Diagnostic performance of segmental plethysmography and Doppler ultrasound in obliterating vascular diseases in the lower limbs.

The diagnostic value of three noninvasive techniques was evaluated in a group of 100 "normal" and 100 "abnormal" limbs. The choice of segmental plethysmography, systolic pressure determination, and Doppler velocity curve was based on the fact that these methods are noninvasive, inexpensive, and atraumatic; they can easily be performed by paramedical personnel. There was a statistically significant difference between the ankle-to-arm systolic blood pressure ratio of normals and abnormals as measured by Doppler ultrasound with 0.96 as the dividing line, no false positives and only 11% false negatives were found. However, there was a large overlap for many parameters calculated from the velocity curve. The general morphological aspect of the velocity curve shows a better diagnostic performance than the calculated parameters of this curve: a monophasis curve had an 85% chance of being normal. The ankle segmental plethysmogram yielded only 5% false negatives, but 20% false positives; moreover, a biphasic curve has a 90% chance of being normal. Thus large-scale screening in clinical practice or in epidemiologic studies can best be done by Doppler pressure measurements; the velocity curve performs less satisfactorily. Segmental plethysmography is more sensitive, but it yields more false positive results.

Blood Pressure↗

Standardization of venous distensibility measurements in plethysmography.

This paper comprises a summary of the literature on plethysmography, of study objectives, techniques, and interpretation of methods. The venous distension plethysmography is suitable for the evaluation of clinical venous pathology, but a standardization of the method is urgently needed. The test schedule is described, explained, and discussed. Some questions arising from the test schedule and some ideas that should be more closely discussed are offered.

Adult↗

Further observations of the digital plethysmography in response to auditory stimuli and its clinical applications.

Further observations of the digital plethysmography with auditory stimuli and its clinical applications were performed in patients with vibration disease and heart diseases. The responsive pattern to the auditory stimuli in the digital plethysmogram could be faithfully reproducible if it elapses more than 5 minutes apart between the first stimulus and the second one. The responsive patterns were divided into four types: normal (N), hyperreactive (I and D) types and hyporeactive (P) type. The values of urinary catecholamine increased in parallel to the activity level of the autonomic nerve. The hyperreactive type (D) had the highest value of urinary catecholamine, and vice versa. With regard to the age, the elderly was prone to show hyporeactive (P) type, and the young tended to be hyperreactive (D) type. Psychologic factors were examined by Cornell medical index. Neurosis was not necessarily related to the hyperreactive type. In clinical applications, it was observed by this method that the autonomic imbalance in patients with vibration disease, angina pectoris, or hypertension was recovered by the treatment, and the abnormal types of the response recovered to N type. In conclusion, the digital plethysmography with auditory stimuli as one of the autonomic nerve function tests would be much useful and non-invasive method for observation of clinical course and decision of the severity.

Adult↗

Pitfall of venous occlusion plethysmography.

The supposition that the lower limb expands uniformly in circumference during venous occlusion has been investigated. The 3 compartments of the calf were found to be expand to differing degrees depending on the volume of muscle within the compartment. The effect of this phenomenon on the measurement of venous outflow and capacitance using an overlapping strain gauge was assessed. When using an overlapping strain gauge, the anatomical site of overlap was found to alter the measured values of outflow and capacitance by as much as 50%. These errors do not arise with strain gauges designed to fit a small range of limb circumferences, so that no overlap occurs. The reproducibility of plethysmography may be enhanced by attention to the site and degree of overlap of gauges which are designed to fit all sizes of limb. Technicians performing venous occlusion plethysmography should be aware of these variations, so that the examination technique can be standardized.

Acute Disease↗

Instead of "plethysmography": "kenoseography" and "plesmonegraphy".

The recording of volume changes in health and disease has from old been designated as "Plethysmography". This was supposed to be a correct term for the recording (graphein) of an increase in volume (plethysmos). The present paper shows that the choice of this term was not felicitous, and suggests an alternative. The first "plethysmographic" recordings are ascribed to Glisson (1622) and Swammerdam (1737). Since Glisson and Swammerdam did, in fact, record the volume of muscle to be constant on contraction, their measurements should probably have been referred to as "isography". This, however, is merely a historical matter. Presently venous outflow measurement is a common procedure to establish the diagnosis of deep vein thrombosis. Venous outflow is determined by recording the decrease in volume of a limb which occurs after release of a congestion cuff. As this is quite the opposite of what is meant by "Plethysmography", another indication is needed for this examination. It appears that a suitable alternative can be taken from ancient Greek medical literature.

