Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “LAMPS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Pilot neonatal screening program for lysosomal storage disorders, using lamp-1.

We have demonstrated that the lysosome associated membrane protein (LAMP-1) is elevated in plasma from approximately 70% of lysosomal storage disorder patients. As part of the development of a newborn screening program for lysosomal storage disorders we have developed a first tier screening assay based upon the level of LAMP-I in blood spots taken from newborn Guthrie cards. To determine the effectiveness of the first-tier marker a prospective pilot Guthrie neonatal screening program for the identification of LSD was commenced in April 1998. Prior to commencement of the pilot program ethical approval was obtained and information leaflets regarding the neonatal screening of LSD were distributed to parents at the time of their infant's Guthrie collection. The LAMP-1 assay utilizes a chicken polyclonal and a mouse monoclonal in a sandwich time resolved fluorescent immunoassay. LAMP-1 blood-spot calibrators and quality control specimens were developed and shown to be stable and reproducible. To date 11,183 infants have been screened using LAMP-1. The population distribution is described with a median and 98th percentile of 220pg/l whole blood and 483microg/l whole blood respectively. Acceptable CV% for intra and inter assay of 8.9% and 10% respectively were obtained.

Antigens, CD↗

Depth of cure efficacy of high-power curing devices vs traditional halogen lamps.

PURPOSE: To determine the depth of cure resulting from three different curing devices in a photoactivated microhybrid composite through high-performance liquid chromatography (HPLC) analysis of leachable monomers. MATERIALS AND METHODS: Three different curing units, a halogen lamp (Heliolux, Vivadent), a xenon lamp (Kreative Kuring, Allyn Welch), and a plasma-arc lamp (Apollo 95, DMDS) were investigated using a universal microhybrid composite (P 60, 3M) as the test material. To assess the effect of curing device variation, a flexural strength test was performed. In addition, samples of composite were prepared and cured "in contact" (0 mm between the sample surface and light-guide tip) and through a specific thickness of composite (1, 2, or 3 mm). The monomers (bis-GMA and UDMA) eluted from the samples were detected by HPLC. RESULTS: No significant differences were found in the mechanical properties of composite cured with different light sources. In contrast, the concentration of eluted monomers (bis-GMA, UDMA) at a depth of 2 mm and more was significantly higher for the specimens cured with the high-power curing devices than those cured with the traditional halogen lamp. CONCLUSION: Under these experimental conditions, high-power curing devices were shown to be inferior in the deep polymerization of resin composite when compared to a traditional halogen lamp.

Analysis of Variance↗

Re-use of wastewater: preventing the recovery of pathogens by using medium-pressure UV lamp technology.

Ultraviolet (UV) light has become widely accepted as an alternative to chlorination or ozonation for wastewater disinfection. There are now over 2,000 wastewater treatment plants worldwide using either low- or medium-pressure UV technology. Recent studies investigating UV lamp technology, configuration, cleaning requirements and ageing, as well as long-term performance tests, have demonstrated beyond any doubt the effectiveness of UV in inactivating pathogens in wastewater. Research has also shown that, to ensure permanent inactivation and prevent the recovery of microorganisms following exposure to UV, a broad, "polychromatic" spectrum of UV wavelengths is necessary. These wavelengths inflict irreparable damage not only on cellular DNA, but on other molecules, such as enzymes, as well. Only medium-pressure UV lamps produce the necessary broad range of wavelengths; low-pressure lamps emit a single wavelength peak which only affects DNA. Polychromatic medium-pressure UV light is so effective because of the lamp's exceptionally high UV energy output at specific wavelengths across the UV spectrum. It has been shown, for example, that pathogenic E. coli O175:H7 was able to repair the damage caused by low-pressure UV, but no repair was detected following exposure to UV from medium-pressure lamps.

Animals↗

The cDNA sequence of mouse LAMP-2. Evidence for two classes of lysosomal membrane glycoproteins.

We describe the isolation and sequencing of a cDNA encoding the mouse lysosomal membrane glycoprotein mLAMP-2 and the sequence differences that distinguish this molecule from the LAMP-1 class of proteins. An oligonucleotide probe corresponding to the NH2-terminal amino acid sequence of purified mLAMP-2 was synthesized by the polymerase chain reaction and used to screen several cDNA libraries. cDNA clones with an insert of 1,700 nucleotides were identified and sequenced. The deduced amino acid sequence of mLAMP-2 comprises a signal sequence of 25 residues and a 390-amino acid polypeptide (Mr 43,017) with the following putative domains: a large intraluminal region (residues 1-354) with 17 N-linked glycosylation sites (Asn-X-Ser/Thr), a hydrophobic transmembrane-spanning region of 24 residues (355-378), and a COOH-terminal cytoplasmic tail of 12 residues (379-390). When this sequence is compared with those of other lysosomal membrane glycoproteins, it is apparent that mouse LAMP-2 and human LAMP-2 form one homology class (LAMP-2) that is separated from the LAMP-1 class of proteins. The sequence differences in these two classes provide a basis for comparing the structure of the proteins with their biochemical and biological properties.

