Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “HARDNESS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion.

STATEMENT OF THE PROBLEM: In selecting a disinfectant for dental prostheses, compatibility between the disinfectant and the type of denture base material must be considered to avoid adverse effects on the hardness of the acrylic resin. PURPOSE: This study investigated the hardness of 2 denture base resins after disinfection and long-term water immersion. MATERIAL AND METHODS: Thirty-two disk-shaped specimens (13 mm in diameter and 8 mm thick) were fabricated from each resin (Lucitone 550 and QC-20), polished, stored in water at 37 degrees C for 48 hours, and submitted to hardness tests (Vickers hardness number [VHN]) before disinfection. Disinfection methods included scrubbing with 4% chlorhexidine gluconate for 1 minute, immersion for 10 minutes in 1 of the tested disinfectant solutions (n=8) (3.78% sodium perborate, 4% chlorhexidine gluconate, or 1% sodium hypochorite), and immersion in water for 3 minutes. The disinfection procedures were repeated 4 times, and 12 hardness measurements were made on each specimen. Control specimens (not disinfected) were stored in water for 56 minutes. Hardness tests (VHN) were also performed after 15, 30, 60, 90, and 120 days of storage in water. Statistical analyses of data were conducted with a repeated measures 3-way analysis of variance (ANOVA) and Tukey post-hoc test (alpha=.05). RESULTS: Mean values +/- SD for Lucitone 550 (16.52 +/- 0.94 VHN) and QC-20 (9.61 +/- 0.62 VHN) demonstrated a significant (P <.05) decrease in hardness after disinfection, regardless of material and disinfectant solutions used (Lucitone 550: 15.25 +/- 0.74; QC-20: 8.09 +/- 0.39). However, this effect was reversed after 15 days of storage in water. Both materials exhibited a continuous increase (P <.05) in hardness values for up to 60 days of water storage, after which no significant change was observed. CONCLUSION: Within the limitations of this in vitro study, QC-20 and Lucitone 550 specimens exhibited significantly lower hardness values after disinfection regardless of the disinfectant solution used.

Acrylic Resins↗

Effect of exposure intensity and post-cure temperature storage on hardness of contemporary photo-activated composites.

OBJECTIVES: The effect of variation in post-exposure storage temperature (18 vs. 37 degrees C) and light intensity (200 vs. 500mW/cm(2)) on micro-hardness of seven light-activated resin composite materials, cured with a Prismetics Mk II (Dentsply) light activation unit, were studied. METHODS: Hardness values at the upper and lower surfaces of 2mm thick disc shaped specimens of seven light-cured resin composite materials (Herculite XRV and Prodigy/Kerr, Z100 and Silux Plus/3M, TPH/Dentsply, Pertac-Hybrid/Espe, and Charisma/Kulzer), which had been stored dry, were determined 24h after irradiation with a Prismetics Mk II (Dentsply) light activation unit. RESULTS: Hardness values varied with product, surface, storage temperature, and curing light intensity. In no case did the hardness at the lower surface equal that of the upper surface, and the combination of 500mW/cm(2) intensity and 37 degrees C storage produced the best hardness results at the lower surface. CONCLUSIONS: Material composition had a significant influence on surface hardness. Only one of the seven products (TPH) produced a mean hardness values at the lower surface >80% of the maximum mean upper surface hardness obtained for the corresponding product at 500mW/cm(2) intensity/37 degrees C storage temperature when subjected to all four test regimes. Despite optimum post-cure storage conditions, 200mW/cm(2) intensity curing for 40s will not produce acceptable hardness at the lower surface of 2mm increments of the majority of products tested.

Analysis of Variance↗

Near-infrared spectroscopy as a nondestructive alternative to conventional tablet hardness testing.

