Esophageal cancer and the esophagus: challenges and potential strategies for selective cytoprotection of the tumor-bearing organ during cancer treatment.

Esophageal cancer is treated optimally with a combined-modality approach according to most clinical investigators. Cytotoxic chemotherapy and ionizing radiotherapy, given in a concomitant schedule, has yielded superior survival rates compared with radiotherapy alone. However, mucosal toxicity from such treatment may compromise quality of life and may mandate an unscheduled break in therapy in some patients who do not respond readily to standard treatments such as antacids; combinations of viscous xylocaine, aluminum hydroxide-magnesium carbonate, and diphenhydramine hydrochloride; oral liquid morphine sulfate, hydrocodone bitartrate, or acetaminophen. Hence, a number of alternative strategies that are designed to either prevent or limit toxicity to normal tissues without diminishing the antitumor effect are being tested. These include the use of conformal radiotherapy treatment planning techniques, amifostine (Ethyol, WR-2721), gene therapy via intratumoral injection of manganese superoxide dismutase-plasmid/liposome, glutamine, melatonin, omega-3-polyunsaturated fatty acids, transforming growth factor, flavonoid compounds, probucol, and keratinizing growth factor. An ongoing phase 2 trial by the North Central Cancer Treatment Group (NCCTG) may help clarify a role for cytoprotectants in patients receiving combined-modality therapy for esophageal cancer.

Amifostine↗

A retrospective study of the effect of postoperative indomethacin rectal suppositories on the need for narcotic analgesia in patients who had a cesarean delivery while they were under regional anesthesia.

OBJECTIVE: This study was undertaken to assess the efficacy of rectal indomethacin as an analgesic after cesarean delivery, comparing narcotic usage in patients receiving indomethacin with patients who received only standard narcotic analgesics. STUDY DESIGN: A retrospective study of patient records consisting of 297 women who underwent cesarean delivery while they were under regional anesthesia in a medium-sized community hospital from February 1996 through December 1999. Narcotic usage was determined as morphine equivalents whereby 10 mg morphine sulfate equals 30 mg oxycodone equals 50 mg hydrocodone equals 75 mg meperidine. Indomethacin was administered as 50-mg rectal suppositories. Statistical analysis was done by Pearson correlation and independent Student t test analysis. RESULTS: Narcotic usage was reduced by an average of 16 morphine equivalents (28%) in the indomethacin group. Pearson correlation revealed correlation at the.01 level; independent Student t test analysis revealed a P value of.001. Thus the mean amount of narcotic analgesic administered was significantly less in patients treated with indomethacin rectal suppositories. CONCLUSION: In this uncontrolled trial the use of indomethacin rectal suppositories resulted in a significant reduction in narcotic use in the postcesarean hospital recovery period as measured in morphine equivalents.

Analgesia↗

Drug identification calls from law enforcement received by Texas poison control centers, 2002-2004.

Aside from calls involving human exposures to potentially toxic substances, poison control centers handle other types of calls such as drug identifications (drug IDs). A portion of drug ID requests originates from law enforcement. The objective of this study was to describe such drug ID requests from law enforcement received by Texas poison control centers during 2002-2004. These calls were examined with respect to year of call, location of caller, and type of drug. There were in total 26,752 drug ID calls (involving 27,800 individual drug ID requests) from law enforcement, representing 3% of total calls and 16% of all drug ID calls received. The number of drug ID calls received from law enforcement and the proportion of total calls and all drug ID calls these represented increased from 2002 to 2004. A disproportionate number of the drug ID requests originated from eastern-central Texas. The most frequently involved drugs were analgesics (particularly acetaminophen and hydrocodone), sedatives and related drugs (particularly alprazolam), and muscle relaxants (particularly carisoprodol).

Humans↗

Renal infarction during the use of rizatriptan and zolmitriptan: two case reports.