Plethysmography↗

Diagnostic accuracy of computerized impedance plethysmography in the diagnosis of symptomatic deep vein thrombosis: a controlled venographic study.

The aim of our study was to evaluate the sensitivity, the specificity, and the positive and negative predictive values of a recently developed computerized impedance plethysmography (CIP) in the diagnosis of deep vein thrombosis (DVT); 117 consecutive outpatients with a clinical suspicion of DVT were evaluated. After informed consent was obtained, a CIP and, within twenty-four hours, a venography of the symptomatic lower limb were performed in each patient. The results of CIP were compared with the results of contrast venography, which was considered as the gold standard. As far as the diagnosis of both proximal and distal DVT was concerned, the accuracy of CIP was 88.5%; the sensitivity and specificity were 95.1% and 83.6%, respectively; the positive and negative predictive values were 81.2% and 95.8%, respectively. When the diagnosis of only proximal deep vein thrombosis was considered, the accuracy of CIP was 88.8%; the sensitivity and specificity were 97.1% and 83.6%, respectively; the positive and negative predictive values were 79.0% and 97.8%, respectively. The authors conclude that the newly developed CIP has a diagnostic accuracy similar to that of traditional impedance plethysmography. Moreover, being completely automated and portable, CIP can play an important role in the bedside diagnosis of DVT.

Diagnosis, Computer-Assisted↗

Plethysmography for the assessment of pneumococcal pneumonia and passive immunotherapy in a mouse model.

The increasing prevalence of resistance to antibiotics of Streptococcus pneumoniae, the main causative agent of community-acquired bacterial pneumonia, necessitates the development of both new therapeutic strategies and noninvasive methods in order to evaluate their efficacy. The efficacy of passive immunotherapy with human intravenous immunoglobulin (IVIG) or solvent alone, administered intranasally or intravenously, was evaluated in a mouse model of acute pneumonia. Lung bacterial load was also evaluated, using a classical but invasive method, as was respiratory function (minute ventilation, respiratory frequency and tidal volume) using plethysmography, a simple noninvasive method commonly used in inhalation toxicology, but not previously used to assess respiratory infection. Forty-eight hours after infectious challenge, the lung bacterial load was significantly lower in IVIG-treated mice than in untreated mice. At the same time, minute ventilation was significantly lower than reference values for untreated mice (36+/-3 versus 57+/-8 mL.min(-1), p<0.01, and 31+/-2 versus 50+/-5 mL.min(-1), p<0.01 for intranasal and intravenous administration of solvent, respectively) but not in mice treated with IVIG by either route of administration. Plethysmography therefore appears to be a simple and reliable test for the follow-up of acute respiratory infection.

Acute Disease↗

Continuous limb blood flow estimation in the newborn using electrical impedance plethysmography.

This study aims to define a method for acquiring limb flood flow data from newborn babies on a continuous basis which would be suitable for automatic processing. Pulsatile electrical impedance and strain gauge signals were analyzed in 3 different ways. The results were compared with estimates of flow derived from venous occlusion plethysmography with a mercury-in-rubber strain gauge. Measurements were made from 33 babies. The impedance technique was easier to perform than the strain gauge technique. The reproducibility of the various estimates of flow is shown in Table 3. The beat-to-beat reproducibility of simultaneous pulsatile mesurements and of repeated measurements on different subjects was greater from the impedance recordings than from the strain gauge recordings. The results of linear regression analyses between the different flow estimates are shown in Table 4. The best correlation with flow measured using venous occlusion plethysmography was with flow calculated from the impedance pulse height, F(Zmax) (r = 0.76; n = 30; P < 0.001). The regression line between these 2 variables was not statistically significantly different from the line of identity, (P < 0.98), and the intercept is close to zero. The measurement of the impedance pulse height, delta Zmax, and the subsequent calculation of F(Zmax) could be automated and provide continuous beat-to-beat blood flow estimations.

Extremities↗

New methods to evaluate endothelial function: method for assessing endothelial function in humans using a strain-gauge plethysmography: nitric oxide-dependent and -independent vasodilation.

