Search PubMed⌕ Search

PubMed · 9764214

Lead in wine.

Abstract

Elevated levels of lead in wine have been explained by several possible contamination sources: leaded gasoline, tin-lead capsules (used to cover the bottle neck), and brass alloys. Lead measurements from 7000 wines were used to identify possible sources and these showed that atmospheric pollution-related contamination (leaded gasoline) was not responsible for elevated lead concentrations in wine. It also was shown that the presence or absence of tin-lead capsules as well as the state of tin-lead capsule corrosion had only a very minor influence on the lead concentration in wine. The reported positive correlation between wine age and lead concentration was confirmed by our data. However, further statistical analysis revealed that not the age of wine but the vintage and the wine colour were the most significant contributing factors. The wine age itself was no longer correlated with the lead concentration after controlling for the significant variables mentioned. The conclusions drawn agree well with the explanation that brass is the main contamination source. Inspections of wineries known for elevated lead levels always revealed the presence of brass tubes and faucets. There has been a continuing and significant reduction of lead levels in wine during the recent 7 years where measurements were made.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Kaufmann. Lead in wine.. https://doi.org/10.1080/02652039809374664

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of solution pH and electrical parameters on hydroxyapatite coatings deposited by a plasma-assisted electrophoresis technique.

Hydroxyapatite (HA) coatings can be deposited using a hybrid process of plasma electrolysis and electrophoresis, called plasma-assisted electrophoretic deposition (PEPD). HA aqueous suspensions with various pH values were prepared using a modified ultrasonic cleaning bath as an agitator/stirrer. Both DC and unbalanced AC power supplies were used to bias the titanium alloy substrate materials employed in this work. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffractometry (XRD), and Fourier transform infrared spectroscopy (FTIR) were used to observe and analyze coating morphology and microstructure. It was shown that the morphology and composition of the calcium phosphate coatings were significantly influenced by solution pH values; the level of "pure" HA in the coatings' composition corresponded to both solution pH and the type of power supply employed. Loss of hydroxyl radials (i.e., dehydroxylation), which degrades the performance of the hydroxyapatite coating in terms of long-term chemical and mechanical stability, can be virtually eliminated by a combination of high pH and unbalanced AC plasma power. In addition, the underlying TiO2 coatings used to support the HA layer (preproduced by plasma electrolysis process) have a nanoscaled (10-20 nm) polycrystalline structure. TEM studies also revealed a dense, continuous amorphous titania layer (10 nm in thickness) at the interface between the Ti alloy substrate and the TiO2 layer, which may play a role in improving the corrosion resistance of the substrate. Such a nanophase TiO2 layer (if used as a coating alone) may also provide a further improvement in osteoinductive properties, compared to a conventional TiO2 coating on the Ti alloy substrate.

Alloys↗

Biomimetic coprecipitation of calcium phosphate and bovine serum albumin on titanium alloy.

Titanium alloy implants were precoated biomimetically with a thin and dense layer of calcium phosphate and then incubated either in a supersaturated solution of calcium phosphate or in phosphate-buffered saline, each containing bovine serum albumin (BSA) at various concentrations, under physiological conditions for 48 h. Coated implants then underwent scanning electron microscopy, immunohistochemical evaluation, Fourier transform infrared spectroscopy, and X-ray diffraction. The quantity of BSA taken up by coatings and the kinetics of protein release were monitored colorimetrically. In coatings prepared by the coprecipitation of calcium phosphate and BSA, protein had become incorporated into the mineral crystal latticework. With increasing BSA concentration, matrices decreased in thickness, became more dense, showed lower crystallinity, and underwent a change in crystal geometry. The octacalcium phosphate structure manifested in the absence of protein was gradually transformed into a carbonated apatite form. Preformed mineral coatings became only superficially mantled with a layer of BSA, and the morphology of the mineral matrices themselves remained unchanged. At equivalent protein concentrations, coatings prepared by the coprecipitation of calcium phosphate released only a minute fraction of its protein component under physiological conditions, whereas preformed mineral matrices showed a "burst" release of their associated protein within a single 2-h period. The biomimetic coating can be a carrier for osteoinductive agents.

Alloys↗

In vitro mechanical integrity of hydroxyapatite coatings on Ti-6Al-4V implants under shear loading.

A new test method for the mechanical behavior of coatings on metal substrates under shear loading has been developed. Finite element simulations show that this new test method provides an almost identical shear load on the coatings to that of the conventional test. Using the new method, the static and fatigue behavior of plasma-sprayed hydroxyapatite (HA) coatings on Ti-6Al-4V substrates were studied at room temperature as a function of processing conditions. The results of the static tests show that the nominal interface shear strength is in the range of 25 approximately 40 MPa. The fatigue resistance to cyclic shear loading was characterized by shear stress amplitude versus cycle-to-failure for the samples that failed within 1010(7)cycles, and by residual nominal interfacial shear strength for the samples that survived 1010(7)cycles. The experimental results indicate that a threshold level of shear stress amplitude exists for introducing fatigue damage to HA coatings. AES and XPS studies indicated that bonding between the coating and substrate does not occur over about 12 percent of the area of the interface while bonding in the contact area of the interface is mainly mechanical interlocking. A failure mechanism of interfacial microflaw coalescence is suggested.

Alloys↗