Rizatriptan and zolmitriptan are both used to relieve acute migraine and cluster headaches. The mechanism of action is similar to the other triptans, in that they reverse abnormal cerebral vasodilation through their activity as 5-HT1B receptor agonists. Triptan-induced vasoconstriction is attributed to its activity on peripheral 5-HT1B receptors and has rarely been reported to result in stroke, myocardial infarction and ischemic colitis. We present two cases of renal infarction associated with therapeutic triptan use. The first patient is a 57-year-old man with a history of hypertension that was well controlled on valsartan and hydrochlorothiazide. He was recently diagnosed with cluster headaches and was treated with indomethacin, prednisone, butalbital-acetaminophen-caffeine and hydrocodone without relief. He then received two therapeutic doses of rizatriptan on each of the two days prior to presentation. Subsequently, he presented to the emergency department complaining of nausea, vomiting and right-sided abdominal pain. A computerized tomography (CT) scan of the abdomen and pelvis with intravenous contrast revealed a very large wedge shaped infarction of the right kidney. The second patient is a 34-year-old man with a past medical history significant only for life-long migraine headaches successfully treated for the past six years with zolmitriptan. Shortly after taking one therapeutic dose of zolmitriptan, he presented to the emergency department complaining of nausea and left-sided abdominal pain. A CT scan of the abdomen and pelvis with intravenous contrast revealed multiple wedge-shaped infarctions of the left kidney. Renal infarction was confirmed in both patients by arteriogram of the renal arteries. Although both rizatriptan and zolmitriptan are effective in the treatment of migraine and cluster headaches, they may induce peripheral vasospasm leading to renal infarction.

Adult↗

Effect of gastrointestinal bleeding and oral medications on acquisition of vancomycin-resistant Enterococcus faecium in hospitalized patients.

There has been minimal investigation of medications that affect gastrointestinal function as potential risk factors for the acquisition of vancomycin-resistant enterococci (VRE). We performed a retrospective case-control study, with control subjects matched to case patients by time and location of hospitalization. Strict exclusion criteria were applied to ensure that only case patients with a known time of acquisition of VRE were included. Control patients were patients with > or =1 culture negative for VRE. The risk factors identified were use of vancomycin (odds ratio [OR], 3.2; 95% confidence interval [CI], 1.7-6.0; P=.0003), presence of central venous lines (OR, 2.2; 95% CI, 1.04-4.6; P=.04), and use of antacids (OR, 2.9; 95% CI, 1.5-5.6; P=.002). Two protective factors included gastrointestinal bleeding (OR, 0.26; 95% CI, 0.08-0.79; P=.02) and use of Vicodin (Knoll Labs; hydrocodone and acetaminophen; OR, 0.93; 95% CI, 0.90-0.97; P=.0003). Changes in gastrointestinal function, whether due to bleeding or to the effects of oral medications, may affect whether patients become colonized with VRE.

Administration, Oral↗

Rapid communication: laparoscopic Anderson-Hynes dismembered pyeloplasty using the da Vinci robot: technical considerations.

PURPOSE: To present our initial experience with laparoscopic pyeloplasty utilizing the da Vinci robot for upper tract reconstruction. CASE REPORT: A four-port transperitoneal approach was used in a 73-year-old man. The ureteropelvic (UPJ) obstruction was identified with a crossing vessel. After dismemberment of the UPJ, the renal pelvis was trimmed and reconstructed using the da Vinci robot. The total operative time was 5 hours; the time spent for reconstruction was 45 minutes. Blood loss was <150 mL. The postoperative analgesic requirement was 8 mg of morphine and 25 mg of hydrocodone. There were no intraoperative or postoperative complications. CONCLUSION: The da Vinci robot can serve as a vital surgical tool during pyeloplasty with extensive reconstruction.

Aged↗

A solid phase extraction technique for the isolation and identification of opiates in urine.

