Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Digitation junction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Three-hundred-sixty degree barrier effect of a square-edged and an enhanced-edge intraocular lens on centripetal lens epithelial cell migration Two-year results.

PURPOSE: To study the 360-degree barrier effect of an intraocular lens (IOL) with a square edge at the optic and an enhanced square edge at the optic-haptic junctions (Rayner 570C C-flex) on centripetal migration of lens epithelial cells (LECs) over a 2-year period. SETTING: Department of Ophthalmology, Scarborough Hospital, Scarborough, United Kingdom. METHODS: In a prospective study of 40 consecutive eyes, a C-flex IOL was implanted in the bag after phacoemulsification surgery. Eyes with intraoperative complications, requiring additional procedures, without 360-degree overlap of the optic, or with capsule block syndrome were excluded. Follow-up was at 6, 10, 18, and 24 months. At each visit, high-magnification retroillumination digital photographs were taken using a slitlamp-attached digital camera. The barrier effect to LEC migration across the optic edge and the enhanced square edge at the optic-haptic junction was graded as complete (no epithelial pearls or sheet), partial (few epithelial pearls without sheet), and minimal/none (epithelial sheet behind the IOL optic). RESULTS: Twenty-four patients came to the final follow-up at 24 months. Fifteen of these eyes (63%) had a complete barrier effect throughout the 360 degrees of the IOL. Three eyes (13%) had a partial barrier effect throughout the 360 degrees of the IOL. Three eyes had a complete optic barrier effect but a partial optic-haptic junction barrier effect. Three eyes had a partial optic barrier effect but a complete optic-haptic junction barrier effect. No eye had epithelial sheets extending behind the optic at any location. CONCLUSIONS: This study showed the barrier effect of the edge design of the C-flex IOL and the efficacy of the enhanced edge in preventing LEC migration at the optic-haptic junction. The enhanced edge was as effective as a sharp square edge in restricting the LEC migration.

Acrylic Resins↗

A periodontal probe with automated cemento--enamel junction detection-design and clinical trials.

An automated periodontal probe has been developed to measure pocket depth and attachment loss in a single measurement under controlled force conditions. A natural anatomic landmark, the cemento-enamel junction (CEJ), is used as a reference for attachment level measurements. The CEJ is detected automatically by immediate digital postprocessing of simultaneous measurements of probe tip acceleration and displacement during probing. Clinical trials in the beagle dog model for naturally occurring periodontitis have shown that the automated probe, when used with 35 g probing force, has a repeatability of 0.16 mm and a bias of 0.09 mm. These results indicate that the automated periodontal probe is capable of attachment level measurements with a high degree of repeatability and validity.

Animals↗

Large dense-core vesicles at the frog neuromuscular junction: characteristics and exocytosis.

The population of large dense-core vesicles (LDCVs) in motor nerve terminals of the frog cutaneous pectoris muscle was analysed after various experimental protocols leading to large acetylcholine release. Three types of LDCVs classified according to their size and the core density were detected. Vesicles, 100-150 nm in diameter, with a large and very dense core (type 1) or with an irregular and diffuse dense core (type 2) were present in similar proportions (45 and 50% respectively) in controls. Smaller vesicles, 50-80 nm in diameter, with a very dense core (type 3) were rare, representing around 5% of the cored vesicles. The relative proportion of type 1 and type 2 LDCVs was not modified after prolonged treatment with 25 mM K+. In contrast, the proportion of type 2 LDCVs significantly increased whereas that of type 1 LDCVs decreased after two or three series of 20 Hz electrical stimuli applied to the nerve at 5 s intervals. These changes suggest that type 2 LDCVs are newly recycled LDCVs in the process of reloading. Images of fusion of LDCVs with the axolemma in regions facing Schwann cell digitations were observed both in K(+)- and in electrically stimulated preparations. They indicate that exocytosis of LDCVs at the frog neuromuscular junction takes place preferentially away from the active zones. The presence of a clathrin-like coat on large pockets still containing a core and of both type 1 and type 2 LDCVs in the vicinity of coated pockets strongly suggests that LDCVs might undergo a combined process of exo-endocytosis at the same site.

