Search PubMed⌕ Search

PubMed · 9874409

The Vodder School: the Vodder method.

Abstract

BACKGROUND: The history and development of manual lymphatic drainage (MLD) from Winiwarter to Vodder and the Vodder School of today are discussed. METHODS: The Vodder technique differs in the use of adapted pressure and its application. The constant change in pressure optimizes results, moving fluid in the skin, increasing lymphomotoricity, and softening fibrosis, with the positive side effects of reducing pain and relaxing tense muscles. Another difference from other methods is the technique of stretching skin, not sliding it. Because of the fluid content in lymphedema, which is different from all other edemas, the combination of MLD with compression treatment is the only solution for this pathology. Depending of it severity, each case requires individualized treatment. Phase 1 (intensive treatment) consists of daily treatment with up to two sessions per day for up to 2 hours. This phase is combined with special, individual skin care and remedial exercise. In phase 2, the goal of treatment is to maintain the results achieved in phase 1. The frequency of treatment is changed, but there is still the need for permanent, continued therapy. RESULTS: In phase 1, an average reduction of more than 40% of edema volume is achieved. In phase 2, the results are maintained and, with repetitions of phase 1, further improvement is possible. Thus, long term results with permanent improvement are possible. CONCLUSIONS: Because of the complexity of the technique, no one can learn MLD in 1 week. Students require a great deal of correction, and the technique must be checked constantly. To become a certified Vodder therapy, a 4-week education program must be completed, and reviews must be attended every 2 years to maintain certification. The best education produces the best results for patients as long as patients are compliant. Therefore, the Vodder School also includes a patient education program as part of its curriculum.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R G Kasseroller. 1998-12-15. The Vodder School: the Vodder method.. https://doi.org/10.1002/(sici)1097-0142(19981215)83%3A12b%2B%3C2840%3A%3Aaid-cncr37%3E3.0.co%3B2-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Cochlear implantation--the Viennese surgical technique].

The aim of the study was to report the current surgical procedure that has been established on the basis of about 200 implantations with the Combi 40/40+ implant system. The outstanding features of this procedure are the skin incision and the fact that the electrode can be inserted up to a depth of 34 mm into the cochlea. In order to provide better magnetic positioning of the external parts, a flap-reducing technique may be required. For insertion we used a soft surgery method to preserve structures within the cochlea. In some cases we were able to inspect the cochlea with microendoscopes, which helped to prevent electrode kinking, since fibrous obliterations were found before the insertion. For electrode fixation in the mastoid cavity we used bone paté.

Austria↗

[Postoperative imaging and evaluation of the electrode position and depth of insertion of multichannel cochlear implants by means of high-resolution computed tomography and conventional X-rays].

Following cochlear implantation, postoperative imaging of the electrode is very important in order to measure the depth of insertion and the position of the electrode, so that kinking and incorrect electrode placement can be clearly identified. The aim of this study was to outline the diagnostic value of CT and conventional X-ray for these parameters. For this purpose we obtained radiographs of patients who had received a cochlear implant. Computed tomography was performed by obtaining axial sections. For conventional X-ray we used digital imaging, utilising a modified Chausse III projection. The images were then rated according to electrode position, insertion depth and possible complications. We also measured the radiation dose using a dummy and evaluated the cost of each examination. Both examinations permit excellent identification of electrode position and insertion depth. However, the depth of insertion can be measured much more accurately by means of digital X-ray. The radiation dose of CT was 230 times higher than that of conventional X-ray and the cost of CT 5 times that of digital X-ray.

Austria↗