A quantitative method was developed for the simultaneous analysis of morphine, codeine, hydromorphone, hydrocodone, and oxycodone in urine by gas chromatography/mass spectrometry. Samples were hydrolyzed with beta-glucuronidase and then extracted by solid phase extraction on Bond Elute Certify cartridges at pH 6.8. Nalorphine was used as the internal standard. The opiates were analyzed by full-scan electron impact GC/MS after derivatization with acetic anhydride-pyridine. The standard curves for all five drugs were linear between 50 and 1000 ng/mL, with correlation coefficients exceeding 0.99. Coefficients of variation were less than 7%. The method was applied to the analysis of postmortem urines positive by EMIT opiate assay, and the effect of the hydrolysis procedure on recovery of each drug was measured. The results indicate that the hydrolysis procedure is effective in increasing the recovery of all five drugs from urine. The described method enables the laboratory to identify the five opiates most commonly encountered in forensic and clinical laboratories. Its sensitivity for all five drugs is well below GC/MS cutoffs for codeine and morphine employed in NIDA laboratories, and it provides for conclusive full-scan drug identification.

Chemistry Techniques, Analytical↗

Qualitative detection of opiates in sweat by EIA and GC-MS.

Sweat was collected with the PharmChek sweat patch, and drugs were eluted from the collection pad of the patch. A solid-phase enzyme immunoassay (EIA) using microtiter plates was modified for the analysis of opiates in sweat. After opiate administration, sweat contains primarily parent opiate (heroin, codeine) and lipophilic metabolites (6-monoacetylmorphine [6-MAM]). The immunoassay was determined to have a cross-reactivity with codeine of 588%, with hydrocodone of 143%, with diacetylmorphine of 28%, and with 6-MAM of 30% relative to 100% for the morphine calibrators. The optimum cutoff concentration for this modified assay was determined by receiver operator characteristic analysis using 215 patches from 95 subjects to be 10 ng/mL morphine equivalents. At this cutoff concentration the assay had a diagnostic sensitivity of 86.9% and a diagnostic specificity of 92.8% versus gas chromatography-mass spectrometry (GC-MS), which was the reference method. The positive predictive value at a prevalence of 50% was 86%. The intra-assay precision at 10 ng/mL was 7.8%, and the interassay coefficient of variation (CV) was 39%. Analysis of spiked patches around the cutoff gave a percent positive threshold of approximately 50% between 10 and 15 ng/mL and a 95% confidence level for a positive result by the EIA between 20 and 25 ng/mL. Eighteen possible adulterants that could be injected into or under the patch were studied. Two (tile cleaner and detergent) can cause false-positive responses in the immunoassay. Two adulterants reduced response to spiked drug (Visine eye drops and Ben Gay ointment), which could cause a false-negative response. All results were confirmed by GC-MS. The clinical sensitivity and specificity for detecting drug use by analyzing sweat collected from human subjects following known doses of codeine (0, 30, and 60 mg orally) or heroin (20 mg intravenously) were 76 and 100%, respectively.

Calibration↗

Detection of drugs of abuse in nails.

Postmortem toenail samples were used for the detection of cocaine (COC), benzoylecgonine (BZE), norcocaine (NCOC), cocaethylene (CE), morphine (MOR), 6-monoacetylmorphine (6-MAM), codeine (COD), and hydrocodone (HDC). After the toenail clippings were washed with methanol, they were solubilized in 0.1 M potassium phosphate (pH 5.0). The drugs of interest, along with internal standards, were isolated by solid-phase extraction followed by derivatization with N-methyl-N-trimethylsilyl-trifluoroacetamide. The derivatized products were analyzed by gas chromatography-mass spectrometry operated in the selective ion monitoring (SIM) mode. The limit of quantitation for all analytes was 0.3 ng on column. The quantities of drugs found in toenails of each of 46 decedents were compared with those of their corresponding postmortem fluids. The toenails of the 46 decedents were tested for COC, BZE, NCOC, and CE, and 34 of the collected samples were also tested for opiates. COC and BZE concentrations ranged from 0.20 to 140.17 (n = 20) and 0.30 to 315.44 ng/mg (n = 21), respectively. NCOC concentrations of 6.78 and 0.66 ng/mg and CE concentrations of 2.60 and 0.73 ng/mg were detected in two of the decedents' toenails. MOR and 6-MAM were detected in three sets of toenails at average concentrations of 0.37 and 0.89 ng/mg, respectively. COD was detected in two sets of specimens at concentrations of 3.07 and 1.02 ng/mg. HDC (0.62 ng/mg) was found in only one set of specimens.

