2.50 US dollars +/- 1.12 US dollars, p < .001). CONCLUSION: We conclude that in our study, the closed-tracheal suction system did not reduce VAP incidence, even for exogenous pneumonia.

Adult↗

Continuous needle vented foley catheter suction for urinary leak after radical prostatectomy.

PURPOSE: Prolonged urinary leakage from the urethrovesical anastomotic site after radical retropubic prostatectomy is a relatively uncommon complication. After the failure of other conservative measures we successfully overcame this problem using a Foley catheter needle vented suction technique. MATERIALS AND METHODS: Anastomotic leakage was noted after retropubic prostatectomy. After the failure of conservative techniques, including catheter traction, passive drainage and active catheter suction, needle vented suction was used. An 18 gauge needle was inserted into the plastic suction tubing attached to the Foley catheter to prevent suction occlusion of the eye of the Foley catheter by the bladder mucosa. RESULTS: Needle vented suction successfully treated urinary leakage after radical retropubic prostatectomy in 2 patients. CONCLUSIONS: In cases of prolonged anastomotic urinary leakage after radical retropubic prostatectomy needle vented suction can be considered an alternative conservative approach to treatment.

Equipment Design↗

The new NL tracheal suction catheter.

When a tube with a vacuum is approached to the surface of a liquid, a suction cone is formed and the liquid is sucked into the tube. In the new NL tracheal suction catheter, this suction cone effect is used to transport secretion into its depressed suction holes. The catheter is angle-tipped and has a U-shaped depression around a single side hole at the angle. Four large holes near the edge of the tip hole are shown to be just as effective in reducing the pulling force from the tip hole as the depression around the side hole. The new catheter was compared with three commercially available suction catheters with regard to the maximum damaging effect and the suction efficacy. The force from each suction hole pulling a flat metal base was reduced from 3 to 33 times and the efficacy in sucking was increased in relation to the other catheters when egg-white was used as model for mucus. Angle-tipped catheters are orientation-dependent. The NL catheter was the least orientation-dependent of the three angle-tipped catheters tested. Histologic examination of the mucus sucked during a clinical test showed that the NL catheter caused less tracheobronchial damage than did the Rüsch catheter.

Catheterization↗

Conjunctival changes induced by LASIK suction ring in a rabbit model.

PURPOSE: To study histopathological changes in rabbit conjunctiva after suction ring application. METHODS: A suction ring was applied to adult albino rabbit eyes (n = 30) with a vacuum pressure of 508 mm Hg for 40 s. Three rabbits were sacrificed at 3 h (3-hour group), 6 h (6-hour group), 1 day (1-day group), 3 days (3-day group), and 7 days (7-day group) after the suction ring application. Histopathological examinations included hematoxylin and eosin, Alcian blue pH 2.5-periodic acid-Schiff (AB2.5-PAS), and Alcian blue pH 1.0-periodic acid-Schiff (AB1.0-PAS) staining. TdT-dUTP-terminal nick-end labeling (TUNEL) assay and immunohistochemical staining for p65 were also performed. RESULTS: The site of suction ring application and adjacent areas did not show transient inflammation. AB2.5-PAS staining revealed that the percentage of neutral mucin was significantly different between 54.5 +/- 1.6% in the control group and 22.3 +/- 1.3% in the 7-day group (p = 0.04). Apoptosis occurred not only at the site of suction ring application, but also in adjacent regions. At all time points, conjunctival epithelium showed no positive staining for p65. CONCLUSION: The transient elevation of pressure induced by a suction ring is sufficient to cause conjunctival damage. These histological results support the finding that conjunctival damage caused by suction ring application is one of many etiologies of dry eye syndrome following laser in situ keratomileusis.

Alcian Blue↗

Prevention of endotracheal suctioning-induced alveolar derecruitment in acute lung injury.

We studied endotracheal suctioning-induced alveolar derecruitment and its prevention in nine patients with acute lung injury. Changes in end-expiratory lung volume measured by inductive plethysmography, positive end-expiratory pressure-induced alveolar recruitment assessed by pressure-volume curves, oxygen saturation, and respiratory mechanics were recorded. Suctioning was performed after disconnection from the ventilator, through the swivel adapter of the catheter mount, with a closed system, and with the two latter techniques while performing recruitment maneuvers during suctioning (40 cm H2O pressure-supported breaths). End-expiratory lung volume after disconnection fell more than with all other techniques (-1,466 +/- 586, -733 +/- 406, -531 +/- 228, -168 +/- 176, and -284 +/- 317 ml after disconnection, through the swivel adapter, with the closed system, and with the two latter techniques with pressure-supported breaths, respectively, p < 0.001), and was not fully recovered 1 minute after suctioning. Recruitment decreased after disconnection and using the swivel adapter (-104 +/- 31 and -63 +/- 25 ml, respectively), was unchanged with the closed system (-1 +/- 10 ml), and increased when performing recruitment maneuvers during suctioning (71 +/- 37 and 60 +/- 30 ml) (p < 0.001). Changes in alveolar recruitment correlated with changes in lung volume (rho = 0.88, p < 0.001) and compliance (rho = 0.9, p < 0.001). Oxygenation paralleled lung volume changes. Suctioning-induced lung derecruitment in acute lung injury can be prevented by performing recruitment maneuvers during suctioning and minimized by avoiding disconnection.

Adolescent↗