Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Hydrodynamics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Drug release from hydrocolloid embeddings with high or low susceptibility to hydrodynamic stress.

PURPOSE: The subject of the study was the influence of hydrodynamic stress on the drug release from direct compressed hydrocolloid embeddings. Additionally a correlation between the release kinetics and different polymer characterising parameters was attempted. METHODS: The drug release was fitted to an expanded Korsmeyer equation to describe the release kinetics. The influence of the stirring Dissolution Time (MDT) was expressed as quotient of the MDT's at the stirring rate of 200 and 100 min-1. RESULTS: If the drug release followed the square root of time kinetics, nearly no effect of the agitation speed on the release rate was observed. To achieve this diffusion controlled drug release the developing gel layer had to be hydrated very well and resistant against erosion (viscosity of at least 4000 mPa.s of the 2% polymer solution and a small expansion of the swelling gel especially at the beginning of the release). The erosion controlled zero order release was generally much affected by the hydrodynamic stress except for some hydrocolloids with incomplete swelling. Thus, it was possible to define a new release mechanism, the polymer particle erosion. The drug release was controlled by the attrition of partially swollen polymer particles and not by the polymer dissolution or drug diffusion. CONCLUSIONS: Polymer particle erosion or diffusion control should be the release controlling mechanisms for negligible influence of hydrodynamic stress.

Colloids↗

Lifetime of the P-selectin-carbohydrate bond and its response to tensile force in hydrodynamic flow.

Selectins tether to the blood vessel wall leukocytes that are flowing in the bloodstream and support subsequent labile rolling interactions as the leukocytes are subjected to hydrodynamic drag forces. To support this rolling, selectins have been proposed to have rapid bond association and dissociation rate constants, and special mechanical properties linking tensile forces and bond dissociation. We have visualized transient tethering and release of neutrophils in hydrodynamic flow on lipid bilayers containing densities of P-selectin below those required to support rolling. We report here that transient tethers had first-order kinetics and other characteristics suggesting a unimolecular interaction between P-selectin and its glycoprotein ligand (PSGL-1). The unstressed dissociation constant (off rate) was 1 s-1. Hydrodynamic shear stresses of up to 1.1 dyn cm-2, corresponding to a force on the bond of up to 110 pN, increased the off rate only modestly, to 3.5 s-1. The data was adequately matched by a proposed equation relating off rate to the exponential of tensile force on the bond and the bond interaction distance, and gave a bond interaction distance of 0.5 A. This distance is compatible with hydrogen and metal coordination bonds between P-selectin and PSGL-1. Fast on and off rates, together with the high tensile strength of the selectin bond, appear necessary to support rolling at physiological shear stresses.

Carbohydrates↗

Hydrodynamic turbulence cannot transport angular momentum effectively in astrophysical disks.

The most efficient energy sources known in the Universe are accretion disks. Those around black holes convert 5-40 per cent of rest-mass energy to radiation. Like water circling a drain, inflowing mass must lose angular momentum, presumably by vigorous turbulence in disks, which are essentially inviscid. The origin of the turbulence is unclear. Hot disks of electrically conducting plasma can become turbulent by way of the linear magnetorotational instability. Cool disks, such as the planet-forming disks of protostars, may be too poorly ionized for the magnetorotational instability to occur, and therefore essentially unmagnetized and linearly stable. Nonlinear hydrodynamic instability often occurs in linearly stable flows (for example, pipe flows) at sufficiently large Reynolds numbers. Although planet-forming disks have extreme Reynolds numbers, keplerian rotation enhances their linear hydrodynamic stability, so the question of whether they can be turbulent and thereby transport angular momentum effectively is controversial. Here we report a laboratory experiment, demonstrating that non-magnetic quasi-keplerian flows at Reynolds numbers up to millions are essentially steady. Scaled to accretion disks, rates of angular momentum transport lie far below astrophysical requirements. By ruling out purely hydrodynamic turbulence, our results indirectly support the magnetorotational instability as the likely cause of turbulence, even in cool disks.