Gas Chromatography-Mass Spectrometry↗

Fast screening for drugs of abuse by solid-phase extraction combined with flow-injection ionspray-tandem mass spectrometry.

A fast analytical approach for the simultaneous quantitative screening for illicit drugs in serum and urine without tedious chromatographic separation steps was developed by combining solid-phase extraction (SPE) followed by flow-injection analysis (FIA) with ionspray-ionization and tandem mass spectrometry (MS-MS) detection using a PE Sciex API 300 triple-quadrupole MS. MS-MS analysis was performed by sequentially isolating the precursor ions of the analytes and their deuterated standards with subsequent fragmentation and monitoring of one fragment ion for each substance. A multiple-reaction monitoring experiment was set up for morphine (MO), codeine (COD), amphetamine (AMP), benzoylecgonine (BZE), and their deuterated analogues. For method evaluation, serum samples spiked with 2-1000 ng of each drug and deuterated standards were extracted by mixed-mode SPE, redissolved in CH3CN-NH4OAc-buffer, and directly injected by flow injection into the ionspray source. The specificity of this new method was demonstrated by testing compounds with similar chemical structure for interferences from the analytes of interest (e.g., dihydromorphone, morphine glucuronide, and 6-monoacetylmorphine with MO; dihydrocodeine and hydrocodone with COD; cocaine [COC] and ecgonine methylester with BZE; methamphetamine with AMP). The possibility of interferences of such compounds with the FIA-ionspray-MS-MS screening method is discussed. Spiked serum samples and serum and urine samples from drug addicts and victims of drug abuse were analyzed with FIA-MS-MS and, after derivatization, with gas chromatography-mass spectrometry (GC-MS). Comparable quantitative results were obtained with both methods; no interferences with metabolites or other compounds were found. The FIA-ionspray-MS-MS method is a fast, quantitative, sensitive, and highly specific alternative method to drug-screening by immunoassays, high-performance liquid chromatography, and GC-MS. It can be used for the simultaneous detection of different drugs and metabolites such as opiates, COC, AMP derivatives, and many other drugs.

Chromatography, Gas↗

Self-intoxication with morphine obtained from an infusion pump.

A 36-year-old Caucasian male was found unresponsive by his wife. He had white foam around his mouth and was pronounced dead shortly thereafter. He had a history of back pain and was treated with intrathecal morphine because of his previous addiction to oral opiate medications. Because of crimping of the pump catheter, it was replaced 4 days before his death. Toxicological findings included urine screen positive for amitriptyline, nortriptyline, opiates, hydrocodone metabolites, ibuprofen, acetaminophen, caffeine, nicotine, and metabolite. Drug concentrations were as follows: blood, 0.260 mg/L amitriptyline, 0.160 mg/L nortriptyline, 0.460 mg/L unconjugated morphine, and 0.624 mg/L total morphine; vitreous humor, 0.034 mg/L unconjugated morphine and 0.080 mg/L total morphine; and cerebrospinal fluid, 0.099 mg/L unconjugated morphine and 0.095 mg/L total morphine. Shortly after death, the volume of the residual pump reservoir was only 8 mL instead of the expected 17 mL. Testing by the FDA showed that the pump was functional. The residual content of the pump accounted for only 230 mg instead of the expected 488 mg. The high blood-morphine concentrations did not correlate with the intrathecal infusion dose. The symptoms were consistent with opiate overdose, possibly by injection of morphine withdrawn from the pump reservoir. The cause of death was determined to be fatal morphine self-intoxication, and the manner of death was accidental. This case is intended to alert regulatory agencies, pain management health professionals, pathologists, and toxicologists to the abuse potential of one of the newer analgesic-delivery systems.

Adult↗

Detection of cocaine analytes and opiates in nails from postmortem cases.