Amino Acid Sequence↗

[Pathogenic antibodies in systemic lupus erythematosus: anti-LAMP antibodies].

We recently demonstrated that a monoclonal anti-DNA antibody, spontaneously produced in lupus B/W mice, recognizes the same protein(s) at the surface of several human cell types involved in lupus pathogenesis including normal human erythrocytes, normal platelets and rat neuronal tissue. This cell-surface protein(s) cross-react(s) with double-stranded DNA. We suggest to call this protein(s) LAMP [lupus associated membrane protein(s)]. Here we show that: immunoglobulins eluted from kidneys of autoimmune MRL/lpr/lpr mice strongly react with LAMP. Anti-LAMP antibodies are present in large amount in MRL/lpr and B/W mice sera. Anti-LAMP are present in 25 out of 25 human SLE sera ranged as SLE on the basis of revised American Rheumatism Associated classification. Interestingly, two of these sera did not display anti DNA anti-body activity. Taken together, these results strongly suggest a role of LAMP in the pathogeny of SLE.

Animals↗

[Experience with a new slit lamp concept (author's transl)].

Since the development of the first slit lamp by A. Gullstrand in 1911 this instrument is an indispensible part of our diagnostic repertoire. Nevertheless it was not until almost 40 years later that the slit lamp could be able to be used for the examination of the fundus as a result of the development of the Goldmann 3-mirror contact glass. Because of the increasing importance of antiretinal detachment prophylaxis the slit lamp examination also of the rear end of the eye its becoming more and more important because of its good stereoscopy, the excellent illumination and the high magnification. A newly developed slit-lamp apparatus fulfils these special requisites which have firstly been demanded recently. This apparatus is easy and comfortable to use, which makes easier above all the contact glass examination. Technical factors, possibilities of application and experience with this slit-lamp are discussed.

Ophthalmoscopes↗

Photokeratitis and UV-radiation burns associated with damaged metal halide lamps.

BACKGROUND: Damaged metal halide lamps are known to cause outbreaks of photokeratitis and UV-radiation burns among children and adults, which has prompted the Food and Drug Administration, Rockville, Md, to publish consumer recommendations to prevent such injuries. We investigated 3 outbreaks of photokeratitis and UV-radiation burns in gymnasiums associated with failure to heed these recommendations. OBJECTIVE: To determine the cause of the outbreaks and promote interventions to prevent further injuries. DESIGN AND SETTING: A cohort study of persons exposed to damaged metal halide lamps during the index outbreak in a community gymnasium and a descriptive epidemiologic study of 2 subsequently identified outbreaks in other gymnasiums. PARTICIPANTS: A total of 273 persons potentially exposed during events in 3 gymnasiums. MAIN OUTCOME MEASURE: Photokeratitis with onset within 12 hours of the event. The intensity of UV radiation was measured, and an occupational exposure standard applied. RESULTS: Investigation of the index outbreak identified 18 (approximately 3%) persons who met our case definition for photokeratitis. The median incubation period was 7 hours, and health care visits were reported by 11 persons (61%). Of the 18 patients, 17 (94%) were seated in the back of the gymnasium. Among 37 persons sitting in this high-risk area, the attack rate was 46%. Only 1 (9%) of 11 persons wearing glasses or contact lenses with UV-radiation protection in the high-risk area developed photokeratitis (relative risk, 0.15; P =.01). The safe occupational exposure limit in the high-risk area was 10 to 15 minutes, but exposures of 1 to 3 hours were reported. Prevention recommendations had not been instituted at any of the 3 facilities. CONCLUSIONS: Injuries from metal halide lamps are avoidable, but prevention recommendations may not be widely observed. All facilities using metal halide lamps in areas where children may be exposed should follow the Food and Drug Administration recommendations; amending the National Electric Code may be warranted.

Burns↗

The distribution of radiant power in a phototherapy unit equipped with a metal halide lamp.

The effective radiant power of a metal halide lamp for phototherapy of neonatal jaundice was measured in an incubator. This new lamp is characterised by an extremely heterogeneous field of irradiance with a high intensity in the centre and a marked decrease towards the sides. The mean radiant intensity in a central area (20 X 40 cm) of the incubator can be compared with the values achieved with standard fluorescent lamps in an incubator lined with white cloth. As the field of irradiance is more homogeneous in the latter case, advances in therapy are not to be expected from the use of metal halide lamps in their present form.

Humans↗

Device for eliminating corneal light reflections during recording of lateral images with a slit lamp.