Animals↗

A transcondylar approach to the arteriovenous malformation at the ventral cervicomedullary junction: report of three cases.

Arteriovenous malformation at the cerevicomedullary junction is a rare disorder, usually presenting with subarachnoid hemorrhage. The diagnosis is difficult because of its anatomical location. In addition, the ventral location of these arteriovenous malformations makes surgical treatment difficult. We describe three cases surgically treated with a transcondylar approach. The usefulness of digital subtraction angiography and magnetic resonance imaging is discussed. The technique of the transcondylar approach is also described, including C1 hemilaminectomy, unroofing of the transverse foramen of C1 to obtain control of the vertebral artery, and partial resection of the occipital condyle and lateral atlantal mass by extradural drilling. This approach provides direct access to the ventral portion of the cervicomedullary junction.

Aged↗

Precision of computerized measurement of marginal alveolar bone height from bite-wing radiographs.

The digitizer technique has previously shown good precision when applied to measurements of alveolar marginal bone height on unstandardized periapical radiographs of adults. In this study the precision of the digitizer technique was evaluated for direct measurement of alveolar bone height on unstandardized bite-wing radiographs of young subjects with intact cemento-enamel junctions. Measurements of the distance between the cemento-enamel junction and the alveolar crest at 432 sites gave an agreement of 96.5% within a margin of error of 0.3 mm. The T-test showed no significant difference between repeated measurements of the same site. Regression analysis showed that the order of magnitude of the distance between the landmarks did not influence the results. The mean difference between repeated readings of the same site was 0.09 mm at a confidence limit of 99.9%. The study confirms that the digitizer technique is a reliable method for measurement of alveolar bone height on unstandardized bite-wing radiographs of young subjects.

Adolescent↗

Dynamic rectal examination: its significant clinical value.

The aim of the present study was to carry out a proper correlation between patients' clinical symptoms and the radiological findings obtained by dynamic rectal examination (DRE). At DRE, the small bowel and in females the vagina are routinely opacified in addition to defecography. A prospective study of 248 consecutive patients (193 women and 55 men, ratio 3.5:1) and 14 control subjects was conducted. The parameters assessed included the anorectal angle, the position of the anorectal junction, and the total movement of the pelvic floor during squeezing and defecation. Anatomical changes as rectoceles, enteroceles and intussusceptions were also observed. Based on the findings, the following conclusions can be drawn. There is no indication for measurement of the central or posterior anorectal angle. There is no indication for measurement of the perineal ascent, perineal descent, and anorectal junction level. Anterior rectoceles occur very frequently in females, and are only of clinical relevance if the patients need digital vaginal support to facilitate defecation. DRE is a sensitive method for diagnosing enteroceles and intussusceptions.

Anal Canal↗

Radiographic parameters as prognostic indicators for healing of class II furcation defects.

OBJECTIVE: To evaluate radiographic measurements for use as prognostic indicators for healing of class II furcation defects following regenerative therapy. MATERIAL AND METHODS: In 17 patients (eight females), 33 class II furcation defects (mandibular buccal (n=10) and lingual (n=12), and maxillary buccal (n=11)) were treated using the barrier membrane technique. Twenty-six furcations were treated using a bioabsorbable membrane, while a nonresorbable membrane was used to treat the remaining seven furcation defects. Clinical parameters and standardized radiographs were obtained before as well as 6 and 24 months after therapy. All radiographs were digitized and evaluated by an examiner blinded to the clinical data. The following distances were measured: cemento-enamel junction line (CEJ-line) to alveolar crest (AC) at the furcation site (AC-CEJ line), CEJ-line to the furcation fornix (Fx-CEJ line), width of the furcation at the level of the AC (FW) as well as the distance from Fx to a straight line between the AC mesial and distal of the tooth (Fx-AC line). RESULTS: Statistically significant (p<0.001) horizontal attachment gains could be observed 6 and 24 months after therapy (6 months: 1.49+/-0.85 mm; 24 months: 1.14+/-0.91 mm). However, a small but statistically significant (p=0.031) attachment loss of 0.35 mm was observed between the 6 and 24 months examination. Multilevel regression analyses identified baseline probing depth (p=0.0017) and 3 of the radiographic distances as prognostic factors: Fx-CEJ line (p=0.014), FW (p=0.0535), Fx-AC line (p=0.0827). CONCLUSION: The analysis of presurgical radiographs may yield information on the success of the regenerative therapy of buccal and lingual class II furcation defects. A long root trunk, a wide furcation entrance and an Fx coronal to the AC have negative influences on the success of therapy. Further, a deep probing depth at the furcation site at baseline increases the likelihood for more favourable horizontal attachment gain in furcations.

