Search PubMedSearch

SEARCH · Search PubMed

Search Search PubMed

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

7 recordsLinked to original sources

Clinical insights into catathrenia: A real-world analysis from a tertiary sleep center.

INTRODUCTION: Catathrenia is a rare sleep-related breathing disorder marked by groaning during prolonged expiration, often underrecognized or misdiagnosed as obstructive or central sleep apnoea (OSA or CSA) or parasomnia. Understanding its clinical and polysomnographic features is essential for accurate diagnosis and management. MATERIALS AND METHODS: We performed a retrospective observational study of adult patients diagnosed with catathrenia at Serviço de Medicina do Sono de Coimbra. Diagnosis was established by attended overnight polysomnography (PSG) with synchronised audio-video recording. Demographic data, symptoms, comorbidities, PSG variables, treatment modalities, and outcomes were reviewed. Catathrenia events were defined as deep inhalation followed by prolonged exhalation with monotonous groaning. RESULTS: Ten patients were included. Median age was 46 years (range 27-78), mostly female (70%). Common comorbidities included obesity (n = 4), depression (n = 2), Parkinson's disease (n = 1), and restless legs syndrome (n = 1). Six patients (60%) had concomitant obstructive sleep apnoea (OSA). Seven patients had excessive daytime sleepiness (Epworth Sleepiness Scale > 10). All catathrenia episodes occurred exclusively during REM sleep. Continuous positive airway pressure (CPAP) therapy was the most frequently used treatment and was associated with objective or subjective improvement in most patients. Two patients experienced spontaneous remission. CONCLUSION: Catathrenia remains underdiagnosed and can mimic other sleep disorders. Recognition of its REM-sleep predominance and PSG pattern is essential. Individualised treatment, often involving PAP therapy, may improve symptoms and patient outcomes.

Humans

Sleep stage-dependent distribution of interictal epileptiform discharges in epilepsy: A systematic review.

BACKGROUND: Sleep and epilepsy interact through complex bidirectional mechanisms. Although NREM sleep facilitates interictal epileptiform discharges (IED), the diagnostic contribution of individual sleep stages remains uncertain. In particular, it is unclear whether deeper sleep stages such as N3 provide an advantage over N2 for spike detection or localization in clinical (electroencephalography) EEG practice. METHODS: This systematic review followed PRISMA 2020 guidelines. PubMed and Web of Science were searched for studies reporting quantitative IED measures across sleep stages in patients with epilepsy. Eligible studies included scalp EEG, video-EEG, polysomnography, or intracranial recordings. Mean IED rates per minute were derived when possible. Comparisons between NREM and REM sleep and between N2 and N3 stages were performed using study level non-parametric tests. Risk of bias was assessed with the ROBINS-I tool. RESULTS: Ten observational studies including 266 patients (mean age 30.1 years) were analyzed. IED rates were significantly higher during NREM than REM sleep (Wilcoxon signed-rank test, W = 0, p = 0.0019, r = 0.87). No significant difference was observed between N2 and N3 sleep, although median spike rates were slightly higher during N3 than N2 (0.99 vs 0.86 IED/min). REM showed the lowest activity. CONCLUSIONS: NREM sleep consistently exhibited higher IED rates than REM sleep, reinforcing the neurophysiological association between sleep stage and epileptiform activity without establishing diagnostic superiority.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift™), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3 ± 13.2 years; mean AHI 22.9 ± 13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

HYPNOSA: Study protocol for a prospective observational cohort of patients with obstructive sleep apnea.

BACKGROUND: Obstructive Sleep Apnea (OSA) is a common chronic disease that affects more than 20% of the adult population. One of the most frequent and characteristic symptoms of OSA is excessive daytime sleepiness (EDS). This symptom is typically treated in patients with OSA with the application of continuous positive airway pressure (CPAP), the gold-standard treatment for this disease. In some patients who are adequately treated with CPAP, residual excessive daytime sleepiness (REDS) persists. The prevalence, associations, and outcomes associated with REDS remain poorly understood. METHODS: Multicenter, prospective, observational cohort study including 1000 patients. Participants will undergo a sleep study for the diagnosis of obstructive sleep apnea (OSA), 24-h ambulatory blood pressure monitoring, clinical assessment, quality-of-life questionnaires, Epworth Sleepiness Scale, and collection of biochemical variables and biological samples. Patients with OSA will receive standard care, and those prescribed continuous positive airway pressure (CPAP) will be monitored for treatment adherence. OSA patients will be assessed at baseline and at 6, 12, and 24 months. DISSCUSION: We aim to establish a prospective observational cohort of patients with obstructive sleep apnea (OSA) treated with CPAP, with and without REDS. The HYPNOSA project will create the largest available registry of patients with OSA and REDS using real-world data, providing accurate prevalence estimates and long-term outcomes. Biological samples will be analyzed to assess the role of specific biomarkers. TRIAL REGISTRATION: Registered at ClinicalTrials.gov. Identifer: NCT06514482.

