Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

A high-throughput screen for porphyrin metal chelatases: application to the directed evolution of ferrochelatases for metalloporphyrin biosynthesis.

Porphyrins are of particular interest in a variety of applications ranging from biocatalysis and chemical synthesis to biosensor and electronic technologies as well as cancer treatment. Recently, we have developed a versatile system for the high-level production of porphyrins in engineered E. coli cells with the aim of diversifying substitution patterns and accessing porphyrin systems not readily available through chemical synthesis. However, this approach failed to produce significant amounts of the metalloporphyrin in vivo from overproduced protoporphyrin due to insufficient metal insertion. Therefore, we systematically assessed the activity of the B. subtilis ferrochelatase in vivo and in vitro. A true high-throughput-screening approach based on catalytic in vivo ferrochelatase activity was developed by using fluorescence-activated cell sorting (FACS). This assay was used to screen a library of 2.4 x 10(6) ferrochelatase mutants expressed in protoporphyrin-overproducing recombinant E. coli cells. Several selected protein variants were purified, and their improved catalytic activity was confirmed in vitro. In addition to ferrochelatase activity, metal transport into E. coli was identified as another limitation for in vivo heme overproduction. Overexpression of the metal transporter zupT as part of the assembled pathway increased the overall metalloporphyrin production twofold. This report represents the most exhaustive in vitro evolution study of a ferrochelatase and demonstrates the effectiveness of our novel high-throughput-screening system for directed evolution of ferrochelatases based on their catalytic activity.

Ferrochelatase↗

High throughput screening assay for negative single stranded RNA virus polymerase inhibitors.

The Paramyxoviridae form a large family of viruses containing many human and veterinary pathogens for which a need for antiviral treatment is emphasized, particularly following the recent emergence of new viruses. The viral RNA-dependent RNA polymerase constitutes an obvious target for antiviral compounds. An in vitro assay was developed that allows high throughput screening of compounds potentially inhibiting the Sendai virus RNA-dependent RNA polymerase. Screening relies on the detection of the Photinus pyralis luciferase produced in a transcription/translation coupled assay using a mini-replicon virus. It contains an internal control for possible adverse effects of the tested compounds on translation or on luciferase activity. It is estimated that the mini-replicon template produced in one fertilized egg is sufficient to run 5000-10,000 reactions. This assay constitutes a simple, sensitive and easily automated method to perform high throughput screening of Paramyxoviridae RNA-dependent RNA polymerase inhibitors.

Animals↗

A generic particle-based nonradioactive homogeneous multiplex method for high-throughput screening using microvolume fluorimetry.

We have developed a novel fluorescence-based homogeneous binding assay for high-throughput screening of chemical compounds. In this assay, a Cy5- or Cy5.5-labeled ligand binds to receptor immobilized on a particle, either a bead or a cell. The resulting localized signal can be detected by a modified microvolume fluorimeter (MVF). When a molecule which competes with the labeled ligand is present, the localized fluorescence on cells or beads is reduced. Image processing software enumerates events and analyzes fluorescence intensity. We describe MVF assays for the IL-1 and IL-5 receptors. Using synthetic peptides with a range of affinities for the IL-1 receptor, we obtained IC(50) data consistent with those determined by radioligand binding assays. Because the image processing software can discriminate among events with different diameters, we were able to develop a multiplex assay, in which the IL-1R and IL-5R assays were carried out in the same well with each receptor immobilized on a different size of bead. IC(50) values generated in the multiplex assay for ligands specific to each receptor were comparable to those determined independently. Finally, similar IC(50) values were obtained in a 16-microl volume in an 864-well plate. This homogeneous, nonradioactive, miniaturizable, and multiplex-capable assay holds much promise for screening of combinatorial libraries and compound collections.

Animals↗

An empirical process for the design of high-throughput screening deck filters.

A process for objective identification and filtering of undesirable compounds that contribute to high-throughput screening (HTS) deck promiscuity is described. Two methods of mapping hit promiscuity have been developed linking SMARTS-based structural queries with historical primary HTS data. The first compares an expected assay hit rate to actual hit rates. The second examines the propensity of an individual compound to hit multiple assays. Statistical evaluation of the data indicates a correlation between the resultant functional group filters and compound promiscuity. These data corroborate a number of commonly applied filters as well as producing some unexpected results. Application of these models to HTS collection triage reduced the number of in-house compounds considered for screening by 12%. The implications of these findings are further discussed in the context of the HTS screening set and combinatorial library design as well as compound acquisition.