Absorbable Implants↗

Comparison of manual and digital measurements in adolescent idiopathic scoliosis.

STUDY DESIGN: Comparison of manual and digital measurement of radiographic parameters in patients with adolescent idiopathic scoliosis (AIS). OBJECTIVE: To assess the reliability of digital measures as compared to manual measures in the evaluation of AIS. SUMMARY OF BACKGROUND DATA: Radiographic parameters are critical to the evaluation of patients with AIS, and are frequently used to monitor curve progression and guide treatment decisions. The reliability of many of the more common radiographic measures has only recently been elucidated for both manual and digital measures. However, a comparative analysis of manual versus digital measures has been performed only for coronal Cobb angles. The inter-technique reliability of these parameters will have increasing importance as digital radiographic viewing and analysis become commonplace. METHODS: There were 2 independent, blinded observers that measured 30 complete sets of preoperative (posterior-anterior, lateral, and both side-bending) and postoperative (posterior-anterior and lateral) radiographs on 4 different occasions. For the first 2 iterations, manual measurements were taken using the same pencil and protractor. For the last 2 iterations, measurements of digitized radiographs were taken on a software measurement program (PhDx, Albuquerque, NM). Coronal measures included the main thoracic and thoracolumbar/lumbar standing and side-bending Cobb angles, apical vertebral translation, coronal balance, T1 tilt angle, lowest instrumented vertebrae angle, angulation of the disc inferior to the lowest instrumented vertebrae, apical Nash-Moe vertebral rotation, and Risser grade. Sagittal parameters included T2-T5 and T5-T12 regional thoracic kyphosis, T2-T12 thoracic kyphosis, T10-L2 thoracolumbar junction sagittal curvature, T12-S1 lumbar lordosis, and global sagittal balance. The technique-dependent measurement variability and the inter-technique (manual vs. digital), intraobserver reliability were evaluated for each radiographic parameter (within 3 degrees ). RESULTS: Digital measurement showed decreased intraobserver variability for many (9 of 15) of the radiographic parameters assessed. Likewise, digital measures indicated good or excellent correlation with the absolute values obtained with manual measurement for many (10 of 15) parameters. All but 1 of those parameters having moderate-to-poor correlation had been previously shown to have poor reliability, regardless of measurement technique. Statistically significant differences between measurement variability were noted for 6 measures, including 2 favoring digital and 4, manual. Significant differences in the absolute values were noted for 5 measures, determined at a difference of 3 degrees . However, the differences in both parameter variability and absolute values tended to be small and of little clinical significance for manual versus digital measurement. CONCLUSIONS: Digital measurement showed improved measurement precision and good correlation with manual measurements for the majority of AIS parameters. Absolute differences between manual and digital measurements were generally small. Therefore, digital measures are acceptable as a valid technique for scoliosis evaluation. The importance of digital versus manual measurement reliability will increase as digital radiographic viewing becomes more prevalent.

Adolescent↗

Gap junction processing and redistribution revealed by quantitative optical measurements of connexin46 epitopes in the lens.

