Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PIPET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

The viscosity of neutrophils and their transit times through small pores.

Passive neutrophils from five different individuals are rapidly aspirated at constant suction pressure and at room temperature into a pipet with a diameter of 4 microns. The excess suction pressures (i.e., the pressures in excess of the small threshold pressure required to produce continuous flow into the pipet) are 5000, 10,000 and 20,000 dyn/cm2 (0.5, 1 and 2 kPa) and are comparable to those encountered in the microcirculation. The rate of entry into the pipet is modeled with a linearized version of a theory by Yeung and Evans for the newtonian flow of a neutrophil into a pipet or pore. From this theory and measurements of the cell size and its rate of entry into the pipet, we can calculate a value for the cytoplasmic viscosity. A linear (newtonian) fit of the theory to the experimental data gives a value for the viscosity of 1050 poise. A non-linear fit predicts a decrease in the "apparent viscosity" from about 1500 poise at zero excess pressure to 1000 poise at an excess aspiration pressure of 20,000 dyn/cm2. Our experiments and analysis also allow us to calculate a value for the transit time through short pores over a wide range of excess aspiration pressures and pore diameters. For example, for a pore diameter of 3 microns and an aspiration pressure of 1250 dyn/cm2, we predict a transit time of about 70 s. At 6 microns and 20,000 dyn/cm2, the predicted transit time is only about 0.04 s.

Blood Flow Velocity↗

Uncertainty analysis of (99m)Tc-HEPIDA liver clearance determination.

BACKGROUND: The aim of the study was to obtain information on the accuracy and precision of (99m)Tc-HEPIDA hepatic (Cl(Hp)) and plasma (Cl(Pl)) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. MATERIAL AND METHODS: In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hepatic clearances, as obtained from 185 patients, provided authentic information about (99m)Tc-HEPIDA behaviour in the body over a wide range of the clearances studied. The time course (99m)Tc-HEPIDA concentration in blood plasma has been described by means of biexponential function with parameter values derived for each patient. For each patient, using these data and urinary excretion data, there had been 5000 simulations performed; in each of the latter, the directly measured numbers have been substituted by simulated ones, obtained by means of varying the real ones, using random generated values. These reflected errors of plasma and radioactive standard pipetting (from 1 to 5%) and stochasticity of counting radioactive decay (1%). The time of blood sampling and urine voiding was also varied, assuming realistic uncertainty. The varied values were then used for computation of the simulated clearances. From the 5,000 calculated clearances for each patient, mean-values were calculated, as well as mean standard errors, standard deviations and mean uncertainty of measurements using a widely accepted rule of partial error propagation, and, in addition, a modified rule of the latter. Accuracy of clearance (Cl(Pl), Cl(Hp), Cl(Ur)) determination was assessed on the basis of comparison of mean values from simulations with those from directly recorded values. Precision was identified with standard deviation of each of the 5000 simulations. The uncertainty thus obtained was compared with results of calculated traditional and modified uncertainty. There was good agreement between standard deviation of the simulations with results of the modified calculation of total differential. Therefore, a coefficient of variation from simulation computations and a modified means of calculation of the propagated errors was accepted as a measure of uncertainty of a single determination. RESULTS/CONCLUSIONS: There was a very high correlation between the mean values from simulations and those from direct determinations (r > 0.98 in each case). The regression lines practically corresponded to the lines of identity. These correlations were not affected by the assumed range of pipetting uncertainty. In conclusion, the methods of (99m)Tc-HEPIDA clearance determination are satisfactory. Precision of clearance measurements depends substantially upon uncertainty of pipetting. For plasma clearance, the coefficients of variations at Cl(Pl) > 350 ml/min and at ab.80 ml/min amounted to 2 and 11% respectively, at pipetting uncertainty of 2%. Similarly, for hepatic clearances of (99m)Tc-HEPIDA of 300 ml/min and 30 ml/min, CV was 2.5 and 25%, respectively (at the same uncertainty of pipetting).

Algorithms↗

[Quality control of radioimmunoassay--evaluation of individual components of error and their contribution rates to total error].