Drug Design↗

Automated high throughput screening for serine kinase inhibitors using a LEADseeker scintillation proximity assay in the 1536-well format.

High-throughput screening in the 1536-well format has been largely restricted to solution-based and cell-based screens. In this article, we show the feasibility of a completely automated, robust scintillation proximity assay in the 1536-well format that is suitable to identify inhibitors for a serine/threonine kinase from a compound library. The introduction of [(33)P]phosphate into a biotinylated peptide substrate mirrors the activity of the kinase. The peptide is immobilized on streptavidin-coated LEADseeker imaging beads and [(33)P]phosphate incorporation is detected with the LEADseeker imaging system of Amersham Pharmacia Biotech. To improve the liquid handling procedures for imaging bead suspensions in the low microliter range, we developed a novel trough with an integrated stirring function. A comparison of the 1536-well assay to a 384-well assay revealed a comparable assay quality with Z' factors of about 0.7 for the 384-well format and 0.6 for the 1536-well format. In an automated screen of a random compound collection, 94.4% of the inhibitory compounds could be identified with both assay formats. Dose-response curves were performed for a selection of identified kinase inhibitors and revealed similar IC(50) values for both assay formats.

Automation↗

A neutravidin-based assay for reverse transcriptase suitable for high throughput screening of retroviral activity.

A non-isotopic neutravidin-based reverse transcriptase (RT) assay adapted for high throughput screening of HIV activity is described. Using a 96-well microtitre plate, HIV particles are lysed and the RT enzyme released into a reaction mixture containing poly(A) RNA, biotinylated oligo d(T) and fluorescein-labelled dUTP (FI-dUTP). With poly(A) as a template and oligo d(T) as primer, the viron RT incorporates FI-dUTP into an elongating DNA strand. The resulting product is captured on a neutravidin-coated 96-well plate and the unincorporated nucleotides removed by a series of washing steps. A simple ELISA is subsequently performed using a monoclonal antifluorescein antibody conjugated to alkaline phosphatase. Quantification of RT activity is facilitated by a colorimetric readout. The assay was validated in the context of a diagnostic HIV-1 phenotyping assay. Using supernatants from HIV-1 infected lymphocyte cultures the assay was shown to be as sensitive as a radioactive assay and the RT activity correlated well with levels of cell-associated HIVp24. Importantly, even minor reductions of RT activity by virus variants with reduced fitness could be distinguished.

Avidin↗

High-throughput screening for human collagenase 1 inhibitors.

AIM: To establish a high-throughput method for inhibitor screening using a recombinant collagenase catalytic domain. METHODS: Human collagenase 1 catalytic domain protein was expressed in E coli and used for screening a set of 2720 compounds in a high-throughput fashion. RESULTS: The screening was accomplished within 2 h and 10 min with consumption of each compound at 4 micrograms. Sixty-six compounds were identified with > 60% inhibitory activity at 20 mg/L, among which 44 compounds were confirmed by subsequent testing at multiple concentrations. The most potent compound showed an IC50 at 4.3 mumol/L, and there were total 15 compounds with IC50 less than 20 mumol/L. CONCLUSION: The high-throughput method using the recombinant collagenase is fast, effective and practical in identifying inhibitors.

Collagenases↗

A high-throughput screen for identifying transmembrane pore-forming peptides.