Corneal reflections produce defects in photographic sections of the lens taken with a slit-lamp biomicroscope for computerized densitometric analysis of cataract opacity. A simple and workable, adjustable antireflection device was built that can be easily adapted to photographic slit lamps, a common instrument in ophthalmology equipment. The slit lamp is a versatile tool for photographing structures in the anterior segment of the eye, particularly the lens. Corneal reflections are eliminated for angles between the light band and a photograph plane ranging from 20 degrees to 90 degrees, with the light band no greater than 0.5 mm and the corneal curvature about 7.6 to 7.9 mm. The device acts by blocking aberrant light rays from the light source that would otherwise be reflected by the mirrorlike surface of the cornea and enter the objective lens. Here we present a prototype designed for the Zeiss slit lamp.

Cornea↗

Light-induced damage of the retina through slit-lamp photography.

BACKGROUND: I report on two patients who suffered severe loss of visual acuity after slit-lamp photography of the anterior eye segment. METHODS: Both patients were pseudophakic and pictures were taken to document the degree of posterior capsule opacification via retroillumination with dilated pupils. Both patients had excellent visual acuity at the time of photography was taken and experienced reduction of to hand movement afterwards. A Zeiss 75 SL device was used for the slit-lamp photography. In cooperation with Carl Zeiss Jena the slit lamp was investigated. RESULTS: Ophthalmoscopy and angiography after photography discovered a central macular defect, similar to a photocoagulation. The visual acuity did not recover. CONCLUSION: Under certain circumstances slit-lamp photography of the anterior eye segment can lead to severe light-induced damage of the retina.

Aged↗

Slit-lamp-adapted optical coherence tomography of the anterior segment.

PURPOSE: To evaluate the diagnostic potential of a slit-lamp-adapted optical coherence tomography (OCT) system as an in vivo imaging device for routine clinical examination of the anterior segment of the eye. PATIENTS AND METHODS: In a pilot study, healthy volunteers and patients with different pathologies of the anterior segment were examined with a slit-lamp-adapted OCT system using 100-200 axial scans with 100-Hz line-scan frequency. The scan length is variable up to 7 mm, and the axial depth is 1.5 mm in tissue. RESULTS: The slit-lamp-adapted OCT system allowed direct biomicroscopic imaging of the measured area. Anatomic structures and morphological changes anterior to the attenuating iris pigment epithelium could be visualized with high accuracy. Biometric analyses of the cornea, the chamber angle, the iris and secondary cataract were possible. Complete demonstration of the chamber angle was difficult due to the backscattering properties of the anterior part of the sclera and the consequent shadowing of the most peripheral part of the iris. CONCLUSIONS: Slit-lamp-adapted OCT is a useful diagnostic tool which allows in vivo microscopic cross-sectional imaging of the anterior segment and precise measurement of ocular structures.

Anterior Eye Segment↗

Rapid diagnosis of Tetracapsuloides bryosalmonae, the causative agent of proliferative kidney disease (PKD) in salmonid fish by a novel DNA amplification method, loop-mediated isothermal amplification (LAMP).

A new molecular diagnostic assay was developed for detection of Tetracapsuloides bryosalmonae the causative agent of proliferative kidney disease (PKD) in salmonid fish using a loop-mediated isothermal amplification method (LAMP). The PKD-LAMP assay amplifies the T. bryosalmonae DNA extracted from infected kidney, under constant temperature of 65 degrees C within 1 h. The required equipment for DNA amplification is only a water bath. The amplification products were detected visually by using SYBR green I dye, which turns green in the presence of amplified products and remains orange in its absence, and by electrophoresis without any difference in the sensitivity of both methods. The developed PKD-LAMP assay demonstrated an exceptionally higher sensitivity than the conventional PCR. PKD-LAMP assay was found to be 100-fold more sensitive than the PCR assay. The developed assay is simple, rapid, cost-effective, specific and highly sensitive. The assay is also characterized by its field applicability, as it does not require the use of sophisticated equipment or skilled personnel.

Animals↗

Differential expression of ABH histo-blood group antigens and LAMPs in infantile hemangioma.

Although infantile hemangioma (IH) are the most common tumors of infancy, the mechanism of their proliferation and involution remains vague. Proliferation, differentiation and death of endothelial cells are the basic processes involved in their pathobiology. Here we hypothesize that the glycoconjugates ABH histo-blood group antigens (HBGA) and lysosome-associated membrane proteins (LAMPs) might be implied in both the differentiation and death of endothelial cells during vascular remodeling in IH. Proliferating and involuting IH were examined immunohistochemically for HGBA and LAMP expression together with vWF and CD31. Proliferative and apoptotic indices were determined. LAMPs were found in immature endothelium of proliferating IH. In involution an increased number of immunopositive cells stained with higher intensity was detected. The enhanced expression might be associated with augmented autophagy required for tissue remodeling during tumor involution. HBGA presented an opposite pattern of expression--they stained intensely the endothelium of mature capillaries, while the immature ones were positive for vWF. The presence of HBGA in endothelial cells of IH may be related to the differentiation process only, as well as to endothelial adhesion and angiogenesis. Novel evidence for differential expression of HBGA and LAMPs in proliferative and involutive phases of IH is presented.

