Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dose reduction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Dose reduction to normal tissues as compared to the gross tumor by using intensity modulated radiotherapy in thoracic malignancies.

BACKGROUND AND PURPOSE: Intensity modulated radiotherapy (IMRT) is a powerful tool, which might go a long way in reducing radiation doses to critical structures and thereby reduce long term morbidities.The purpose of this paper is to evaluate the impact of IMRT in reducing the dose to the critical normal tissues while maintaining the desired dose to the volume of interest for thoracic malignancies. MATERIALS AND METHODS: During the period January 2002 to March 2004, 12 patients of various sites of malignancies in the thoracic region were treated using physical intensity modulator based IMRT. Plans of these patients treated with IMRT were analyzed using dose volume histograms. RESULTS: An average dose reduction of the mean values by 73% to the heart, 69% to the right lung and 74% to the left lung, with respect to the GTV could be achieved with IMRT.The 2 year disease free survival was 59% and 2 year overall survival was 59%. The average number of IMRT fields used was 6. CONCLUSION: IMRT with inverse planning enabled us to achieve desired dose distribution, due to its ability to provide sharp dose gradients at the junction of tumor and the adjacent critical organs.

Adult↗

Radiation dose reduction during endodontic therapy: a new technique combining an apex locator (Root ZX) and a digital imaging system (RadioVisioGraphy).

This study was undertaken on 14 teeth in order to evaluate a new technique for radiation dose reduction during endodontic therapy. After examination of the preoperative film, usually available in the patient file, an apex locator (Root ZX) was used to measure the working length. Complete chemomechanical debridement was then performed, and the master cone was evaluated by a digital imaging system (RadioVisioGraphy (RVG)). Obturation was performed when measurements of the electronic device and RVG were comparable. A postoperative image was made by the RVG system to evaluate the final obturation. A clinical and radiographic follow-up examination (follow-up period: 6 to 8 months) revealed satisfactory apical healing. These results indicated that a successful obturation technique can be performed by a single radiation exposure, using the RVG unit for master cone evaluation. This technique may be useful in medically compromised patients who need not to be exposed to excessive or repeated radiation during endodontic therapy.

Bismuth↗

[Rocuronium for anesthesia induction in elective procedures. Time course of muscular blockade and intubation after administration of 2-compartment ED95 (0.6 mg/kg) and dose reduction (0.4 mg/kg)].

BACKGROUND: Rocuronium is a non-depolarising neuromuscular blocking agent structurally related to vecuronium. The compound has a rapid onset and an intermediate duration of action. The rapid onset is of importance in patients at risk for pulmonary aspiration, for elective induction of anaesthesia slower onset properties generally are accepted. In this context, we asked whether the induction dose of rocuronium may be reduced to doses smaller than 2 x ED95 in situations in which slower onset properties may be acceptable. METHODS: The time course of neuromuscular block and intubating conditions of two different doses rocuronium, 2 x ED95 (0.6 mg/kg) and 1.3 x ED95 (0.4 mg/kg), were investigated in 90 patients. We first determined the time course of neuromuscular block using electromyography (EMG), n = 15 for each group. In the second part the intubating conditions 3 min after injection of either rocuronium 0.6 mg/kg or rocuronium 0.4 mg/kg were evaluated, n = 30 for each group. RESULTS: In the present study reduction of the dose of rocuronium led to a slower onset (148 +/- 32 s vs. 220 +/- 30 s; P < 0.05) and a shorter clinical duration (21 min +/- 4 vs. 36 +/- 7 min; P < 0.05). The recovery index was modified by the dose reduction: 11 +/- 3 min after 0.6 mg/kg rocuronium and 9 +/- 2 min after 0.4 mg/kg. After both doses of rocuronium the intubating conditions were good to excellent, no difference between both rocuronium groups were found. CONCLUSION: In the present study dose reduction from 0.6 mg/kg rocuronium to 0.4 mg/kg rocuronium led to a slower onset and reduced clinical duration. However, the intubating conditions, evaluated 3 min after injection of the muscle relaxant were comparable. This offers new possibilities for muscle relaxation for surgical or diagnostic procedures of short duration and may reduce costs.

Adult↗

Factors influencing the relapse risk at steroid dose reduction in myasthenia gravis.

In a selected group of 69 patients with myasthenia gravis treated with prednisone, the factors were studied that might have influenced the reoccurrence or exacerbation of clinical signs after initial improvement in two-thirds of the patients. It was not evident that the speed of dose reduction was responsible for the relapse in most patients. Azathioprine added to the prednisone regimen was found to reduce the relapse rate at steroid reduction. Pure ocular cases and patients who underwent thymectomy without thymoma had a higher chance to remain in remission after prednisone was stopped. Maintenance dose could be determined in 18 patients and was 0.42 mg/kg/2 d., but the difference between patients with or without azathioprine was not significant.