Postmortem fingernail and toenail specimens were utilized for the detection of cocaine analytes and opiates. Nail clippings were obtained from suspected overdoses and/or drug users. Nail clippings were washed with methanol and then solubilized in 0.1M potassium phosphate (pH 5.0). Analytes were isolated from the solubilized nails and methanolic washes by solid-phase or liquid-liquid extraction techniques. Quantitation was performed by gas chromatography-mass spectrometry. Clippings from each hand and foot were analyzed separately for comparison purposes. Concentrations of all the analytes were significantly higher in fingernails than in toenails. Cocaine analytes were detected in the nails of 15 cases with the following concentration ranges (ng/mg): cocaine (n = 15) 1.2-414.1; benzoylecgonine (n = 15) 1.4-170.3; ecgonine methyl ester (n = 14) 0.19-27.0; norcocaine (n = 12) 0.11-32.7; cocaethylene (n = 2) 0.08-2.93. Opiates were detected in 17 cases with the following concentration ranges (ng/mg): morphine (n = 15) 0.05-407.9; 6-acetylmorphine (n = 15) 0.04-504.0; codeine (n = 9) 0.06-8.84; hydromorphone (n = 4) 0.02-0.45. Oxycodone and hydrocodone were each detected in one case. The extent of drug incorporation due to external contamination was evaluated by comparing the differences in the amount of drugs detected in fingernails and toenails, along with the corresponding washes of those nails. These results demonstrate the usefulness of nails as postmortem specimens in detecting drugs of abuse.

Cocaine↗

Simultaneous quantitation of opioids in blood by GC-EI-MS analysis following deproteination, detautomerization of keto analytes, solid-phase extraction, and trimethylsilyl derivatization.

Seven opioid analytes including codeine, morphine, 6-acetylmorphine, hydrocodone, hydromorphone, oxycodone, and oxymorphone were detected in postmortem blood (n > 1000). Two milliliters of specimen was deproteinated with approximately 2.5 mL of methanol and derivatized with hydroxylamine before solid-phase extraction and derivatization with BSTFA + 1% TMCS. Extracts were assayed by gas chromatography-electron impact-mass spectrometry utilizing selected ion mode. One-microliter aliquots were injected onto an HP-1MS capillary column (30 m x 0.25-mm i.d., 0.25 microm) with a helium linear velocity of 62 cm/s. Temperature programming began at 160 degrees C (hold 0 min), then increased at rates of 35 degrees C/min to 195 degrees C, 5 degrees C/min to 240 degrees C, and 30 degrees C/min to 300 degrees C (hold 2 min) resulting in a total run time of 14-min. Quantitative determinations were based on the ratios of the analyte peak areas to the corresponding deuterated analogues. Calibration curves were linear for the following concentrations: 10-500 ng/mL (6-AM), 100-2000 ng/mL (oxycodone), and 50-1000 ng/mL (all other opioids). LOQs ranged from 5 ng/mL (6-AM) to 20 ng/mL (oxycodone). Between-run precision yielded CVs ranging from 2.79% to 5.34% (n = 12). These data suggest that methanolic deproteination and dual derivatization improve separation and simultaneous quantitation of seven opioid analytes in difficult matrices.

Forensic Medicine↗

Evaluation of the Cedia heroin metabolite (6-AM) immunoassay with urine specimens from A criminal justice drug-testing program.

The ability to differentiate illicit from legitimate drug use in a drug-testing program would decrease costs by reducing the number of screening specimens requiring confirmation and also reduce the stigma attached to positive preliminary test results. Because many screening tests for drug detection use immunoassays, increasing the specificity of these tests has been a goal of manufacturers. In this study we evaluated the utility of one such assay, the Cedia heroin metabolite (6-acetylmorphine, 6-AM) assay to reliably detect heroin use. Specimens (N = 525) from a criminal justice drug-testing program were screened with this assay (cutoff concentration = 10 ng/mL 6-AM) and any positive samples were confirmed by gas chromatographic-mass spectrometric analysis (lower reporting limit for 6-AM = 5 ng/mL). The confirmation rate for the enzyme immunoassay (EIA) was 98% (517/525). Specimens contained 6-AM at concentrations ranging from 5 to 16,923 ng/mL (mean = 1251; median = 317). All confirmed specimens also contained morphine (range: 8-222,427 ng/mL; mean = 11,203 ; median = 4134). When challenged with standard drug solutions, the EIA correctly identified drug-free urine and produced positive results (lowest concentration, in ng/mL, that produced a positive result) with morphine at 10,000; oxycodone at 61,000; codeine at 60,000; hydromorphone at 10,000; hydrocodone at 60,000, 6-AM at 10, and pentazocine at 35,000 ng/mL. The Cedia heroin metabolite (6-AM) assay produced a high confirmation rate when challenged with urine specimens and therefore should be a useful tool in forensic toxicology. Potential users should be aware that high concentrations of other opioids (e.g., morphine, oxycodone) and structurally related compounds (e.g., pentazocine) may produce positive results.