We have developed a visual microwell plate assay for rapid, high-throughput screening for membrane-disrupting molecules such as de novo designed pore formers, antibiotic peptides, bacterial toxins, and lipases. The detectability is based on the strong fluorescence emission of the lanthanide metal terbium(III) (Tb(3+)) when it interacts with the aromatic chelator dipicolinic acid (DPA). While Tb(3+) is not strongly fluorescent alone, the binary complex emits bright green fluorescence when irradiated with uv light. For the microwell plate assay, we prepared unilamellar phospholipid vesicles that had either Tb(3+) or DPA entrapped and the opposite molecule in the external solution. Disruption of the membranes allows the Tb(3+)/DPA complex to form, giving rise to a visibly fluorescent solution. In plates with 20-microl wells, the lower limit of visual detectability of the Tb(3+)/DPA complex in solution was about 2.5 microM. The lower limit of detectability using vesicles with entrapped Tb(3+) or DPA was about 50 microM phospholipid. We show that the membrane-disrupting effect of as little as 0.25 microM or 5 pmol of the pore-forming, antibiotic peptide alamethicin can be detected visually with this system. This sensitive, high-throughput assay is readily automatable and makes possible the visual screening of combinatorial peptide libraries for members that permeabilize lipid bilayer membranes.

Alamethicin↗

A new surface plasmon resonance sensor for high-throughput screening applications.

We report a new high-throughput surface plasmon resonance (SPR) sensor based on combination of SPR imaging with polarization contrast and a spatially patterned multilayer SPR structure. We demonstrate that this approach offers numerous advantageous features including high-contrast SPR images suitable for automated computer analysis, minimum crosstalk between neighboring sensing channels and inherent compensation for light level fluctuations. Applications of a laboratory prototype of the high-throughput SPR sensor with 108 sensing channels for refractometry and biosensing are described. In refractometric experiments, the noise-limited refractive index resolution of the system has been established to be 3 x 10(-6) refractive index unit (RIU). Experimental data on detection of human choriogonadotropin (hCG) suggest that in conjunction with monoclonal antibodies against hCG, the reported SPR imaging sensor is capable of detecting hCG at concentrations lower than 500 ng/ml.

Biosensing Techniques↗

Enzyme fragment complementation: a flexible high throughput screening assay technology.

High-affinity complementation of a small fragment of beta-galactosidase to an inactive deletion mutant of the enzyme forms a stable heteromeric enzyme complex capable of hydrolyzing substrates to produce either chemiluminescent or fluorescent signals. This review describes a series of screening assays in which the small beta-galactosidase fragment, Enzyme Donor or ProLabel, is either chemically conjugated or recombinantly fused to small molecules or proteins, respectively. Chemical conjugation forms the basis of several HitHunter HTS assays in which competitive displacement of the ProLabel conjugate from either a binding protein (receptor or antibody) is induced by the analyte in question. In this manner, a calibration curve is generated, to measure cellular analytes including 3',5'-cyclic AMP. Changes in this second messenger, occurring due to G protein-coupled receptor (GPCR) activation, can thus be easily measured in a homogeneous assay. Similar assays have been developed for tyrosine kinases, serine threonine kinases, nuclear hormone receptors, and proteases. A second form of assay technology involves measurement of cellular protein expression, in which the protein is fused to ProLabel. Analysis can be undertaken in crude cell lysates, or with intact cells, using beta-galactosidase complementation in a microtiter plate. This homogeneous technology is highly sensitive and has been developed to measure protein expression changes occurring in response to pathway activation by targets such as GPCRs, tyrosine kinase receptors, and proteases. In summary, the DiscoveRx technology using beta-galactosidase complementation provides a robust and flexible assay technology for use in cell-free and cell-based HTS.

Animals↗

Gene expression analysis for high throughput screening applications.

To meet growing needs for high throughput gene expression profiling, we established a new automated high throughput TaqMan RT-PCR method for quantitative mRNA expression analysis. In this method, the Allegro( trade mark ) (Zymark) system conducts all sample tracking and liquid handling steps, and ABI PRISM 7900 HT (Applied Biosystems) is used to conduct real-time determination of the C(t) value when amplification of PCR products is first detected and accumulation of inhibitory PCR products is unlikely to occur. The ABI PRISM 7900 HT Sequence Detection System features a real-time PCR instrument with 384-well-plate compatibility and robotic loading, and continuous wavelength detection, which enables the use of multiple fluorophores in a single reaction. The Allegro System offers an assembly line approach with a modular design that allows reconfiguration of the components to accommodate variations in the assay flow. In the present study, we have established and validated a new automated High Throughput (HT) TaqMan RT-PCR- based method for quantitative mRNA expression analysis. The data demonstrate that HT-Taqman PCR is a powerful tool that can be used for measuring low concentrations of mRNA, and is highly accurate, reproducible, and amenable to high throughput analysis. Results suggest that HT-TaqMan is a reliable method for the quantification of low-expression genes and a powerful tool with HT capability for target identification/validation, structure-activity relationship (SAR) study, compound selection for efficacy studies, and biomarker identification in drug discovery and development.