Using Insulin RIA Kit (double antibody method, Dainabot Co., Ltd.), individual components of error due to pipetting of reagents, bound-free separation and counting were evaluated experimentally and theoretically. They were statistically synthesized to get the total response error relationship (RER). The resulting RER agreed well with the pooled RER obtained by the method reported previously. This good agreement indicates that individual components of error were reasonably and precisely estimated. Based on this result, contribution rates of individual components of error to the total response error were evaluated. The averaged contribution rates over the range to measure, when pipetting precision, C.V. (coefficient of variation) = 0.005, were 64% for counting error, 24% for bound-free separation error, and the error related with reagent delivery was only 12%. When C.V. = 0.01, however, which is considered normal pipetting precision, the contribution rate for the latter went up to 35%. Effect of poor precision in pipetting on final assay results is so great that much more attention than we usually think of should be paid to pipettes and pipetting techniques.

Quality Control↗

The phase of sperm flagellar beating is not conserved over a brief imposed interruption.

We have studied the phase component of flagellar beating by holding the head of a sea urchin sperm in the tip of a sinusoidally vibrating micropipet and then abruptly displacing the pipet laterally at a speed of 2.5 microns/ms for various durations. This rapid displacement of the pipet delayed the initiation of the next bend for as long as the displacement continued, up to a duration of 1 beat cycle, corresponding to a delay of 0.5 beat cycle. At the end of this displacement, the movement of the pipet was stopped completely without resumption of the initial vibration. Analysis of the flagellar waveform showed that immediately when the pipet was stopped, the flagellum started to beat by spontaneously initiating the bend that had been delayed. The flagellum then continued steady-state beating, with normal waveform and a new phase that was independent of the original phase of beating. These data suggest that the information on the phase of beating is located only at the basal end of the flagellum, and not in oscillators distributed along the axoneme. After this information has been lost, the flagellum can resume beating at any arbitrary phase relative to its original phase.

Animals↗

Effects of solid-liquid interface on the interfacial tension measured by micropipet technique.

Measurement of interfacial tension (IFT) using the micropipet technique involves the solid-liquid interface. At equilibrium, oil-water interfacial tension is determined from the interface curvature and the critical pressure, according to the Young-Laplace equation. This paper aims to examine the possible contribution of the solid-liquid interface on IFT measurement. Three different experimental configurations are used to examine the sought effect. The three configurations are straight, concentric, and tapered pipets with diameters ranging from 2.5 to 30 microm. For all three configurations, the critical pressure is found to depend only on the pipet diameter. However, when the Young-Laplace equation is applied to determine the IFT, a significant error was noticed at small pipet diameters. The IFT error was described by an exponential function whose asymptote approached the independently determined IFT value with a sufficiently large pipet diameter. The IFT error is anticipated to arise from the layerlike effect of an "ultrastructured" liquid near the solid surface. The solid-induced error in oil-water IFT is noted to fade away at lowered IFT by the addition of surfactant.

Journal Article↗

Interaction forces between red cells agglutinated by antibody. III. Micromanipulation.

In the flow studies described in two previous papers (Tha, S. P., and H. L. Goldsmith, 1986, Biophys. J. 50:1109-1116; Tha, S. P., J. Shuster, and H. L. Goldsmith, 1986, Biophys. J. 50:1117-1126), hydrodynamic forces of the order of 10(-11) N (mu dyn) were applied to measure the force of separation of doublets of hardened, sphered human red blood cells cross-linked by anti-B antibody. The same cell preparation and hyperimmune antiserum has here been used to carry out experiments with micropipet aspiration techniques. One cell of a doublet was aspirated onto a holding pipet, and a second aspiration pipet was brought into proximity of the other cell so that the two pipets and the doublet were colinear. Suction was then raised until the two cells separated. Some doublets were assembled by aspiration of a singlet, bringing a second singlet into apposition with the first, and releasing it from the pipet which was then withdrawn. Cells could be repeatedly assembled and separated. At 3.56% vol/vol antiserum, the mean normal force of separation was 0.45 +/- 0.11 nN in phosphate-buffered saline suspensions containing 2.5 x 10(4) cells/microliter; at 1.22% vol/vol antiserum, the value was 0.22 +/- 0.11 nN. The above values of the force were approximately 2.5 x greater than those from the flow studies. The data could be fitted to a Poisson distribution with 0.05 nN as the force needed to break a single cross-bridge (c.f. 0.024 nN from the previous hydrodynamic data). The forces of separation of randomly assembled doublets were lower than those of preexisting doublets. Repeated assembly and separation of doublets showed that the cell surfaces are nonuniform in adhesion strength both over the local scale less than 0.25 micron2 and the cell population.