PURPOSE: To map changes in the structure and function of fiber cell gap junctions that occur with lens differentiation. METHODS: Equatorial lens sections were fluorescently labeled with antibodies to the gap junction protein connexin (Cx)46, the membrane marker wheat germ agglutinin, and the nuclear stain propidium iodide. Two-photon microscopy and digital image analysis were used to quantify label and cell morphology as a function of radial distance (r/a) across the lens. Loop- and tail-specific Cx46 antibodies were used to identify regions of posttranslational modification. Local fiber cell coupling was imaged in situ using two-photon flash photolysis of caged fluorescein. RESULTS: Antibody labeling showed that the cytoplasmic tail of Cx46 was removed in two zones (r/a approximately 0.9 and r/a approximately 0.7). In addition, with increasing depth, the large radially aligned plaques of peripheral fiber cells became fragmented and dispersed around the cell membrane, and cells became more circular in cross section. Fluorescein transfer between peripheral fiber cells was highly anisotropic and occurred predominantly within a column of fiber cells, resulting in radially directed transport. In regions beyond the zone of nuclear loss, transport was more isotropic and occurred across columns of fiber cells. CONCLUSIONS: The cleavage of Cx46 is associated with a spatial redistribution of gap junction plaques. The distribution of gap junction plaques around the cell membrane can explain the observed directionality of intercellular solute transfer. The findings suggest that the processing and redistribution of gap junction proteins is central to controlling radial and circumferential solute gradients in different regions within the lens.

Animals↗

Effects of weight bearing on the tidemark and osteochondral junction of articular cartilage: histomorphometric analyses of 7 normal femoral heads.

To study the effect of weight bearing on the tidemark and osteochondral junction, we compared the morphology of these two boundaries in weight-bearing and less weight-bearing regions of normal human femoral heads. We measured the irregularities of the boundaries in the two regions using an X-Y digitizer connected to a computer in histological whole sections of femoral heads in 7 subjects without joint diseases. The irregularity of the tidemark was small, showing no difference between the two regions. However, the irregularity of the osteochondral junction in the weight-bearing region was greater than in the less weight-bearing region, which was confirmed by three-dimensional reconstructed images. Our findings suggest that mechanical stresses greatly influence the morphology of the osteochondral junction compared to the influence of such stresses on the tidemark, and that the marked irregularity of the osteochondral junction in the weight-bearing region is a reactive phenomenon against mechanical fragility due to simple contact between calcified cartilage and subchondral bone without fibrous connections.

Aged↗

Controlled freezing of nonideal solutions with application to cryosurgical processes.

Success of a cryosurgical procedure, i.e., maximal cell destruction, requires that the cooling rate be controlled during the freezing process. Standard cryosurgical devices are not usually designed to perform the required controlled process. In this study, a new cryosurgical device was developed which facilitates the achievement of a specified cooling rate during freezing by accurately controlling the probe temperature variation with time. The new device has been experimentally tested by applying it to an aqueous solution of mashed potatoes. The temperature field in the freezing medium, whose thermal properties are similar to those of biological tissue, was measured. The cryoprobe temperature was controlled according to a desired time varying profile which was assumed to maximize necrosis. The tracking accuracy and the stability of the closed loop control system were investigated. It was found that for most of the time the tracking accuracy was excellent and the error between the measured probe temperature and the desired set point is within +/- 0.4 degrees C. However, noticeable deviations from the set point occurred due to the supercooling phenomenon or due to the instability of the liquid nitrogen boiling regime in the cryoprobe. The experimental results were compared to those obtained by a finite elements program and very good agreement was obtained. The deviation between the two data sets seems to be mainly due to errors in positioning of the thermocouple junctions in the medium.

Analog-Digital Conversion↗

An in vivo equine forelimb model for short-term recording of peak isometric force in the superficial and deep digital flexor muscles.

