Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polysomnography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Structure of the spontaneous all night sleep in epileptics with polysomnography.

Twenty epileptics and 11 healthy controls were investigated with polysomnography. Epileptics with interictal discharges had significantly longer total recording time and longer REM latency than the controls (P<0.05). Epileptics had a more fragmentized sleep than controls. Sleep efficiency of patients with interictal discharges was lower than that of patients without them (P<0.05). Among the patients with interictal discharges, those with partial seizures had a significantly higher arousal number than those with generalized seizures (P<0.05). The number of NREM stage shifts in patients with partial seizures tended to be higher than in those with generalized seizures.

Adult↗

Comparison of a limited computerized diagnostic system (ResCare Autoset) with polysomnography in the diagnosis of obstructive sleep apnoea syndrome.

The increasing numbers of patients referred for evaluation of suspected obstructive sleep apnoea (OSA) places a growing burden on available sleep laboratory resources. A number of limited diagnostic systems have been developed in an effort to cope with this clinical problem. In this study, the diagnostic capabilities of one limited diagnostic system (ResCare Autoset) were compared with full polysomnography (PSG), using the Oxford SAC computerized system. Thirty six patients with suspected OSA had simultaneous studies performed both with the Autoset and Oxford PSG systems. The apnoea plus hypopnoea index (AHI) (events x h(-1)) scored by the Autoset system was compared with the AHI scored from the PSG raw tracings by an experienced sleep technician. There were highly significant correlations between the Autoset AHI and the AHI scored by the manual PSG scoring method (r=0.92; p<0.001). The positive predictive value for diagnosis of OSA for the Autoset was 86% when compared with manual PSG scoring, based on an AHI threshold for OSA of 15 events x h(-1). However, the agreement between Autoset and PSG was poor in severe cases of OSA, although not sufficiently so as to result in mistaken diagnosis in any of these cases. We conclude that the Autoset system is a sensitive and easy to use system, which facilitates screening for obstructive sleep apnoea with a reasonable degree of accuracy.

Airway Obstruction↗

Obstructive sleep apnoea syndrome: is the "half-night polysomnography" an adequate method for evaluating sleep profile and respiratory events?

Recently, to reduce the costs of polysomnography, split-night studies have been introduced into routine practice: the first part of the night is used to make the diagnosis of obstructive sleep apnoea syndrome (OSAS) and the second part to achieve an appropriate level of continuous positive airway pressure. Since this split-night protocol has not yet been validated by the comparison of polysomnographic pictures obtained in the first and second parts of the night, the aim of this study was to evaluate sleep profile and respiratory disturbances in the first part (PSG1) and second (PSG2) portion of a standard full-night polysomnographic examination (PSGtot) in a group of OSAS patients. Twenty nine consecutive OSAS patients, aged 54+/-10 yrs; body mass index (BMI) 40+/-6 kg x m(-2) (mean+/-SD values), were studied by separate analyses of PSG1, PSG2 and PSGtot. PSG1 was found to have a low sensitivity value (66%). A significant difference was found between apnoea-hypopnoea indices (AHI) recorded in PSG1, PSG2 and PSGtot (mean+/-SD, AHI1 33+/-27, AHI2 45+/-28, AHItot 40+/-25 events x h(-1), respectively; p<0.01). A strong correlation was observed between AHItot and AHI1 (r=0.89) and between AHItot and AHI2 (r=0.92), but a weaker correlation between AHI1 and AHI2 (r=0.66). These correlations became weaker when patients were subdivided into two different classes on the basis of disease severity. PSG1 was representative of PSGtot and similar to PSG2 only in those patients with rapid eye movement (REM) phase sleep in the first part of the night. We conclude that split-night protocols are not appropriate for evaluating sleep-disordered breathing in obstructive sleep apnoea syndrome patients when rapid eye movement phase sleep does not occur in the first part of the night.

Adult↗

Actigraphy correctly predicts sleep behavior in infants who are younger than six months, when compared with polysomnography.