Antibodies↗

Bacteria in semen used for IVF affect embryo viability but can be removed by stripping cumulus cells by vortexing.

Bacterial contamination of in vitro vs in vivo produced embryos presents a particular danger because of the alteration of the zona pellucida and the use of various biological products during culture. Our objective was to investigate the effects of semen contaminated with bacteria on IVF of bovine oocytes and to determine if removal of cumulus cells by vortexing as opposed to pipetting would reduce contamination and improve subsequent embryonic development. Semen from 5 bulls of the Native Korean breed (Bulls A, B, C, D, E) was used for IVF of matured oocytes. Preliminary studies had shown that the semen from Bulls A, B, D and E but not Bull C was contaminated with various species of common bacteria. After IVF, the cumulus cells surrounding the oocytes were removed either by pipetting or vortexing. Viability and cleavage rates of the resulting zygotes was assessed after 44 h in culture. When cumulus cells were removed by pipetting, only zygotes derived from oocytes that were fertilized with uncontaminated semen from Bull C developed to morula and blastocyst stages; zygotes derived from oocytes that were fertilized with contaminated semen from Bulls A, B, D and E started to degenerate, and the culture media became noticeably turbid. When cumulus cells were removed by vortexing, zygotes derived from oocytes fertilized with either contaminated or uncontaminated semen showed good rates of development (16 to 32%) to morula or blastocyst stages. From these results it can be concluded that the bacteria introduced with the semen contaminated the in vitro system and severely reduced the viability of the embryos. In contrast, complete removal of the cumulus cells with vortexing, as opposed to pipetting, reduced the contamination of the culture medium, allowing embryonic development to take place.

Animals↗

High-throughput extraction, amplification, and detection (HEAD) of HCV-RNA in individual blood donations.

BACKGROUND: High-throughput nucleic acid amplification techniques (NATs) are required for the detection of viral genomes in individual blood donations and might be helpful in any virological laboratory. OBJECTIVE: To develop and automate a method for the detection of hepatitis C virus RNA in individual blood donations, compatible with the time schedule of routine blood bank screening an product release. STUDY DESIGN: The viral RNA was isolated with the use of target specific capture oligonucleotides and magnetic beads. This extraction method was combined with reverse transcription/amplification (RT/PCR) and fluorescence detection. We adapted our method on a pipetting robot and pipetted all steps in a single room. When the pipetting was completed, microtiter plates were heat-sealed with foils and placed into a thermocycler. Positive reactions were detected with a fluorescent dye in a second room. Aerosols were avoided with programmed slow pipetting steps and with a special device constructed for the removal of the used disposable tips. During a 7 month period, we used this method in routine testing of individual donations prior to the release of all blood components. RESULTS: The total number of 11,700 individual donations including platelet concentrates were analysed. We tested up to 192 specimens in one run within 7 h. The frequency of cross-contamination using the automated procedure was 0.1%. Five specimens have been found repeatedly reactive for HCV-RNA, four of these were anti-HCV positive, one sample from a repeat donor was negative in anti-HCV assays. A seroconversion was detectable at his next presentation, 6 months later. CONCLUSION: In this pilot study, we demonstrate that automated HCV-RT-PCR testing is practicable for individual donations in high-throughput. Additionally, the described PCR approach could easily be adapted to the detection of other viral genomes by the use of specific primers.

Automation↗

Nanoengineered structures for holding and manipulating liposomes and cells.