The vascular endothelium is involved in the release of various vasodilators, including nitric oxide (NO), prostaglandins, and endothelium-derived hyperpolarizing factor as well as vasoconstrictors. NO plays an important role in the regulation of vascular tone, the inhibition of platelet aggregation, and the suppression of smooth muscle cell proliferation. Several diseases are associated with changes in endothelial function mediated through reduced NO bioavailability. In addition, endothelial dysfunction is an early feature of atherosclerosis and vascular diseases in humans. Therefore, it is clinically important to estimate the degree of endothelial dysfunction. Several methods have been used to assess endothelial function in humans. Recently, we have evaluated the effects of intra-arterial infusion of infusion of NO agonists, such as acetylcholine, methacholine, and bradykinin, and NO antagonists on forearm blood flow using mercury-filled Silastic strain-gauge plethysmography. The response to the intra-arterial infusion of vasoactive agents should be considered the gold standard in assessing endothelial function, because the use of agonists to stimulate NO release allow us to draw more specific conclusions concerning the role of basal and stimulated NO release. However, the invasive method is time-consuming and is a burden for patients. A noninvasive method of measuring forearm blood flow response to reactive hyperemia also is useful in assessing endothelial function. In this review we would like to explain in detail the methods of assessing endothelial function in humans using strain-gauge plethysmography.

Endothelium, Vascular↗

Computerized strain-gauge plethysmography in the diagnosis of symptomatic and asymptomatic venous thrombosis.

This study compares the results of a computerized strain-gauge plethysmograph with ascending lower limb venography in 94 patients with clinical deep venous thrombosis, and in 121 patients with asymptomatic legs being screened after total hip replacement. In the symptomatic patients, strain-gauge plethysmography had a sensitivity of 100%, an accuracy of 73%, a specificity of 64% and a negative predictive value of 100% for thrombosis above the popliteal confluence. In the screened patients, the figures were 38.1%, 55.4%, 60.0% and 81.1% respectively. Computerized strain-gauge plethysmography is a safe, non-invasive, reliable and portable method of excluding proximal thrombosis in a symptomatic patient. It avoids the need for urgent venography when anticoagulation therapy is reserved for those with proximal thrombosis. The device was not valuable as a screening tool after total hip replacement, since it had a low specificity and did not reliably detect the non-occlusive mural femoral thrombi which typically follow this procedure.

Diagnosis, Computer-Assisted↗

Impedance plethysmography. A screening procedure to detect deep-vein thrombosis.

Impedance plethysmography has great potential in the non-invasive detection of dangerous iliofemoral thrombosis. It was used to examine 198 patients undergoing total hip replacement for evidence of proximal venous segment thrombosis. There were 13 abnormal results, and subsequent venography in 12 of these revealed a false-positive rate of 4.0%; there was one false-negative result giving a sensitivity of 85.7%. A venographic study of 46 other patients clinically suspected of having a proximal deep-vein thrombosis confirmed this sensitivity. The iliofemoral thrombosis rate was 3.9% after total hip replacement and this rate increased significantly in the group of patients over 70 kg in weight. Impedance plethysmography was found to be a useful non-invasive screening procedure for potentially fatal proximal venous thrombosis.

Adult↗

Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.

