Search PubMed⌕ Search

PubMed · 9877288

Computer-generated three-dimensional reconstructions of serially sectioned mouse embryos.

Abstract

We have been involved with a group of computer scientists and anatomists in the development of computer-based methodologies that not only combine the advantages of scanning electron microscopy and conventional histology, but provide the additional dimension of tissue recognition. The latter is achieved by the appropriate labelling of tissues and structures by delineation or 'painting'. Individually segmented anatomically defined tissues can be highlighted in a particular colour and viewed either in isolation or in combination with other appropriately labelled tissues and organs. Tissues can be shown in any orientation either as a transparent overlay on computer-generated histological sections or as 3-D images without the histological background. An additional feature of the system is that computer graphics technology combined with 3-D glasses now also allows the viewer to see the object under analysis in stereo. This facility has been found to be particularly helpful in drawing attention to topological relationships that had not previously been readily noted. As the mouse is now the mammalian model of choice in many areas of developmental research, it is of critical importance that a basic level of skill is available in the research community in the interpretation of serially sectioned material, for example, for the rapidly expanding field in which gene expression studies play a significant role. It is equally important that there is an understanding of the dynamic changes that occur in relation to the differentiation of the various organ systems seen in these early stages of development. What we emphasise here is the additional information that it is possible to gain from the use of this tool which, in our view, could not readily have been gained from the analysis of scanning electron micrographs or by studying conventional serial histological sections of similar stages of mouse embryonic development. The methodology has been developed as part of a large project to prepare a database of mouse developmental anatomy covering all stages from fertilisation to birth in order to allow the accurate spatial mapping of gene expression and cell lineage data onto the digital Atlas of normal mouse development. In this paper we show how this digital anatomical Atlas also represents a valuable teaching aid and research tool in anatomy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Kaufman, R M Brune, D R Davidson, R A Baldock. 1998. Computer-generated three-dimensional reconstructions of serially sectioned mouse embryos.. https://doi.org/10.1046/j.1469-7580.1998.19330323.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-field magnetic resonance imaging of meniscoids in the zygapophyseal joints of the human cervical spine.

STUDY DESIGN: Prospective in vitro study of meniscoids in the cervical zygapophysial joints. OBJECTIVES.: To assess the use of high-field magnetic resonance imaging (MRI) as a potential tool for evaluating meniscoids of the cervical zygapophysial joints. SUMMARY OF BACKGROUND DATA: Pain originating from the cervical spine is a frequent condition. It has been suggested that pathologic conditions of meniscoids within the zygapophysial joints may cause pain. METHODS: Six zygapophysial joints from one embalmed human body were investigated with a 3.0-T MR unit, equipped with a microimaging-set. MRIs were correlated with microanatomical sections. RESULTS: High-quality images of the meniscoids were obtained for all joints examined. There was a good correlation between the anatomic features derived from MRI and the microanatomical sections. CONCLUSIONS: High-field MRI was successfully implemented as a noninvasive method for imaging the meniscoids in cervical zygapophysial joints. The results of this in vitro study indicate that high-field MRI may be feasible in evaluating patients with cervical pain possibly related to meniscoid pathology.

Anatomy, Cross-Sectional↗

Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

We have constructed a three-dimensional (3D) whole body mouse atlas from coregistered x-ray CT and cryosection data of a normal nude male mouse. High quality PET, x-ray CT and cryosection images were acquired post mortem from a single mouse placed in a stereotactic frame with fiducial markers visible in all three modalities. The image data were coregistered to a common coordinate system using the fiducials and resampled to an isotropic 0.1 mm voxel size. Using interactive editing tools we segmented and labelled whole brain, cerebrum, cerebellum, olfactory bulbs, striatum, medulla, masseter muscles, eyes, lachrymal glands, heart, lungs, liver, stomach, spleen, pancreas, adrenal glands, kidneys, testes, bladder, skeleton and skin surface. The final atlas consists of the 3D volume, in which the voxels are labelled to define the anatomical structures listed above, with coregistered PET, x-ray CT and cryosection images. To illustrate use of the atlas we include simulations of 3D bioluminescence and PET image reconstruction. Optical scatter and absorption values are assigned to each organ to simulate realistic photon transport within the animal for bioluminescence imaging. Similarly, 511 keV photon attenuation values are assigned to each structure in the atlas to simulate realistic photon attenuation in PET. The Digimouse atlas and data are available at http://neuroimage.usc.edu/Digimouse.html.

Anatomy, Cross-Sectional↗

Coronary artery stenosis quantification using multislice computed tomography.

RATIONALE AND OBJECTIVES: Reliable noninvasive detection of stenoses with multislice computed tomography (MSCT) is feasible. This study's aim was to analyze the agreement, correlation, and reliability of MSCT with conventional coronary angiography as the reference standard for quantification of coronary artery stenoses. MATERIALS AND METHODS: A total of 118 significant (at least 50%) coronary artery stenoses with a reference vessel diameter of at least 1.5 mm in 62 patients were analyzed by MSCT using 16 detector rows (Aquilion, Toshiba, Otawara, Japan), multisegment reconstruction, and voxel sizes of 0.35x0.35x0.5 mm. The degree of stenosis on MSCT and quantitative coronary angiography (QCA) was measured by correlating the difference between the reference vessel diameter (average of 2 measurements directly proximal and distal to the stenosis) and the stenotic vessel diameter to the reference vessel diameter. RESULTS: Correlation between the percent diameter stenosis determined by MSCT (78.2+/-13.6%) and QCA (76.0+/-14.8%) was significant (P<0.001) but only moderately so (R=0.51). Bland-Altman analysis revealed no systematic under- or overestimation with MSCT but large limits of agreements (+/-27.6%). Also the limits of agreement for interobserver agreement (reliability) of MSCT data were considerably large (+/-24.8%). Among the 27 coronary artery stenoses with a reference diameter of at least 3.5 mm, there was improved correlation (R=0.80) and the limits of agreement between MSCT and QCA were significantly smaller (+/-17.3%, P<0.008). The agreement between MSCT and QCA was not significantly different for stenoses with no calcification or only calcium spots (+/-28.2%) as compared with those with moderate-or-severe calcifications (+/-27.3%; P=0.8). MSCT allowed correct classification of coronary stenoses into low-grade (below 75%) and high-grade stenoses (at least 75%), in 62% (73 of 118). CONCLUSIONS: The accuracy and reliability of coronary artery stenosis quantification with MSCT using isotropic voxel sizes and multisegment reconstruction is still too low to recommend routine clinical application because of rather low agreement, correlation, and reliability. Despite these limitations, the current results demonstrate the potential of MSCT for reliable and accurate quantification of coronary artery stenoses in the near future provided that further improvements in spatial and temporal resolution will be achieved.

Anatomy, Cross-Sectional↗