Azathioprine↗

Acute meningo-encephalitis on dose reduction of zidovudine.

In a study of treatment by zidovudine in 106 patients with the acquired immunodeficiency syndrome (AIDS) or AIDS-related complex, an acute meningo-encephalitic illness developed in 4 of 21 patients within 17 days after the dose of zidovudine had had to be reduced because of myelotoxicity. 3 of the 4 patients had previous clinical evidence of HIV encephalopathy. AIDS-related opportunist infection of the central nervous system was excluded. This acute meningo-encephalitic illness probably results from an increase in HIV replication following dose reduction.

AIDS-Related Complex↗

Withdrawal-emergent rabbit syndrome during dose reduction of risperidone.

Rabbit syndrome (RS) is a rare extrapyramidal side effect caused by prolonged neuroleptic medication. Here we present a case of withdrawal-emergent RS, which is the first of its kind to be reported. The patient developed RS during dose reduction of risperidone. The symptom was treated successfully with trihexyphenidyl anticholinergic therapy. The underlying mechanism of withdrawal-emergent RS in the present case may have been related to the pharmacological profile of risperidone, a serotonin-dopamine antagonist, suggesting the pathophysiologic influence of the serotonin system in the development of RS.

Adult↗

Radiation dose reduction in paediatric cranial CT.

BACKGROUND: There is no consensus about the optimal milliamperage-second (mAs) settings for computed tomography (CT). Most operators follow the recommended settings of the manufacturers, but these may not be the most appropriate settings. OBJECTIVE: To determine whether a lower radiation dose technique could be used in CT of the paediatric brain without jeopardising the diagnostic accuracy of the images. MATERIALS AND METHODS: A randomised prospective trial. A group of 53 children underwent CT using manufacturer's default levels of 200 or 250 mAs; 47 underwent scanning at 125 or 150 mAs. Anatomical details and the confidence level in reaching a diagnosis were evaluated by two radiologists in a double-blinded manner using a 4-point scoring system. RESULTS: For both readers there was no statistically significant difference in the confidence level for reaching a diagnosis between the two groups. The 95 % confidence intervals and P values were -0.9-1.1 and 0.13 (reader 1) and -1.29-1.37 and 0.70 (reader 2), respectively. Reliability tests showed the results were consistent. CONCLUSIONS: The recommended level may not be the optimum setting. Dose reduction of 40 % is possible on our system in paediatric brain CT without affecting the diagnostic quality of the images.

Brain↗

Radiation dose reduction in the neonatal intensive care unit. Comparison of three gadolinium oxysulfide screen-film combinations.

Infant radiation exposure in the neonatal intensive care unit was quantitated by thermoluminescent dosimetry in 513 mobile unit roentgen examinations of the chest and abdomen. Three combinations of gadolinium oxysulfide intensifying screens and radiographic films were compared. The skin entrance dose in millirads at the mid-chest, mid-abdomen and symphysis pubis levels was measured. Radiation dose reductions of 52% and 68% were achieved using the intermediate and fast combinations relative to the near par speed standard combination. Comparison of the relative line pair resolution of the three combinations under clinical conditions was done and subjective comparison of image detail and image mottle was made by two radiologists. The standard and intermediate speed combinations were considered very acceptable for general neonatal diagnostic interpretation but the fastest combination was not considered acceptable for general purposes. Because of the decreased radiation dose, the intermediate speed combination is now used for all routine neonatal radiography at our institution. The near par speed combination is now used only occasionally for "high-detail" examinations. The fastest combination has a limited role for frequently repeated, less critical studies, such as tube or catheter placement or routine follow-up examinations.

Gadolinium↗

BCG dose reduction by decreasing the instillation frequency: effects on local Th1/Th2 cytokine responses in a mouse model.

