Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Silicon Compounds”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Fabrication of nickel nanocontacts using nanostencils and electron beam assisted SiO2 deposition.

Nickel nanocontacts for studying ballistic magnetoresistance have been fabricated by sputtering through FIB prepared nanostencil masks and by using electron beam assisted deposition of SiO2 to reduce the size of FIB milled pores through silicon nitride membranes. These two methods are discussed in terms of the nanocontact sizes, fabrication, and yield. The smallest size of the nanocontacts prepared using the nanostencil method was 40 nm and by the filling method was 1-2 nm. The maximum magnetoresistance measured was 1% and no evidence of a large ballistic magnetoresistance was observed.

Crystallization↗

Whisker-reinforced heat-cured dental resin composites: effects of filler level and heat-cure temperature and time.

Currently available dental resin composites are inadequate for use in large stress-bearing crown and multiple-unit restorations. The aim of this study was to reinforce heat-cured composites with ceramic whiskers. It was hypothesized that whiskers substantially strengthen heat-cured composites. It was further hypothesized that whisker filler level and heat-cure temperature and time significantly influence composite properties. Silica particles were fused onto the whiskers to facilitate silanization and to roughen the whiskers for improved retention in the matrix. The whisker filler mass fraction was varied from 0% to 79%, the heat-cure temperature from 80 degrees C to 180 degrees C, and cure time from 10 min to 24 hrs. Flexural strength, work-of-fracture, and fracture toughness of the composites were measured, and specimen fracture surfaces were examined with scanning electron microscopy. Filler level had a significant effect on composite properties. The whisker composite with 70% filler level had a flexural strength in MPa (mean +/- SD; n = 6) of 248 +/- 23, significantly higher than 120 +/- 16 of an inlay/onlay composite control and 123 +/- 21 of a prosthetic composite control (Tukey's multiple comparison test; family confidence coefficient = 0.95). Heat-cure time also played a significant role. At 120 degrees C, the strength of composite cured for 10 min was 178 +/- 17, lower than 236 +/- 14 of composite cured for 3 hrs. The strength of whisker composite did not degrade after water-aging for 100 d. In conclusion, heat-cured composites were substantially reinforced with whiskers. The reinforcement mechanisms appeared to be whiskers bridging and resisting cracks. The strength and fracture toughness of whisker composite were nearly twice those of currently available inlay/onlay and prosthetic composites.

Ceramics↗

Thermal diffusivity of composite restorative materials.

The substantial increases in the filler volume fraction of the current generation of composite resins, and the incorporation of radiopacifying heavy elements in many of these fillers, constitute significant changes which may affect thermal transport properties. Thermal diffusivity has been determined for 21 of these composite materials recommended for anterior and posterior applications. For radiopaque hybrid and for microfine composites, there was, however, only a gradual trend to increased thermal diffusivity with increasing volume fraction of inorganic filler. The diffusivity values were not greatly in excess of the level observed for dentin. Nevertheless, a small group of materials, incorporating substantial amounts of quartz or silicon nitride filler particles, exhibited high rates of thermal diffusion, up to three times the level exhibited by dentin.

Composite Resins↗

Ceramic whisker reinforcement of dental resin composites.

Resin composites currently available are not suitable for use as large stress-bearing posterior restorations involving cusps due to their tendencies toward excessive fracture and wear. The glass fillers in composites provide only limited reinforcement because of the brittleness and low strength of glass. The aim of the present study was to reinforce dental resins with ceramic single-crystalline whiskers of elongated shapes that possess extremely high strength. A novel method was developed that consisted of fusing silicate glass particles onto the surfaces of individual whiskers for a two-fold benefit: (1) to facilitate silanization regardless of whisker composition; and (2) to enhance whisker retention in the matrix by providing rougher whisker surfaces. Silicon nitride whiskers, with an average diameter of 0.4 microm and length of 5 microm, were coated by the fusion of silica particles 0.04 microm in size to the whisker surface at temperatures ranging from 650 degrees C to 1000 degrees C. The coated whiskers were silanized and manually blended with resins by spatulation. Flexural, fracture toughness, and indentation tests were carried out for evaluation of the properties of the whisker-reinforced composites in comparison with conventional composites. A two-fold increase in strength and toughness was achieved in the whisker-reinforced composite, together with a substantially enhanced resistance to contact damage and microcracking. The highest flexural strength (195+/-8 MPa) and fracture toughness (2.1+/-0.3 MPa x m(1/2)) occurred in a composite reinforced with a whisker-silica mixture at whisker:silica mass ratio of 2:1 fused at 800 degrees C. To conclude, the strength, toughness, and contact damage resistance of dental resin composites can be substantially improved by reinforcement with fillers of ceramic whiskers fused with silica glass particles.