Actigraphy has been widely used in adults and children. In infants, validation of actigraphy has typically used a comparison with behaviorally determined sleep state classification rather than polysomnography (PSG). This study validated actigraphy against PSG for determining sleep and waking states in infants who were younger than 6 mo. Twenty-two healthy infants, 13 term and 9 preterm, were studied at three different matched postconceptional ages. Actigraph data were compared with PSG recordings in 1-min epochs. Agreement rate (AR), predictive value for sleep, predictive value for wake, sensitivity. and specificity were calculated and compared between activity thresholds and across ages with two-way ANOVA for repeated measures. Thirty-two validation studies were analyzed. Overall AR with PSG of 93.7 +/- 1.3 and 91.6 +/- 1.8 were obtained at 2-4 wk and 5-6 mo, respectively, at the low activity threshold setting, whereas the auto activity threshold gave the best agreement with PSG at 2-4 mo (AR 89.3 +/- 1.3%). Sensitivity values of 96.2 +/- 1.1% at 2-4 wk, 91.2 +/- 1.5% at 2-4 mo, and 94.0 +/- 1.9% were obtained at these same settings. There was no difference across ages in AR or sensitivity. PVW and specificity values were low in this study. We conclude that actigraphy is a valid method for monitoring sleep in infants who are younger than 6 mo.

Analysis of Variance↗

Bipolar deep brain stimulation permits routine EKG, EEG, and polysomnography.

As the population of patients treated with deep brain stimulation (DBS) grows and the patients age, more will require routine or emergent electrophysiologic tests. DBS artifact may render these uninterpretable, whereas stopping DBS may release symptoms that confound evaluation. The authors find that monopolar, but not bipolar, stimulation produces significant artifact during EKG, EEG, and polysomnography.

Aged↗

Omission of polysomnography in treatment of snoring: common reasons and medico-legal implications.

Although polysomnography (PSG) is an important investigation in the treatment of snorers, it was observed that a large number of patients did not have pre-operative PSG assessment in a tertiary hospital in Singapore. Of the 118 Asian patients who underwent surgery for snoring from January 1997 to December 1998, 36 (30.5 per cent) of patients did not have pre-operative PSG and only 21 (17.8 per cent) of patients had post-operative PSG. In this cohort, 43 (36.4 per cent) patients presented with snoring as their only complaint and not associated with symptoms indicative of obstructive sleep apnoea syndrome (OSAS). Thirty-one of these 'simple snorers' underwent sleep studies with the following outcome: two (6.5 per cent) true simple snorers, two (6.5 per cent) upper airway resistance syndrome, nine (29 per cent) mild OSAS, seven (22.6 per cent) moderate OSAS and 11 (35.5 per cent) severe OSAS. Our study showed that without the aid of PSG, it would be difficult to predict the severity of sleep apnoea based on clinical history alone. In an increasingly litigation-conscious society such as Singapore, there is therefore little justification in omitting PSG in the treatment of snoring. The common reasons for omission of pre-operative PSG and the medico-legal implications are also discussed.

Adult↗

Predicting sleep apnea and excessive day sleepiness in the severely obese: indicators for polysomnography.

BACKGROUND: Obstructive sleep apnea (OSA) is common in severely obese subjects (body mass index [BMI] > 35). Overnight polysomnography (OPS) is the "gold standard" method of evaluating this condition; however, it is time-consuming, inconvenient, and expensive. Selection of patients for OPS would be enhanced if we could better predict those likely to have clinically significant OSA. STUDY OBJECTIVE: To look for clinical and biochemical predictors of OSA in symptomatic patients presenting for obesity surgery. DESIGN AND PATIENTS: Symptoms suggestive of OSA were sought in a structured interview. We report OPS results of 99 consecutive subjects in whom OSA was clinically suspected. Predictors of apnea-hypopnea index (AHI) were sought from an extensive preoperative data collection. Multivariate linear and logistic analysis was used to identify independent predictors of AHI. RESULTS: Symptoms were poor predictors of AHI, with observed sleep apnea the only positive predictor. Four clinical and two biochemical factors independently predicted AHI: observed sleep apnea, male sex, higher BMI, age, fasting insulin, and glycosylated hemoglobin A(Ic) (r(2) = 0.42). Neck circumference (the best single measure) could replace BMI and sex in the analysis (r(2) = 0.43). With cutoffs selected, a simple scoring system using these six factors provides a method of predicting those with moderate or severe OSA. A score > or = 3 provides a sensitivity and specificity of 89% and 81%, and 96% and 71% for AHIs of > or = 15 and > or = 30, respectively. None of the 31 subjects with scores of 0 or 1 were found to have an AHI > or = 15. CONCLUSION: We explore sleep disturbance and report a simple method of predicting OSA in severely obese symptomatic subjects. This should assist in limiting the use of OPS to those with greater risk and provide a method of assessing risk in those not presenting primarily with a sleep problem.