Journal Article↗

Hydroporation as the mechanism of hydrodynamic delivery.

We have reported that a rapid tail vein injection of a large volume of plasmid DNA solution into a mouse results in high level of transgene expression in the liver. Gene transfer efficiency of this hydrodynamics-based procedure is determined by the combined effect of a large volume and high injection speed. Here, we show that the hydrodynamic injection induces a transient irregularity of heart function, a sharp increase in venous pressure, an enlargement of liver fenestrae, and enhancement of membrane permeability of the hepatocytes. At the cellular level, our results suggest that hepatic delivery by the hydrodynamic injection is accomplished by the generation of membrane pores in the hepatocytes.

Animals↗

Gene therapy progress and prospects: hydrodynamic gene delivery.

Over the last few years, hydrodynamic tail vein delivery has established itself as a simple, yet very effective method for gene transfer into small rodents. Hydrodynamic delivery of plasmid DNA expression vectors or small interfering RNA allows for a broad range of in vivo experiments, including the testing of regulatory elements, antibody generation, evaluation of gene therapy approaches, basic biology and disease model creation (non-heritable transgenics). The recent development of the hydrodynamic limb vein procedure provides a safe nucleic acid delivery technique with equally high efficiency in small and large research animals and, importantly, the prospects for clinical translation.

Animals↗

Hydrodynamic simulation of cell docking in microfluidic channels with different dam structures.

The immobilization of biological cells in micro-devices requires high efficiency and easy control while maintaining cell viability. One approach for cell immobilization is to utilize constriction structures such as dams to trap cells in microfluidics. In this paper, we present a comprehensive hydrodynamic analysis of two different types of constriction structures for cell immobilization: dams either in perpendicular or in parallel to the main flow route. Various structural models and experimental conditions were compared for cell docking and alignment, and the pressure and velocity profiles of the flow in the micro-channels and the hydrodynamic force and shear stress on the docked cells were calculated based on fluid dynamic theory and numerical simulation. The effects of the dam structures and cell docking on the flow properties, the transportation efficiency, and the induced stress on the docked cells were analyzed. Improved hydraulic pressure profiles in the auxiliary inlets were discussed for the modulation of the flow characteristics and attenuation of hydrodynamic forces exerted on the cells. Furthermore, a new design combining the advantages of perpendicular and parallel dam structures was proposed for cell-based microfluidics.

Cell Physiological Phenomena↗

In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position.

The non-fully open phenomenon of the advancing standard medical bileaflet heart valves (the ATS valve) are frequently observed in clinical cases, even though there is no problem with their hemodynamic function. The movement of the leaflets was affected easily by the transvalvular flow because of the unique open pivot design of the ATS valve. In this paper, a comparative in vitro hydrodynamic test was conducted among 3 different types of bileaflet valves, and the effect of different shapes of downstream conduits, which induce different transvalvular flow, on hydrodynamic performance was studied. Three bileaflet valves, the ATS valve, CarboMedics valve (CM), and St. Jude Medical valve (SJM), with an annulus diameter of 29 mm for the mitral position were chosen throughout our experiments. First, pressure drops across the valves under steady flow were measured. Then, the valves were tested at the mitral position with our pneumatically driven pulsatile pump. In this pulsatile flow study, 2 different conduits (straight shape and abrupt enlargement shape) were in turn incorporated at the downstream portion of the mitral valve. A high-speed video camera was employed to observe leaflet movements. In a steady-flow test, the ATS and the SJM produced the same pressure drop, but the CM recorded a higher value. In the pulsatile study, it was observed that the ATS leaflets did not open fully in the mitral position when the downstream conduit with an abrupt enlargement shape was incorporated. However, the CM and the SJM always indicated a fully open movement regardless of the shape of downstream conduits. When the straight downstream conduit was incorporated, the ATS produced a similar pressure drop to that of the SJM, which coincided with the steady test results. When the enlargement conduit was incorporated, however, the ATS presented the lowest pressure drop despite the non-fully open movement. The conduit shape at the valve downstream had a significant influence on the closing volume. These findings indicate that the conduit shape at the valve outlet can affect the hydrodynamic characteristics of bileaflet valves.