OBJECTIVES: Based on the requirement of a Th1 immune response for clinical efficacy, and incited by the arbitrary induction scheme, frequent side effects and the empirical approach in improving BCG immunotherapy for superficial bladder cancer, an alternative intravesical BCG treatment schedule for dose reduction was investigated without compromising Th1 cytokine induction in the bladder in a mouse model. METHODS: Mice were submitted to 6 weekly BCG instillations and treatment schedules omitting intermediate instillations during this standard scheme. Th1 (IFN-gamma, IL-2, IL-12p40), and Th2 (IL-10, IL-4) cytokine responses in individual mouse bladders were measured by a semiquantitative RT-PCR based method. RESULTS: A schedule of only two BCG instillations, administered in week 1 and week 6, resulted in induction of at least the same levels of IFN-gamma, IL-2 and IL-12p40 Th1 cytokine mRNA compared to 6 weekly instillations, whereas significantly lower levels of Th2 cytokines IL-10 and IL-4 mRNA were observed. CONCLUSIONS: During the 6-week period the intermediate weekly BCG instillations 2, 3, 4, and 5 do not contribute to Th1 cytokine upregulation in the bladder, provided that the BCG dose is sufficient. Whether such a reduced BCG frequency schedule has immune stimulating capacity and therapeutic efficacy associated with less side effects in patients remains to be investigated.

Administration, Intravesical↗

Changes in coagulation and fibrinolysis in childhood ALL: a two-step dose reduction of one E. coli asparaginase preparation.

The influence of two different E. coli asparaginase (ASP) preparations on fibrinolytic proteins in childhood ALL was recently reported, demonstrating a clearly significant association between ASP activity and haemostatic changes. Since the Bayer preparation is no longer available for treatment of large series of patients with ALL, the present study was designed to prospectively evaluate coagulation and fibrinolytic changes in leukaemic children receiving different doses of Medac ASP, which is now available for treatment of childhood ALL. Leukaemic children in whom ASP Medac was administered at 3 d intervals in a two-step dose reduction (5000 IU/m2, n = 10; 2500 IU/m2, n = 15) were compared with children who had received Bayer ASP 10,000 IU/m2 in the same time schedule in a former randomized trial; at the same venipuncture, blood samples for coagulation studies were obtained before each ASP administration together with serum samples for pharmacokinetic monitoring. Compared with Bayer ASP 10,000 IU/m2, patients receiving Medac ASP 5000 IU/m2 showed significantly decreased values of fibrinogen, plasminogen, and alpha 2-antiplasmin, along with significantly enhanced thrombin generation. Improvement occurred in children treated with 2500 IU/m2 Medac ASP; alpha 2-antiplasmin and D-dimer no longer differed from the Bayer group. Since both patient groups showed complete asparagine depletion during the course of ASP administration, the lower dosage of 2500 IU/m2 administered at 3 d intervals should guarantee the specific metabolic therapy for ALL, leading to depletion of the circulating pool of asparagine.

Antineoplastic Agents↗

Warfarin dose reduction vs watchful waiting for mild elevations in the international normalized ratio.

BACKGROUND: Whether clinicians should decrease the warfarin dose in response to a mild, asymptomatic elevation in the international normalized ratio (INR) is unknown. OBJECTIVES: The study objectives were as follows: (1) to evaluate the safety of an anticoagulation service (ACS) policy advocating that the warfarin dose not be changed for isolated, asymptomatic INRs of < or = 3.4; (2) to compare the dosing strategies of an ACS and primary care providers (PCPs); and (3) to quantify the relationship between reduction of the warfarin dose and the subsequent fall in the INR. DESIGN AND SETTING: Randomized controlled study of health maintenance organization outpatients who were receiving warfarin. PATIENTS: We identified 231 patients with a target INR of 2.5 and an isolated, asymptomatic INR between 3.2 and 3.4. Our ACS monitored 103 of the patients; PCPs monitored the remaining 128 patients. MEASUREMENTS: From all 231 patients, we obtained INRs and warfarin dosing history. From the 103 ACS enrollees, we also recorded adverse events. RESULTS: One ACS patient had epistaxis in the 30 days after the elevated INR. Twenty-three percent of ACS enrollees and 47% of PCP patients reduced their warfarin dose (p < 0.001). The median follow-up INRs were similar in both cohorts: 2.7 in the ACS enrollees and 2.6 in the PCP patients. However, in a subgroup analysis of 190 patients who presented with an INR of 3.2 or 3.3, ACS enrollees were more likely to have a follow-up INR in the range of 2 to 3 (p = 0.03). The median follow-up INR was 2.7 in 148 patients who maintained their warfarin dose, 2.5 in 77 patients who decreased their dose by 1 to 20%, and 1.7 in 6 patients who decreased their dose by 21 to 43% (p < 0.001). CONCLUSIONS: These findings support maintaining the same warfarin dose in asymptomatic patients with an INR of < or = 3.3, and reducing the dose for patients who have a greater INR or an increased risk of hemorrhage. Warfarin dose reductions > 20% should be avoided for mildly elevated INRs.

Aged↗

Amorphous silicon, flat-panel, x-ray detector versus screen-film radiography: effect of dose reduction on the detectability of cortical bone defects and fractures.