Adult↗

Death during polysomnography of a patient with cheyne-stokes respiration, respiratory acidosis, and chronic heart failure.

A patient with chronic heart failure and chronic respiratory failure (CRF) underwent ambulatory polysomnography at home. She was found dead on the morning after the recording. The tracings confirmed severe sleep apnea syndrome. After 8 h of incessant Cheyne-Stokes respiration during sleep, respiratory arrest occurred, followed 7 min later by asystole. This report illustrates a case of respiratory drive failure during sleep as the mode of death in a patient with heart failure, sleep apnea syndrome, and CRF.

Acidosis, Respiratory↗

Prevalence of positional sleep apnea in patients undergoing polysomnography.

STUDY OBJECTIVES: The primary aim of this study was to determine the prevalence of positional obstructive sleep apnea using a functional definition. Positional sleep apnea was defined as a total apnea-hypopnea index (AHI) > or = 5 with a > 50% reduction in the AHI between the supine and nonsupine postures, and an AHI that normalizes (AHI < 5) in the nonsupine posture. A secondary aim was to determine if positional sleep apnea can be diagnosed accurately during a split-night study. DESIGN: Retrospective chart review. SETTING: Two sleep centers in Buffalo, NY, one a Veterans Affairs Western New York Healthcare System Sleep Center (VAWNY) and the other a freestanding ambulatory center (Associated Sleep Center [ASC]). PATIENTS: Three hundred twenty-six patients from the VAWNY, including 57 patients who underwent a split-night study and 242 patients from the ASC who underwent polysomnography. INTERVENTIONS: None. MEASUREMENTS: Patient characteristics and sleep study results. RESULTS: Positional sleep apnea was seen in 49 of 99 patients (49.5%) with mild sleep apnea (AHI, 5 to 15/h), 14 of 72 patients (19.4%) with moderate sleep apnea (AHI, 15 to 30/h), and 5 of 77 patients (6.5%) with severe sleep apnea (AHI > 30/h). Sufficient sleep (> 15 min) in both postures was not seen in 104 of 269 patients (38.7%) and 80 of 242 overnight studies (33.1%) at the VAWNY and ASC, respectively, and was not seen in 47 of 57 split-night studies (82.5%). The percentage of studies with insufficient sleep in both postures was significantly greater for split-night studies (p < 0.0001). CONCLUSIONS: Positional sleep apnea is common particularly in patients with mild disease. Positional sleep apnea cannot usually be assessed during a split-night study.

Adult↗

Effects of cisapride on corrected QT interval, heart rate, and rhythm in infants undergoing polysomnography.

OBJECTIVE: To evaluate the effects of cisapride, a prokinetic gastrointestinal drug, on the electrocardiographic QT interval, heart rate, and rhythm in infants during routine 8-hour polysomnography. Reported electrocardiogram (ECG) and rhythm disturbances in a small number of patients with the use of cisapride provided the impetus for this prospective study. STUDY DESIGN: Two hundred fifty-two infants born at term were enrolled. Of these, 134 were on cisapride therapy for suspected gastroesophageal reflux and 118 were not on cisapride and served as controls. Cisapride-treated and control infants were from the outset divided into 3 age groups; group 1: under 3 months of age; group 2: between 3 and 6 months of age; and group 3: >6 months of age. Continuous ECG bipolar limb lead I recording, saturation monitoring, and electroencephalography were conducted. QT intervals and heart rate were measured at hourly intervals. RESULTS: Cisapride doses were: group 1 mean, 0.80 mg/kg/day (range: 0.38-1.55); group 2 mean, 0.80 mg/kg/day (range: 0. 23-1.38); and group 3 mean, 0.72 mg/kg/day (range: 0.32-1.41). Heart rate was higher in the younger infants, with a gradual decrease with age. No difference in heart rate was detected between the cisapride and control groups. The QTc interval in patients in group 1 was statistically longer than the controls, when applying both Bazett's and Hodges' formulae for QT correction. The other age groups did not differ. No arrhythmia or atrioventricular conduction abnormalities were observed. CONCLUSION: Infants under 3 months of age on cisapride treatment had significantly longer QTc intervals (with Bazett's formula, the 98th percentile was 504 ms in the cisapride group vs 447 ms in controls). The clinical significance and risk of the increased QTc interval in these infants are unclear and need further evaluation and risk stratification. Meanwhile, cisapride should be judiciously prescribed in infants <3 months of age.