Blood Pressure↗

Tracer diffusion in hard sphere fluids from molecular to hydrodynamic regimes.

Molecular dynamics is employed to investigate tracer diffusion in hard sphere fluids. Reduced densities (rho*=rhosigma(3), sigma is the diameter of bath fluid particles) ranging from 0.02 to 0.52 and tracers ranging in diameter from 0.125sigma to 16sigma are considered. Finite-size effects are found to pose a significant problem and can lead to seriously underestimated tracer diffusion constants even in systems that are very large by simulation standards. It is shown that this can be overcome by applying a simple extrapolation formula that is linear in the reciprocal cell length L(-1), allowing us to obtain infinite-volume estimates of the diffusion constant for all tracer sizes. For higher densities, the range of tracer diameters considered spans diffusion behavior from molecular to hydrodynamic regimes. In the hydrodynamic limit our extrapolated results are clearly consistent with the theoretically expected slip boundary conditions, whereas the underestimated values obtained without extrapolation could easily be interpreted as approaching the stick limit. It is shown that simply adding the Enskog and hydrodynamic contributions gives a reasonable qualitative description of the diffusion behavior but tends to overestimate the diffusion constant. We propose another expression that fits the simulation results for all densities and tracer diameters.

Journal Article↗

Liquid friction on charged surfaces: from hydrodynamic slippage to electrokinetics.

Hydrodynamic behavior at the vicinity of a confining wall is closely related to the friction properties of the liquid/solid interface. Here we consider, using molecular dynamics simulations, the electric contribution to friction for charged surfaces, and the induced modification of the hydrodynamic boundary condition at the confining boundary. The consequences of liquid slippage for electrokinetic phenomena, through the coupling between hydrodynamics and electrostatics within the electric double layer, are explored. Strong amplification of electro-osmotic effects is revealed, and the nontrivial effect of surface charge is discussed. This work allows us to reconsider existing experimental data, concerning zeta potentials of hydrophobic surfaces and suggests the possibility to generate "giant" electro-osmotic and electrophoretic effects, with direct applications in microfluidics.

Journal Article↗

Distant touch hydrodynamic imaging with an artificial lateral line.

Nearly all underwater vehicles and surface ships today use sonar and vision for imaging and navigation. However, sonar and vision systems face various limitations, e.g., sonar blind zones, dark or murky environments, etc. Evolved over millions of years, fish use the lateral line, a distributed linear array of flow sensing organs, for underwater hydrodynamic imaging and information extraction. We demonstrate here a proof-of-concept artificial lateral line system. It enables a distant touch hydrodynamic imaging capability to critically augment sonar and vision systems. We show that the artificial lateral line can successfully perform dipole source localization and hydrodynamic wake detection. The development of the artificial lateral line is aimed at fundamentally enhancing human ability to detect, navigate, and survive in the underwater environment.

Animals↗

Real-time visualization of intracellular hydrodynamics in single living cells.

Intracellular water concentrations in single living cells were visualized by nonlinear coherent anti-Stokes Raman scattering (CARS) microscopy. In combination with isotopic exchange measurements, CARS microscopy allowed the real-time observation of transient intracellular hydrodynamics at a high spatial resolution. Studies of the hydrodynamics in the microorganism Dictyostelium discoideum indicated the presence of a microscopic region near the plasma membrane where the mobility of water molecules is severely restricted. Modeling the transient hydrodynamics eventuated in the determination of cell-specific cytosolic diffusion and plasma membrane permeability constants. Our experiments demonstrate that CARS microscopy offers an invaluable tool for probing single-cell water dynamics.

