Search PubMed⌕ Search

PubMed · 999052

A note on serological interpretations.

Abstract

This paper deals with the interpretation of binary serological data. It attempts to render exact and answer two questions: 1) What are all the serological interpretations of a given set of data? 2) How can different interpretations be distinguished serologically? It is hoped that the formal analysis of serology presented herein will prove to be helpful to those working with complex immunological systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Denniston. 1976. A note on serological interpretations.. https://pubmed.ncbi.nlm.nih.gov/999052/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Isolation and characterization of phage-displayed single chain antibodies recognizing nonreducing terminal mannose residues. 2. Expression, purification, and characterization of recombinant single chain antibodies.

Since phage-display technology is probably the best available strategy to produce antibodies directed against various carbohydrate moieties, we employed phage-display technology to generate human single chain antibodies (scFvs) using neoglycolipids as carbohydrate antigens. An accompanying paper in this issue describes how phage-displayed antibodies (phage Abs) that recognized nonreducing terminal mannose residues were isolated and characterized. In this study, four independent scFv genes, isolated by a mannotriose (Man3)-bearing lipid as an antigen as previously described, were used to construct expression vectors to produce soluble scFv proteins in quantity. Both bacterial and mammalian expression systems were used to produce glutathione S-transferase-scFv fusion proteins and scFv-human IgG1 Fc conjugates, respectively. The expressed scFv fusion proteins were purified to apparent homogeneity with yields of approximately 1 and 48 mg, from 1 L of bacterial culture and myeloma cell media, respectively. Surface plasmon resonance and ELISA analyses confirmed that purified scFv proteins showed Man3 specificity. The humanized antibody in scFv-Fc form, derived from clone 5A3, was a disulfide-liked dimer with a molecular mass of 108 kDa. According to a bivalent model, the kinetics parameters of its binding to Man3 were determined to be ka = 4.03 x 104 M-1 s-1, kd = 5.77 x 10-4 s-1, KA = 6.98 x 107 M-1, and KD = 1.43 x 10-8 M. This study thus established the foundation for isolation of carbohydrate-specific scFv genes and eventual production of humanized scFv-Fc type antibodies.

Antibody Specificity↗

Generation of plant protein microarrays and investigation of antigen-antibody interactions.

The application of proteomics methods, such as the protein microarray technology, in plant science has been strongly supported by the completion of genome sequencing projects of Arabidopsis thaliana and rice. In this chapter we describe a method to generate plant protein microarrays and to use them for characterizing monoclonal antibodies or polyclonal sera with regard to their specificity and cross-reactivity. The method starts with characterized E. coli cDNA expression clones encoding His-tagged plant proteins. After expression and purification of these recombinant proteins in high throughput, protein microarrays are generated utilizing a contact printer. For the detection of the recombinant proteins on the microarrays, an anti-RGS-His6 antibody is used. To characterize specific antibodies, the microarrays are incubated with the respective antibody solutions followed by fluorescently labeled secondary antibodies. Signal detection is performed by means of an arrayscanner system. Protein microarrays containing the whole proteome of a plant will represent the ideal format to test antibody specificity and cross-reactivity in the future.

Antibody Specificity↗

Standardization of FSH, LH and hCG--current position and future prospects.

Gonadotropin measurements contribute significantly to patient management in both endocrinology and oncology. Differences in calibration, antibody specificities and assay design mean that gonadotropin results obtained in different methods are still not comparable. Comparing patient results obtained in different methods therefore remains problematic, whether for individual patient care, when assessing the results of multicentre clinical trials, or when formulating national and international guidelines and recommendations. Achieving improved comparability of results for these important analytes will require clear descriptive nomenclature, accurate calibration with highly purified standards, careful characterization of what gonadotropin isoforms methods are measuring, broad recommendations about the most clinically appropriate antibody combinations, and increased awareness of clinically relevant interferences and the action required to minimise their effect. Encouraging manufacturers to standardize and carefully describe the evaluation methods they use, such that data from different manufacturers can readily be compared, is also a pre-requisite for future progress.

Antibody Specificity↗