We describe the fabrication of nanoengineered holding pipets with concave seating surfaces and fine pressure control. These pipets were shown to exhibit exceptional stability in capturing, transporting, and releasing single cells and liposomes 1-12 microm in diameter, which opens previously inaccessible avenues of research. Three specific examples demonstrated the utility and versatility of this manipulation system. In the first, carboxyrhodamine was selectively incorporated into individual cells by electroporation, after which nearly all the medium (hundreds of microliters) surrounding the docked and tagged cells was rapidly exchanged (in seconds) and the cells were subsequently probed by laser-induced fluorescence (LIF). In the second study, a single liposome containing carboxyrhodamine was transported to a dye-free solution using a transfer pipet, docked to a holding pipet, and held firmly during physical agitation and interrogation by LIF. In the third study, pairs of liposomes were positioned between two microelectrodes, held in contact, and selectively electrofused and the resulting liposomes undocked intact.

Cells↗

A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.

Automation↗

Ultralow-volume fraction collection from NanoLC columns for mass spectrometric analysis of protein phosphorylation and glycosylation.

An ultralow volume fraction collection system referred to as nano fraction analysis chip technology (nanoFACT) is reported. The system collects 25-2500-nL fractions from 75-microm nanoLC columns into pipet tips at a user-defined, timed interval, typically one fraction every 15-120 s. Following collection, the fractions in the tip dry down naturally on their own in such a way as to create a concentrated band at the very end of the interior of the pipet tip. The fractions are then reconstituted directly in the pipet tips in approximately 250 nL of solvent prior to analysis. Because the chromatography and reconstitution solvent are independent, the reconstitution solvent can be selected to maximize ionization efficiency without compromising chromatography. In the infusion analysis of the nanoLC fractions, a low-flow electrospray chip is used which consists of 400 nozzles, each with an inner diameter of 2.5 microm and yielding flow rates of approximately 20 nL/min. Therefore, when reconstituted in 250 nL, each nanoLC fraction can be analyzed for over 10 min. This increase in analysis time allows for signal averaging, resulting in higher data quality, collision energy optimization, slower scanning techniques to be used, such as neutral loss and precursor ion scanning, higher resolution scans on FTMS instruments, and improved peptide quantitation. Furthermore, the nanoLC fractions could be archived in the pipet tips for analysis at a later date. Here, the advantages of nanoFACT are shown for phosphorylation analysis using bovine fetuin and glycosylation analysis using bovine ribonuclease B (RNase B). In the phosphorylation analysis, a comparison between conventional nanoLC and a nanoFACT analysis was performed. An MS/MS spectrum of a triply phosphorylated peptide, 313-HTFSGVApSVEpSpSSGEAFHVGK-333 could only be obtained using nanoFACT, not with nanoLC. Furthermore, spectral quality for the nanoFACT analysis was significantly improved over nanoLC. This was determined by comparing the number of diagnostic ions between the nanoFACT and nanoLC spectra, and it was found that the nanoFACT spectra contained a 19% or greater number of diagnostic ions for nonphosphorylated peptides and 55% or greater for phosphorylated peptides. For the glycosylation analysis, the glycosylation site of RNase B was fully characterized using 100 fmol of tryptic digest on a three-dimensional ion trap mass spectrometer.

Amino Acid Sequence↗

Accuracy and precision of a robotic sample processor.

The accuracy and precision of the Packard Probe 1000, a computer-driven robotic sample processor, were determined using NCCLS Guideline 18-P, employing a rigorous gravimetric procedure. For volumes of 25, 100, and 200 muL, inaccuracy ranged from -0.5 to +0.6% (saline) and -0.8 to +0.7% (human serum), and imprecision from 0.1 to 0.6% (saline) and 0.02 to 0.8% (human serum), in the dip and sip mode of pipetting. For the same volumes of saline in the dispense-through pipetting mode, inaccuracy ranged from -0.1 to -0.9% and imprecision from 0.1 to 0.5%. To obtain this level of performance, the instrument's operating parameters were changed from the factory default settings. This automated liquid-handling system is capable of impressive accuracy and precision, but it must be calibrated in the same manner as any other volumetric device. Performance varies with the volume, type of liquid, and mode of pipetting. Inaccuracy of less than or equal to 1.0% and imprecision of less than =1.0% can be attained along with rapid, walkaway pipetting of calibrators, controls, and large numbers of patient samples.

Chemistry, Clinical↗

Determination of fat in raw and processed milks by the Gerber method: collaborative study.