PURPOSE: Near-infrared reflectance spectroscopy (NIRS) was used to evaluate and quantify the effect of compression force on the NIR spectra of tablets. METHODS: Flat, white tablets with no orientation (scoring, etc.) were manufactured on a Stokes Rotary Tablet Press. NIRS was used to predict tablet hardness on the following four formulations and one placebo matrix: hydrochlorothiazide (HCTZ) 15% and 20% in a placebo matrix (microcrystalline cellulose and magnesium stearate), and chlorpheniramine maleate (CTM) 2% and 6% in a placebo matrix. Five or six levels of tablet hardness from 2 to 12 kg were used for each formulation. Laboratory hardness data was compared to NIR reflectance data using a NIRSystems Rapid Content Analyzer. Multiple linear regression and partial least squares regression techniques were used to determine the relationship between tablet hardness and NIRS spectra. RESULTS: An increase in tablet hardness produced an upward shift (increase in absorbance) in the NIRS spectra. A series of equations was developed by calibrating tablet hardness data against NIR reflectance response for each formulation. The results of NIRS hardness prediction were at least as precise as the laboratory hardness test (SE = 0.32). CONCLUSIONS: A NIRS method is presented which has the potential as an alternative to conventional hardness testing of tablets.

Chlorpheniramine↗

Pilot study of the relationship between the hardness and abrasion resistance of two base metal alloys used for metal-ceramic restorations.

STATEMENT OF PROBLEM: Base metal alloys present high values of strength and hardness, which have been associated with the greater abrasion resistance and polishing of metal-ceramic restorations. However, surface hardness has been shown to be a poor indicator of abrasion resistance. PURPOSE: The study aimed to compare the hardness and abrasion resistance of Ni-Cr alloys and determine whether there is a correlation between these 2 properties. MATERIAL AND METHODS: Two Ni-Cr alloys for metal-ceramic restorations with different hardness values were subjected to the following procedures: (1) initial measurement of Vickers hardness, (2) a series of abrasion cycles, (3) measurement of mass loss after each cycle, and (4) Vickers hardness measurements after each cycle. RESULTS: For each alloy, linear regression revealed a negative correlation between hardness and reduction in mass. The higher hardness of alloy A was associated with higher mass loss during abrasion when compared with alloy B. CONCLUSION: There was no significant correlation between hardness and mass loss for either alloy.

Chromium Alloys↗

[Studies on oral sensation in patients with implant denture. 4. Ability of hardness discrimination].

The ability of hardness discrimination in 11 implant denture wearers was compared with those in 10 bridge wearers and 11 normal dentate subjects. The hardness discrimination was tested using silicone rubber blocks having rubber hardness that ranged at intervals of 10 degrees from 30 degrees to 70 degrees. Using a rubber block with rubber hardness of 50 degrees as a standard, the ability of discriminating rubber blocks of different hardness was examined. All the three groups examined had excellent ability of discriminating the rubber blocks of rubber hardness of 30 degrees and 70 degrees from the standard block. The ability to discriminate the rubber block of rubber hardness of 40 degrees from the standard block was only slightly lower than but almost the same as the ability of discriminating the hardness of 30 degrees and 70 degrees in all the three groups. However, the ability of discriminating the rubber block of rubber hardness of 60 degrees from the standard block was significantly lower in the implant denture wearers, compared to the normal dentate subjects and bridge wearers.

Dental Implants↗

Studies on segmented polyetherurethane for biomedical application: effects of composition and hard-segment content on biocompatibility.

Segmented polyetherurethane (SPEU) materials based on polytetramethylene oxide (PTMO, Mw 1000 and 2000) with various hard-segment contents were synthesized and their biocompatibilities studied via different tests. The static contact angle data reveal that the higher hard-segment-content SPEU material possesses a lower contact angle, implying that the surface of the higher hard-segment-content SPEU is more hydrophilic than its low hard-segment-content SPEU counterpart. The catalyst- and additive-free PTMO-based SPEU materials in this study possess neither a hemolytic nor a cytotoxic response that could be considered non toxic for biomedical applications. By using L-929 cell lines, a cell-seeding test indicated that the higher hard-segment-content SPEU material possesses quicker cell attachment and proliferation behaviors. In vitro platelet adhesion tests indicated that the lower hard-segment-content SPEU possesses less platelet adhesion than the high hard-segment-content SPEU material. Both ex vivo canine artery-artery (A-A) and arterio-venous (A-V) shunting tests revealed that the extent of platelet adhesion reaction is less for lower hard-segment content SPEU. In addition, the blood compatibility of SPEU material synthesized from PTMO 1000 excels over PTMO 2000 SPEU material by near the same levels as the hard-segment-content SPEU.