RATIONALE AND OBJECTIVES: The purpose of this phantom study was to assess the diagnostic performance of a self-scanning, solid-state amorphous silicon (a-Si) detector in skeletal radiography using different exposure parameters. METHODS: A flat-panel detector (15 cm x 15 cm), based on a-Si technology with 143 microm x 143 microm pixel size, 1k x 1k matrix, and 12 bit digital output was used. State-of-the-art screen-film radiography (SFR; speed 400, detector dose 2.5 microGy) was compared with a-Si images taken at doses that were equivalent to a speed of 400, 800, 1,250, and 1,600, respectively. A total of 232 segments of long tubular deer-bones (femur, tibia, humerus, radius) had 110 artificial fractures and 112 cortical defects simulating osteolytic lesions. Receiver operating characteristic analysis was performed for 9,280 observations made by four independent observers. Two-tailed Student's paired t test was used for statistical analysis (95% confidence level). RESULTS: Receiver operating characteristic analysis yielded equivalent results of the a-Si and SFR system. Even at the lowest dose there were no statistically significant differences between both imaging modalities with respect to the detectability of fractures and cortical defects. CONCLUSIONS: The results of this study indicate that a-Si detector technology holds promise in terms of dose reduction in skeletal radiography without loss of diagnostic accuracy.

Animals↗

Dose reduction in multi-slice CT of the heart by use of ECG-controlled tube current modulation ("ECG pulsing"): phantom measurements.

PURPOSE: To evaluate the effect of ECG-controlled tube current modulation on radiation exposure in retrospectively-ECG-gated multislice CT (MSCT) of the heart. MATERIAL AND METHODS: Three different cardiac MSCT protocols with different slice collimation (4 x 1, and 4 x 2.5mm), and a pitch-factor of 1.5 and 1.8 were investigated at a multi-slice CT scanner Somatom Volume Zoom, Siemens. An anthropomorphic Alderson-Rando phantom was equipped with LiF-thermoluminescence dosimeters at several organ sites, and effective doses were calculated using ICRP-weighting factors. Scan protocols were performed with ECG-controlled tube current modulation ("ECG pulsing") at two different heart rates (60 and 80 bpm). These data were compared to previous data from MSCT of the heart without use of "ECG pulsing". RESULTS: Radiation exposure with (60 bpm) and without tube current modulation using a 2.5 mm collimation was 1.8 mSv and 2.9 mSv for females, and 1.5 mSv and 2.4 mSv for males, respectively. For protocols using a 1 mm collimation with a pitch-factor of 1.5 (1.8), radiation exposure with and without tube current modulation was 5.6 (6.3) mSv and 9.5 (11.2) mSv for females, and 4.6 (5.2) mSv and 7.7 (9.2) mSv for males, respectively. At higher heart rates (80 bpm) radiation exposure is increased from 1.5 - 1.8 mSv to 1.8 - 2.1 mSv, using the 2.5 mm collimation, and from 4.6 - 5.6 mSv to 5.9 - 7.2 mSv, for protocols using 1 mm collimation. CONCLUSIONS: The ECG-controlled tube current modulation allows a dose reduction of 37 % to 44 % when retrospectively ECG-gated MSCT of the heart is performed. The tube current - as a function over time - and therefore the radiation exposure is dependent on the heart rate.

Coronary Angiography↗

[Dose reduction at abdominal CT imaging: reduced tension (kV) or reduced intensity (mAs)?].

PURPOSE: To compare low-dose protocols using either reduction of the tension (kV) or reduction of the intensity (mAs) at abdominal CT imaging, with reference to image quality. MATERIALS AND METHODS: Fifty adult patients, weighing less than 55 kg, were prospectively included among patients referred for abdominal CT examination when the protocol required a noncontrast study. The images obtained with the standard protocol (120 kV, 200 mAs) were compared to 4 additional test images, two obtained with low intensity (120 kV, 100 mAs) and two obtained with low tension (100 kV, 200 mAs). Two senior radiologists blindly reviewed all images using both subjective (itemized list) and objective criteria (measure of standard deviation for density measurements obtained of the liver parenchyma). RESULTS: The image quality of the low kV protocol was better than the image quality of the low mAs protocol for both subjective and objective criteria. CONCLUSION: For abdominal CT imaging of standard to thin adult patients or children, dose reduction using a low kV protocol may be an alternative to a protocol using a low intensity. This can easily be implemented and can be used in conjunction with a dose reducing software.

Abdomen↗

Radiation dose reduction in pediatric CT.