STUDY OBJECTIVE: To assess the accuracy of the respiratory inductive plethysmography in the measurement of PEEP-induced changes in end-expiratory lung volume during mechanical ventilation and its accuracy and stability in the measurement of ventilation during controlled mechanical ventilation and spontaneous breathing. DESIGN: An open comparison between two methods using a criterion standard. Either a pneumotachometer (mechanically ventilated patients) or a spirometer (spontaneously breathing subjects) was used as the reference method. SETTING: Tertiary care center; a multidisciplinary intensive care unit and a metabolic research unit. PATIENTS: Six mechanically ventilated, paralyzed postoperative open heart surgery patients, six spontaneously breathing COPD patients, and eight healthy volunteers. INTERVENTIONS: Stepwise increases and reductions of PEEP from zero to 12 cm H2O during controlled mechanical ventilation; repeated validation of the calibration of the respiratory inductive plethysmography (RIP) in both mechanically ventilated and spontaneously breathing subjects. MEASUREMENTS AND RESULTS: The baseline drift of the RIP in vitro was 10 ml/150 min and in a ventilated model it was 20 ml/150 min. In mechanically ventilated patients, the mean error of the calibration after 150 min was within +/- 5 percent. Change in end-expiratory lung volume (EELV) during the stepwise increase of PEEP up to 12 cm H2O was 849 +/- 136 ml with the RIP and 809 +/- 125 ml with the pneumotachometer (PT), and during the stepwise reduction of PEEP it was 845 +/- 124 ml and 922 +/- 122, respectively (not significant [NS]. The mean difference between methods in the measurement of change in EELV was -6.6 +/- 3.5 percent during increasing and 6.6 +/- 6.7 percent during decreasing PEEP (NS). Both in mechanically ventilated and spontaneously breathing subjects, the difference between methods was significant for VT and VT/TI. The difference in VT was -2.2 +/- 0.2 percent during mechanical ventilation, -1.1 +/- 0.5 percent in spontaneously breathing COPD patients, and 2.9 +/- 0.4 percent in healthy volunteers (NS between groups). CONCLUSIONS: The RIP is sufficiently accurate for the measurement of PEEP-induced changes in EELV during controlled mechanical ventilation. The accuracy of tidal volume measurement is similar during mechanical ventilation and spontaneous breathing. The calibration of the RIP is stable enough for bedside monitoring of changes in lung volumes.

Adult↗

Validation of respiratory inductive plethysmography in patients with pulmonary disease.

The assumption that the respiratory system behaves with 2 df of motion in healthy persons allows calibration of respiratory inductive plethysmography (RIP) with spirometry (SP). To ascertain whether RIP could be calibrated by the same assumption in patients with lung disease, even though at least 3 df of motion are visualized (ie, upper and lower rib cage and upper and lower abdomen move out of phase), RIP was calibrated by a two-position calibration procedure and validated satisfactorily by simultaneous SP in the erect, semirecumbent, supine, and lateral decubitus positions. In lung disease, the contribution to tidal volume of regions moving independently of the combined rib cage and abdominal movements either is small or remains relatively constant with change of body posture. For clinical monitoring of the resting breathing pattern where patient movements cannot be restricted, respiratory inductive plethysmography can serve as a reliable semiquantitative, noninvasive ventilatory monitoring device.

Abdomen↗

Determination of ventilatory volume in mice by whole body plethysmography.

We examined the reliability of whole-body plethysmography (WBP) for determining the ventilatory volume in mice. The degree of agreement of tidal volume (VT) determined consecutively by WBP with that by direct plethysmography (DP) or pneumotachography (PT) was analyzed using urethane-anesthetized young male 129/Sv mice. Between WBP and DP, the mean difference of VT was 0.000 ml with a 95% confidence interval of -0.003 to 0.002, whereas that between WBP and PT was 0.000 ml (-0.004 to 0.003). The limits of agreement, or mean +/- 2SD of the difference, were -0.008 and 0.008 ml in WBP vs. DP, and -0.011 and 0.010 ml in WBP vs. PT. These values were 5.1-6.6% of the average VT (0.157 ml in WBP and DP, and 0.165 ml in WBP and PT). Thus, VT can be determined by WBP without any bias and with a systemic error of less than 7% of that measured by the other direct methods examined. Through applying WBP to conscious 129/Sv and 129/SvJ-ICR hybrid mice, we further studied the effects of differences in mouse strain, age and sex on respiratory rate (f) and minute volume (V = VT.f), and their reflex changes in responses to systemic hypoxia and hypercapnia. V was significantly greater in young (10-16 weeks old) male 129/Sv than in young male 129/SvJ-ICR hybrids (139 +/- 11 and 73 +/- 8 ml/min/100 g, respectively), while the pattern of reflex responses was similar. In aged (32-44 weeks old) male 129/Sv, the basal level of V and its reflex increases were all diminished as compared to those in their young counter parts. However, we were unable to find significant differences between aged male and female 129/Sv mice. In conclusion, WBP is a useful and reliable method to determine ventilatory parameters in conscious and anesthetized mice. Furthermore, there are considerable strain- and age-related differences in baseline ventilation and reflex responses to hypoxia and hypercapnia.