Criminal Law↗

Direct analysis of opiates in urine by liquid chromatography-tandem mass spectrometry.

A method for the direct analysis of 10 opiate compounds in urine was developed using liquid chromatography-mass spectrometry-mass spectrometry (LC-MS-MS) with electrospray ionization interface (ESI). Opiates included were morphine-3-P-glucuronide, morphine-6--glucuronide, morphine, oxymorphone, hydromorphone, norcodeine, codeine, oxycodone, 6-monoacetylmorphine (6MAM), and hydrocodone. Urine samples were prepared by centrifugation to remove large particles and direct injection into the LC-MS-MS. Separation and detection of all compounds was accomplished within 6 min. Linearity was established for all opiates except 6MAM from 50 ng/mL to 10,000 ng/mL; 6MAM from 0.25 ng/mL to 50 ng/mL with all correlation coefficients (r) > 0.99. Interrun precision (%CV) ranged from 1.1% to 16.7%, and intrarun precision ranged from 1.3% to 16.3%. Accuracy (% bias) ranged from -7.3% to 13.6% and -8.5% to 11.8 for inter- and intrarun, respectively. Eighty-nine urine samples previously analyzed by gas chromatography-MS were re-analyzed by the LC-MS-MS method. The qualitative results found an 88% agreement for negative samples between the two methods and 94% for positive samples. The LC-MS-MS method identified 19 samples with additional opiates in the positive samples. Overall, the direct injection LC-MS-MS method performed well and permitted the rapid analysis of urine samples for several opiates simultaneously without extensive sample preparation.

Chromatography, High Pressure Liquid↗

Evidence of morphine metabolism to hydromorphone in pain patients chronically treated with morphine.

Minor metabolic pathways in human subjects have been shown to exist for the conversion of codeine to hydrocodone but have not been reported for the metabolic conversion of morphine to hydromorphone. In this study, urine specimens were collected in an out-patient setting from 13 pain patients who were chronically treated with morphine and other opioids (methadone, oxycodone, and fentanyl). The chronic pain patients were chosen for study because they were treated with high-dose morphine and had no personal or family history of addiction. Results of the initial evaluation and follow up of these patients with random urine tests did not indicate opioid misuse. The specimens were analyzed by GC-MS for the presence of hydromorphone. The reporting limit for hydromorphone was 100 ng/mL. Ten of the 13 morphine-treated patients excreted hydromorphone in minor amounts ranging 120 to 1400 ng/mL. Concurrent morphine concentrations were exceedingly high in these 10 patients and frequently exceeded the upper limit of linearity (> 10,000 ng/mL) of the assay. The ratio of hydromorphone to morphine ranged from 0.015 to 0.024. Morphine concentrations in the three patients in which hydromorphone was not detected tended to be lower than those observed in other patients. For comparison, one additional patient was included in the study, who was prescribed both morphine and hydromorphone. Concentrations of hydromorphone in this patient were in the range of 3400-13,000 ng/mL, while concurrent morphine concentrations were in the range of 3200-6600 ng/mL. These data are highly suggestive that hydromorphone can be produced as a minor metabolite of morphine in humans. Although additional studies in more restricted settings are needed, it is recommended that interpretation of low urinary concentrations of hydromorphone in combination with high concentrations of morphine in morphine-treated pain patients should not be considered as conclusive evidence of hydromorphone misuse.