Animals↗

An immunohistochemical study on hard tissue formation in a subcutaneously transplanted rat molar.

While dental pulp undergoes calcification following tooth replantation or transplantation, we actually know little about these mechanisms. We therefore conducted histological and immunohistochemical evaluations of mineralized tissue that formed in the pulp of rat maxillary molar transplanted into abdominal subcutaneous tissue. One, 2, 3, and 4 weeks post-transplantation, the teeth were investigated immunohistochemically using antibodies to osteocalcin (OCN), osteopontin (OPN), bone sialoprotein (BSP), dentin sialoprotein (DSP), and tissue non-specific alkaline phosphatase (TNAP). In the 1st week after transplantation, cell-rich hard tissue was formed at the root apex. At 2 weeks, formations of hard tissue, with few cells in the root canals and bone-like tissue in the coronal pulp chamber, were noted. After 3 and 4 weeks, the amounts of these hard tissues were increased. The immunolocalization of OCN, OPN, and BSP was seen strongly in coronal and apical hard tissues, but weakly in the root hard tissue. Conversely, DSP localized in the root hard tissue, but not in other newly formed hard tissues. At 1 week, TNAP localized along the periphery of the apical hard tissue and the lower surfaces of root predentin. These results demonstrate that the newly formed hard tissues in the pulp cavity of subcutaneously transplanted molars could be classified into three types, suggesting that these might be formed by type-specific cells.

Animals↗

Early expression of grain hardness in the developing wheat endosperm.

Seeds from near-isogenic hard and soft wheat lines were harvested at regular intervals from 5 days post-anthesis to maturity and examined for hardness using the single kernel characterisation system (SKCS). SKCS analysis revealed that hard and soft lines could be distinguished from 15 days post-anthesis (dpa). This trend continued until maturity where the difference between the hard and soft lines was most marked. SKCS could not be applied to the small 5- and 10-dpa wheat kernels. Fresh developing endosperm material was examined using light microscopy and no visible differences between the cultivars were detected. When air-dried material was examined using scanning electron microscopy (SEM) differences between soft and hard lines were visible from as early as 5 dpa. Accumulation of puroindoline a and puroindoline b was investigated in developing seeds using both Western blotting and ELISA. Low levels of puroindoline a could be detected in the soft cultivar from 10 dpa, reaching a maximum at 32 dpa. In the hard cultivar, puroindoline a levels were negligible throughout grain development. Puroindoline b accumulates in both the soft and hard cultivars from 15 dpa, but overall contents were higher in the soft cultivar. These findings indicate that endosperm hardness is expressed very early in developing grain when few starch granules and storage proteins were deposited in the endosperm cells. Further, the near-isogenic soft and hard Heron lines could be differentiated by SEM at a stage in development when the accumulation of puroindolines could not be detected by the methods used in this study.

Desiccation↗

Effects of water hardness on the physiological responses to chronic waterborne silver exposure in early life stages of rainbow trout (Oncorhynchus mykiss).