Ceramics↗

Wear and mechanical properties of nano-silica-fused whisker composites.

Resin composites must be improved if they are to overcome the high failure rates in large stress-bearing posterior restorations. This study aimed to improve wear resistance via nano-silica-fused whiskers. It was hypothesized that nano-silica-fused whiskers would significantly improve composite mechanical properties and wear resistance. Nano-silicas were fused onto whiskers and incorporated into a resin at mass fractions of 0%-74%. Fracture toughness (mean +/- SD; n = 6) was 2.92 +/- 0.14 MPa.m(1/2) for whisker composite with 74% fillers, higher than 1.13 +/- 0.19 MPa.m(1/2) for a prosthetic control, and 0.95 +/- 0.11 MPa.m(1/2) for an inlay/onlay control (Tukey's at 0.95). A whisker composite with 74% fillers had a wear depth of 77.7 +/- 6.9 mum, less than 118.0 +/- 23.8 microm of an inlay/onlay control, and 172.5 +/- 15.4 microm of a prosthetic control (p < 0.05). Linear correlations were established between wear and hardness, modulus, strength, and toughness, with R = 0.95-0.97. Novel nano-silica-fused whisker composites possessed high toughness and wear resistance with smooth worn surfaces, and may be useful in large stress-bearing restorations.

Bisphenol A-Glycidyl Methacrylate↗

Implanted pulsatile balloon device for simulation of neurovascular compression syndromes in animals.

A self-contained neurovascular compression simulator (NCS) has been designed to function as an artificial artery that pulsates with the heart. When implanted in animals, this device simulates those naturally occurring situations in which there is compression of nervous elements in the region of the brain stem or other areas by aberrant, or ectatic branches of normal arteries. The NCS consists of an intra-aortic balloon, a smaller (cephalic) balloon, a connecting tube, and an injection port, all fabricated of polyurethane-silicone compounds. With each heart systole, the rise in intra-aortic pressure is transmitted to the smaller cephalic balloon in the form of a pulsation. Thus, part of the cardiac ejection energy is transferred to the desired nervous structures. The performance of each NCS is tested in vitro in a pulse duplicator system. The NCS was chronically implanted for up to 2 years in four dogs and 10 baboons. The cephalic balloon was placed intracranially in the subarachnoid space on the ventrolateral medulla adjacent to the entry zone of the ninth and 10th cranial nerves on the left side of baboons and on the right side of dogs. The position of the balloons was checked by fluoroscopy. Following implantation, the NCS could be inflated or deflated at will using the injection port which served to restart or discontinue the pulsations. No occlusion of the aorta or reduction of blood flow to the lower limbs or trunk was detected. By means of the NCS, an experimental model of neurogenic hypertension was produced in baboons.

Animal Diseases↗

Determination of eight volatile nitrosamines in thirty cured meat products with capillary gas chromatography-high-resolution mass spectrometry: the presence of nitrosodiethylamine and the absence of nitrosopyrrolidine.

Five samples each of six cured meat products were analysed for the presence of eight volatile nitrosamines. A combined steam distillation-extraction step at pH 8-9 plus a concentration step were used for preparation of extracts. These were analysed, without further clean-up, using a coupled capillary GC-HRMS system at a resolution of 4 000. The MS was used in the fixed mass mode, but after the retention time of each nitrosamine the mass adjustment was tuned to the mass of the next nitrosamine. This combination allowed not only an unambiguous identification of the nitrosamines but also their direct quantitative determination. The products investigated were cooked ham, fermented sausage, raw bacon, mildly fried bacon, fried minced mean and smoked meat. Only one nitrosamine, NDEA, was sometimes found to be present in relatively large amounts. It occurred in two of the bacon samples; the concentration increased during mild frying from 4 and 13 mug/kg to 16 and 43 mug/kg, respectively. It was also present in two of the smoked meat samples in amounts of 7 and 91 mug/kg, respectively. Its identity was further confirmed on a second and third capillary column also coupled to the MS, and by direct introduction of the extracts into the MS at a resolution of 15 000. A silicon compound with practically the same retention time and mass as NDMA, which originates from the antifoam agents used as shown by other investigators, was found in the extracts in amounts corresponding to abuot 2 mug/kg of product. Nevertheless, seven samples were found positively to contain NDMA in amounts of 2-6 mug/kg. NMEA, NMPA, NMBA and NDPA could not be detected in any of the samples, nor could NPip or NPy. That no NPy (i.e., less than 50 mug/kg) was found in the fried bacon samples may be due to the mild frying method used. The use only of capillary GC with a nitrogen-selective detector, without further sample clean up, would have led to many false-positive results due to the presence of other nitrogen-containing compounds.