The Gerber method is used worldwide as a simple and rapid method for determining fat in raw and processed milks. However, the volume of the test portion used in the method has not been internationally agreed upon. A collaborative study was conducted to evaluate performance of the Gerber method using either a weighed test portion (11.13 g) or by a 10.77 mL test portion delivered by pipet. For each method, laboratories received 10 test samples: 5 raw and 5 pasteurized homogenized milks, 2 of which were blind duplicate pairs. Eleven and 10 laboratories participated in the evaluation of aliquot addition by weight and pipet, respectively. Mojonnier ether extraction (Method 989.05) was used as the reference method. Interlaboratory study statistics were similar between methods of test portion addition and between raw and processed materials; therefore, summary interlaboratory study statistics were pooled. The fat content of milk samples ranged from 0.96 to 5.48%. Absolute reproducibility and repeatability were not affected by fat level, and pooled statistical performance (invalid and outlier data removed) was (g fat/100 g milk) s(r) = 0.026, s(R) = 0.047, r = 0.074, and R = 0.132. Relative standard deviations increased with decreasing fat content, and were summarized by fat level: 1-2% fat milk, mean = 1.437, RSD(r) = 1.809%, RSD(R) = 3.271%; 2-6% fat milk, mean = 4.156, RSD(r) = 0.626%, RSD(R) = 1.131%. Compared with ether extraction, test results by the Gerber method were slightly lower (0.02% fat) using a weighed test portion and significantly lower (0.06% fat) using a 10.77 mL volume addition by pipet. A trend toward underestimating fat content at lower fat concentrations (1-2% fat) was observed with the weighed test portion but not when a pipet was used. The Associate Referee recommends that the Gerber method using a weighed test portion be adopted as First Action with applicability limited to whole milk.

Animals↗

Determination of fat in raw milk: comparison of mojonnier (ether extraction) and Gerber method.

Results are compared for the approved Gerber method that specifies a TC 11.07 mL pipet and 2 modifications that specify a TC 10.77 mL pipet or a weighed 11.125 g sample of milk rather than a pipetted sample. All results were also compared with results obtained with the Mojonnier method for determining the fat content of raw milk. The standard deviation is somewhat lower for the Mojonnier method than for any of the Gerber methods; among the Gerber methods, the standard deviations were lower for the TC 10.77 mL and 11.125 g modifications. It is recommended that one of these modifications replace the current specified TC 11.07 mL pipet method.

Animals↗

Induction of optical density waves and chemotactic cell movement in Dictyostelium discoideum by microinjection of cAMP pulses.

The development of most multicellular organisms involves coordinated cell movement. The early aggregation of Dictyostelium cells has been shown to be mediated by chemotactic movement to propagating waves of cAMP. We have proposed that propagating waves of a chemoattractant, most likely cAMP, also control the movement of cells in mounds and slugs. We have now used periodic pressure injection of pulses of cAMP in the extracellular space of aggregation streams, mounds, and slugs to investigate whether these signals can be relayed and control cell movement, using quantitative digital time-lapse microscopy. Our major findings are (1) short (0.1 s) pulses of cAMP (10(7) molecules) were able to elicit optical density (OD) waves in fields of aggregating amoebae. They propagate from the micropipet outward and interact with endogenous OD waves. (2) Periodic injection of cAMP pulses into aggregation streams blocked the pulses coming from the center and led to the rapid accumulation of cells downstream of the pipet around the pipet. (3) Injection of pulses of cAMP into mounds elicited OD waves, which propagated from the pipet outward and interacted with the endogenous waves, indicating that the same propagator carries them. (4) Periodic microinjection of cAMP in the prespore zone of slugs led to accumulation of anterior-like cells around the micropipet followed by tip formation. Furthermore, the cAMP signal could control the spacing of the endogenous sorting pattern. These results strongly support the hypothesis that the optical density waves observed during early development up to the mound stage represent propagating cAMP waves. They suggest furthermore that cAMP is the morphogen that controls cell movements in slugs.

Animals↗

Changes in the mechanical properties of fibroblasts during spreading: a micromanipulation study.