The relationship between image noise and radiation dose was investigated in computed tomography (CT) images of a pediatric abdomen phantom. A protocol which provided a minimum absorbed dose consistent with acceptable image noise criteria was determined for a fourth generation CT scanner. It was found that pediatric abdominal CT scans could maintain diagnostic quality with at least a 50% reduction in dose from the manufacturers' suggested protocol.

Child↗

CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction.

BACKGROUND AND PURPOSE: CT is a frequent examination that is performed using ionizing radiation. We sought to assess image-quality changes on CT scans of the head when the radiation dose is reduced by changing tube current and kilovoltage. METHODS: A formalin-fixed cadaver was examined in conventional and helical mode by use of two CT-scanners. Surface dose was measured with standard scanning parameters, and after reduction of tube current and kilovoltage. Five experienced examiners independently evaluated subjective image quality. RESULTS: In the conventional mode, the highest surface dose was 83.2 mGy (scanner 1: helical mode, 55.6 mGy), and 66.0 mGy (scanner 2: helical mode, 55.9 mGy). By changing kVp and mAs, a dose reduction of up to 75% (scanner 1), and 60% (scanner 2) was achieved. No observable differences in image quality between scans obtained with doses from 100% to 60% of standard settings were noted. Ten of 20 images obtained with the highest dose and 13 of 20 images obtained with lowest dose (19-29.4 mGy) were reliably identified by subjective quality assessment. Scans produced with a surface dose of less than 30 mGy were judged uninterpretable. CONCLUSION: Standard parameters used in cranial CT are oriented toward best image quality. A dose reduction up to 40% may be possible without loss of diagnostic image quality.

Cadaver↗

Randomised placebo controlled trial of beta agonist dose reduction in asthma.

BACKGROUND: Many patients continue to take regular beta agonists, often at high doses, contrary to national and international guidelines. Some studies have suggested that this can worsen asthma control, but whether such patients can reduce their dose of beta agonist and whether they would benefit from this has not been determined. Reduction of beta agonist dose was studied in a placebo controlled parallel group study. METHODS: Following a run in period, 33 subjects with asthma taking regular beta agonists were converted to an equivalent dose of terbutaline via a Turbohaler. Two weeks later terbutaline was continued at the same dose or changed to placebo in two stages a week apart. The change over period was covered by an increased dose of inhaled steroid to attenuate any immediate effects of the change in dose. Subjects then attended weekly for six weeks for measurement of forced expiratory volume in one second (FEV1) and the dose of methacholine that produced a 20% fall in FEV1 (PD20). Peak expiratory flow (PEF) and symptom scores were recorded twice daily throughout the study. Exacerbations, lung function, bronchial responsiveness, bronchodilator response, beta agonist use, and symptoms were compared before and six weeks after reduction in the dose of beta agonist. RESULTS: Twenty five of the 33 subjects completed the study; three patients in each group withdrew due to an asthma exacerbation. The median terbutaline dose fell from 2500 to 500 micrograms/day in the beta agonist reduction group and from 3000 to 2250 micrograms/day in the control group. There were small non-significant changes in FEV1, PEF, symptom scores and PD20 methacholine over the course of the study. The FEV1 response to a beta agonist was greater in those who reduced their beta agonist dose than in the control group although the final FEV1 achieved was the same. CONCLUSIONS: Patients with asthma taking high doses of beta agonists can reduce the amount of beta agonist they use without a significant change in their asthma control. There was no evidence of improved asthma control with beta agonist dose reduction.

Administration, Inhalation↗

Dose reduction in multidetector CT using attenuation-based online tube current modulation.

OBJECTIVE: This study was designed to quantify the radiation dose saved by attenuation-based online tube current modulation applied to multidetector CT (MDCT) of the adult trunk as a function of effective milliampere-second (mAs) presets, sex, and body habitus. SUBJECTS AND METHODS. One hundred twenty patients underwent MDCT of the trunk (60 thoracic, 60 abdominal) with an attenuation-based online tube current modulation. Consecutive acquisitions at standard and two lower effective mAs presets were obtained in each patient. Mean percentage effective mAs reductions were compared for each effective mAs preset, taking into account sex and body mass index. RESULTS: Mean effective mAs reduction was 16.9% and 20.0% for the chest and the abdomen, respectively. Mean percentage effective mAs reductions were found to be significantly different for sex (chest, p = 0.003; abdomen, p = 0.002) but not significantly different for the different effective mAs presets or body mass index. CONCLUSION: Attenuation-based online tube current modulation used with MDCT should be considered as a secondary tool of radiation dose reduction because it saves as much as 20% of the radiation dose on the adult trunk, regardless of initial mAs preset. However, initial decreases of mAs presets by the physician should be considered the primary tool for radiation dose reduction.

Adult↗