Animals↗

[Investigation of a-SiOxNy thin film by infrared absorption].

Infrared absorptive characteristics of a-SiOxNy thin film was investigated by altering O and N content. Various molecular bonds were identified by the infrared absorption measurement. 1,105 and 865 cm-1 peaks are associated with single Si-O and Si-N modes respectively. When the O and N contents increase, the peaks associated with the symmetry and anti-symmetry modes of O-Si-O and N-Si-N are measured. For N-Si-O, the absorptive peaks of Si-O and Si-N mode are located at 1,036 and 890 cm-1 respectively.

Absorption↗

[Spectra and crystallographic sites of Ce3+ in Ca3MgSi2O8].

An efficiency purplish blue phosphor Ca3MgSi2O8:Ce3+ has been synthesized. The emission and excitation spectra of Ca3MgSi2O8:Ce3+ under 260 nm and 360 nm excitations show that they have their common broad band emission characters, but the maximums and the band widths of the emission spectra are different. The excitation spectra of Ce3+ 350 nm emission and 460 nm emission clearly show that there are remarkable differences. These results indicate that there are two kinds of Ce3+ emission centers in the host of Ca3MgSi2O8. According the analysis of the crystal structure and the Van Uitert's empirical equation, we have a conclusion that two centers occupy two kinds of octacoordinated Ca sites, respectively.

Calcium Compounds↗

[High temperature Raman spectra and structure character study of BSO crystal].

The structure character of BSO crystal at room temperature was generalized. The main Raman shifts of lattice vibration at room temperature were interpreted. The Raman spectra of BSO crystal were measured in a temperature range from 293 K to 1123 K with high temperature Raman spectroscopy and time-resolved detection techniques. Temperature-dependence character of the Raman spectra of the crystal was investigated. The vibration mode of the longest bond Bi-O(1) in crystal shifts from 542 cm(-1) to 512 cm(-1) with the temperature increasing from room temperature to 1123 K. It can be attributed to the fact that oxygen atoms are electrostatic bond to Bi atoms. The intensity of 88 cm(-1) modes, which belongs to combination mode of bending and stretching in Bi3O4 unit, changes not so noticeably as other modes, and even the 58 cm(-1) mode of Bi atoms motions in crystal lattice decreases rapidly when the temperature is higher than 873 K, which indicates that the framework structure of the crystal is broken down at high temperature, while the Bi3O4 unit still exists.

Bismuth↗

[Behaviour of indicator bacteria in microbial slime on surfaces of walls in drinkingwater-reservoirs (author's transl)].

Slime formed by microbial activity on surfaces of a tightening compound (Silicon) and Epoxid-Coating in the sphere of drinking-water does not support survival of bacteria like E. coli, S. marcescens, P. aeruginosa, S. aureus and B. subtilis. The enterobacteriaeceae remained countable over a period of nine weeks, P. aeruginosa even eighteen weeks. Whereas the grampositive Bacteria died during the short time of one week. Autoclaved slime promoted the growth of the gramnegative bacteria.

Bacillus subtilis↗

[A silica urinary calculus secondary to the absorption of gelopectose in a child].

The authors report a case of silica-containing urinary stones in a child. This drug-induced urinary stone was secondary to absorption of Gelopectose and its composition was confirmed by infrared spectrophotometry. Other cases have been diagnosed but have not yet been published. Patients with such urinary stones should be investigated for possible hypercalciuria or a disorder of H+ metabolism in the context of distal tubular acidosis, which may be incomplete and/or transient.

Feeding Behavior↗