ABO Blood-Group System↗

Measurement of temperature generated by visible-light-cure lamps in an in vitro model.

The dental pulp is vulnerable to cavity preparation and restoration procedures. This vulnerability may be a result of the temperature rise generated by those procedures. When visible-light-cure lamps are used to place composite restorations, they cause the temperature in the pulp to rise. This study measured the temperature rise recorded when six visible-light-cure lamps were tested for 20- and 60-second exposure times. They were also tested in conjunction with an air current passed along the face of the lens in order to lower the temperature. Analysis of the data indicates that the lamps do cause a temperature rise within the pulp chamber--a higher rise the longer the lamp is used. Dentin thickness is important, and air lowers the temperature generated.

Dental Pulp↗

Vitreoretinal surgery with slit-lamp illumination combined with a wide-angle-viewing contact lens.

PURPOSE: To evaluate the feasibility of illuminating the fundus by combining a wide-angle-viewing contact lens and slit lamp attached to a surgical microscope during retinal reattachment surgery and vitrectomy. DESIGN: An interventional study. METHODS: We combined slit-lamp illumination and a wide-angle-viewing contact lens to visualize the fundus during retinal reattachment surgery and vitrectomy. RESULTS: We clearly observed the fundus using this combination approach during conventional retinal reattachment surgery, which we completed without using an indirect ophthalmoscope. With slit-lamp illumination, the wide-angle-viewing contact lens provided a wider area of illumination than a planoconcave contact lens during vitrectomy in addition to an area of illumination as wide as that obtained using a light pipe. CONCLUSIONS: Combining slit-lamp illumination and a wide-angle-viewing contact lens seems to provide a useful alternative method for viewing the fundus during vitreoretinal surgery.

Contact Lenses↗

Detection of yellow head virus in shrimp by loop-mediated isothermal amplification (LAMP).

Reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detecting the structural glycoprotein gene of yellow head virus (YHV). The RT-LAMP assay is a novel method of gene amplification that amplifies nucleic acid with high specificity, sensitivity and rapidity under isothermal conditions with a set of four specially designed primers that recognize six distinct sequences of the target. The whole procedure is very simple and rapid, and reaction time and temperatures were optimized for 60 min at 65 degrees C, respectively. Detection of gene amplification could be accomplished by agarose gel electrophoresis. The standardized RT-LAMP procedure was used to detect YHV in the heart and gill from infected shrimp. Thus, the RT-LAMP assay is extremely rapid, cost-effective, sensitive and specific and has potential usefulness for rapid diagnosis for YHV detection in shrimp.

Base Sequence↗

Development of H5-RT-LAMP (loop-mediated isothermal amplification) system for rapid diagnosis of H5 avian influenza virus infection.

We developed a rapid and sensitive diagnosis system for H5N1 highly pathogenic avian influenza (HPAI) virus infection using an unique gene amplification method, reverse transcriptase loop-mediated isothermal amplification (RT-LAMP). The sensitivity of the system was found to be 100-fold higher than that of ordinary one-step RT-PCR. Moreover, by using viral RNAs extracted from influenza viruses of all 15 HA subtypes, the RT-LAMP system was confirmed to amplify only the RNA of H5 subtype virus. In the surveillance of H5N1 virus infection of wild birds, we detected two positive cases from dead crows found near the affected area with H5N1-HPAI by using RT-LAMP system, although one of two positive cases was missed by RT-PCR. These results suggested that our newly developed RT-LAMP system specific for H5 virus would be a beneficial diagnostic tool for surveillance of recent outbreaks caused by H5N1-HPAI viruses.

Animals↗

Evaluation of loop-mediated isothermal amplification (LAMP), PCR and parasitological tests for detection of Trypanosoma evansi in experimentally infected pigs.

Six surra negative piglets (6-week-old) were infected with Trypanosoma evansi and two uninfected piglets were used as negative controls. Detection performances of various diagnostic tests (LAMP, PCR and parasitological tests) were compared by analysing blood samples collected weekly over a period of 11 weeks. With a two by two analysis without a gold standard, all methods were 100% specific. MI had the highest sensitivity of 65%, while LAMP, PCR, MHCT and TBS had sensitivities of 45, 33, 38 and 24%, respectively. However, when the analysis was done using MI as a gold standard, the sensitivity of MHCT was the highest at 53% followed by LAMP, PCR and TBS at 49, 44 and 35%, respectively. All methods gave high specificity above 60%. This study validates LAMP as an alternative method for the diagnosis of surra.

Animals↗