Arrhythmias, Cardiac↗

Discrepancy in polysomnography scoring for a patient with obstructive sleep apnea hypopnea syndrome.

Overnight polysomnography (PSG) is indispensable for diagnosis of obstructive sleep apnea hypopnea syndrome. However, studies on interscorer agreement on PSG scoring between laboratories are few. The purpose of this study was to examine the reliability of interscorer agreement on PSG scoring among 16 sleep laboratories in Japan. We found a relatively moderate interscorer reliability of the index of oxygen desaturation and arousal during sleep, but a relatively low reliability of the index of transient reduction in and complete cessation of breathing (apnea hypopnea index). The median rate of interscorer coincidence of sleep staging was the lowest for slow wave (deep) sleep (23.5%), followed by those for Stage 1 (59.8%), Wake (73.2%) and Stage 2 (74.2%) in this order, and rapid eye movement was the most reliably identified stage (91.3%). The median rate of interscorer coincidence for all stages was 71.8%. The present study demonstrates that scorers tend to analyze PSG data according to a relatively empirical decision as opposed to a rule-dependent decision. Further detailed scoring manuals are required to decrease the interscorer discrepancy in PSG scoring.

Adult↗

Client perceptions of the polysomnography experience and compliance with therapy.

A grounded theory approach was used to generate theory about clients' perceptions of polysomnography, and the relationships between these perceptions and compliance with therapy. Interviews were conducted with two groups of clients: those who complied with recommended therapy (Continuous Positive Airways Pressure) and those who did not. Compliance with suggested therapy appeared to be related to the degree of benefit derived by the client. In addition, there were problems with the process of diagnosis and follow-up that impacted on client satisfaction and may have influenced their compliance. These findings have highlighted issues which have been used to generate theories that will be tested in future research.

Aged↗

[Behavior disorder of the REM sleep in 2 documented cases with polysomnography].

We report a 69 years old male with a parkinsonian syndrome and a 50 years old female without neurological problems who showed violent behavior during REM sleep. Polysomnography showed that both bad tonic or phasic muscular activity during REM sleep and a REM sleep behavior disorder was diagnosed. Clonazepam was used in both, with good clinical response. This condition is frequently unrecognized and confused with nightmares, nocturnal delirium or other parasomnias.

Aged↗

Identifying montages that best detect electrographic seizure activity during polysomnography.

STUDY OBJECTIVES: Recognizing epileptic seizures during video polysomnography (VPSG) can be challenging, particularly when using standard, limited EEG montages and paper speed. Few sleep laboratories have PSG equipment that allows for the recording of 18 channels of EEG without compromising the ability to detect sleep apnea, periodic limb movements, and parasomnias. We studied the ability of sleep medicine- and EEG-trained polysomnographers to correctly identify epileptic seizures during PSG using 4, 7, and 18 channels of simultaneous EEG, recording at conventional PSG and EEG paper speeds. The purpose of this study was to determine the value of limited EEG montages viewed with EEG reformatting capability in the identification of seizures during PSG. DESIGN: Blinded EEG analysis of seizures and arousals during VPSG. SETTING: Tertiary care hospital with sleep laboratory and epilepsy monitoring unit. PATIENTS: Subjects with focal (partial) epilepsy that underwent video-EEG monitoring. INTERVENTIONS: We designed two 7-channel EEG montages that might facilitate the identification of seizures arising from the frontal and temporal lobes. Sleep medicine- and EEG-trained polysomnographers were asked to review tracings containing frontal or temporal lobe epileptic seizures and arousals from sleep. Utilizing the capability of our digital recording equipment to reformat EEG channels and change paper speeds, we asked the readers to classify events recorded with 4, 7, and 18 channels of simultaneous EEG, at paper speeds of 10 and 30 mm/sec. MEASUREMENTS AND RESULTS: 6 readers viewed 32 sleep-related events (13 frontal lobe seizures, 11 temporal lobe seizures, and 8 arousals). The following factors were analyzed for their influence on accuracy of event detection: 1) the type of training of the reader (EEG vs. sleep medicine); 2) the number of EEG channels (4, 7, or 18); and 3) paper speed (10 vs. 30 mm/sec). Pair-wise comparisons and generalized estimating equations were used to identify factors leading to more accurate detection of seizures and arousals. 77% of events were correctly identified: 74% of seizures and 88% of arousals. Seizure detection was better using 7 and 18 channels (sensitivity of 82% and 86%, respectively) than 4 EEG channels (sensitivity of 67%) for temporal lobe seizures only. The number of EEG channels did not affect the accuracy of frontal lobe seizure detection. For EEG-trained readers, accuracy was greater using 30 mm/sec than 10 mm/sec paper speed (85% vs. 78% correct, respectively). CONCLUSIONS: Adding EEG channels and EEG reformatting capabilities to PSG interpretation improves the detection of some types of epileptic seizures. Accuracy of temporal lobe seizure detection using an abbreviated 7-channel montage approximates that of an 18-channel EEG recording. However, the same is not true of frontal lobe seizures in which accuracy was similar regardless of the number of EEG channel available. Further studies are needed to identify specific EEG montages that would best detect epileptiform activity during VPSG.