Drug Design↗

A simple technique for high-throughput screening of drugs that modulate normal and psoriasis-like differentiation in cultured human keratinocytes.

Established treatments for psoriasis act ei-ther on hyperproliferation, inflammation, aberrant epidermal differentiation or a combination of these aspects of the disease. Potential new drugs for treatment of psoriasis or other disorders with abnormalities in epidermal differentiation can be identified by high-throughput screening of large compound libraries using surrogate markers for the disease. Here we describe a screening model to detect pharmacologically active drugs in two keratinocyte-based, 96-well culture models that use expression of cytokeratin 10 (CK10) and skin-derived antileucoprotease (SKALP)/elafin as markers for normal and psoriatic differentiation, respectively, and allow multiple parameters to be determined from a single well. In this model we tested a number of compounds in a pharmacological range from 10(-7) to 10(-5) M, including known antipsoriatic drugs, and experimental drugs that are potentially useful in the treatment of psoriasis. All-trans-retinoic acid, dithranol and the p38 mitogen-activated protein (MAP) kinase inhibitor SB220025 displayed a strong inhibitory effect on SKALP expression while cyclosporin A, dexamethasone, the vitamin D(3) derivative calcipotriol and the p38 MAP kinase inhibitor SB203580 showed only moderate inhibition. Methotrexate and dimethylfumarate did not affect the expression of SKALP. With respect to CK10 expression, all-trans-retinoic acid, calcipotriol, SB203580 and SB220025 exhibited strong inhibition while dithranol showed only moderate suppression of this normal differentiation marker. Expression levels of CK10 were not significantly affected by dexamethasone, methotrexate, cyclosporin A or dimethylfumarate. This model system parallels most, but not all, findings on the in vitro effect of known antipsoriatic drugs on keratinocytes. In addition, the model identifies p38 MAP kinase inhibitors as potent suppressors of differentiation-associated gene expression. Although further delineation and validation of this model is required, we conclude that the system is amenable to down-scaling and application as a high-throughput screen for differentiation-modifying compounds.

Anthralin↗

NanoStore: a concept for logistical improvements of compound handling in high-throughput screening.

Small molecule screening, the systematic encounter of biology space with chemical space, has provoked the emergence of a whole industry that recreates itself by constant iterative improvements to this process. The authors describe an approach to tackle the problem for one of the most time-consuming steps in the execution of a screening campaign, namely, the reformatting of high-throughput screening test compounds from master plates to daughter assay plates used in the execution of the screen. Through an engineered storage procedure, they prepare plates ahead of the screening process with the respective compounds in a ready-to-use format. They show the biological inertness of the method and how it facilitates efficient recovery of compound activity. This uncoupling of normally interconnected processes provides time and compound savings, avoids repeated freeze-thaw cycles of compound solutions, and removes the problems associated with the DMSO sensitivity of certain assays types.

Automation↗

Utility of large-scale transiently transfected cells for cell-based high-throughput screens to identify transient receptor potential channel A1 (TRPA1) antagonists.

Despite increasing use of cell-based assays in high-throughput screening (HTS) and lead optimization, one challenge is the adequate supply of high-quality cells expressing the target of interest. To this end, cell lines stably expressing targets are often established, maintained, and scaled up by cell culture. These steps require large investments of time and resources. Moreover, significant variability invariably occurs in cell yield, viability, expression levels, and target activities. In particular, stable expression of targets such as transient receptor potential A1 (TRPA1) causes toxicity, cell line degeneration, and loss of functional activity. Therefore, in an effort to identify TRPA1 antagonists, the authors used large-scale transiently transfected (LSTT) cells, enabling rapid establishment of assays suitable for HTS. LSTT cells, which could- be stored frozen for a long period of time (e.g., at least 42 weeks), retained TRPA1 protein expression and could be easily revived to produce robust and consistent signals in calcium influx and electrophysiological assays. Using cells from a single transfection, a chemical library of 700,000 compounds was screened, and TRPA1 antagonists were identified. The use of LSTT circumvented issues associated with stable TRPA1 expression, increased flexibility and consistency, and greatly reduced labor and cost. This approach will also be applicable to other pharmaceutical targets.