Early life stages of rainbow trout were exposed to 0, 0.1 and 1 microg/L Ag (as AgNO(3)) in very soft water (2mg/L CaCO(3)), moderately hard water (150 mg/L CaCO(3)) and hard water (400mg/L CaCO(3)) of low dissolved organic carbon concentration (0.5mg C/L) from fertilization to swim-up (64 days) under flow-through conditions, and monitored for whole embryo/larval silver accumulation, Na(+) and Cl(-) concentrations, Na(+) uptake and Na(+)K(+)-ATPase activity. The objective of the study was to investigate potential protective effects of water hardness on the physiological responses to chronic silver exposure. In the absence of silver, there was little effect of hardness on the ionoregulatory parameters studied, though higher hardness did improve survival post-hatch. At all three water hardness levels, whole embryo/larval Na(+) uptake was low and relatively constant prior to 50% hatch, but dramatically increased following 50% hatch, whereas Na(+)K(+)-ATPase activity steadily increased over development. Whole embryo/larval Na(+) and Cl(-) concentrations were low and constant prior to 50% hatch, but following 50% hatch Na(+) concentration increased, while Cl(-) concentration decreased. Following 50% hatch, exposure to 0.1 and 1 microg/L Ag resulted in a decrease in whole embryo/larval Na(+) concentration, Cl(-) concentration, Na(+) uptake and Na(+)K(+)-ATPase activity, indicating that the mechanism of chronic silver toxicity involves an ionoregulatory disturbance, and is similar to the mechanism of acute silver toxicity. An increase in water hardness reduced or eliminated the effect of silver on these parameters while enhancing survival, suggesting that the nature of the protective effect of hardness involves effects on the ionoregulatory disturbance associated with silver exposure. An increase in water hardness did not fully protect against the accumulation of silver associated with silver exposure. These results suggest that it may be possible to model chronic silver toxicity using a biotic ligand type model, and that a physiologically based model may be more appropriate because Na(+)K(+)-ATPase activity or Na(+) uptake is an endpoint for prediction rather than whole embryo or larval silver accumulation.

Animals↗

Tomographic findings of foveal hard exudates in diabetic macular edema.

PURPOSE: To report the intraretinal location of foveal hard exudates after vitrectomy to treat diabetic macular edema and to evaluate the visual outcome. METHODS: In a prospective study, the tomographic features of 11 eyes (8 patients) with diabetic macular edema were evaluated with optical coherence tomography after vitrectomy. The intraretinal location of hard exudates at the fovea (anatomic foveola) and the relationship with visual acuity were investigated. RESULTS: With optical coherence tomography, hard exudates were observed as highly reflective spots in the cross-sectional images. In six of 11 eyes (54.5%), the hard exudates were in the inner portion of the neurosensory retina; the final best-corrected visual acuity averaged 20/70 in the six eyes. In the remaining five eyes (45.5%), hard exudates were deposited not only in the neurosensory retina but also in the subretinal space. In optical coherence tomographic images, subretinal hard exudates were observed as highly reflective plaques, which were slightly elevated over the retinal pigment epithelium. The five eyes developed a serous retinal detachment at the fovea before or after vitrectomy. Subretinal hard exudates bridged the detached neurosensory retina and the retinal pigment epithelium in two eyes. The average final visual acuity level in the five eyes was 20/300. The visual outcome was significantly worse in five eyes with subretinal hard exudates than in six eyes with an intraretinal one (P <.05, Wilcoxon rank sum tests). CONCLUSIONS: If serous retinal detachment develops before or after vitrectomy for diabetic macular edema, hard exudates tend to accumulate not only in the neurosensory retina but also in the subretinal space. The visual prognosis is worse in cases of subretinal exudation.

Aged↗

Soft wheat instead of hard wheat in pelleted diets results in high starch digestibility in broiler chickens.