Adult↗

A comparative evaluation of the instant-view 5-panel test card with OnTrak TesTcup Pro 5: comparison with gas chromatography-mass spectrometry.

This study compared the ability of two on-site testing devices, Instant-View Test Card and OnTrak TesTcup Pro 5, to discriminate negative from positive urine samples for cannabinoids, cocaine metabolite, opiates, amphetamines, and benzodiazepines. The on-site devices were evaluated in a precision study with fortified urine samples and in a clinical study with samples submitted for forensic urine drug testing. For precision, seven stocks were prepared per device. Each stock had all five analytes added in a random fashion at 0, 25, 50, 75, 125, 150, or 175% of cutoff. Ten aliquots per stock were assigned random numbers and analyzed by two individuals. The respective accuracies (defined as "% below cutoff samples that were negative + % above cutoff samples that were positive") for Instant-View Test Card and TesTcup were 74.3 and 87.1 for amphetamines; 82.1 and 90.7 for benzoylecgonine; 88.6 and 90.7 for benzodiazepines; 83.6 and 94.3 for morphine; 82.1 and 87.9 for cannabinoids; and 82.1 and 90.1% overall. In contrast to the on-site testing devices, instrumental testing with OnLine reagents had perfect precision. For the clinical study, submitted samples that had reached their disposal date were rescreened for the five drug groups. Fifty that had absorbance changes near the negative control for all five drug groups were selected as "negatives"; 240 samples with positive or multi-positive results (some between the 75% control and cutoff) and confirmed by GC-MS were chosen as "positives" (at least 45 per drug group). The non-positive drug groups in these samples added 150 additional presumptively negatives per drug group. Samples were assigned random numbers, and two individuals tested each sample. The respective accuracies in respect to GC-MS results for Instant-View Test Card and TesTcup were 95.8 and 91.7 for amphetamines; 100 and 100 for benzoylecgonine; 96.7 and 96.5 for benzodiazepines; 98.8 and 99.2 for opiates; 94.4 and 95.0 for cannabinoids; and 97.1 and 96.5% overall. The clinical study revealed that the Instant-View Test Card had low cross-reactivity (i.e., false negatives) for samples with amphetamine only and oxycodone. TesTcup had low cross-reactivity for samples with amphetamine only and hydrocodone and/or hydromorphone; it also had more cross-reactivity towards (i.e., false positives) sympathomimetic amines. In summary, the Instant-View Test Card was less precise than the TesTcup at or near the cutoff; with clinical samples, however, the percent accuracies of the two devices were similar.

Forensic Medicine↗

Sameridine is safe and effective for spinal anesthesia: a comparative dose-ranging study with lidocaine for inguinal hernia repair.

UNLABELLED: Sameridine is a new compound with local anesthetic and analgesic properties when injected intrathecally. We studied the anesthetic and analgesic efficacy of three doses of isobaric sameridine (15, 20, and 23 mg) compared with 100 mg of hyperbaric lidocaine for spinal anesthesia in 140 healthy male patients undergoing inguinal hernia repair. Patients received spinal anesthesia with 4 mL of the study drug injected at the L2-3 or L3-4 interspace in the lateral decubitus position. All three doses of sameridine provided spinal anesthesia similar to lidocaine, with a slightly longer time to reach peak block height. The failure rate was highest in the 15-mg sameridine group, and accrual was discontinued in that group after 35 patients. The duration of blockade was shorter with lidocaine, but the time to voiding and ambulation was similar in all groups. Patients receiving sameridine were less likely to request morphine for postoperative analgesia and were less likely to request any analgesia in the first 4 h after injection of the drug. Use of oral analgesics (hydrocodone and acetaminophen) was similar in all groups after the first 4 h of the 24-h observation. We conclude that, in the three doses studied, sameridine provided spinal anesthesia similar to lidocaine, but with residual analgesia after drug injection that reduced the need for systemic analgesics in the first 4 h postoperatively. IMPLICATIONS: In this clinical trial, we show the potential efficacy of a class of drugs that can produce both spinal anesthesia and postoperative analgesia when used for hernia repair.