OBJECTIVE: To develop and test an experimental model for in vivo short-term recording of peak isometric forces of the digital flexor muscles in the forelimb of adult horses. STUDY DESIGN: In vivo experimental study. SAMPLE POPULATION: Four healthy, anesthetized, adult Thoroughbred horses (3 to 7 years old; 527 +/- 87 kg) METHODS: In dorsal recumbency, ulnar and median nerves were exposed and instrumented with insulated bipolar cuff stimulation electrodes for later connection to an electrical stimulator. In left lateral recumbency, a biplanar fixator was applied to the right humerus and a custom-made, rigid, aluminum frame connected to it, to allow loading of muscles distal to the fixator. Threaded transfixation pins through the radial and metacarpal condyles were clamped to the rigid frame so that the humerus, radius, ulna, and metacarpus were fixed in position. Each digital flexor muscle insertion tendon was transected just above the metacarpophalangeal joint, extracted from the carpal canal, and secured in a metal clamp positioned at the distal myotendinous (MT) junction. Distally, the clamp was connected in series to a load cell and a pneumatic actuator to record force and to maintain muscle length during nerve stimulation. A linear potentiometer was connected in parallel to the actuator to record MT junction position. Initial trials were conducted to identify median and ulnar nerve stimulation variables to achieve maximal muscle contraction. Isometric contractions were performed at different muscle lengths and peak forces registered during 3 seconds of supramaximal dual (ulnar and median) nerve stimulation. RESULTS: A stimulation voltage of 2.5 to 5.0 V at 50 Hz usually produced maximal force for both the superficial digital flexor (SDF) and deep digital flexor (DDF) muscles. Single ulnar and median nerve stimulation elicited force development not only in the DDF muscle but also in the SDF muscle. At voltages higher than 1 V, normalized force was greatest with combined median and ulnar nerve stimulation for both the DDF and SDF muscles; however, normalized force was greater for median nerve stimulation than ulnar nerve stimulation in the DDF muscle, and the opposite relationship was observed for the SDF muscle. Final recording of dual supramaximal nerve stimulation of SDF and DDF muscles resulted in peak isometric forces of 716 +/- 192 N and 1,577 +/- 203 N, respectively. CONCLUSIONS: The instrumentation technique and experimental protocol enabled recording of peak isometric forces in the SDF and DDF muscles of anesthetized adult horses. CLINICAL RELEVANCE: Studies using this model will improve knowledge of SDF and DDF muscle mechanics with insight to functional implications of the complex architecture of these muscles. Knowledge of the dynamic performance of the SDF and DDF muscles would also be useful for the development of new treatment strategies for flexor deformities and tendon injuries in horses.

Animals↗

Permeance of Novikoff hepatoma gap junctions: quantitative video analysis of dye transfer.

Fluorescent dyes are commonly used to study permeable (gap) junctions, but only rarely have quantitative values for junctional dye permeability been determined. In the present study, junctional permeance (PA, i.e., the product of the junctional permeability coefficient, P, times the junctional area, A) to Lucifer Yellow CH (LY) has been obtained for pairs of Novikoff hepatoma cells. Dye was microinjected into one cell and the subsequent transfer monitored by a SIT camera and recorded on video tape. The intensities of fluorescence in the injected and "recipient" cell were measured using a Digisector (Microworks) digitizing board and an Apple II Plus computer to analyze the video records. These changes in intensity, along with an estimate of volume of the spherical cells, were used to calculate the junctional permeance (PA) of cell pairs according to Fick's diffusion equation. Junctional permeances show considerable variation ranging from 0.08 X 10(-11) to 27.0 X 10(-11) cm3/sec. Using the mean PA and a previous estimate of the mean number of junctional channels per interface in the Novikoff cultures, a value for diffusion coefficient of LY through gap junctions is calculated to be about 1.4 X 10(-6) cm2/sec. There is a general proportionality between mean PA and cell volume for hepatoma cell pairs of a certain size range. Such a relationship between cell volume and junctional capacity suggests one source of variation of PA. Other possible sources, e.g., related to position in the cell cycle, are discussed.

Animals↗

Root curvature: differences among dental morphotypes and modifications after mechanical instrumentation.