(1) The aim of the experiment was to re-examine variations in digestibilities of food components in 3-week-old broiler chickens fed on pelleted diets based on wheats differing in lipase activity and hardness. Fourteen wheat (Triticum aestivum) samples, each from a different cultivar, were included at 550 g/kg in 14 different diets given to male Ross broiler chicks from 7 d of age. The other main ingredients consisted of soyabean meal (353 g/kg) and rapeseed oil (55 g/kg). A 15th diet containing durum wheat (Triticum durum) was also tested. (2) Hardness of wheats (Triticum aestivum) varied between 14 (very soft) and 88 (very hard), and lipase activity of wheats varied from 1 to 13.1 (relative scale). No significant correlation was found between in vitro viscosities and other parameters such as hardness, particle size of wheat flours and lipase. Hardness was correlated with the mean particle size of wheat flours and durability of pellets. (3) Individual lipid digestibilities were negatively correlated with in vitro viscosities of wheats. (4) Individual starch digestibilities were negatively correlated with wheat hardness, particle size of wheat flour before pelleting, and pellet durability. The ratio of measured AME(N) to predicted AME(N) was also negatively correlated with wheat hardness. Simple regression calculation showed that a 100-point increase in wheat hardness resulted in a 3% decrease in the AME(N) value of diets. Multiple regression calculation showed the food/gain ratio (d 10 to d 21) to be positively related to wheat hardness and negatively related to pellet durability. (5) Wheat lipase activity was positively correlated with individual starch digestibility, which was the reverse of a result obtained in a previous experiment. Thus, wheat lipase activity did not seem consistent for predicting starch digestibility and AME(N) values. (6) Among all wheat samples, durum wheat showed the highest protein content and the lowest content of water-insoluble cell-wall. Starch digestibility of durum wheat tended to be lower than that of other wheats (0.916 vs 0.936). However, no significant difference in AME(N) was observed between the durum wheat sample and other wheats. (7) Gut morphometric data measured at d 24 did not show significant differences between dietary treatments.

Animal Feed↗

Pericranial muscle hardness in tension-type headache. A non-invasive measurement method and its clinical application.

Using a new method to measure the hardness of pericranial muscles, the role of muscle factors in tension-type headache was evaluated. In 223 normal healthy subjects, the hardness of trapezius muscles was 82 +/- 15 kPa/cm (mean +/- SD). The muscle hardness in women, 92 +/- 17 kPa/cm, was significantly greater than that in men, 74 +/- 14 kPa/cm (P < 0.01). Trapezius muscles were significantly harder than paraspinal posterior neck muscles measured at the level of the fifth cervical vertebra (71 +/- 13 kPa/cm; n = 26) but a significant correlation in muscle hardness did exist between these two muscle groups (r = 0.89, P < 0.001). Muscle hardness did not show a significant correlation with advancing age, blood pressure or subjective feeling of stiffness in the shoulder. A significant correlation was noted between the muscle hardness measured by the present method and the stiffness scores evaluated by manual palpation. In patients with tension-type headache (n = 60), the hardness of trapezius muscles, 114 +/- 24 kPa/cm (mean +/- SD), was significantly greater than that in normal subjects (P < 0.01). Twenty-six patients (43% of the total) showed significantly high values which exceeded the mean +/- 2 SD (113 kPa/cm) of the normal value, while the remaining patients (57%) constituted a high normal group. The hardness of posterior neck muscles measured in 27 patients (99 +/- 21 kPa/cm) was also significantly greater than that in normal subjects (P < 0.01). There was no significant difference in muscle hardness between episodic tension-type headache and chronic tension-type headache.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effects of water hardness on toxicological responses to chronic waterborne silver exposure in early life stages of rainbow trout (Oncorhynchus mykiss).