Age Factors↗

Comparison between tail skin blood flow measurements by ultrasonic Doppler flowmetry and plethysmography during heating in anesthetized rats.

Tail skin blood flow (TBFu) was directly measured in anesthetized and passively heated rats by ultrasonic Doppler flowmetry during heating, and the values were compared to those (TBFp) simultaneously measured by venous-occlusion plethysmography. TBFp was estimated from the values per unit tissue multiplied by the tail volume, the shape of which was assumed to be a cone. TBFp was highly correlated with TBFu, with a regression equation of TBFp = 0.7TBFu+0.1 (r2 = 0. 94, p<0.001). Although TBFp was slightly lower than TBFu, the equation is useful to estimate the absolute values of tail skin blood flow from the values of plethysmography in awake rats.

Anesthesia↗

Determination of functional residual capacity with 133-xenon radiospirometry. Comparison with body plethysmography and helium spirometry. Effect of body position.

This study was undertaken to estimate the accuracy of 133-xenon radiospirometry for determination of FRC in healthy subjects. Forty healthy volunteers, both smokers and non-smokers, were examined. The FRC of each subject was concurrently determined with radiospirometric, He-dilution in closed circuit, and body plethysmographic methods. The radiospirometric and He-dilution measurements were done in supine and in sitting positions, the body plethysmography on sitting subjects, only. The mean FRC measured by radiospirometry (FRCRS) was 0.72 1 larger than that measured by helium spirometry (FRCHe) in sitting position (P < 0.01). In supine position the FRCRS was 0.65 1 larger than the FRCHe (P < 0.01). The body plethysmography gave FRC (TGV) 0.35 1 larger than the FRCHe sitting (P < 0.01). The FRCHe and the FRCRS in the sitting position were 0.48 and 0.55 1 larger than in the supine position (P < 0.01), respectively. Trapped air correlated significantly (P < 0.01) with the difference FRCRS-FRCHe, when sitting. The results indicate that the FRC determined radiospirometrically is significantly larger than the FRC determined with He-spirometry. The difference is systematic, suggesting that it is caused by 133-xenon dissolved in blood and accumulated in tissues of the thoracic cage and by dissimilar representation of trapped air in FRCRS and FRCHe. With eventual correction of the systematic error, the FRC obtained as a by-product of radiospirometry may be used, e.g. for clinical purposes.

Adult↗

The effect of triglycyl-lysine-vasopressin (terlipressin INN, Glypressin) on skin blood flow, measured with laser Doppler flowmetry, thermography and plethysmography. A dose-response study.

Triglycyl-lysine-vasopressin (TGLVP) has been shown to reduce blood loss in connection with early excision of experimentally induced burns in pigs. In order to determine an appropriate dosage of TGLVP in patients with burns, a dose-response study was undertaken. TGLVP was administered intravenously in various doses to healthy volunteers, and skin blood flow was measured with laser Doppler flowmetry, thermography and plethysmography. Blood pressure, heart rate and electrocardiac activity were monitored as well as serum and urine changes. The doses of 5, 10 and 20 micrograms TGLVP/kg b.wt. caused statistically significant reduction of skin blood flow; minimal values were 35, 26 and 25% of predrug values for the three doses, respectively. Thermography and plethysmography were less sensitive for detecting effects of TGLVP than laser Doppler flowmetry. Minor effects on blood pressure and heart rate were recorded after TGLVP, but no disturbances in electrocardiac activity. Urinalyses revealed an antidiuretic action of TGLVP. The study supports earlier findings and suggests a dose level of TGLVP for the use in excision of burns.

Adult↗

Immersion and venous occlusion plethysmography in patients with idiopathic orthostatic hypotension.

In 3 patients suffering from idiopathic orthostatic hypotension (Shy-Drager's syndrome) venous distensibility was measured by occlusion plethysmography in supine and upright position. In this latter position, venoconstriction was absent, contrasting with the marked venoconstriction observed in normal volunteers studied under identical conditions. Venous occlusion plethysmography therefore seems to be useful to detect the autonomic defect leading to venous pooling. These patients were also immersed in water to the mid-abdomen while standing. This maneuver fully abolished orthostatic hypotension. Immersion is useful in motivating these patients to accept treatment by counterpressure garments, and makes early active physiotherapy possible.

Aged↗