Search PubMed⌕ Search

PubMed · 9927367

Interstitial lung disease: A quantitative study using the adaptive multiple feature method.

Abstract

We have previously described an adaptive multiple feature method (AMFM) for the objective assessment of global and regional changes in pulmonary parenchyma to detect emphysema. This computerized method uses a combination of statistical and fractal texture features for characterization of lung tissues based upon high resolution computed tomography (HRCT) scans. This present study was a substantial extension of the AMFM to simultaneously discriminate between multiple pulmonary disease processes. Normal subjects and those with emphysema, idiopathic pulmonary fibrosis (IPF), or sarcoidosis were studied. The AMFM was compared with two currently utilized computer-based methods: mean lung density (MLD) and the histogram analysis (HIST). Globally, when comparing two-subject groups the AMFM overall accuracy was 2 to 18% better than the overall accuracy of MLD and as much as 36% better than the accuracy of the HIST methods. In three-subject group discrimination tasks, the AMFM performed 7 to 27% better than the MLD and 4 to 36% better than the HIST methods. Finally, in discriminating all four subject groups at a time, the AMFM overall accuracy was 81%, which was 21% better than the MLD and 25% better than the HIST method. In most three-subject group comparisons and in the four-subject group comparison, the AMFM was significantly (p < 0.01) better than the MLD and HIST methods. Next, the AMFM was applied to local discrimination between normal and each disease group individually. The normal versus emphysema, normal versus IPF, and normal versus sarcoidosis samples were discriminated with an accuracy of 95, 86, and 77%, respectively. The AMFM is an objective quantitative method that can be adapted for successful discrimination of multiple parenchymal lung diseases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Uppaluri, E A Hoffman, M Sonka, G W Hunninghake, G McLennan. 1999. Interstitial lung disease: A quantitative study using the adaptive multiple feature method.. https://doi.org/10.1164/ajrccm.159.2.9707145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Use of a screening device for sleep apnea in clinical practice].

About 2-4% of adults suffer from obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder (SRBD). Repetitive obstructions of the upper airway mean that it is associated with hypertension and an elevated cardio- and cerebrovascular morbidity, which can be lowered by means of effective therapy. These patients cannot be treated correctly unless they are identified early in the course of the condition. Therefore, this study evaluated the use of the microMESAM screening device (known up to December 2005 as the "ApneaLink") in 61 patients in whom SRBD was suspected. The device proved reliable and practical in application.

Diagnosis, Computer-Assisted↗

Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

RATIONALE AND OBJECTIVES: We developed a computerized scheme for detection of lung nodules in the lateral views of chest radiographs, in order to improve the overall performance in combination with the computer-aided diagnostic (CAD) scheme for posterior-anterior (PA) views. MATERIALS AND METHODS: We used 106 pairs of PA and lateral views of chest radiographs (122 lung nodules) for development of the CAD scheme. In the CAD scheme for lateral views, initial candidates of lung nodules were identified by use of a nodule enhancement filter based on the edge gradients. Thirty-four image features extracted from the original and the nodule-enhanced images were used for the rule-based scheme and for artificial neural networks (ANNs) for removal of some false-positive candidates. The computer performance was evaluated with a leave-one-case-out test method for ANNs. For PA views, we used the existing CAD scheme, which was trained with one-half of 924 chest images and then tested with the remaining images. RESULTS: When the CAD scheme was applied only to PA views, the sensitivity in the detection of lung nodules was 70.5%, with 4.9 false positives per image. Although the performance of the computerized scheme for lateral views was relatively low (60.7% sensitivity with 1.7 false positives per image), the overall sensitivity (86.9%) was improved (6.6 false positives per two views), because 20 (16.4%) of the 122 nodules were detected only on lateral views. CONCLUSIONS: The CAD scheme by use of lateral-view images has the potential to improve the overall performance for detection of lung nodules on chest radiographs when combined with a conventional CAD scheme for standard PA views.

Diagnosis, Computer-Assisted↗

Improvement of the detection of myocardial ischemia thanks to information technologies.

BACKGROUND: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. METHODS: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. RESULTS: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. CONCLUSIONS: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia.

Diagnosis, Computer-Assisted↗