Rainbow trout embryos and larvae were exposed to 0, 0.1, and 1 microg/L total silver (as AgNO3) in water of three different hardnesses (soft water [2 mg/L as CaCO3], moderately hard water [150 mg/L], and hard water [400 mg/L]) in a flow-through system from fertilization to swim-up (64 d). The objective of the study was to investigate the effects of water hardness on chronic silver toxicity. In the absence of silver, elevating hardness had a positive effect on early life stage survival and development, significantly decreasing mortality and accelerating time to 50% swim-up. Following hatch, exposure to 1 microg/L Ag significantly increased mortality relative to exposure to 0 microg/L Ag. No significant effects of silver on time to 50% hatch were observed; however, time to 50% swim-up was delayed, and 50% swim-up was not achieved over the course of the experiment during some exposures to 1 microg/L Ag. These results suggest that the current Canadian Water Quality Guideline (http://www.ccme.ca/assets/pdf/e1_062.pdf) of 0.1 microg/L Ag is sufficient in preventing mortality and altered development in early life stages of rainbow trout. Increasing water hardness from 2 to 150 or 400 mg/L was modestly protective against the mortality and delays in time to 50% swim-up associated with exposure to 1 microg/L Ag. The 150- and 400-mg/L hardnesses were equally protective against mortality, but 150-mg/L was more protective than 400-mg/L hardness against the delays in time to 50% swim-up. Overall, the protective effects of hardness on chronic silver toxicity in early life stages of rainbow trout are modest but similar to the protection afforded to acute silver toxicity in juvenile and adult rainbow trout.

Animals↗

Effects of hardness and alkalinity in culture and test waters on reproduction of Ceriodaphnia dubia.

Ceriodaphnia dubia were cultured in four reconstituted water formulations with hardness and alkalinity concentrations ranging from soft to the moderately hard water that is required by whole-effluent toxicity (WET) testing methods for culturing test organisms. The effects of these culture formulations alone and in combination with two levels of Cl-, SO4(2-), and HCO3- on reproduction of C. dubia were evaluated with the standard three-brood test. Reproduction was significantly reduced when test waters had lower hardness than culture waters. However, reproduction was not significantly different when animals cultured in low-hardness waters were exposed to moderately hard waters. The hardness of the culture water did not significantly affect the sensitivity of C. dubia to the three anions. Conversely, increased hardness in test waters significantly reduced the toxicities of Cl- and SO4(2-), with HCO3- toxicity following the same pattern. Alkalinity exhibited no consistent effect on Cl- and SO4(2-) toxicity. The physiological stress of placing animals cultured in moderately hard water into softer test waters might contribute to marginal failures of otherwise nontoxic effluents. The standard WET protocol should be revised to allow the culture of C. dubia under lower hardness conditions to better represent local surface water chemistries.

Animals↗

[The influence of hard exudates on the results of vitrectomy for macular edema due to diabetic retinopathy].

PURPOSE: To demonstrate surgical results of diabetic macular edema from the distribution of hard exudates. METHODS: We reviewed 485 eyes of 325 patients followed up more than 1 year who underwent vitreous surgery for diabetic macular edema. Four groups were identified from the distribution of hard exudates in the macular region: no hard exudate type, 179 eyes; hard exudate type, 211 eyes; macular deposit type, 73 eyes; and waxy type, 22 eyes. We evaluated the preoperative characteristics, the period required for absorption of macular edema, visual outcome, and postoperative complications among the four types. RESULTS: In the waxy type, the macular edema was absorbed more slowly than no hard exudate type and hard exudate type(p < 0.05) more patients had proteinurea and were treated by grid photocoagulation before surgery than the other types, and the rate of occurrence of rubeotic glaucoma and attrition by death was higher than in the other types. Visual acuity was significantly improved in all types postoperatively(p < 0.05). Preoperative and postoperative visual acuity were as follows: no hard exudate type, 0.28, 0.48; hard exudate type, 0.21, 0.33; macular deposit type, 0.10, 0.17; and waxy type, 0.04, 0.11. CONCLUSION: The distribution of hard exudates was directly related to surgical results for diabetic macular edema. The waxy type had poor prognosis.

Diabetic Retinopathy↗

The hardness of horn in different segments of the bovine claw.