BACKGROUND: This study was designed to describe a method for measuring root curvature of extracted teeth, compare root curvature of four different dental morphotypes before mechanical instrumentation, and measure root curvature after mechanical instrumentation. METHODS: Fifty-five maxillary (14 central incisors, 13 lateral incisors, 14 cuspids, 14 premolars) extracted teeth were analyzed. Measurements were recorded on the horizontal plane at the most apical point of the cemento-enamel junction (CEJ). A 4 mm wide root portion on the buccal aspect was selected and recorded on this plane. A digital scanner traced the circle coinciding with the profile of this root portion and calculated its radius, arc, chord, and arrow (i.e., the perpendicular bisector of the chord). Since root curvature is the inverse of the radius (1/r), the radius was related to root curvature; the arc to the mesio-distal dimension of the root portion; and the reduction of the arrow to root flattening after mechanical instrumentation. The measurements were recorded four times: before treatment (baseline), after polishing, after a first root planing, and after a second root planing. The radii of each dental morphotype (upper central incisors, upper lateral incisors, upper canines, upper premolars) recorded in the first measurement were calculated and used for the statistical analyses: one-way analysis of variance (ANOVA) test and the Tukey multiple comparison method were used to study the curvature. The measurements of the radius, the arc, and the arrow at the four times were used for the statistical analyses: the two-way ANOVA test and the Tukey multiple comparison method were applied in the study of the root modifications after mechanical instrumentation. The accuracy and reliability of the method were also evaluated. RESULTS: The mean radii of the four dental morphotypes were: central incisors: 3.613 +/- 0.258 mm; lateral incisors: 2.558 +/- 0.256 mm; canines: 2.822 +/- 0.238 mm; and premolars: 2.321 +/- 0.179 mm. The statistical analyses revealed differences among central incisors, canines, lateral incisors, and premolars. There was no statistically significant difference between lateral incisors and premolars. Regarding the root modifications after mechanical treatment, the radius did not show statistically significant differences in any of the comparisons. The arc and the arrow did not show significant differences between baseline and polishing, while they did show significant differences after the second root planing. CONCLUSIONS: This study indicates that: 1) the method of measuring is accurate and reliable; 2) there are statistically significant differences among the root curvatures of different dental morphotypes; and 3) polishing did not modify the root. A vigorous root planing did not modify root curvature, but it did reduce the mesio-distal dimension and flatten the root surface slightly.

Analysis of Variance↗

Telemedicine system for home automated peritoneal dialysis.

We have developed a new telemedicine system to monitor elderly and handicapped patients that use an automated peritoneal dialysis (APD) system to perform continuous ambulatory peritoneal dialysis (CAPD) at home. The system has two parts: (1) a data collection and transport system, and (2) an interview system ("View Send" system). The former is assembled from the APD cycler, an automated blood-pressure recorder, and a scale. The latter is a combination of a digital camera, television, and set-top box (a kind of computer). The APD system contains recording and data transport junctions, a monitoring device, and a data tabulation function. All data collected by the APD system are sent directly in real time to the physician's office. Patients can easily use this telemedicine system to contact the medical staff at the Saitama Medical School CAPD center and to consult concerning their condition. Furthermore, the staff can directly change the CAPD schedule (dose and duration). Seven patients, including some who are older than 90 years or who are handicapped, have been using this telemedicine system for between 1 and 6 months (average: 3 months). From our recent experience, our tentative conclusions are that (1) elderly and handicapped patients benefit from this system by being able to maintain CAPD without major problems and accidents; (2) other problems are mainly due to simple mistakes such as accidentally pushing the on and off switches; (3) quality of life is improved for the patients.

Aged↗

Vascular network changes in the retina with age and hypertension.

OBJECTIVE: To compare retinal arterial bifurcation geometry in normotensive and hypertensive subjects. DESIGN: A retrospective observational study. METHODS: Fluorescein angiograms of normotensive (n = 13) and hypertensive (n = 12) subjects aged 30-80 years with uni-ocular retinal pathology were compared. Quantification of diameters of the parent, larger daughter and smaller daughter vessels (d0, d1 and d2, respectively) and of bifurcation angles (the angle between the two daughter arterioles, omega) of arteriolar bifurcations was performed from digitized retinal angiograms of the uninvolved eye. The relative diameters of parent and daughter vessels at bifurcations were summarized by junction exponents (x) such that d1x + d2x = d0x. RESULTS: Junction exponents were similar for normotensives and hypertensives (means +/- SEM, 2.65 +/- 0.18 and 2.48 +/- 0.17), but analysis of covariance showed a parallel decrease in x in the two groups with age. A positive association was found between x and arteriolar microvascular density. Bifurcation angles were more acute in hypertensives (74 +/- 3 degrees) than in normotensives (84 +/- 3 degrees) and declined with increasing age in both groups. CONCLUSIONS: The present findings indicate that ageing and possibly hypertension are associated with disadvantageous branching geometry in the human retinal vasculature, implying increased power costs of blood transport, uneven distribution of shear forces throughout the vascular tree and microvascular rarefaction. The present findings may have important implications for our understanding of the pathogenesis of vascular disease in ageing and hypertension and offer the prospect of a novel sensitive diagnostic approach to the cardiovascular system.

Adult↗