Search PubMed⌕ Search

PubMed · 9697059

Red cell membrane damage.

Abstract

Turbulent shear stresses created by the fluid dynamic characteristics of prosthetic valves cause damage to blood cells. Platelet activation and damage is extensively described and red blood cell hemolysis is reported in a significant number of valve replacements. Most of these studies have evaluated hemolysis in normal red cells and relate to different valves or replacement procedures rather than the red cell. Prehemolytic red cell damage is rarely considered and only few studies describe the effect of valve replacement on patients with red cell disorders. While hemolytic anemia is the ultimate end-point of valve-induced red cell damage, loss of red cells goes hand in hand with the formation of red cell-derived damaged membranes. It can be hypothesized that alterations (in subpopulations) of red cells and generation of red cell remnants due to the increased shear stress could have a profound physiologic effect before hemolytic anemia is apparent. In patients with red cell disorders, alterations in the red cell membrane suggest that red cell damage will be more pronounced after valve replacement. In this review, determinants of normal and abnormal red cell behavior under shear are discussed as well as some of the possible physiologic consequences of the formation of damaged red cell membranes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F A Kuypers. 1998. Red cell membrane damage.. https://pubmed.ncbi.nlm.nih.gov/9697059/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Theoretical model and experimental study of red blood cell (RBC) deformation in microchannels.

The motion and deformation of red blood cells (RBCs) flowing in a microchannel were studied using a theoretical model and a novel automated rheoscope. The theoretical model was developed to predict the cells deformation under shear as a function of the cells geometry and mechanical properties. Fluid dynamics and membrane mechanics are incorporated, calculating the traction and deformation in an iterative manner. The model was utilized to evaluate the effect of different biophysical parameters, such as: inner cell viscosity, membrane shear modulus and surface to volume ratio on deformation measurements. The experimental system enables the measurement of individual RBCs velocity and their deformation at defined planes within the microchannel. Good agreement was observed between the simulation results, the rheoscope measurements and published ektacytometry results. The theoretical model results imply that such deformability measuring techniques are weakly influenced by changes in the inner viscosity of the cell or the ambient fluid viscosity. However, these measurements are highly sensitive to RBC shear modulus. The shear modulus, estimated by the model and the rheoscope measurements, falls between the values obtained by micropipette aspiration and laser trapping. The study demonstrates the integration of a theoretical model with a microfabricated device in order to achieve a better understanding of RBC mechanics and their measurement using microfluidic shear assays. The system and the model have the potential of serving as quantitative clinical tools for diagnosing deformability disorders in RBCs.

Erythrocyte Deformability↗

Direct measurement of the impact of impaired erythrocyte deformability on microvascular network perfusion in a microfluidic device.

The ability of red blood cells (RBCs, erythrocytes) to deform and pass through capillaries is essential for continual flow of blood in the microvasculature, which ensures an adequate supply of oxygen and nutrients, prompt removal of metabolic waste products, transport of drugs and hormones, and traffic of circulating cells to and from all living tissues. This paper presents a novel tool for evaluating the impact of impaired deformability of RBCs on the flow of blood in the microvasculature by directly measuring perfusion of a test microchannel network with dimensions and topology similar to the real microcirculation. The measurement of microchannel network perfusion is compared with RBC filtration -- a conventional assay of RBC deformability. In contrast to RBC filterability, network perfusion depends linearly on RBC deformability modulated by graded exposure to glutaraldehyde, showing a higher sensitivity to small changes of deformability. The direct measurement of microchannel network perfusion represents a new concept for the field of blood rheology and should prove beneficial for basic science and clinical applications.

Erythrocyte Deformability↗