Hardness of bovine hoof horn was tested as ball indentation hardness and as shore D hardness post mortem in different segments of the hoof wall, in the sole and the hard bulb of sound claws of 10 Austrian Holstein Friesian cows. Both methods of hardness determination showed corresponding results, with shore D hardness between 52.2 and 63.9 hardness units (hu) and ball indentation hardness between 11.2 N/mm2 and 24.3 N/mm2. Bovine hoof horn becomes significantly softer from the coronary band towards the weight bearing border (vertical decrease) and from the dorsal wall towards the heel (horizontal decrease). Decreasing hardness was associated with decreasing dry matter content. Measurements of the claw capsule showed thickness of the hoof wall increasing from the coronary border towards the sole. In dorsopalmar/-plantar direction, bovine hoof wall at the weight bearing border decreases towards the heel.

Animals↗

The influence of storage and indenter load on the Knoop hardness of dental composites polymerized with LED and halogen technologies.

OBJECTIVES: The mechanical properties of light cured dental composites are greatly influenced by the light curing unit (LCU) used for the polymerization. Previous studies have shown that for some composites lower mechanical properties were obtained if light emitting diode (LED) LCUs were used for the polymerization instead of halogen LCUs. Previous studies have also shown that light cured composites improve their mechanical properties through a post-curing process after the initial illumination with the LCUs. Therefore, this study investigated the post-curing process, to ascertain if it can compensate for the lower mechanical properties of composites polymerized with LED LCUs. METHODS: The Knoop hardness was measured for four dental composites (Z100, Spectrum, Definite, Solitaire2) polymerized with an LED LCU (LED63 prototype) or a halogen LCU (Trilight), directly after the curing process and after 5 days of storage. In addition, the load on the indenter was varied from 200 to 400 gf to investigate the influence of the load on the measured hardness on the top and bottom of the 2 mm thick samples. RESULTS: In general the Knoop hardness at the bottom of the stored samples, cured with the LED LCU, was the same or statistically significantly greater than for the samples cured with the halogen LCU. A statistically significantly lower (p<0.0001) Knoop hardness was obtained on the top of the samples if the composite Definite was polymerized with the LED LCU instead of the halogen LCU. The load of 200 or 400 gf on the indenter had a statistically significant influence (p<0.0001) on the measured Knoop hardness for the composite Z100. The Knoop hardness measured with an indenter load of 400 gf increased statistically significantly (p<0.0001) for all composites after the 5 days' storage, whether cured with the LED LCU or halogen LCU. SIGNIFICANCE: The post-curing effect cannot compensate for the lower hardness of composites containing co-initiators if polymerized with an LED LCU instead of a halogen LCU. The indenter load had a statistically significant influence on the measured Knoop hardness of composites and has the potential to falsify results if not selected carefully.

Air↗

The hardness and modulus of elasticity of primary molar teeth: an ultra-micro-indentation study.

OBJECTIVE: Baseline information on the mechanical properties of and the effect of load upon dental hard tissue is important in the development of successful dental materials. Existing methods of measuring such properties of tissue are subject to significant experimental error. This study reports on the use of an Ultra-Micro-Indentation System (UMIS) to measure the hardness and elastic modulus of primary enamel and dentine. METHODS: Primary molar teeth were sectioned, set in resin and polished. Thirty indentations were made in enamel and dentine using a Berkovitch indentor, 15 of which were subject to a load of 50mN and 15 to a load of 150mN. An automated computerised system converted the force/penetration graph for each indentation in to a hardness vs depth graph from which values for the mean hardness and elastic modulus were calculated. RESULTS: Primary enamel had a mean hardness of 4.88+/-0.35GPa whilst the hardness of dentine was 0.92+/-0.11GPa The elastic modulus for enamel was 80.35+/-7.71GPa and that of dentine 19.89+/-1.92GPa. Using linear regression analysis a significant relationship could be shown between the hardness and the elastic modulus for both enamel and dentine when loaded to 150mN but only for dentine at 50mN (P<0.05). In general the elasticity of tooth structure increased as the hardness increased. CONCLUSION: The UMIS offers a simple and reproducible method of measuring basic mechanical properties of small samples of enamel and dentine.

Child, Preschool↗