Animals↗

Anti-tumor effect of intravenous TNFalpha gene delivery naked plasmid DNA using a hydrodynamics-based procedure.

High levels of foreign gene expression in mouse hepatocytes can be achieved by the rapid injection of a large volume of naked plasmid (pDNA) into animals via the tail vein, the so-called hydrodynamics-based procedure. In this study, we evaluated the efficacy of hydrodynamics-based tumor necrosis factor alpha (TNFalpha) transfer for tumor treatment, in which the naked pDNA encoding TNFalpha was administered into the tail vein following an intravenous injection of B16 melanoma cells. The mice treated with TNFalpha-expressing pDNA displayed a profound reduction in lung metastasis. These results suggest that the hydrodynamics-based transfer of naked pDNA is a convenient and efficient method of TNFalpha gene therapy against metastatic tumors.

Animals↗

Adaptations to increasing hydraulic stress: morphology, hydrodynamics and fitness of two higher aquatic plant species.

Sessile organisms often exhibit morphological changes in response to permanent exposure to mechanical stimulation (wind or water movements). The adaptive value of these morphological changes (hydrodynamic performance and consequences on fitness) has not been studied extensively, particularly for higher plants submitted to flow stress. The aim was to determine the adaptive value of morphological patterns observed within two higher aquatic plant species, Berula erecta and Mentha aquatica, growing along a natural flow stress gradient. The hydrodynamic ability of each ramet was investigated through quantitative variables (drag coefficient and E-value). Fitness-related traits based on vegetative growth and clonal multiplication were assessed for each individual. For both species, the drag coefficient and the E-value were explained only to a limited extent by the morphological traits used. B. erecta exhibited a reduction in size and low overall plant drag at higher flow velocities, despite high drag values relative to leaf area, due to a low flexibility. The plants maintained their fitness, at least in part, through biomass reallocation: one tall ramet at low velocity, but shorter individuals with many interconnected stolons when flow velocity increased. For M. aquatica, morphological differences along the velocity gradient did not lead to greater hydrodynamic performance. Plant size increased with increasing velocities, suggesting the indirect effects of current favouring growth in high velocities. The fitness-related traits did not demonstrate lower plant fitness for high velocities. Different developmental constraints linked to plant morphology and trade-offs between major plant functions probably lead to different plant responses to flow stress.

Adaptation, Physiological↗

Stable blood lubricated hydrodynamic journal bearing with magnetic loading.

The Cleveland Clinic Foundation's Innovative Ventricular Assist System (IVAS) is distinguished by the use of a special hydrodynamic journal bearing to support the rotating assembly of the blood pump. In a permanently implanted blood pump, this bearing's characteristics of long life and high reliability are of paramount importance. In addition, this bearing's inherent self-pumping flow and the axial through flow caused by an imposed end-to-end pressure difference provides good washing, thus guarding against deposition. The basic computer analysis and preliminary testing results of this bearing were previously presented. This article reports the ongoing studies (both analytic and in vitro tests) on this innovative bearing as a component of the IVAS in general, with particular emphasis on its stable operating characteristics and reliability. The absence of vibration attributable to hydrodynamic instabilities related to the thick fluid film are both calculated and demonstrated during testing. A stable operating center of the rotor is shown to be inherent under magnetic side loads and resulting hydrodynamic bearing forces. A low shear as a result of large fluid-film thicknesses has been calculated, and low hemolysis has been shown by in vitro testing. Several unique design features of the bearing are believed to be responsible for this high level of performance.

Heart-Assist Devices↗

Mechanical assistance for enhancement of in vitro effectiveness for hydrodynamic thrombectomy.