Cell morphology is controlled in part by physical forces. If the main mechanical properties of cells have been identified and quantitated, the question remains of how the cell structure specifically contributes to these properties. In this context, we addressed the issue of whether cell rheology was altered during cell spreading, taken as a fundamental morphological change. On the experimental side, we used a novel dual micromanipulation system. Individual chick fibroblasts were allowed to spread for varying amounts of time on glass microplates, then their free extremity was aspirated into a micropipet at given pressure levels. Control experiments were also done on suspended cells. On the theoretical side, the cell was modeled as a fluid drop of viscosity mu, bounded by a contractile cortex whose tension above a resting value was taken to be linearly dependent on surface area expansion. The pipet negative pressure was first adjusted to an equilibrium value, corresponding to formation of a static hemispherical cap into the pipet. This allowed computation, through Laplace's law, of the resting tension (tau 0), on the order of 3 x 10(-4) N/m. No difference in tau 0 was found between the different groups of cells studied (suspended, adherent for 5 min, spread for 0.5 h, and spread for 3 h). However, tau 0 was significantly decreased upon treatment of fibroblasts with inhibitors of actin polymerization or myosin function. Then, the pressure was set at 30 mmH2O above the equilibrium pressure. All cells showed a biphasic behavior: (1) a rapid initial entrance corresponding to an increase in surface area, which was used to extract an area expansion elastic modulus (K), in the range of 10(-2) N/m; this coefficient was found to increase up to 40% with cell spreading; (2) a more progressive penetration into the pipet, linear with time; this phase, attributed to viscous behavior of the cytoplasm, was used to compute the apparent viscosity (mu, in the range of 2-5 x 10(4) Pa s) which was found to increase by as much as twofold with cell spreading. In some experiments the basal force at the cell-microplate interface was quantitated with flexible microplates and found to be around 1 nN, in agreement with values calculated from the model. Taken together, our results indicate a stiffening of fibroblasts upon spreading, possibly correlated with structural organization of the cytoskeleton during this process. This study may help understand better the morphology of fibroblasts and their mechanical role in connective tissue integrity.

Actins↗

Hand and shoulder ailments among laboratory technicians using modern plunger-operated pipettes.

Laboratory technicians working with plunger-operated pipettes have a monotonous work task loading the arm. A study was performed to evaluate the prevalence of hand and shoulder ailments among laboratory technicians in relation to the 'dose' of pipetting and relation to some psychosocial factors was used to compare a cohort of 128 females employed by university research laboratories with reference data obtained from 25 378 female Swedish state employees in general. The prevalence of hand ailments among the laboratory assistants was found to be twice that among female state employees in general. In the cohort a nested case-control study indicated that an increased risk of hand (OR = 5, 0) and shoulder (OR = 2, 4) ailments was associated with more than 300 h/year pipetting. Suggestions for permissible exposure levels for pipetting are presented.

Journal Article↗

Membrane capacity measurements suggest a calcium-dependent insertion of synexin into phosphatidylserine bilayers.

The mechanism by which synexin mediates calcium-dependent aggregation of medullary cell chromaffin granules and fusion of granule ghosts involves specific interactions with the lipid component of the membrane. To study the details of these interactions we measured synexin-induced changes in capacitance of phosphatidylserine bilayers formed at the tip of a patch pipet using the double-dip method. Provided calcium was present in the solution filling the pipet (10-50 mM) stable phosphatidylserine bilayers were easily formed. Addition of synexin (0.1 microgram/ml) to an external medium lacking added calcium induced no measurable changes in either bilayer resistance (10-30 G omega) or displacement current across the membrane. However, addition of calcium (0.1-2.5 mM) in the presence of synexin in the external solution caused a marked increase in the size and time constant of decay of the displacement current. From the steady-state value of the current we calculated a 5-fold decrease in resistance and from the charge displaced during the voltage-clamp pulses we calculated a 10-fold increase in membrane capacitance (from 20 to 200 fF). The size of the synexin-specific charge displacement in one direction during a pulse was always equal to the charge returning to the original configuration after the pulse. The synexin-specific transfer of charge reached saturation when the pipet potential was taken to a sufficient positive or negative value. These properties of the extra charge movement support our view that in the presence of calcium the cytosolic protein synexin penetrates into the bilayer. It is possible that these properties may be related to the mechanism by which synexin promotes membrane fusion in natural membranes.

Annexin A7↗