Electrodes↗

[Validation of half-night polysomnography for sleep apnea/hypoapnea syndrome].

UNLABELLED: A diagnosis of sleep apnea/hypopnea syndrome (SAHS) is based on clinical signs and nighttime polysomnograms. Brief polysomnography has been proposed as an alternative to all-night recording. OBJECTIVES: The aim of this study was to determine whether a polysomnograms obtained during the first half of the night is sufficient for establishing a diagnosis of SAHS and to determine the correlation between polysomnographic variables recorded during the first four hours (half the study time) with those recorded over the full eight hours (full study time), as well as to determine diagnostic agreement. DESIGN: Thirty-five patients suspected of having SAHS were studied prospectively. Baseline polysomnograms were scored blindly by two independent observers following standard methods. A diagnosis of SAHS was made according to guidelines of the Spanish Society of Pneumology and Chest Surgery. During the first half of the night and up to the end of each recording period we gathered neurophysiological and respiratory variables and diagnostic impressions. RESULTS: The correlation between variables (sleep stage, overall AHI, REM-AHI, non-REM-AHI and sleep efficiency) recorded in the first half of the night and throughout the night was significant (p < 0.05) by both Pearson's correlation coefficient (r) and by the intraclass correlation coefficient (ICC). In 33 of 35 patients (94.3%) diagnostic agreement was achieved (95% CI 80.84-99.30); when SAHS was severe, agreement was 100%. CONCLUSION: Based on these results, we conclude that for patients with a diagnosis of severe SAHS during the first half of the night, data recorded during the second half can be considered supplementary.

Circadian Rhythm↗

[Polysomnography].

Polysomnography(PSG) is essential for the diagnosis of all pathophysiologic conditions due to both any types of sleep disordered breathing and to any types of sleep disturbance. Since this issue's objection is to describe the outline of PSG, we will explain here about when PSG is needed, what type of measurements are necessary for PSG, and how it should be interpreted from the result of the PSG tracing for the diagnosis for sleep apnea syndrome, etc.

Diagnosis, Differential↗

Workup and indications for polysomnography in patients with sleep-related complaints.

A significant proportion of the population has chronic sleep problems necessitating an increasing involvement by the primary care physician. Also, the general patient population is becoming more familiar with these disorders and is seeking assistance. Because sleep studies are expensive and time consuming, adhering to the recognized indications for testing reduces the number of inappropriate studies. Under most circumstances, individuals with excessive daytime sleepiness and symptoms suggestive of obstructive sleep apnea are candidates for polysomnography. Other individuals with parasomnias or difficult-to-treat insomnia are also candidates for testing. In some circumstances, procedures designed to assess sleepiness may also need to be used to ascertain the impact of the disorder on daytime functioning and may be part of evaluations involving the transportation industry. Only after taking a thorough history and doing a physical examination can the physician make an accurate determination of the appropriate study type.

Diagnosis, Differential↗

Arousal norms for children age 5-16 years based on home polysomnography.

Fragmentation of sleep by brief arousals has become an acknowledged aspect of poor quality sleep but there is a shortage of normative data on such arousals, especially for children. Norms for arousals (defined according to American Sleep Disorders Association criteria) were compiled for 61 children age 5-16 years using the Oxford Medilog system for a single night of home polysomnography. No significant differences were seen between the five age subgroups considered in average number of arousals per hour of sleep although individual differences were apparent at each age level and arousal duration was somewhat longer at younger ages. The low arousal rates in the children studied are in keeping with other evidence that arousal rates increase throughout life. Boys were no different from girls in either arousal frequency or duration. Arousal frequency was correlated with PSG awakenings but only to a modest extent. These new normative values should be useful in clinical practice and research for the assessment of the quality of children's sleep.

Adolescent↗