OBJECTIVE: To determine whether the efficacy for clot removal and procedure-related peripheral particle embolization for the hydrodynamic thrombectomy device CF 105 AngioJet (CF 105) can be enhanced with the use of guiding catheters and an occlusion balloon in an in-vitro flow model. METHODS: Thrombectomy of clots (n = 97) from 5-day-old human blood (range, 9.28-9.77 g) was performed with the CF 105 alone, with additional guide wires (CF 1050.014/0.018), with a 30 degree angled tip (CF 10530 degrees), with guiding catheters (CF 105MP/HS), and with an additional occlusion balloon (CF 105OB) in a flow model (flow 1 L/min) of silicone tubes (inner tube diameter, 7 mm). RESULTS: Mean thrombectomy time ranged from 28.71 seconds (CF 105OB) to 37.02 seconds (CF 10530 degrees). When a guide wire was used, the time for thrombectomy was not prolonged. None of the devices tested worked isovolumetrically. The ratio of applied saline and aspirated fluid (0.34) for CF 105 alone was significantly better than for CF 1050.014/0.018 (0.49/0.60; for both P < 0.001). Compared with CF 105 alone (273.16 mg), wall-adhesive thrombus was reduced significantly with CF 105MP (43.66 mg), CF 105HS (48.66 mg), and CF 10530 degrees (97.27 mg; P < 0.001 for all). Compared with the highest rate of embolism for CF 105 alone (4.62%), CF 105OB (2.50%; P < 0.001), CF 105HS (3.04%; P < 0.001), CF 105MP (3.49%; P < 0.001), and CF 105018 (3.64%; P < 0.001) produced better ratios. CONCLUSIONS: The use of guiding catheters and occlusion balloons is feasible to enhance hydrodynamic thrombectomy in vitro. This combination reduces procedure-related peripheral particle embolization and wall-adhesive thrombus during hydrodynamic thrombectomy. To avoid blood loss, the device should be used only with a 0.018" guide wire.

Adult↗

Generalized hydrodynamics in the transient regime and irreversible thermodynamics.

In this article the thermodynamically consistent formulation of generalized hydrodynamics is reviewed and applications to shock-wave structures, ultrasonic wave absorption and dispersion and microchannel flows of the generalized hydrodynamics so formulated are discussed. The kinematic terms of the constitutive equations in the generalized hydrodynamic equations for liquids, which have been calculated by means of non-equilibrium grand canonical ensemble, are also presented.

Journal Article↗

Grains and gas flow: molecular dynamics with hydrodynamic interactions

We introduce a simple model for granular flows with hydrodynamic interactions. The hydrodynamic part of the model relies on a coarse grained picture of the granular medium, and is described in terms of the pressure by a local Darcy law. The model thus avoids the large computational cost of solving for detailed hydrodynamic flow fields between grains. The solid phase is described explicitly in terms of grains by event driven molecular dynamics. In the first two test cases, the model is employed to simulate a sedimenting and a fluidized particle bed. It is shown that the qualitative aspects of both phenomena are correctly captured: The sedimenting particles form a sharp upper front and move according to the theoretical prediction, which is also given. When external pressure gradients are applied the bed fluidizes, and spontaneously produces bubbles of the shape observed experimentally. Moreover, these bubbles are seen to merge, as is experimentally observed.

Journal Article↗

Generalized hydrodynamic theory of shock waves in rigid diatomic gases.

Generalized hydrodynamic theory of shock waves is phenomenologically developed for rigid diatomic molecules. The generalized hydrodynamic equations developed are thermodynamically consistent, obeying the laws of thermodynamics. They reduce to the Navier-Stokes-Fourier theory of the classical hydrodynamics in the limit of low Mach number. The theory is applied to study the one-dimensional shock wave structure of nitrogen gas, which is treated as a rigid molecule. An excellent agreement with experiment is obtained for the inverse shock widths up to Mach number 10 reported in the literature. The theory is applicable to arbitrary dimension. On the basis of direction field singularities of the velocity and temperature evolution equations of the theory, it is possible to predict that the shock solutions exist for all Mach numbers in the case of one-dimensional shock waves studied.

Journal Article↗