Calcium↗

Development of combinatorial chemistry methods for coatings: high-throughput screening of abrasion resistance of coatings libraries.

Design, validation, and implementation of an optical spectroscopic system for high-throughput analysis of combinatorially developed protective organic coatings are reported. Our approach replaces labor-intensive coating evaluation steps with an automated system that rapidly analyzes 8 x 6 arrays of coating elements that are discretely deposited on a single plastic substrate. Each coating element of the library is 10 mm in diameter and 2-5 microm thick. Performance of coatings is evaluated with respect to their resistance to wear abrasion because this parameter is one of the primary considerations in end-use applications. Upon testing, the coating materials undergo changes that are impossible to quantitatively predict using existing knowledge. Coatings are abraded using industry-accepted abrasion test methods at a single or multiple abrasion conditions followed by the high-throughput analysis of abrasion-induced light scatter. The developed automated system is optimized for the analysis of diffusively scattered light that corresponds to 0-30% haze. System precision of 0.1-2.5% relative standard deviation provides capability for the reliable ranking of coatings performance. Although the system was implemented for high-throughput screening of combinatorially developed organic protective coatings for automotive applications, it can be applied for a variety of other applications for which materials ranking can be achieved using optical spectroscopic tools.

Journal Article↗

High-throughput screening for isolation of enhanced green fluorescent protein expressing transformants of filamentous fungus using an image analyzer.

High-throughput screening of enhanced green fluorescent protein (EGFP) gene-trap transformants of filamentous fungus was achieved for the first time using an image analyzer to measure their fluorescent intensity. For quantitative analysis of EGFP fluorescent intensity per unit cell mass, we developed a method for measurement of cell mass using the fluorescent dye SP-Dil. This method offers an effective and convenient tool for screening transformants expressing fluorescent protein as a reporter, and for quantitative analysis of fungal cell mass at jig levels.

Journal Article↗

Design and use of electrochemical sensors in enantioselective high throughput screening of drugs. A minireview.

The importance of reliable detection systems for enantiomeric assays increases with the necessity of high throughput screening analysis of raw materials for the pharmaceutical industry. The utilization of electrochemical sensors in enantioselective analysis is an accurate and precise alternative to chromatographic techniques. The reliability of the response characteristics as well as of the analytical information obtained by using electrochemical sensors is strictly correlated with the design of the sensors. The designs evaluated for sensors have been based on PVC, imprinting polymers and carbon paste matrices. Among these, carbon paste sensors have been the most reliable and have been utilized for the construction of potentiometric, enantioselective membrane electrodes as well as for amperometric biosensors, and immunosensors. There are two ways to use the electrochemical sensors in enantioselective screening analysis: selective binding and catalyst selectivity. A molecule with a special chemical architecture is required for selective binding: a lock for a key. The high reliability of analytical information obtained using these sensors has made possible the automation of potentiometric and amperometric techniques by integration of enantioselective sensors as detectors in flow injection analysis and sequential injection analysis techniques.

Animals↗

[Advancement of patch-clamp technique and its application in drug high-throughput screening].

The patch-clamp technique, a dominant technique in cellular electrophysiology, is always being regarded as the gold standard for ion channel research. Application of the patch-clamp technique can demonstrate the existences of ion channels and provide valuable information for ion channels, including their electrophysiological properties, molecular structures and the mechanism of drug action. Genomics and proteomics research has showed that the development of drugs for ion channel target would be very promising in future. In recent years, numerous improvements have been achieved, which will facilitate the application of patch clamp technique in drug high-throughput screening. These techniques will break through the bottleneck in the development of drugs aiming at ion channels. New advancements in patch-clamp technique and application in drug high-throughput screening are reviewed in the paper.

Animals↗