Search PubMed⌕ Search

PubMed · 9670523

An active noise control algorithm for controlling multiple sinusoids.

Abstract

The filtered-x LMS algorithm and its modified versions have been successfully applied in suppressing acoustic noise such as single and multiple tones and broadband random noise. This paper presents an adaptive algorithm based on the filtered-x LMS algorithm which may be applied in attenuating tonal acoustic noise. In the proposed method, the weights of the adaptive filter and estimation of the phase shift due to the acoustic path from a loudspeaker to a microphone are computed simultaneously for optimal control. The algorithm possesses advantages over other filtered-x LMS approaches in three aspects: (1) each frequency component is processed separately using an adaptive filter with two coefficients, (2) the convergence parameter for each sinusoid can be selected independently, and (3) the computational load can be reduced by eliminating the convolution process required to obtain the filtered reference signal. Simulation results for a single-input/single-output (SISO) environment demonstrate that the proposed method is robust to the changes of the acoustic path between the actuator and the microphone and outperforms the filtered-x LMS algorithm in simplicity and convergence speed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S M Lee, H J Lee, C H Yoo, D H Youn, I W Cha. 1998. An active noise control algorithm for controlling multiple sinusoids.. https://doi.org/10.1121/1.423276

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance of small-scale CHO perfusion cultures using an acoustic cell filtration device for cell retention: characterization of separation efficiency and impact of perfusion on product quality.

Several small-scale Chinese hamster ovary (CHO) suspension cultures were grown in perfusion mode using a new acoustic filtration system. The separation performance was evaluated at different cell concentrations and perfusion rates for two different CHO cell lines. It was found that the separation performance depends inversely on the cell concentration and perfusion rate. High media flow rates as well as high cell concentrations resulted in a significant drop in the separation performance, which limited the maximal cell concentration achievable. However, packed cell volumes of 10% to 16% (corresponding to 3 to 6. 10(7) cells/mL) could be reached and were maintained without additional bleeding after shifting the temperature to 33 degrees C. Perfusion, up to 50 days, did not harm the cells and did not result in a loss of performance of the acoustic filter as often seen with other perfusion systems. Volumetric productivities in perfusion mode were 2- to 12-fold higher for two cell lines producing two different glycoproteins when compared to fed-batch or batch processes using the same cell lines. Product concentrations were in the range of 20% to 80% of batch or fed-batch culture, respectively. In addition, using the protease-sensitive product rhesus thrombopoietin, we could show that cultivation in perfusion mode drastically reduced proteolysis when compared to a batch culture without addition of protease inhibitors such as leupeptin.

Acoustics↗

[Rehabilitation of hearing-impaired patients with cochlear implants: a review].

The aim of this paper is to provide an overview of the cochlear implant. The history of this entity is traced from the early development of implants, involving the stimulation of the hearing nerve, up to the currently available standard multichannel implants. The physiological background is also elucidated. A cochlear implant consists of an implantable portion which lies within the ear, and of parts that are worn externally on the body. Differences between the first implants and those now in use are as follows: transcutaneous information and energy transmission, the position of the electrode in the ear, and the configuration of the electrode. Differences between the currently available implants mainly concern the number of electrodes, speech coding strategies and the mode of electrode stimulation. Almost all of the most recent implants are equipped with electrodes that are implanted in the tympanic scale of the cochlea.

Acoustics↗

Adsorptions of plasma proteins and their elutabilities from a polysiloxane surface studied by an on-line acoustic wave sensor.

Gold electrodes of thickness-shear mode acoustic wave sensors were modified with poly[(mercaptopropyl)methylsiloxane]. The flow-through adsorption of three major plasma proteins (human serum albumin, fibrinogen, and immunoglobulin G) was detected by acoustic network analysis. The elution of fibrinogen and albumin from coated and unmodified gold surfaces by sodium dodecyl sulfate was studied with respect to different adsorption times and protein concentrations. Both sequential and competitive adsorptions of the three proteins on polymer-modified surfaces of sensors were examined as were simultaneous adsorptions from binary and ternary mixtures. The experimental results confirm that the competitive behaviors of proteins in terms of adsorptive processes are explained by factors other than displacement phenomena.

Acoustics↗