Adult

Assessing the effects of non-invasive transcranial electrical stimulation (tACS and tDCS) on electrophysiological sleep parameters - a systematic review.

Transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), is considered a safe method to modulate cortical activity and endogenous brain oscillations. Given the therapeutic potential of tES across various clinical conditions and the central role of sleep in restoration and memory consolidation, numerous studies have investigated its effects on sleep and sleep-related parameters, yielding inconsistent results. This systematic review provides an up-to-date synthesis of 51 studies assessing the impact of tES on objectively measured electrophysiological sleep outcomes in both healthy individuals and clinical populations. The reviewed studies demonstrate heterogeneous effects, reflecting substantial variability in study designs. Nonetheless, consistent trends emerge, including reduced NREM1 and increases in total sleep time, NREM2, and NREM3 following tES. Moreover, slow-oscillatory tES increased slow-wave power during sleep. Here we show that tES, particularly slow-oscillatory tES, may positively influence sleep architecture and continuity by modulating endogenous brain oscillations. However, due to heterogeneous stimulation protocols, inconsistent findings, the limited number of significant effects and substantial risk of bias the current evidence remains inconclusive. Well-designed, large-scale trials targeting specific sleep outcomes are needed to clarify the therapeutic potential of tES.

Humans

The potential of clustering methods for pre-test triage in sleep medicine: A systematic review.

Sleep disorders exhibit substantial heterogeneity, and traditional classifications may not fully capture clinically relevant subtypes. Clustering techniques can identify patient subgroups that improve phenotypic characterization and may support personalized management. This systematic review evaluated the application of clustering in sleep medicine, with particular focus on its potential use as a pre-test triage tool prior to formal sleep testing. PubMed/MEDLINE, Embase, Web of Science, and Scopus were searched to February 2025. Eligible studies applied clustering to classify sleep disorders in adults. Two reviewers independently conducted screening, data extraction, and risk-of-bias assessment using QUADAS-2. The protocol was registered on PROSPERO. Fifty-one studies (1983-2025) were included, predominantly focused on obstructive sleep apnea (OSA) (n = 38, 74%). Hierarchical clustering (n = 20) and K-means clustering (n = 14) were the most frequently used techniques. Internal validation was reported in only 18% of studies, and external validation was reported in only 1 study. Seven studies relied exclusively on baseline clinical, demographic, or questionnaire data, representing pre-test scenarios, whereas most incorporated polysomnography-derived variables, limiting their applicability to early clinical stratification. Hierarchical clustering was the most commonly applied method; however, the overall lack of validation limits confidence in the robustness and clinical applicability of identified phenotypes. The potential role of clustering as a pre-test triage strategy remains largely unexplored, as most studies focused on post-diagnostic phenotyping and were affected by incorporation bias. Future research should prioritize pre-test clinical variables, rigorously validate internally and externally, and adopt standardized methodological and reporting practices to facilitate clinical translation.

Humans

Treatment of OSA using mandibular advancement versus CPAP in improving cardiovascular health.

BACKGROUND: Obstructive sleep apnea is a significant risk factor for hypertension. We assessed the relative effectiveness of mandibular advancement device (MAD) versus continuous positive airway pressure (CPAP) in reducing 24 h ambulatory blood pressure (BP) and other health-related outcomes over 12 months. METHODS: In a randomized, non-inferiority trial, 321 participants with hypertension and increased cardiovascular risk were recruited for polysomnography. Of these, 220 with moderate-to-severe OSA (apnea-hypopnea index (AHI) &#x2265;15 events/hour) were randomized to MAD or CPAP (1:1). We report the final outcomes at the 12-month follow-up. RESULTS: A total of 180 participants (MAD: 89; CPAP: 91) completed the 12-month follow-up. Median usage for MAD and CPAP was 5.5 and 4.9 h per night, respectively. Compared to baseline, the 24 h mean arterial BP at 12 months decreased by 2.3 mmHg (P = 0.200) in the MAD group and by 1.0 mmHg (P = 0.999) in the CPAP group. The difference between-groups was -0.6 mmHg (95% confidence interval: -2.53 to 1.39, non-inferiority P < 0.019). The MAD group demonstrated a larger reduction in asleep BP compared to the CPAP group. The prevalence of excessive daytime sleepiness in the MAD group decreased from 30.3% at baseline to 10.1% at 12-month follow-up (P = 0.001), and from 38.5% to 7.7% in the CPAP group (P < 0.001). The between-group difference was 10.6% (P = 0.097). No significant within-group or between-group differences were observed in the prevalence of arrhythmias and plasma levels of cardiac biomarkers. CONCLUSION: At 12-month, MAD is non-inferior to CPAP for reducing 24 h mean arterial BP in participants with hypertension and increased cardiovascular risk. TRIAL REGISTRATION: NCT04119999.

Humans